DUREBILD HSE
High Build Two Pack Epoxy Coating PC 230

FEATURES • HIGHLY RESISTANT TO CHEMICAL, SOLVENTS AND AGGRESSIVE EXPOSURE


• SUITABLE FOR APPLICATION TO PREPARED CONCRETE
• EXTREMELY TOUGH ABRASION RESISTANT FILM
• HIGH BUILD ONE COAT PROTECTION

USES DUREBILD HSE is a high solids, two component epoxy with high build characteristics allowing single coat
application up to 500 microns dry film thickness direct to suitably prepared mild steel and over inorganic zinc rich or
epoxy anti-corrosive primers.

DUREBILD HSE is especially designed for the protection of marine structures and chemical plants where maximum
resistance to chemicals, abrasion or solvents is required. An abrasion resistant coating for concrete floors.
SPECIFICATIONS AS/NZS 3750.14

RESISTANCE GUIDE
HEAT RESISTANCE Up to 120°C dry heat. ALKALIS Excellent resistance to splash and spillage
of most alkalis.
WEATHERABILITY Epoxy coatings may yellow with time.
On exterior exposure some chalking SALTS Unaffected by splash and spillage of
may also occur. This will not detract neutral and alkaline salt solutions.
from the protective properties of the
coating. Use a weatherable topcoat if WATER Excellent resistance to fresh and salt
required for appearance. water.

SOLVENTS Resists splash and spillage of ABRASION Excellent when fully cured.
aromatic and aliphatic hydrocarbon 205 mg per 1000 cycles
solvents and alcohols. (CS-17, 1000 gm load/wheel)

ACIDS Suitable for splash and spillage ADHESION 8.6 MPa (1258 p.s.i)
exposure to dilute acids. (Adhesion Pull-Off Test, AS1580.408.5)

TYPICAL PROPERTIES AND APPLICATION DATA


APPLICATION CONDITIONS
CLASSIFICATION High build two pack epoxy finish
FINISH Gloss
COLOUR White, N35 Light Grey, limited range of
tinted colours and MTO factory made Refer to Page 2
colours.
COMPONENTS Two
SOLIDS BY VOLUME Refer to Page 2
VOC LEVEL Refer to Page 2 Min Max Recom.
FLASH POINT 16°C Wet film per coat (microns)
Refer to Page 2
POT LIFE Refer to Page 2 Dry film per coat (microns)
MIXING RATIO (V/V) Part A : 4 Part B : 1
SUITABLE SUBSTRATES Blast cleaned steel.
THINNER 920-08925 Dulux Epoxy Thinner Suitably primed steel and
prepared concrete.
PRODUCT CODE 744-63001 White/Light Base
744-63002 Deep Base PRIMERS Inorganic zinc or two-pack epoxy.
744-38678 N35 Light Grey
980-50251 Standard Hardener APPLICATION METHODS Conventional, airless spray or
980-50269 Fast Hardener roller.

June 2010 Page 1 of 3 PC 230


DUREBILD® HSE

Standard Hardener
COATING THICKNESS APPLICATION CONDITIONS
Min Max Recom. Min Max
Wet film per coat (microns) 145 590 235 Air Temperature 10°C 45°C
Dry film per coat (microns) 125 500 200 Substrate Surface Temperature 10°C 45°C
Relative Humidity 85%
Concrete Moisture Content <10%

SOLIDS BY VOLUME 85% (White/Light Base) POT LIFE 2 Hours (20L, 25°C)
VOC LEVEL <140 g/L (White/Light Base, untinted)

Drying characteristics at 200 microns dry film thickness


Overcoat
Temperature Humidity Touch Handle Full Cure Min Max

25° C 50% 5 Hours 24 Hours 7 Days 24 Hours 48 Hours

TYPICAL SPREADING RATE AT RECOMMENDED A spreading rate of 4.2 sq. metres per litre corresponds to 200
DRY FILM BUILD microns dry film thickness assuming no losses.
Practical spreading rates will vary depending on such factors as
method and conditions of application and surface roughness.

