Basic Compressor Design Calculations
Basic Compressor Design Calculations
(1.3−1)
𝑇𝑑 (𝐾) = 296(8.5) 1.3 = 485 𝐾
Way too high discharge temperature, consider water-cooled compressor.
Next, to determine volumetric efficiency (VE), which is the ratio of the amount of gas
compressed versus the physical size of the compressor's cylinder volume:
For 2 stage compressors:
1
𝑉𝐸(%) = 89 − 𝑅 − 7.8(𝑅 2𝑛 − 1)
1
𝑉𝐸(%) = 89 − 8.5 − 7.8 (8.52(1.30) − 1) = 70.54%
References:
1. Blackmer (1999). ‘Steps to Compressor Selection & Sizing’ [online] Available at:
https://www.gasequipment.com/catalogs/cryogenic/pdf/Blackmer/Compressors/Comp
%20Selection%20and%20Sizing.pdf [Accessed 22nd March 2020]
2. Engineering ToolBox, (2005). Critical Points of some Substances. [online] Available
at: https://www.engineeringtoolbox.com/critical-point-d_997.html [Accessed 22nd
March 2020]
3. Engineering ToolBox, (2005). Critical Points of some Substances. [online] Available
at: https://www.engineeringtoolbox.com/critical-point-d_997.html [Accessed 22nd
March 2020]