Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MC Feed-Through Packers: Remotely Isolate Zones in Marginal or Mature Assets

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

LEVEL 1 CAPABILITY

COMPLETION | Level| 2Intelligent


SOLUTIONS CapabilityCompletions
(if applicable)

MC Feed-Through Packers
REMOTELY ISOLATE ZONES IN MARGINAL OR MATURE
ASSETS

OVERVIEW SETTING MECHANISM


Halliburton MC packers, designed for Both MC production packers and MC
both production (MC-1) and isolation isolation packers are tubing-pressure
(MC-0) applications (no slips), are single- set. Incorporating a hydraulically
string, cased-hole, retrievable packers activated interlock system, the MC
primarily designed for use in SmartWell® packers can be adjusted externally prior
completions in marginal or mature to running in the hole. The interlock
assets. system allows the packers to be run in
highly deviated wells, eliminating the
Both MC production packers and MC
risk of presetting caused by casing.
isolation packers have the facility to feed
through up to eight hydraulic or electrical
RETRIEVAL MECHANISM
control lines, allowing communication
with other SmartWell equipment The MC-1 production packer is released
without compromising the integrity of by the “shift and pull” method. Once
the isolated zones. In some instances, the primary packer is released, the MC-0
the MC production packer has been isolation packer can be retrieved simply
used as an isolation packer below the by overpull; there is no release feature.
primary HF-1 production packer.
PACKING ELEMENT
FEATURES The MC packer is fitted with a state-of-
»» Simple, cost-effective design the-art nitrile, HNBR, or Viton packing
»» Feed-through for up to eight control elements similar to those used in
lines the high performance HF packer. This
»» Tubing set element offers robustness and excellent
»» Nitrile, HNBR, and Viton® packing sealing properties.
element
NOMINAL CONDITIONS
BENEFITS MC production and isolation packers
»» Apply SmartWell technology in are designed for use in wells with the
marginal or mature assets following normal conditions:
»» Maintain zonal integrity »» BHP < 5,000 psi
»» Perform high pressure/tubing pressure »» Negligible H²S and CO²
testing »» BHT < 275˚F
»» Achieve communication with laser »» ΔP 5,000 psi
tools
RELIABILITY
Both MC production and isolation
packers have been qualified to an ISO
HAL122117

14310 V3 rating.
LEVEL 1 CAPABILITY
COMPLETION | Level| 2Intelligent
SOLUTIONS CapabilityCompletions
(if applicable)

Retrievable Feed-Through MC Packers

Casing Max
Working Required
Mandrel Max Bore Max Differential Working ISO
Tempera- Setting Element
Type Size OD ID Feed Across Pressure 14310
Size Weight ture Pressure Type
Through Element Rating
in. lb/ft in. in. in. psi psi °F psi
80 to 275 3500 Nitrile
23 3 1/2 6.18 2.817
70 to 284 4000 HNBR

2.817 2500 FKM

26 3 1/2 5.992 5000 75 to 275

2.812 4000 Nitrile

7 8 5000

5.987 70 to 285 Nitrile

2400
Production Packer

26-29 3 1/2
2.817 3000 80 to 275 Nitrile
5.992

2963 Nitrile
5000 80 to 285 V3
29 3 1/2 5.995 2500 HNBR

4 1/2 3.81 5000 4500 HNBR


40 8.614 80 to 275
5 1/2 4.58 3500 3500 HNBR

43.5 4 1/2 8.515 3.82 70 to 275 4000 HNBR

4000 Nitrile
9 5/8 8 5000 80 to 275
3 1/2 2.75 4715 HNBR
5000
47 8.44 75 to 275 4000 HNBR

70 to 285 4000 Nitrile


4 1/2 3.81
80 to 275 4000 HNBR
Isolation

5 1/2 13-17 2 7/8 4.7 2.399 6 1500 5000 75 to 275 3000 Nitrile
Packer

7 26-29 3 1/2 5.98 2.885 8 2500 5000 75 to 275 2400 Nitrile

For more information, contact your local Halliburton representative


or visit us on the web at www.halliburton.com

Sales of Halliburton products and services will be in accord solely with the terms and conditions
contained in the contract between Halliburton and the customer that is applicable to the sale.