SYSTEMS Page Corrugated Wall Ties 9 Rebar Products 24
TMS 402 Building Code 2 Debonded Shear Anchor 14 Reglets 17
L.E.E.D. Information 2 Dovetail Anchors 16 Remedial Ties 26
Masonry to CMU & Concrete 11-12 Dovetail Slots 16 Restoration Tie 26
Masonry to Masonry 13-14 Dowels & Caps 27 Rigid Steel Anchors 13
Masonry to Metal Studs 3-4 Eye Rod Anchors 19 Rod Anchors 19
Masonry to Structural Steel 7-9 Fiberweb™ 27 Rubble Stone Anchors 23
Masonry Wire Ties 13-14 Firewall Anchors 10 Screws 14
Masonry to Wood 9 Flashing Reglets 17 Screw On Stone Anchors 19
Precast Anchors 19-20 Flashings 17 Seismic Anchors 10
Restoration System 26 Flash Trac Flashing System 25 Shelf Angle Inserts 21
Seismic Systems 10 Glass Block Panel Anchors 23 Shims 20
Glass Block Reinforcement 23 Spring Loaded Dowels 20
Materials & Finishes 27 Horseshoe Shims 21 Stone Anchors 19-20
Engineering Guide 28-30 Joist Pin Anchors 9 Strap Anchors 19
Test Data 28-30 Joist Hangers 26 Strap Bolts 19
Anchor Bolts 19 Ladder Wall Reinforcment 23 Steel-Wich® Rebar Positioner 24
Anchor Plates 20 Lateral Support Anchors 13 Structural Steel Anchors 7-9
Anchor Rods 19 Lath Fasteners 18 Termination Bar 17
Angles 20 Lintels 20 Threaded Inserts 25
Band Iron Tighteners 27 Masonry Wall Stabilizing Anchor 21 ThermalClip® Pos-I-Tie® 5
Bent Plates 20 Materials & Finishes 27 Thermal-Grip® Washers 6
Breakaway Firewall Anchors 10 Melt-Away Anchors 10 Thru-Wall Flashing 17, 27
Brick Veneer Anchors 3-4, 9-12 Mesh Ties 13 Tongue & Groove Joints 25
BrickVentTM Moisture Control 22 Metal Lath Ties 13 Triangle Ties 14
Buck Anchors 20 Moisture Control Systems 22 Wall Reinforcement 23
Ceiling Hanger Inserts 27 Original Pos-I-Tie® 3-5 Wall Ties (corrugated) 9
Cell Vents 22 Pin Anchors 19 Wall Ties (Wire) 13-14
Channel Slots 15 Plastic Horseshoe Shims 21 Web Ties 14
Channel Slot Anchors 15 Plastic Square Shims 20 Wedge Inserts 21
Ci Fasteners 18 PlateGripTM Embed Plate Holder 26 Weep-Thru Mortar Delector 22
Column Anchors 7-8 Pos-I-Tie® System 3-6 Weep Tubes and Systems 22
Construction Joints 25 Pos-I-Tie® KeyBolt 6 Weld-On Anchor Rods 8-9
Control Joint Anchors 14 Pos-I-Tie® ThermalClip® 5 Wire Mesh Wall Ties 13
1 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
• Spacing of two-piece 9 ga wire ties and/or 22ga corrugated anchors limited to maximum of one anchor each 2.67
ft2 – all other anchors maximum of one anchor per 3.5 ft2. Maximum spacing 32” horizontally and 25” verically with
additional ties required around openings and near edges.
• Cavity limitations of 4 1/2” from backup to inside of the veneer with all insulation. sheathing, vapor barrier and air space
positioned within the space. Wider cavities require engineering. Minimum air space is 1”. Corrugated sheet metal
anchors cannot be used when the air space exceeds 1”.
• Mortar joint thickness is a minimum of twice the thickness of the embedded anchor/tie. Anchors are embedded at least
1 1/2” into the veneer from the backup with a minimum of 5/8” of mortar from the outside face.
• Continuous single wire joint reinforcement is no longer required in Seismic Zones D, E, and F.
• Exterior wall anchors must be a minimum of Hotdip Galvanized After Fabrication, Epoxy Coated, or Stainless Steel.