Fast Hardener
COATING THICKNESS APPLICATION CONDITIONS
Min Max Recom. Min Max
Wet film per coat (microns) 145 590 235 Air Temperature 10°C 45°C
Dry film per coat (microns) 125 500 200 Substrate Surface Temperature 10°C 45°C
Relative Humidity 85%
Concrete Moisture Content <10%

SOLIDS BY VOLUME 85% (White/Light Base) POT LIFE 2 Hours (20L, 25°C)
VOC LEVEL <140 g/L (White/Light Base, untinted)

Drying characteristics at 200 microns dry film thickness


Overcoat
Temperature Humidity Touch Handle Full Cure Min Max

15° C 50% 14 Hours 28 Hours 7 Days 24 Hours 48 Hours


25° C 50% 6 Hours 14 Hours 7 Days 13 Hours 48 Hours

TYPICAL SPREADING RATE AT RECOMMENDED A spreading rate of 4.2 sq. metres per litre corresponds to 200
DRY FILM BUILD microns dry film thickness assuming no losses.
Practical spreading rates will vary depending on such factors as
method and conditions of application and surface roughness.
These figures are given as a guide only, as ventilation, film thickness, humidity, thinning and other factors will influence the rate of drying.
Use of fast or low temperature hardeners may result in a reduction of gloss level.
If the maximum overcoat interval is exceeded then the surface MUST be abraded to ensure maximum intercoat adhesion.

TYPICAL SYSTEMS
(The typical systems are offered as a guide only and are not to be used as a specification. It is recommended that the specific needs of a project
be discussed with a Dulux Protective Coatings Consultant.)

SURFACE PREPARATION GUIDE SYSTEM DRY FILM THICKNESS


STEEL Abrasive blast AS1627.4 Class 2.5 1st Coat DUREBILD HSE 200 - 500 Microns

1st Coat ZINCANODE 402 75 Microns


2nd Coat DUREBILD HSE 200 Microns
1st Coat DUREPON P14 75 Microns
2nd Coat DUREBILD HSE 200 Microns
CONCRETE Clean surface to remove contaminants. 1st Coat DUREBILD HSE 200 Microns
Diamond grind, track or light-shot blast. 2nd Coat DUREBILD HSE 200 Microns
Remove dust.

June 2010 Page 2 of 3 PC 230


DUREBILD® HSE
SURFACE PREPARATION Steel:
Round off all rough welds, sharp edges and remove weld spatter. Remove grease, oil and other
contaminants in accordance with AS1627.1. For steel substrates, abrasive blast clean to a minimum of
AS1627.4 Class 2.5 with a blast profile of 40-70 microns.
Concrete:
Remove all laitance, form release, curing compounds, oil, grease and other surface contaminants.
Diamond grind, track or light shot-blast to provide suitable profile. Remove all dust by vacuum cleaning.
Fill any large voids exposed using Luxepoxy Filler. Cement based substrates should be at least 21 days
old before coating.
APPLICATION Stir each can thoroughly until the contents are uniform. Use of a power mixer is recommended. Mix the
contents of both packs together thoroughly using a power mixer and allow to stand for 10 minutes. Remix
thoroughly before using.
BRUSH/ROLLER Recommended for brush application only for spot patching on rivets, seams, etc. Roller application
suitable for use on concrete floors by applying even coats of mixed material to the prepared surface. Thin
if necessary with up to 50ml/litre with Dulux Epoxy Thinner (920-08925) to ease application. When
brushing and rolling additional coats may be required to attain the specified thickness.
CONVENTIONAL SPRAY Thinning is not normally required but up to 50ml/litre with Dulux  Epoxy Thinner (920-08925) may be
used to aid atomisation. Apply in multiple wet coats overlapping each pass 50%.
Typical Set-up
Graco Delta Gun: 1.8mm (239543)
Pressure at Pot: 70-100 kPa (10-15 p.s.i.)
Pressure at Gun: 380-410 kPa (55-60 p.s.i.)
AIRLESS SPRAY Standard airless spray equipment such as a Graco Xtreme 56:1 with a fluid tip of 19-21 thou (0.48-
0.53mm) and an air supply capable of delivering 550-690 kPa (80-100 p.s.i.) at the pump. Thinning is not
normally required but up to 50 ml/litre of Dulux Epoxy Thinner (920-08925) may be used to aid
atomisation.
PRECAUTIONS This is an industrial product designed for use by experienced Protective Coating applicators. Where
conditions may require variation from the recommendations on this Product Data Sheet contact your
nearest Dulux representative for advice prior to painting. Do not apply in conditions outside the
parameters stated in this document without the express written consent of Dulux  Australia. Freshly
mixed material must not be added to material that has been mixed for some time. The rate of cure is
dependent upon temperature. Do not apply at temperatures below 10°C. Do not apply at relative
humidity above 85% or when the surface is less than 3°C above the dewpoint. When applying this
product to broad surfaces such as floors use only one application method to avoid colour variation or
streaking. Use of fast or low temperature hardeners may result in a reduction of gloss level.

