Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
481 views4 pages

HPC Calculation Sheet

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 4

Sawytech Engineering Services Project Amarwada - Ramgarh Road

13, Yeswant Colony


Opp. Yeswant Club, Indore, Subject HPC at Km 0+917
E-mail:- sawytech@yahoo.co.in
Ph. No.: - +91-94253-15855 Element Hydraulic Calculations

Client :- E.E. M.P.P.W.D., Chhindwada Contractor M/s Rajaram Construction

Hydraulic Calculation
1 Chainage 0+917
2 Description of Catchment 0.08 sq. km.
3 Pipe Diameter Proposed 1 0 M.
1.0 M

Procedure Adopted

1 Discharge Calculation:-
a) Discharge from Dicken's Formula
3/4
Dicken's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.2 of IRC:SP:13-2004 ,C = 14-19 where
C= 14
the annual rain fall is more than 120 cm.)
M= 0.08 sq.km. (The area of catchment in sq.km)
3
Q = 2.11 m /s

b) Discharge from Ryve's Formula


2/3
Ryve's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.3 of IRC:SP:13-2004, C = 10.0
C= 10
for limited areas near the hills)
M= 0.08
0 08 sq.km.
sq km (The area of catchment in sq
sq.km)
km)
3
Q= 1.86 m /s

C) No. of pipe required

3
Max Discharge 2.11 M /sec (Adopt the Max. value of discharge from above two method)

Proposal 1 0 M Dia NP4 Hume Pipe is Prposed to Provide


1.0

Length of Pipe L= 12.5 M

3
Max discharge passing through pipe = 3.2X0.7853= 2.51 M /Sec

D) Hence provide one row of 1000 mm dia pipe is suffucient


Sawytech Engineering Services Project Amarwada - Ramgarh Road
13, Yeswant Colony
Opp. Yeswant Club, Indore, Subject HPC at Km 1+950
E-mail:- sawytech@yahoo.co.in
Ph. No.: - +91-94253-15855 Element Hydraulic Calculations

Client :- E.E. M.P.P.W.D., Chhindwada Contractor M/s Rajaram Construction

Hydraulic Calculation
1 Chainage 1+950
2 Description of Catchment 0.075 sq. km.
3 Pipe Diameter Proposed 1.0 M.

Procedure Adopted

1 Discharge Calculation:-
a) Discharge from Dicken's Formula
3/4
Dicken's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.2 of IRC:SP:13-2004 ,C = 14-19 where
C= 14
the annual rain fall is more than 120 cm.)
M= 0.075 sq.km. (The area of catchment in sq.km)
3
Q = 2.01 m /s

b) Discharge from Ryve's Formula


2/3
Ryve's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.3 of IRC:SP:13-2004, C = 10.0
C= 10
for limited areas near the hills)
M= 0.075 sq.km. (The area of catchment in sq.km)
3
Q= 1.78 m /s

C) No. of pipe required

3
Max Discharge 2.01 M /sec (Adopt the Max. value of discharge from above two method)

Proposal 1.0 M Dia NP4 Hume Pipe is Prposed to Provide

Length of Pipe L= 12.5 M

3
Max discharge passing through pipe = 3.0X0.7853= 2.35 M /Sec

D) Hence provide one row of 1000 mm dia pipe is suffucient


Sawytech Engineering Services Project Amarwada - Ramgarh Road
13, Yeswant Colony
Opp. Yeswant Club, Indore, Subject HPC at Km 2+2550
E-mail:- sawytech@yahoo.co.in
Ph. No.: - +91-94253-15855 Element Hydraulic Calculations

Client :- E.E. M.P.P.W.D., Chhindwada Contractor M/s Rajaram Construction

Hydraulic Calculation
1 Chainage 2+2250
2 Description of Catchment 0.085 sq. km.
3 Pipe Diameter Proposed 1.0 M.

Procedure Adopted

1 Discharge Calculation:-
a) Discharge from Dicken's Formula
3/4
Dicken's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.2 of IRC:SP:13-2004 ,C = 14-19
C= 14
where the annual rain fall is more than 120 cm.)
M= 0.085 sq.km. (The area of catchment in sq.km)
3
Q = 2.20 m /s

b) Discharge from Ryve's Formula


Ryve's Discharge 'Q' = CM2/3
Where,
3
Q = the peak run-off in m /s
(Clause 4.3 of IRC:SP:13-2004, C = 10.0
C= 10
for limited areas near the hills)
M= 0.085 sq.km. (The area of catchment in sq.km)
3
Q= 1.93 m /s

C) No. of pipe required

Max Discharge 2.20 M3/sec (Adopt the Max. value of discharge from above two method)

Proposal 1.0 M Dia NP4 Hume Pipe is Prposed to Provide

Length of Pipe L= 12.5 M

3
Max discharge passing through pipe = 3.3X0.7853= 2.60 M /Sec

D) Hence provide one row of 1000 mm dia pipe is suffucient


Sawytech Engineering Services Project Amarwada - Ramgarh Road
13, Yeswant Colony
Opp. Yeswant Club, Indore, Subject HPC at Km 4+150
E-mail:- sawytech@yahoo.co.in
Ph. No.: - +91-94253-15855 Element Hydraulic Calculations

Client :- E.E. M.P.P.W.D., Chhindwada Contractor M/s Rajaram Construction

Hydraulic Calculation
1 Chainage 4+150
2 Description of Catchment 0.087 sq. km.
3 Pipe Diameter Proposed 1.0 M.

Procedure Adopted

1 Discharge Calculation:-
a) Discharge from Dicken's Formula
3/4
Dicken's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.2 of IRC:SP:13-2004 ,C = 14-19 where
C= 14
the annual rain fall is more than 120 cm.)
M= 0.087 sq.km. (The area of catchment in sq.km)
3
Q = 2.24 m /s

b) Discharge from Ryve's Formula


2/3
Ryve's Discharge 'Q' = CM
Where,
3
Q = the peak run-off in m /s
(Clause 4.3 of IRC:SP:13-2004, C = 10.0
C= 10
for limited areas near the hills)
M= 0.087 sq.km. (The area of catchment in sq.km)
3
Q= 1.96 m /s

C) No. of pipe required

3
Max Discharge 2.24 M /sec (Adopt the Max. value of discharge from above two method)

Proposal 1.0 M Dia NP4 Hume Pipe is Prposed to Provide

Length of Pipe L= 12.5 M

3
Max discharge passing through pipe = 3.5X0.7853= 2.74 M /Sec

D) Hence provide one row of 1000 mm dia pipe is suffucient