Mill Galvanized is for interior use only.
Self Drilling
Steel Stud
Screw Veneer Ties & Anchors
CMU, Concrete,
Concrete/
Wood, Masonry,
CMU Screw
ICF
Dril-It®
Structural Steel
Screw Triangle Wire Tie Seismic Wire Tie Single Wire Tie
3 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92ndYear!
Barrel Sizes:
Overall Length
• 5/8” • 3”
• 1” • 3-1/2”
Sheathing Thickness Barrel Size to Order
• 1-1/2” • 4”
No Sheathing or 1/2” - 5/8” 5/8”
• 2” • 4 1/2”
1” - 1 1/8” 1”
• 2-1/2”
1 1/2” - 1 5/8” 1 1/2”
Longer sizes available
2” - 2 1/8” 2”
2 1/2” - 2 5/8” 2 1/2”
3” - 3 1/8” 3”
ORIGINAL POS-I-TIE® INSTALLATION
3 1/2” - 3 5/8” 3 1/2”
Chuck adapter Sleeve Tool 4” - 4 1/8” 4”
4 1/2” - 4 5/8” 4 1/2”
WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM 4
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
POS-I-TIE® THERMALCLIP®
ThermalClip® Installation
MADE IN USA
Chart courtesy of
Owens Corning, Inc.
Install the Pos-I-Tie® KeyBolt through Pass the large keyhole opening of the Make sure the bend of the stone
the insulation and into the backup wall stone anchor over the head of the Pos- anchor is set in the cutout of the
using a powerdrill and standard 5/16” I-Tie® KeyBolt. Set the stone anchor so stone veneer panel. Tighten the Hex
hex driver. the small keyhole opening sits between Nut to secure the stone anchor to the
the two Hex Nuts. Pos-I-Tie® KeyBolt.
These are typically installed 12” o.c. around the perimeter, and 16” o.c. throughout the sheet.*
Using the Thermal-Grip® over-sized washer with the Original Pos-I-Tie® Veneer Anchoring
System saves time and money, reduces the number of overall penetrations to the insulation,
and reduces the thermal bridging from the cavity to the backup. Thermal-Grip®
Brick Tie
*Check with insulation manufacturer for exact spacing requirements Washer
STRUCTURAL ANCHORS
Steel Types: TMS 402 Building Code allows Mill Galvanized anchors for interior walls and requires Stainless Steel, Epoxy Coated, or Hotdip
Galvanized after Fabrication for exterior walls. Specify accordingly. Non-wire anchors available in 1/8” zinc alloy material for irewall
conditions. See page 18.
7 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
STRUCTURAL ANCHORS
Steel Types: TMS 402 Building Code allows Mill Galvanized anchors for interior walls and requires Stainless Steel, Epoxy Coated, or Hotdip
Galvanized after Fabrication for exterior walls. Specify accordingly. Non-wire anchors available in 1/8” zinc alloy material for irewall
conditions. See page 18.
216 217
198
#216 Wire Type Column Anchor: 3”, #217 Wire Type Column Anchor: #198 Rod-Lock Corrugated Beam
5”, 7”, and 9” lengths from inside of 10” , 12”, 14”, or 16” long from inside Anchor:
lange slot to masonry bend x 3/16” of lange slot to masonry bend x 3/16” 12 gage, 1/8” or 3/16” x 1-1/4” wide
or 1/4” diameter wire. Standard lange or 1/4” diameter wire. Standard lange + 1” bend. Specify overall length of
slot is 1/2” x 2-1/2” . Bend is 2” . Order slot is 1/2” x 2-1/2”. Order by piece. anchor from inside of bend to the end.
by piece. Twist is 2” long. Also available in Zinc
Alloy 710.
321
#321 Corrugated L-Tie:
3” , 5”, 7”, or 9” lengths x 3/4” wide x 14 gage. Adjustment
320
bend is 4” long. NOT available in Stainless Steel
322 322
No. 322 U-Type Tie:
Made to order. Cannot be thicker than 14 gage or wider 320
than 3/4”. NOT available in Stainless Steel 320
STRUCTURAL ANCHORS
Steel Types: TMS 402 Building Code allows Mill Galvanized anchors for interior walls and requires Stainless Steel, Epoxy Coated, or Hotdip
Galvanized after Fabrication for exterior walls. Specify accordingly.