CLEAN UP Clean all equipment with Dulux Epoxy Thinner (920-08925) immediately after use.
OVERCOATING Aged coating should be tested for lifting by a method appropriate for the coating thickness, for example
‘X’ cut or cross-hatch methods. If it lifts, remove it. The surface must be free of oil, grease and other
contaminants. High-pressure water wash at 8.3 to 10.3 MPa (1,200 - 1,500 p.s.i.) to remove loosely
adhering chalk and dust. Abrasion may be required depending on surface condition. If the maximum
overcoat interval is exceeded then the surface MUST be abraded to ensure maximum intercoat
adhesion.
SAFETY PRECAUTIONS Read Data Sheet, Material Safety Data Sheet and any precautionary labels on containers.
STORAGE Store as required for a flammable liquid Class 3 in a bunded area under cover. Store in well-ventilated
area away from sources of heat or ignition. Keep containers closed at all times.
HANDLING As with any chemical, ingestion, inhalation and prolonged or repeated skin contact should be avoided by
good occupational work practice. Eye protection approved to AS1337 should be worn where there is a
risk of splashes entering the eyes. Always wash hands before smoking, eating, drinking or using the
toilet.
USING Use with good ventilation and avoid inhalation of spray mists and fumes. If risk of inhalation of spray
mists exists, wear combined organic vapour/particulate respirator. When spray painting, users should
comply with the provisions of the respective State Spray Painting Regulations.
FLAMMABILITY This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO
NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.
WELDING Avoid inhalation of fumes if welding surfaces coated with this paint. Grind off coating before welding.
MATERIAL SAFETY DATA SHEET is available from Customer Service (132377) or www.duluxprotectivecoatings.com.au
Dulux Protective Coatings a division of DuluxGroup (Australia) Pty Ltd PACKAGING Available in 20 litre packs
1956 Dandenong Road, Clayton 3168 TRANSPORTATION WEIGHT 1.28 kg/litre (Average of components)
A.B.N. 67 000 049 427 DANGEROUS GOODS Part A: Class 3 UN 1263
Dulux, Durebild, Zincanode and Durepon are registered trademarks. DuluxGroup is a
Part B: Class 3 UN 3066
trademark.
Any advice, recommendation, information, assistance or service provided by DULUX Australia in relation to goods manufactured by it or their use and
application is given in good faith and is believed by Dulux to be appropriate and reliable. However, any advice, recommendation, information, assistance or
service provided by Dulux is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right
entitlements and remedies conferred upon any person or the liabilities imposed upon Dulux by any condition or warranty implied by Commonwealth, State or
Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Products can be expected to perform as indicated in this sheet so
long as applications and application procedures are as recommended. Specific advice should be sought from Dulux for application in coastal areas and for
large projects to ensure proper performance.

June 2010 Page 3 of 3 PC 230

You might also like