Analysis & Design By: Er. Bishnu Pandey Civil Engineer NEC Regd. No. 8547 "A"
Analysis & Design By: Er. Bishnu Pandey Civil Engineer NEC Regd. No. 8547 "A"
I consultant (M/s. Pandey Engineering Consultancy) going to issue this disclaimer letter on behalf of final
structural analysis and design report for Mrs. Sumitra Thapa during and after construction of proposed
super structure.
The site supervisions and quality test of the different constructions materials of the proposed building do
not undertaken by the consultant. Hence any failure or error occurred with the building due to non-
implementation of the recommendations made in this report and structural drawing or due to improper
construction will not be the responsibility of the consultant/designer.
The structural analysis has been completed on the assumptions that the proposed building shall be
constructed under the proper supervisions of skilled technical manpower.
Er . Bishnu Pandey
Civil Engineer
NEC Reg. No. 8547 “A”
ETABS 2017 Concrete Frame Design
IS 456:2000 Column Section Design
Column Element Details Type: Ductile Frame (Summary)
Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
Story1 C11 95 Column DCon12 0 3200 0.72
Section Properties
b (mm) h (mm) dc (mm) Cover (Torsion) (mm)
305 305 60 30
Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
22360.68 20 1 500 500
Section Properties
b (mm) h (mm) bf (mm) ds (mm) dct (mm) dcb (mm)
228.6 355.6 228.6 0 25 25
Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
22360.68 20 1 500 500