133
317 317-B
315-C Pos-I-Tie®
315-D 132 Wood Screw 187 103-C
The Anchoring Systems shown above can be used for attaching brick veneer to wood stud backups. Using
No. 681-EHH230 Wood Screw, they can be attached to wood studs through exterior plywood sheathing
(See page 14). For more information on these anchors, see pages 3, 11, 12, 15 and 16.
9 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
The majority of our non-wire anchors can be manufactured from Rolled Zinc Alloy 710 material which has a melting
point of 792 degrees. Choose your non-wire anchor from this catalog, specify your required dimensions, and specify
“Rolled Zinc Alloy 710” as the steel type. The Rolled Zinc Alloy 710 material is available in 1/8” and 16 gage thickness only.
The new TMS402 2013 Masonry Building Code no longer requires the continuous wire in the veneer. A SEISMIC TAB
NOTCH CAN BE PROVIDED FOR ANY FLAT HECKMANN ANCHOR UP TO 1/8” THICK. Below are examples of the #361
Dovetail, and #360 Veneer Seismic Anchors.
#370 Seismic Hook Tab: 20 gage clip welded to #316 Triangle Ties, #282 Double Pintle Wire Ties, Pos-I-Tie® Wire Ties,
#314 Tie Clips or any 3/16” dia. wire tie. Holds wire wall reinforcement or pencil rod for seismic zone applications.
Pos-I-Tie® Triangle with #370 #370 welded to #360 L-Type #361 Dovetail
#370 Clip Seismic Clip #316 Triangle Veneer Anchor Seismic Anchor
#75 Pos-I-Tie® System. Dovetail Anchoring System. Channel Slot System is attached
Easy to Install Barrel Screw System (Concrete Only) Incorporates 10 ft to existing concrete walls with
with wire ties. Used for attaching long slots that are cast into concrete. expansion anchors. Anchors are
masonry to an existing wall. Pre- Anchors are inserted in slot which inserted into the slots which allow
drill a 2” deep hole. Ties allow for allows vertical adjustment for vertical adjustment for placement
vertical adjustment. See Page placement in masonry joints. See in masonry joints. See Pages 15
3 for details on the Pos-I-Tie® Page 16 for the Dovetail System for details on the Channel Slot
Anchoring System. and available ties. System.
11 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
103-C
187
186
340
341 342
340-A
341-A 342-A
340-B
341-B 342-B
360 #360 L-Type Seismic Anchor: Made to order. Tab holds wire wall
reinforcement or pencil rod for seismic zone applications. Specify steel
360 type, length, width, bend length, and hole size.
263
263
273
#268 Metal Lath Wall Tie: 2.5 metal lath, sheared to lengths up to 8 ft x width speciied. 269
Install below CMU cores to support mortar or grout ill.
13 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
#668 SCREWS
v
668-EHL146 668-EMF330 668-ELE415 EHH230
Brick Veneer to Steel Brick Veneer to Brick Veneer to Brick Veneer to Wood
Studs Concrete/CMU Concrete/CMU #9-15 x 1-1/2” Tapfast w/
10-16 x 1-1/2” Hex Head Screw #14 x 1-3/4” HWH CreteFlex® 1/4” x 1-3/4” Ultracon® FloSeal washer co-polymer
for Steel Stud applications. Stainless Steel Masonry Screw, co-polymer Coated. coated.
co-polymer coated.
15 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
2”
100 100
1”
7/8”
106 316
100 100-A 100-B
DOVETAIL ANCHORS Length: measured from Face of Conrete. Width: Typically 1” and 2” for Type A Large Dovetail
Anchors.Thickness: 16 gage, 12 gage, 1/8” , and 3/16” thick. See page 28 for Test Data.
#103 Dovetail #106 Dovetail #107 Dovetail #109 Dovetail Flat #110 Dovetail
Triangular Tie: Corrugated Anchor: Horizontal Triangular Anchor: Furring Anchor:
12 gage clip with 3/16” For brick veneer. Tie: 1/8” clip with 3/16” For ield bending into 1-1/2” long for thin
dia. wire tie. For Brick dia. wire tie. stone or CMU. masonry or tile veneers.
and CMU.
