BDF - AUT - 16 - 001 - Eng - TP 6 Poles To 8 Poles Motors - OPD and DSC - Rev1-1 PDF
BDF - AUT - 16 - 001 - Eng - TP 6 Poles To 8 Poles Motors - OPD and DSC - Rev1-1 PDF
BDF - AUT - 16 - 001 - Eng - TP 6 Poles To 8 Poles Motors - OPD and DSC - Rev1-1 PDF
DSC Support
Nome file: BDF_AUT_16_001_eng - TP 6 poles to 8 poles motors - OPD and DSC - rev1
BDF INDUSTRIES S.p.A. Phone +39 0444 286100 Capitale Sociale € 3.900.000 i.v.
Sede legale e operativa: Fax +39 0444 286299 Società Unipersonale soggetta a direzione
Viale dell'Industria, 40 E-mail: bdf@bdf.it e coordinamento di BDF Holding S.p.A.
36100 Vicenza - Italy www.bdf.it iscritta al Reg. Imp. VI 01636010249
Reg. Imp. VI, C.F. e P.I.: 03371360243
Page 2 / 10
Index
1 Replacement warning................................................................................................................................ 3
2 Parameters and procedure for OPD and OPDE ......................................................................................... 4
2.1 E-47-M168B (6 poles) to E-47-M368B (8 poles) ................................................................................ 4
2.2 E-47-M282 (6 poles) to E-47-M382 (8 poles) .................................................................................... 4
2.3 E-47-M233D/24 (6 poles) to E-47-M333D/24 (8 poles) .................................................................... 5
2.4 E-47-M132A (6 poles) to E-47-M332A (8 poles)................................................................................ 5
2.5 E-47-M131A (6 poles) to E-47-M331A (8 poles)................................................................................ 5
2.6 E-47-M233A (6 poles) to E-47-M333A (8 poles)................................................................................ 6
2.7 Procedure to change parameters ...................................................................................................... 7
3 Parameters and procedure for DSC ........................................................................................................... 8
3.1 E-47-M168B (6 poles) to E-47-M368B (8 poles) ................................................................................ 8
3.2 E-47-M233D/24 (6 poles) to E-47-M333D/24 (8 poles) .................................................................... 8
3.3 E-47-M132A (6 poles) to E-47-M332A (8 poles)................................................................................ 8
3.4 E-47-M131A (6 poles) to E-47-M331A (8 poles)................................................................................ 9
3.5 E-47-M233A (6 poles) to E-47-M333A (8 poles)................................................................................ 9
3.6 Procedure to change parameters .................................................................................................... 10
1 Replacement warning
The 6 poles motors listed in this document are not more supplied.
New motors (8 poles) are available for maintenance / spare parts; some parameters have to be modified in
the drive, in case of replacement from 6 poles motor to 8 poles motor.
This document explains the procedure and the parameters to change.
WARNING: this procedure is valid for OPD and OPDE drives and for DSC drives.
Here below the association table between 6 poles motors and equivalent 8 poles motors
Plunger
E-47-M368B TOP 143P E-47-M168B BLQ 86x27
Shear parallel
E-47-M382 NGBE-96M E-47-M282 BLQ 45 M 3T Lifting Tube
Shear angular
E-47-M333D/24 NGBE 123M E-47-M233D/24 BLQ 65 L 3X ∅24 Gob Distributor SGD3x
Take-Out
Mechanical Feeder
E-47-M332A NGBE 143M E-47-M132A BLQ 83 M 2T
Conveyor
E-47-M331A NGBE 143L E-47-M131A BLQ 83 P 15 Gob Distributor
Transfer
Cross Conveyor
E-47-M333A NGBE 123M E-47-M233A BLQ 65 L 3T ∅19 Rotation Tube
Stacker – Rotation
Stacker – Lifting (without brakes)
Remarks: following motors are 8 poles motors but they don’t need for any parameter change in the drive
MOTORS (8 poles)
MECHANISM
BDF CODE MOTOR CODE
5A LIFTING TUBE
OPD 8 POLE
P60 95
P61 92
P63 3000
P67 8
P75 60
P91 120
*
P78 2.8
P76 10.6
P77 38.6
C90 1
C63 1
* Attention! Check the sign of P75 in your Drive and keep the same. Change only the value.
This procedure is valid for OPD and OPDE drives and explains how to change the parameters of the drive by
means of the drive keyboard.
The procedure here below refers to OPD drives, it’s valid also for OPDE considering the keypad buttons as
shown in the below table:
Before to change the values of the parameters the access code has to be set (P60=95)
For an explanation on using the keypad refer to the user manual OPD / OPDE Cod.
MW00101E00_BRUSHLESS V_4.1 EN.
This procedure is valid for DSC drives and explains how to change the parameters of the drive by means of
the drive keyboard.
Before to change the values of the parameters the access code has to be set (P50=95)
For an explanation on using the keypad refer to the user manual DSC Cod. DSC_MAN_07_EN