Bukaan Valve Waktu (S) Debit (m3/s) Q Rata-Rata (m3/s) Volume Q (Liter)

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 22

Volume Q

Bukaan Valve Waktu (s) Debit (m3/s) Q rata-rata (m3/s)


(liter)
0.01 50.4 0.000198412698413
25% 0.015 75 0.0002 0.000192541389316
0.02 111.6 0.000179211469534
0.01 49.6 0.000201612903226
50% 0.015 74.3 0.000201884253028 0.00019588640629
0.02 108.6 0.000184162062615
0.01 48.7 0.000205338809035
75% 0.015 72.1 0.000208044382802 0.000201651357688
0.02 104.4 0.000191570881226
0.01 47.9 0.000208768267223
100% 0.015 71.3 0.000210378681627 0.000205918893576
0.02 100.7 0.000198609731877

cm ft 0.00656167979
Panjang pipa 165 5.4133695 0.007655293088333

ID pipa 6.25 0.020505188 0.008748906386667

Luas
0.000660126 0.009842519685
Penampang

11.20

11.00

10.80

10.60
V (Ft/S)

LOG V

10.40

10.20

10.00

9.80
0.006 0.0065 0.007 0.0075 0.008 0.0085 0.009 0.0095 0.01 0.0105
-2.2 -2.15
Head Loss (FtHg)
m->ft

Head Loss (ha-


ha (mmHg) hb (mmHg) Bukaan valve
hb)
450 448 2
452 451 1 25%
451 450 1
453 451 2
451 448 3 50%
451 449 2
450 446 4
450 448 2 75%
451 449 2
451 448 3
452 448 4 100%
452 450 2

10.30 -2.1829849670053 1.012851716


10.48 -2.1160381773747 1.020331913 Panjang pipa
-2.058046230397 1.032928765 ID pipa
10.79

11.02 -2.0068937079496 1.042023811 Luas


Penampang

1.045 0.00652
1.04 0.0065
1.035 0.00648
1.03 0.00646
0.00644
Friction Loss

1.025
1.02 0.00642
1.015 0.0064
1.01 0.00638
1.005 0.00636
1 0.00634
0.995 0.00632
-2.15 -2.1 -2.05 -2 -1.95 0 0 0 0 0 0 0
1 60 180 200 220 240 260 280 300
LOG H 2 2 2 2 2 2
RNe 2 2
3.280839895

Q rata-rata (ft3/det) V (ft/det) H (ft Hg) log V log H Nre

6.80E-03 10.30 0.0065616798 1.0128517157 -2.182984967 21,823.14

6.92E-03 10.48 0.0076552931 1.0203319133 -2.116038177 22202.269746

7.12E-03 10.79 0.0087489064 1.0329287649 -2.05804623 22855.684184

7.27E-03 11.02 0.0098425197 1.0420238105 -2.006893708 23339.377691

cm ft
165 5.4133695 densitas fluida 1.001
viskositas
6.25 0.0205051875 0.009
fluida

0.0006601265 densitas raksa 13.6

0 0 0 0 0 0 0 0
220 240 260 280 300 320 340 360
2 2 2
RNe 2 2 2 2 2
21823 0.00649976713
22202 0.00647183964
22855 0.00642507993
23339 0.00639152914
f F Pressure Drop

0.0064997671 2.8270 5.57100262464963

0.0064718396 2.9135 6.49950306209124

0.0064250799 3.0652 7.42800349953284

0.0063915291 3.1796 8.35650393697445

62.490428
0.0006048

849.0208
Volume Q Q rata-rata
Bukaan Valve Waktu (s) Debit (m3/s) ha (mmHg)
(liter) (m3/s)
0.01 50.3 0.000198807 462
25% 0.015 72.1 0.000208044 0.000205498382 462
0.02 95.4 0.000209644 460
0.01 50.1 0.000199601 463
50% 0.015 70.1 0.00021398 0.000208556635 463
0.02 94.3 0.000212089 469
0.01 49.4 0.000202429 460
75% 0.015 69.2 0.000216763 0.000211338309 469
0.02 93.1 0.000214823 462
0.01 49.2 0.000203252 463
100% 0.015 69.1 0.000217077 0.00021225965 462
0.02 92.4 0.00021645 461

