MC Feed-Through Packers: Remotely Isolate Zones in Marginal or Mature Assets
MC Feed-Through Packers: Remotely Isolate Zones in Marginal or Mature Assets
MC Feed-Through Packers: Remotely Isolate Zones in Marginal or Mature Assets
MC Feed-Through Packers
REMOTELY ISOLATE ZONES IN MARGINAL OR MATURE
ASSETS
14310 V3 rating.
LEVEL 1 CAPABILITY
COMPLETION | Level| 2Intelligent
SOLUTIONS CapabilityCompletions
(if applicable)
Casing Max
Working Required
Mandrel Max Bore Max Differential Working ISO
Tempera- Setting Element
Type Size OD ID Feed Across Pressure 14310
Size Weight ture Pressure Type
Through Element Rating
in. lb/ft in. in. in. psi psi °F psi
80 to 275 3500 Nitrile
23 3 1/2 6.18 2.817
70 to 284 4000 HNBR
7 8 5000
2400
Production Packer
26-29 3 1/2
2.817 3000 80 to 275 Nitrile
5.992
2963 Nitrile
5000 80 to 285 V3
29 3 1/2 5.995 2500 HNBR
4000 Nitrile
9 5/8 8 5000 80 to 275
3 1/2 2.75 4715 HNBR
5000
47 8.44 75 to 275 4000 HNBR
5 1/2 13-17 2 7/8 4.7 2.399 6 1500 5000 75 to 275 3000 Nitrile
Packer
Sales of Halliburton products and services will be in accord solely with the terms and conditions
contained in the contract between Halliburton and the customer that is applicable to the sale.