#115 Dovetail #117 Dovetail #118 Dovetail Pin #361 Dovetail Seismic #396 Dovetail T-Type
Bent Anchor: Split-Bend Anchor: Anchor: Anchor: Groutless Anchor:
For stone veneer or For stone veneer. For stone veneer. Notched for horizontal For CMU.
CMU. wire attachment.
1007
REGLETS
Concrete Wall
Reglets are the most reliable way to terminate rooing, waterprooing, and
lashing in concrete walls. Use at parapet walls and above shelf angles, lintels
Sloped Stay-Put Reglet and ledges. Standard length is 10 ft. Specify stripout or stay put, size, and
(highlighted Yellow) steeltype. Reglets can be illed with foam or taped to keep wet concrete from
entering.
1000 Series Flashing
Strip-Out Reglets: #230 Standard, #233 Medium, #232 Large. Reglets are
Stay Put Strip-Out
removed after concrete has hardened so that rooing and lashing can be
sealed directly to concrete. Specify 26 gage Mill Galvanized Steel for strip-out
reglets.
17 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
Plasti-Grip® Thermal-Grip®
Ci Prong Ci Prong
Washer with Washer with
Grip-Deck® Grip-Deck®
Ci Screws Ci Screws
Gypsum Board
Continuous Continuous
Vapor Barrier Insulation Insulation
Registered Trademarks on this page by Rodenhouse Inc. Products patented or patent pending
STONE ANCHORS
Steel Types: TMS 402 Building Code allows Mill Galvanized anchors for interior walls and requires Stainless Steel, Epoxy Coated, or Hotdip
Galvanized after Fabrication for exterior walls. Specify accordingly.
STRAP ANCHORS: Typical dimensions are 1” to 2” wide x 16 gage to 3/8” thick x length required.
CORRUGATED ANCHORS: Maximum steel thickness is 3/16”, 1/8” for stainless steel.
HOLES: Specify center spacing from designated end. Holes are typically 1/16” larger than the diameter of the dowel or
fastener used.
TWIST: Twist is 1-3/4” long. Specify the length from the end of the anchor to the start of the twist. Twist is not available
on steel thicker than 1/4” x 1”, 3/16” x 1-1/2” or Stainless Steel thicker than 3/16” x 1” or 1/8” x 1-1/2”.
SPLIT-BENDS: Recommend minimum of 1-1/4” width and minimum 1/2” i.d. split-bend length.
ANCHOR RODS AND ANCHOR BOLTS: Continuous or partially threaded rods are available with UNC (course) threads
from 6-32 to 2” diameter, and in lengths up to 144”.
Stone installation must be designed in accordance with acceptable engineering practices and the
recommendations of the stone fabricator. Stone Anchor Engineering Services are available in certain states
through Heckmann for a fee. Call for details.
19 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
Furnished in Stainless Steel in dowel diameters of 3/8”, 1/2”, 5/8” or 3/4”. To order, specify the 355
length and diameter of dowel, and the overall length. The pins are shaved 1/2” for placement of
the spring on 3/8” and 1/2” diameters. Spring is welded on larger diameters.
Minimum distance between bottom of slab and shelf angle insert is 1-1/2”.
21 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
Beneits WallDefender™
• 90% open weave mesh provides hundreds of pathways for
moisture to exit the cavity.
• Low iber density allows air to move freely through the product
to help promote drying.
• Fast, easy installation.
Weep holes must be used with WallDefender to allow effective
moisture drainage and wall drying
#365 Trash Mortar DiverterTM: #366 Cavity Weep System: #367 Core/Cavity WeepTM System:
V-Shape funnels moisture toward the For Brick Veneer. The Cavity Weep For CMU. The Core/Cavity WeepTM
center of the cavity, away from the back System creates many openings at the System creates openings at the lowest
side of the brick and the face of the back- lowest point of the cavity or core of the point of the core and cavity of the wall,
up wall, then downward through three wall, continuously along the wall. continuously along the wall.
rows of holes to a weep system.
Backplate
BrickVentTM BrickVentTM
Please visit our website for more detailed information.