cm ft 0.005468066492 10.99
Panjang pipa 165 5.4133695 0.00656167979 11.16

ID pipa 6.25 0.020505188 0.007655293088


11.31
Luas
0.000660126 0.008748906387
Penampang 11.36

11.40

11.30

11.20
V (Ft/S)

11.10

11.00

10.90

10.80
0.005 0.0055 0.006 0.0065 0.007 0.0075 0.008 0.0085 0.009
Head Loss (FtHg)
m->ft

hb (mmHg) Head Loss (ha-hb) Bukaan valve

460 2
460 2 25%
459 1
461 2
461 2 50%
467 2
458 2
466 3 75%
460 2
461 2
459 3 100%
458 3

-2.26216621305294 1.041136
-2.18298496700532 1.047552 Panjang pipa
-2.11603817737471 1.053306 ID pipa

Luas
-2.05804623039702 1.055195
Penampang

1.06

1.055

1.05
LOG V

1.045

1.04

1.035

1.03
0.0075 0.008 0.0085 0.009 -2.3 -2.25 -2.2 -2.15 -2.1 -2.05 -2

Hg) LOG H
3.280839895

Q rata-rata (ft3/det) V (ft/det) H (ft Hg) log V log H

7.26E-03 10.99 0.0054680665 1.0411360211 -2.2621662131

7.37E-03 11.16 0.0065616798 1.047551625 -2.182984967

7.46E-03 11.31 0.0076552931 1.0533058425 -2.1160381774

7.50E-03 11.36 0.0087489064 1.0551950578 -2.0580462304

cm ft
165 5.4133695 densitas fluida
viskositas
6.25 0.0205051875
fluida

0.000660126461624 densitas raksa

1.06
0.0064
1.055 0.00639
0.00638
1.05
0.00637
Friction Loss

1.045 0.00636
0.00635
1.04 0.00634
0.00633
1.035
0.00632
1.03 0.00631
2.1 -2.05 -2 23200 23300 23400 23500 23600 23700 23800 23900 24000 24100 24200
RNe

23291 0.0063947964
23638 0.0063712232
23953 0.0063501541
24058 0.0063432519
Nre f F Pressure Drop

23,291.72 0.0063947964 3.1682 4.64250218720803

23638.34607226 0.0063712232 3.2512 5.57100262464963

23953.62818376 0.0063501541 3.3275 6.49950306209124

24058.05533076 0.0063432519 3.3529 7.42800349953284

1.001 62.490428
0.009 0.0006048

13.6 849.0208

000 24100 24200


Volume Q
Bukaan Valve Waktu (s) Debit (m3/s) Q rata-rata (m3/s) ha (mmHg)
(liter)
0.01 16.4 0.000609756 470
25% 0.015 29 0.000517241 0.000587306037264 468
0.02 31.5 0.000634921 470
0.01 14.7 0.000680272 468
50% 0.015 28.3 0.000530035 0.000633320872315 468
0.02 29 0.000689655 464
0.01 14 0.000714286 468
75% 0.015 27.9 0.000537634 0.000657114861107 464
0.02 27.8 0.000719424 469
0.01 13.2 0.000757576 465
100% 0.015 27.1 0.000553506 0.000682125136759 463
0.02 27.2 0.000735294 467

cm ft 0.012029746281667 31.42

Panjang pipa 165 5.4133695 0.01312335958


33.88

ID pipa 6.25 0.020505188 0.014216972878333


35.15
Luas
0.000660126 0.015310586176667 36.49
Penampang

37.00
36.00
35.00
34.00
33.00
V (Ft/S)

32.00
31.00
30.00
29.00
28.00
0.0115 0.012 0.0125 0.013 0.0135 0.014 0.0145 0.015 0.0155 0.016
Head Loss (FtHg)
m->ft

hb (mmHg) Head Loss (ha-hb) Bukaan valve

466 4
465 3 25%
466 4
465 3
463 5 50%
460 4
463 5
460 4 75%
465 4
460 5
458 5 100%
463 4

