Electric Actuated Butterfly Valves: Features
Electric Actuated Butterfly Valves: Features
Electric Actuated Butterfly Valves: Features
Features
Lug body butterfly valve with ISO5211 direct mount actuator
Unique wave line seat reduces torque and extends seal life
Ductile iron body with 3-layer epoxy coating and 316SS disc
External LED power on and diagnostic light
Long life brushless motor
IP67 polyamide weatherproof enclosure with UV protection
Multi-voltage capable with auto-voltage sensing
Electronic torque limiter protects against valve jams
Anti-condensation heater
Manual override with visual valve position indicator
Electrical connections via external DIN plugs
Auxiliary limit switches to confirm open/closed valve position
Applications Description
Electric actuated Lug body butterfly valves are used to control the flow Electric operated direct mount butterfly valves
of water, oils, air, vacuum and other media compatible with the with epoxy- coated ductile iron lug body are
materials of construction. Actuator designed for 75% duty cycle. designed for commercial and industrial
applications. Lug type valves have threaded
Three seal options are available: holes in valve body for mounting. Valve
EPDM: Water service, other compatible media. mounts between two standard ANSI/ASME
Class 125/ 150 flanges. Seat to flange seal
NBR (Buna-N): Oils, air, vacuum, other compatible media.
eliminates the need for flange gaskets. Disc
FPM (Viton): Hydrocarbons, oils, other compatible chemicals/media. is precision machined 316SS. Two piece
stem and disc design enhances the flow
Operation capacity and reduces turbulence.
Electric actuated valve uses power-to-open and power-to-close,
stays in the last known position with power failure. On receipt of
a continuous voltage signal, the motor runs and via a flat gear
system rotates the disc 90º. The motor is automatically stopped
by internal cams striking limit switches. On receipt of a reversing
Approvals
continuous signal, the motor turns in the opposite direction Actuators
reversing the valve position. • CE mark conforming to:
- Machinery directive
Construction
- Low voltage directive
Valve Body 3-layer Epoxy/Epoxy/PUR coated ductile iron
- EMC Compatibility directive
Disc 316 stainless steel CF8M
• ISO5211 valve mounting
Disc Seat/Liner Options: EPDM, NBR (Buna-N), FPM (Viton)
Valves
Stem/Stem Seals 420 stainless steel / V-ring (same material as seat)
Design complies with API-609, MSS SP-67
Actuator Enclosure Anti-corrosive Polyamide, UV protection
Tests per API-598, AWWA C502-87
Manual Override/Position Indicator Glass filled Polyamide / Clear Polyamide Dome
CE according to PED 97/23/EC, ISO5208
Auxiliary Limit Switches 2 x SPST 3A@125/250VAC, 30VDC resistive load
Construction Features
Anti-corrosive polyamide
enclosure with UV protection
Heavy duty brushless motor
5627
562726C 6 6.00 2243 230 Air, Oil, Vacuum 58 0.8 0.5 3.3 2.7
562742C 2 2.00 124 230 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
562743C 2-1/2 2.50 247 230 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
562744C 3 3.00 470 230 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
562745C 4 4.00 929 230 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
Lug Body FPM (Viton) Seals: 24v-240v AC or DC
562747C 6 6.00 2243 230 Hydrocarbon, Oil 58 0.8 0.5 3.3 2.7
Cv is the GPM of water at 60º F that will pass through the valve with 1 PSI pressure drop
* Consult compatibility chart for other media. Suitable for vacuum up to 29 inHg
Models with 240 volts are single phase
5627
562726C 6 150 1929 16 Air, Oil, Vacuum 58 0.8 0.5 3.3 2.7
Lug Body FPM (Viton) Seals: 24v-240v AC or DC
562742C 2 50 107 16 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
562743C 2-1/2 65 212 16 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
562744C 3 80 404 16 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
562745C 4 100 799 16 Hydrocarbon, Oil 13 0.43 0.21 1.98 1.63
Lug Body FPM (Viton) Seals: 24v-240v AC or DC
562747C 6 150 1929 16 Hydrocarbon, Oil 58 0.8 0.5 3.3 2.7
Cv is the GPM of water at 60º F that will pass through the valve with 1 PSI pressure drop
* Consult compatibility chart for other media. Suitable for vacuum up to 29 inHg
Models with 240 volts are single phase
5627
Position Confirmation
Power Connection Limit Switches
1 2 Earth
Ground
1 2
3
3
OPEN CLOSED
LS1 LS2
Customer OPEN CLOSED
Supplied Signal Signal
Switch
N/- Power COM LS1 LS2
L/+ VAC or VDC L/+ N/- N/-
Function: ON-OFF version Function: ON-OFF version with BSR option Function: Position
Power Connections Wiring is the same as standard ON-OFF version. confirmation limit switches
Power to PIN 1 and 2 Power to open, power to close - maintain power to trickle Dry contact 3A @ 125/250
- actuator CLOSED (pos 1) charge the battery system in either open or closed position. VAC, 30VDC resistive load
Power to PIN 1 and 3 Actuator sent by battery power to failsafe position with pow- PIN 1 (COM) and 2 to confirm
- actuator OPEN (pos 2) er failure. actuator is closed
Stays in last known position Actuator returns to pre-failure position on power resumption. PIN 1 (COM) and 3 to confirm
with loss of power. actuator is open
5627
LS1 LS2
OPEN CLOSED
Signal Signal
Standard operation: 4mA or 0V = actuator closed, 20mA or 10V = actuator open (can be set- Dry contact 3A @ 125/250
up reverse acting). VAC, 30VDC resistive load
Actuator closes with loss of control signal, stays in last known position with loss of main pow- PIN 1 (COM) and 2 to confirm
er. actuator is closed
Output monitoring signal (in same format as supply signal) provided as standard. PIN 1 (COM) and 3 to confirm
actuator is open
5627
Dimensions:
A F
J
ØB ØD
ØC
ØE
ØB ØD
ØC