REINFORCEMENT ITEMS
MASONRY WALL REINFORCEMENT
#1100 Ladder-Type
Masonry Wall Reinforcement:
Manufactured from 9 gage wire, 10’ 8” long with butt-
welded perpendicular cross wires welded 16” on center to
avoid interference with reinforcement in block cores. Wire is
deformed for maximum bonding in mortar joints. 1100
Packaged in 50 pc (500 ft) bundles. Available for 4”, 6”, 8”, 10”
& 12” masonry walls. Special sizes and lengths are available.
ASTM A 82 cold drawn steel wire. Available in Hotdip Galv.
(ASTM A 153 Class B-2), Stainless Steel (ASTM A 580 Type
304), Epoxy Coated and Mill Galvanized (ASTM A 641).
• For attaching Rubble Stone to wood, steel studs, CMU, and concrete backup walls.
• Eliminates Pre-Loading of ties onto 1/4” or 3/8” vertical rods.
• Twist-On Ties are 3/16” diameter Hotdip or Stainless Steel. Specify Length of Tie.
398-J
23 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
REBAR POSITIONERS
Steel-WichTM
“Original Telescoping
Rebar Positioner”TM
(TRP)
ADJUSTABLE
The STEEL-WICHTM (TRP) eliminates need to grout block wall cores in sections, and allows for a monolithic pour of grout
(important in seismic zones). Minimizes rebar waste by an accurate and secure placement method and provides superior
structural strength by precise location of vertical reinforcing steel. The STEEL-WICHTM (TRP) allows for full realization
of the tensile strength of the rebar, thus meeting speciied building code and design requirements (superior splice joint).
Promotes ergonomics, increases jobsite safety, and helps prevent impalement injury. Preserves block integrity, helps
eliminate blowouts, provides containment within vertical core, and prevents grout waste. The STEEL-WICHTM (TRP)
Adjustable Rebar Positioner can be used to retroit rebar in hollow unreinforced CMU walls.
#376 Rebar Positioner #377 Center Cage #379 Centering Clip for
Vertical Rod Positioner Horizontal Rods
9 gage wire positioners for 8” and 12” block. Available in Mill Galvanized and Hotdip Galvanized After Fabrication.
MISCELLANEOUS ITEMS
FLASHING SYSTEMS
Installation Tool
CONSTRUCTION JOINTS
Metal Construction Joints are versatile problem solvers.
Use for expansion joints, waterstops, weakness or control
joints in concrete or masonry. Also, use in formwork to
create reveals and drip edges on formed surfaces of 95
90-L 91
concrete. Furnished in 10 ft lengths.
THREADED INSERTS
Use Threaded Inserts to anchor precast concrete panels to steel frames.
444
#444 Threaded Inserts: Die-cast Zamac 5 zinc alloy offers strength and corrosion 449
resistance. Use with #174 Threaded Eye Bolts or with standard machine bolts.
446
Install in precast and cast-in-place concrete or in grout illed concrete masonry
units. #444 Threaded Insert is also available in plastic. (imported)
25 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
MISCELLANEOUS ITEMS
PLATEGRIP™ EMBED PLATE HOLDER
#615 PlateGrip™ is a fast eficient way to hold an embed Embed
Plate Anchor
plate in place. PlateGrip™ works on all common size CMU.
The stainless steel tie is dry set. It cuts a threaded groove into the
masonry as it is driven into position throught a pre-drilled pilot hole. Visit
our website www.heckmannanchors.com for details.
391
CUSTOM FABRICATION
if you don’t see an anchoring coniguration that works for your situation, let us quote you on your custom
fabrications. Fax or email your design drawings to our expert sales staff.
MISCELLANEOUS ITEMS
CEILING HANGERS
Cast in Place
#460 Nailer Ceiling Insert.
#461 Ceiling Hanger Insert.