-1.91974353223074 1.49719208

-1.88195497134134 1.52995142 Panjang pipa

-1.84719286508213 1.5459689 ID pipa

-1.81500818171072 1.56219167 Luas


Penampang
1.58

1.56

1.54
LOG V

1.52

1.5

1.48

1.46
-1.94 -1.92 -1.9 -1.88 -1.86 -1.84 -1.82 -1.8
LOG H
3.280839895

Q rata-rata (ft3/det) V (ft/det) H (ft Hg) log V log H Nre

2.07E-02 31.42 0.0120297463 1.4971920797 -1.919743532 66,566.78

2.24E-02 33.88 0.0131233596 1.5299514158 -1.881954971 71782.2186295691

2.32E-02 35.15 0.0142169729 1.5459689036 -1.847192865 74479.0905946822

2.41E-02 36.49 0.0153105862 1.5621916683 -1.815008182 77313.8196449617

cm ft

165 5.4133695 densitas fluida 1.001

viskositas
6.25 0.0205051875 0.009
fluida

0.0006601265 densitas raksa 13.6

1.58
0.00495
1.56 0.0049

1.54 0.00485
Friction Loss

1.52 0.0048

0.00475
1.5
0.0047
1.48
0.00465
1.46
-1.82 -1.8 0.0046
66000 68000 70000 72000 74000 76000 78000
RNe

24380 3.4321
23995 3.3376
21894 2.8431
21440 2.7409
f F Pressure Drop

0.0049182738 19.9028 10.2135048118577

0.0048263951 22.7114 11.1420052492993

0.0047820983 24.2256 12.0705056867409

0.0047376482 25.8621 12.9990061241825

62.490428

0.0006048

849.0208

66566.78 0.00491827384
71782.21863 0.00482639511
74479.09059 0.00478209831
77313.81964 0.0047376482
Volume Q Q rata-rata ha hb
Bukaan Valve Waktu (s) Debit (m3/s)
(liter) (m3/s) (mmHg) (mmHg)

0.01 15.1 0.000662252 468 465


25% 0.015 23.6 0.000635593 0.000633418 469 465
0.02 33.2 0.00060241 467 464
0.01 14.9 0.000671141 468 464
50% 0.015 22.8 0.000657895 0.000654652 468 464
0.02 31.5 0.000634921 467 464
0.01 14.5 0.000689655 466 461
75% 0.015 21.4 0.000700935 0.000677892 466 462
0.02 31.1 0.000643087 469 466
0.01 14.2 0.000704225 468 464
100% 0.015 20.5 0.000731707 0.000700128 468 462
0.02 30.1 0.000664452 467 463

cm ft 0.010936133 33.89
Panjang pipa 165 5.4133695 0.0120297463 35.02

ID pipa 6.25 0.020505188 0.0131233596


36.27
Luas
0.000660126 0.0153105862
Penampang 37.45

38.00

37.00

36.00
V (Ft/S)

35.00

34.00

33.00

32.00
0.01 0.011 0.012 0.013 0.014 0.015 0.016
Head Loss (FtHg)
m->ft 3.280839895

Head Loss
Bukaan valve Q rata-rata (ft3/det) V (ft/det)
(ha-hb)

3
4 25% 2.24E-02 33.89
3
4
4 50% 2.31E-02 35.02
3
5
4 75% 2.39E-02 36.27
3
4
6 100% 2.47E-02 37.45
4

-1.9611362174 1.53001813 cm ft
-1.9197435322 1.54433818 Panjang pipa 165 5.4133695
-1.8819549713 1.55948824 ID pipa 6.25 0.0205051875

Luas
-1.8150081817 1.57350516 0.0006601265
Penampang
1.58 0.00484
1.57 0.00482
0.0048
1.56
0.00478
1.55
Friction Loss

0.00476
LOG V

1.54 0.00474
1.53 0.00472
0.0047
1.52
0.00468
1.51 0.00466
1.5 0.00464
15 0.016 -1.98 -1.96 -1.94 -1.92 -1.9 -1.88 -1.86 -1.84 -1.82 -1.8 71000 72000
LOG H
H (ft Hg) log V log H Nre f F

