CLUSTER DRIVE

1.Test Setup
Voice Call Test Number:- +919867092154
Video call Test Number:- +919867092154

1.1 Mobility Tests at Cluster Level

This test is performed for the following Reasons:-

1. Check the Idle Coverage and pilot pollution through Scanner


2. Check for call drops and call block cases
3. Check Data downloading speed through an FTP Server

MS1,MS2:- Locked on 3G

Equipment Configuration:-

Device
ID Model Phone Number SIM Card Id IMSI Test
MS1 Nokia N95 Voice (1)

MS2 Nokia95 Video (2)

MS3 Star Hub HSDPA (3)

Scanner PC Tel LX NA NA NA Scanner(4)

(1) MS1(Voice):- 60Sec voice Call with an Interval of 15Sec.


Time interval between dropped or blocked calls 15 sec
Repetation period= 9999
(2) MS2(Video):- 60Sec video Call with an Interval of 15Sec.
Time interval between dropped or blocked calls 15 sec
Repetation period= 9999
(3) MS3(HSDPA):- (IP address: 10.49.12.141).
User Name:- yogesh
Password:- 123456
File Name: UPDATED SITE DATA 10NOV.zip
PS Call Duration: 60sec
Time interval between normal release or dropped session 15 sec
Repetation period= 9999
(4) Scanner:- PCTel Scanner with an Inbuilt GPS.
1.2 Mobility Tests in Selected Clusters
(IRAT Tests at Selected Locations in 3G Border)

This test is performed for the following reasons:-

1. Check the voice Handovers(3G to 2G and 2G to 3G) at 3 Locations near the cluster
border.
2. Check the Data Handovers(3G to 2G and 2G to 3G) at 3 Locations near the cluster
border.

MS1:- Dual Mode

Equipment Configuration:-

Device
ID Model Phone Number SIM Card Id IMSI Test
MS1 Nokia N95 Voice (1)

MS2 Star Hub HSDPA (2)

GPS HOLUX NA NA NA GPS (3)

(1) MS1(Voice):- 9999sec Long Call


Time interval between dropped or blocked calls 15 sec
(2)MS2(HSDPA):- 9999sec Data Call
(IP address: 10.49.12.141).
User Name:- yogesh
Password:- 123456
File Name: UPDATED SITE DATA 10NOV.zip
PS Call Duration: 9999sec
Time interval between dropped session 15 sec

Page 2 of 3
1.3 Stationary Tests in Selected Clusters

MS1:- Locked on 3G

This test is performed for the following reasons:-

1. Check Video Call Statistics from one mobile to another

Equipment Configuration:-

Device
ID Model Phone Number SIM Card Id IMSI Test
MS1 Nokia N95 Video (1)
GPS HOLUX NA NA NA GPS (2)

(1) MS1(Video):- 30Sec Video Call with an Interval of 15Sec to another mobile.
Time interval between normal release and after dropped or blocked calls 15 sec

Convention for Saving Log Files:-


DT_ CircleName _ClusterXX_##.gen [## = 00-99]

Eg.
DT_ Mumbai _Cluster24_01.txt

Log file needs to be recorded before running the Command Sequence.


Log file shouldn’t be paused during the drive.
Over lapping of roads during drive must be avoided.
Command sequence shouldnt be stopped during logfile recording.

Page 3 of 3