Precast Inserts
#486 V-Type
#487 Double V-Type 460
461 486 487 488
#488 T-Type
OTHER ITEMS
#80 Fiberweb® Thru-Wall Flashing #87 Dowel Caps: #45 Band Iron Tightener
Dowel caps create a void in Popular tool used to pull
FIBERWEB® 200: concrete so dowels can slide and band iron around concrete
Manufactured from black laminate of not restrain movement in concrete forms and skids.
polyester ilm, 20 x 10 iberglass scrim Termination Bar
slabs. Available in plastic only.
and a layer of vinyl ilm. Average 8 mils Thru-Wall Flashing
thick. #155 Dowels:
Specify diameter, length, and
FIBERWEB® 300: inish.
1/3 mil metal foil laminated between
layers of polyester ilm bonded to a 20
x 10 iberglass scrim reinforcement.
Fiberweb 300 has a total average mil
thickness of 7 mils.
HOTDIP GALVANIZED AFTER FABRICATION: ASTM A 153. Class B-2: (1.50 oz/ft2.)(0.46kg/m2)*
UNCOATED STEEL:
Sheets: ASTM A 1008/A 1008M
Plates, Bars, and Shapes: ASTM A36/A 36-M96.
Wire: ASTM A 82. ASTM A82M-07
WARRANTY: Heckmann Building Products Inc. warrants its manufactured products to be free from defects in materi-
als or manufacturing. The sole remedy of purchaser under this warranty is that Heckmann will repair or replace any of
its products it inds to be defective. No warranties of itness and no warranties of merchantability for a particular use or
purpose are hereby made. This warranty is expressly in lieu of any other warranties implied or expressed. Heckmann will
not be responsible for any consequential or incidental loss however caused.
Some products may vary slightly from the photographs and drawings shown in the catalog.
27 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
ENGINEERING GUIDE
#75 Pos-I-Tie® Brick Veneer Anchoring System:
Brick Veneer to Steel Studs:
Tension Test: Failure modes: 1 sample screw pulled out of steel stud, 2 samples had the triangle tie pullout from the
mortar joint, 2 samples had the Pos-I-Tie® eye fracture.
Peak Tension Loads: 679 pounds.
Compression Test: Failure modes: All samples failed by buckling of the ties.
Peak Compression Loads: 1,394 pounds.
ENGINEERING GUIDE
#106 Dovetail Corrugated Anchors:
Failure occurred when the anchors pulled out and the bricks separated along the mortar joints.
Peak Loads:
106
12 GAGE ANCHORS 16 GAGE ANCHORS
1,479 lbs. 1,194 lbs.
#130 Weld-On Channel Slot and #129 Channel Slot Triangle Tie:
Failures occurred with the clip separating from the triangle tie. 130
Peak Loads:
TENSION COMPRESSION 2” CAVITY COMPRESSION 4” CAVITY
129
935 lbs. 515 lbs. 578 lbs.
#130 Weld-On Channel Slot - pullout of Channel slot anchor from channel slot: 130
16 gage Channel Slot anchors were pulled from the slots.
Peak Loads:
11 GAGE SLOTS 16 GAGE SLOTS
134
950 lbs. 668 lbs.
29 WWW.HECKMANNANCHORS.COM INFO@HECKMANNANCHORS.COM
2015 Edition Heckmann Building Products, Inc. Our 92nd Year!
ENGINEERING GUIDE
#189 L-Type Column Anchors - Tested in pairs with steel column and CMU wall:
Peak Loads:
189
TENSION COMPRESSION 1” CAVITY COMPRESSION 4” CAVITY SHEAR
3,242 lbs. 9,863 lbs. 6,373 lbs. 1,584 lbs.
SHEAR TEST:
The tests were made at the mid point of the slot of the insert. The load was applied 2” out from the surface of the
concrete.
INSERT MAX. LOAD. lbs. FAILURE
3/4” 11,100 lbs. Maximum Load. Threads stripped on bolt.
3/4” ong 19,150 lbs. Maximum Load. Bold had slipped to bottom of slot and head sheared.
Column Anchors
Continuous
Weld-On Anchor Rod
Stone Anchors
Spring Loaded Dowel
Dovetail Sytem
S T U D
TEEL T E
L
S E
EE
NC R
ST
CO
AL
UR
CT
Drip Edge Flashing
RU
Mortar Delection System
ST
Thru wall Flashing Channel Slot Stone Anchor
U/
CM
Channel Slot System
Termination Bar
Stainless Steel Flashing
Triangle Tie
Corrugated Brick Anchor