Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

4138 ECA450.nox PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ECA 450

Combustion Eff ciency & Environmental Analyzer

Combustion &
Environmental Analyzers

“Unlike any other industrial grade combustion eff ciency and environmental analyzer on the market
today, the ECA 450 conducts accurate combustion and emissions tests that will help you meet
environmental regulations and ensure your equipment is burning eff ciently.”

Modular Sensor
Compartment lets you
add sensors as your EPA/ETV Test Verif ed
needs grow Performance

Simple, menu-driven setups


that deliver the data you want
in the format you want

Built-in printer

Downloads test
results to PC

Stores over
1,000 test records

Large, easy to read data display


that is visible from wide angles

1) Carbon Monoxide (High)


2) NO Sensor
3) NO2 Sensor
4) SO2 Sensor
5) Combustible Sensor

Headquarters: 621 Hunt Valley Circle, New Kensington, PA 15068 U.S.A.


Phone: 1-800-736-4666 Canada: 1-800-328-5217 E-Mail: help@MyBacharach.com Website: www.MyBacharach.com
TECHNICAL DATA Applications
Measurements & Ranges The ECA 450 is ideal for professionals concerned about combustion
Oxygen 0.1 to 20.9% eff ciency, environmental compliance, or both. It enables plant
Carbon Monoxide
(hydrogen compensated)
0 to 4000 ppm
(hydrogen compensated)
maintenance engineers and managers, industrial boiler/furnace service
Carbon Monoxide (high)* 4001 to 80000 ppm
technicians, energy coordinators, compliance off cers, environmental
Nitric Oxide* 0 to 3500 ppm auditors and safety managers to ensure that industrial equipment is
Nitrogen Dioxide* 0 to 500 ppm burning eff ciently while environmental regulations are being met.
Sulfur Dioxide* 0 to 4000 ppm
Combustibles* 0 to 5.00% (application dependent)
Stack Temperature -4 to 2400 degrees F (-20 to 1215°C)
Primary/Ambient Temperature -4 to 999 degrees F (-20 to 999°C)
ORDERING INFORMATION
Pressure/Draft -27.7 to 27.7 inches of H2O
Calculations & Ranges PART NO. DESCRIPTION
Combustion Eff ciency 0.1 to 100.0% 24-7221 Base Unit (O2, CO, Ts, Ta, DP)
Excess Air 1.0 to 250%
24-8400 NOX Kit with NO / NO2 sensors and compact sample conditioner
Carbon Dioxide (dry basis) 0 to fuel dependent maximum
NOX (NOX=NO+NO2) 0 to 4000 ppm 24-8401 NOX and SOX Kit with NO, NOX and SO2 sensors and compact
NOX referenced to % O2 0 to 17000 ppm sample conditioner
CO referenced to % O2 0 to 99999 ppm PART NO. REPLACEMENT SENSORS
NO referenced to % O2 0 to 14900 ppm 24-0788 O2 Sensor
NO2 referenced to % O2 0 to 2100 ppm
24-0789 CO (low) Sensor
SOX referenced to % O2 0 to 17000 ppm
Accuracy
24-0997 CO (high) Sensor
Oxygen ± 0.3% O2 on practical concentration of f ue gas 24-0881 NO Sensor
Stack or Flue Gas Temp. ± 4°F between 32 and 255°F 24-1055 Combustible Sensor
(± 2°C between 0 and 124°C)
24-1027 NO2 Sensor
± 6°F between 286 and 480°F
(± 3°C between 125 and 249°C) 24-0998 SO2 Sensor (requires NO2 option)
± 8°F between 481 and 752°F PART NO. ACCESSORIES
(± 4°C between 250 and 400°C) 07-1644 Filters (pkg. of 3)
Primary-air/ambient Temp. ± 2°F between 32 and 212°F 24-7059 Calibration Kit (does not include gas)
(± 1°C between 0 and 100°C)
104-1800 Thermocouple Wand Extension, 5 feet
Pressure Draft ± 2% of reading or ± .02 in wc whichever is greater
104-4027 Serial Cable DB.9M to DB.9F
CO ± 5% of reading or ± 10 ppm whichever is greater between
0-2000 ppm CO 24-0980 Printer Paper (5 rolls)
± 10% of reading between 2001 to 40000 ppm CO
The maximum operating temperature for probes included in 24-7221, 24-7224, 24-7223,
NO ± 5% of reading or ± 5 ppm whichever is greater between
0-2000 ppm NO
24-3024 and 24-3025 is 1472°F (800°C). The maximum operating temperature for high
temperature probes 24-3035, 24-3036 and 24-3037 is 2000°F (1093°C).
NO2 ± 5% of reading or ± 5 ppm whichever is greater between
0-500 ppm NO2
SO2 ± 5% of reading or ± 10 ppm whichever is greater between
0-2000 ppm SO2
HC ± 5% of full scale
Selectable Fuels Natural Gas, Oil #2, Oil #4, Oil #5, Oil #6,
Propane, Coal, Wood, Kerosene, Bagasse
Power Universal AC adapter and an internal battery pack. Adapter will
Distributed By:
accept input voltages from 100 to 240V. Fully charged battery
pack provides a minimum of 8 hrs of operation
Pumps & Probe Two pumps are included. The f rst pump supplies gas sample
to the sensors. The second pump supplies fresh air to purge
the low range CO sensor when CO levels exceed 4000 ppm.
Probe includes a standard probe and hose assembly equipped
with a water trap, particulate f lter, probe stop, 15 feet of hose,
and 12-inch probe tube.
Size 13.5” H x 18.5” W x 9” D Bacharach is a registered trademark of Bacharach, Inc.
Weight 25 lbs. (11.34 kg) © 2010, Bacharach, Inc. All rights reserved. All information herein is subject to verif cation.
Product Bulletin-4144 01/10 10M PT
Warranty 1 year, extended warranty available
Printed in U.S.A.
* Optional

Headquarters: 621 Hunt Valley Circle, New Kensington, PA 15068 U.S.A.


Phone: 1-800-736-4666 Canada: 1-800-328-5217 E-Mail: help@MyBacharach.com Website: www.MyBacharach.com

You might also like