450 - 750 VOLTS - Copper conductor PVC insulated IEC 60227
HO 7V - U With Solid Conductor - TYPE 60227 IEC 01

For internal wiring of equipment rated voltage up to 1000 V AC and up to 750 V DC to earth.

Conductor
Weight of Maximum Standard
Nominal
Catalogue Diameter Insulation Overall Finished DC Packing
Cross Number of of
Number Thickness Diameter Cable Resistance Length
Section Wires in Conductor 0
Approx. at 20 C
Conductor Approx.
mm2 mm mm mm Kg / Km Ohm / Km M + 5%
0C 010004xx 1 x 1.5 1 1.38 0.7 3.2 21 12.1 100 C
0C 010005xx 1 x 2.5 1 1.78 0.8 3.9 34 7.41 100 C
0C 010006xx 1x4 1 2.25 0.8 4.4 50 4.61 100 C
0C 010007xx 1x6 1 2.76 0.8 5.0 70 3.08 100 C
0C 010008xx 1 x 10 1 3.57 1.0 6.4 115 1.83 100 C

Color: green / yellow, blue, black, green, red, yellow, brown, grey, orange, white,
Code: 01 02 03 04 05 06 07 08 09 10

For required colour replace the last two digits - xx, by color code.

RIYADH CABLES WIRES & WIRING CABLES PAGE 1


450 - 750 VOLTS - Copper conductor PVC insulated IEC 60227
HO 7V - R With Stranded Conductor - TYPE 60227 IEC 01

For internal wiring of equipment rated voltage up to 1000 V AC and up to 750 V DC to earth.

Conductor
Weight of Maximum Standard
Nominal
Catalogue Diameter Insulation Overall Finished DC Packing
Cross Number of of
Number Thickness Diameter Cable Resistance Length
Section Wires in Conductor 0
Approx. at 20 C
Conductor Approx.
mm2 mm mm mm Kg / Km Ohm / Km M + 5%
0C 010104xx 1 x 1.5 7 1.50 0.7 3.3 22 12.1 100 C
0C 010105xx 1 x 2.5 7 2.01 0.8 4.0 35 7.41 100 C
0C 010106xx 1x4 7 2.55 0.8 4.6 52 4.61 100 C
0C 010107xx 1x6 7 3.12 0.8 5.2 71 3.08 100 C
0C 010108xx 1 x 10 7 4.05 1.0 6.7 116 1.83 100 C
0C 010109xx 1 x 16 7 5.10 1.0 7.8 185 1.15 100 C
0C 0101 10xx 1 x 25 7 6.42 1.2 9.7 290 0.727 100 C
0C 0101 11xx 1 x 35 7 7.65 1.2 10.9 390 0.524 100 C
000101xx12 1 x 50 19 8.90 1.4 12.8 525 0.387 3000 D
000101xx13 1 x 70 19 10.70 1.4 14.6 735 0.268 3000 D
000101xx14 1 x 95 19 12.60 1.6 17.1 1010 0.193 3000 D
000101xx15 1 x 120 37 14.21 1.6 18.8 1260 0.153 2000 D
000101xx16 1 x 150 37 15.75 1.8 20.9 1540 0.124 2000 D
000101xx17 1 x 185 37 17.64 2.0 23.3 1940 0.0991 2000 D
000101xx18 1 x 240 61 20.25 2.2 26.6 2550 0.0754 1000 D
000101xx19 1 x 300 61 22.68 2.4 29.6 3180 0.0601 1000 D
000101xx20 1 x 400 61 25.65 2.6 33.2 4050 0.0470 500 D
000101xx21 1 x 500 61 28.80 2.8 37.0 5050 0.0366 500 D
000101xx22 1 x 630 127/91 32.76 2.8 41.0 6050 0.0283 500 D

Color: green / yellow, blue, black, green, red, yellow, brown, grey, orange, white,
Code: 01 02 03 04 05 06 07 08 09 10

For required colour replace the last two digits - xx, by color code.

RIYADH CABLES WIRES & WIRING CABLES PAGE 2


450 - 750 VOLTS - Copper conductor PVC insulated IEC 60227
HO 7V - K With Flexible Conductor - TYPE 60227 IEC 02

For internal wiring of equipment rated voltage up to 1000 V AC and up to 750 V DC to earth.