0.010936132983 1.530018132736 -1.961136217389 71,793.25 0.00482620975 22.7175

0.012029746282 1.544338182339 -1.919743532231 74199.95533783 0.004786589462 24.0669

0.01312335958 1.559488244601 -1.881954971341 76834.04650444 0.004745026746 25.5819

0.015310586177 1.573505163725 -1.815008181711 79354.32928207 0.004706894184 27.0684

densitas fluida 1.001 62.490428


viskositas
0.009 0.0006048
fluida

densitas raksa 13.6 849.0208

0.00484
0.00482
71793.25
74199
0.0048
76834.0465
0.00478
79354.32928
Friction Loss

0.00476
0.00474
0.00472
0.0047
0.00468
0.00466
0.00464
71000 72000 73000 74000 75000 76000 77000 78000 79000 80000
RNe
Pressure Drop

9.28500437441605

10.2135048118577

11.1420052492993

12.9990061241825

0.004826209750438
0.004786589461732
0.004745026746287
0.0047068941836
Volume Q Q rata-rata ha hb
Bukaan Valve Waktu (s) Debit (m3/s)
(liter) (m3/s) (mmHg) (mmHg)

0.01 15.5 0.000645161 473 459


25% 0.015 23.9 0.000627615 0.000638621 472 458
0.02 31.1 0.000643087 472 458
0.01 15.8 0.000632911 476 457
50% 0.015 22.1 0.000678733 0.000672786 475 454
0.02 28.3 0.000706714 476 464
0.01 13.9 0.000719424 475 456
75% 0.015 21.8 0.000688073 0.000695155 475 455
0.02 29.5 0.000677966 476 456
0.01 13.5 0.000740741 475 454
100% 0.015 21.3 0.000704225 0.000712336 476 456
0.02 28.9 0.000692042 467 455

cm ft 0.0459317585 34.16
Panjang pipa 165 5.4133695 0.0568678915 35.99

ID pipa 6.25 0.020505188 0.0645231846


37.19
Luas
0.000660126 0.0678040245 38.11
Penampang

39.00

38.00

37.00

36.00
LOG V
V (Ft/S)

35.00

34.00

33.00

32.00 -1.36 -1.34 -1


0.04 0.045 0.05 0.055 0.06 0.065 0.07
Head Loss (FtHg)
m->ft 3.280839895

Head Loss Q rata-rata


Bukaan valve V (ft/det)
(ha-hb) (ft3/det)

14
14 25% 2.26E-02 34.16
14
19
21 50% 2.38E-02 35.99
12
19
20 75% 2.45E-02 37.19
20
21
20 100% 2.52E-02 38.11
21

-1.337886927 1.53357085 cm ft
-1.2451328738 1.5562046 Panjang pipa 165 5.4133695
-1.1902842057 1.57040905 ID pipa 6.25 0.0205051875

Luas
-1.1687445279 1.58101243 0.0006601265
Penampang
1.59 0.00485
1.58
0.0048
1.57
1.56
Friction Loss

0.00475
1.55
LOG V

1.54 0.0047
1.53
1.52 0.00465
1.51
1.5 0.0046
-1.36 -1.34 -1.32 -1.3 -1.28 -1.26 -1.24 -1.22 -1.2 -1.18 -1.16 70000 72000
LOG H
H (ft Hg) log V log H Nre f F

0.0459317585 1.5335708485 -1.337886927 72,382.96 0.0048163497 23.0451

0.0568678915 1.5562046042 -1.245132874 76255.3055790151 0.0047540044 25.2457

0.0645231846 1.570409048 -1.190284206 78790.6184801269 0.0047152906 26.7328

0.0678040245 1.5810124296 -1.168744528 80737.9821526571 0.0046865971 27.8998

densitas fluida 1.001 62.490428


viskositas
0.009 0.0006048
fluida

densitas raksa 13.6 849.0208

0.00485

72382 0.00481634972
0.0048
76255 0.00475400435
78790 0.00471529061
Friction Loss

0.00475
80737 0.00468659709

0.0047

0.00465

0.0046
70000 72000 74000 76000 78000 80000 82000
RNe
Pressure Drop

38.9970183725474

48.2820227469635

54.7815258090547

57.5670271213795