Conductor
Weight of Max. DC Standard
Nominal
Catalogue Approx Diameter Insulation Overall Finished Resistance Packing
Cross of 0
Number No & Nom. Thickness Diameter Cable at 20 C Length
Section Conductor
strand Approx.
Diameter . Approx.
mm2 No x mm mm mm mm Kg / Km Ohm / Km M + 5%
0C 010504xx 1 x 1.5 28 x 0.25 1.7 0.7 3.4 23 13.3 100 C
0C 010505xx 1 x 2.5 46 x 0.25 2.2 0.8 4.1 35 7.98 100 C
0C 010506xx 1x4 51 x 0.30 3.1 0.8 4.8 51 4.95 100 C
0C 010507xx 1x6 77 x 0.30 3.8 0.8 5.3 71 3.30 100 C
0C 010508xx 1 x 10 74 x 0.40 5.0 1.0 6.8 125 1.91 100 C
0C 010509xx 1 x 16 118 x 0.40 6.3 1.0 8.1 195 1.21 100 C
0C 010510xx 1 x 25 183 x 0.40 6.4 1.2 9.2 300 0.780 100 C
0C 01051 1xx 1 x 35 257 x 0.40 9.2 1.2 10.5 410 0.554 100 C
000105xx12 1 x 50 371 x 0.40 11.0 1.4 13.9 585 0.386 1000 D
000105xx13 1 x 70 337 x 0.50 13.0 1.4 16.0 810 0.272 1000 D
000105xx14 1 x 95 444 x 0.50 15.2 1.6 18.2 1065 0.206 1000 D
000105xx15 1 x 120 570 x 0.50 17.0 1.6 20.2 1335 0.161 1000 D
000105xx16 1 x 150 712 x 0.50 19.0 1.8 22.5 1600 0.129 1000 D
000105xx17 1 x 185 864 x 0.50 21.0 2.0 24.9 2000 0.106 1000 D
000105xx18 1 x 240 1140x0.50 24.0 2.2 28.4 2500 0.0801 1000 D

Color: green / yellow, blue, black, green, red, yellow, brown, grey, orange, white,
Code: 01 02 03 04 05 06 07 08 09 10

For required colour replace the last two digits - xx, by color code.

RIYADH CABLES WIRES & WIRING CABLES PAGE 3


300 - 500 VOLTS - Copper conductor PVC insulated and Sheathed
IEC 60227(IEC 10)

Nominal Number of Diameter Weight of Max. Standard


Catalogue Cross Wires in of Insulation Sheath Overall Finished DC Packing
Number Section C onduc tor Conductor Thickness Thickness Diameter Cable R es is tanc e Length
0
Approx. Approx. at 20 C

mm2 mm mm mm mm Kg/Km Ohm/Km M + 5%


0B 01002408 2 x 1.5 1 1.38 0.7 1.2 10.0 120 12.1 100 C
0B 01002508 2 x 2.5 1 1.78 0.8 1.2 11.5 165 7.41 100 C
0B 01002608 2x4 1 2.25 0.8 1.2 12.5 215 4.61 100 C
0B 01002708 2x6 1 2.76 0.8 1.2 13.5 270 3.08 100 C
0B 01002808 2 x 10 1 3.57 1.0 1.4 16.5 440 1.83 1000/2000

0B 01003408 3 x 1.5 1 1.38 0.7 1.2 10.5 140 12.1 100 C


0B 01003508 3 x 2.5 1 1.78 0.8 1.2 12.0 195 7.41 100 C
0B 01003608 3x4 1 2.25 0.8 1.2 13.0 250 4.61 100 C
0B 01003708 3x6 1 2.76 0.8 1.4 14.5 345 3.08 100 C
0B 01003808 3 x 10 1 3.57 1.0 1.4 17.5 540 1.83 1000/2000

0B 01004408 4 x 1.5 1 1.38 0.7 1.2 11.5 165 12.1 100 C


0B 01004508 4 x 2.5 1 1.78 0.8 1.2 13.0 235 7.41 100 C
0B 01004608 4x4 1 2.25 0.8 1.4 14.5 325 4.61 100 C
0B 01004708 4x6 1 2.76 0.8 1.4 16.0 430 3.08 1000/2000
0B 01004808 4 x 10 1 3.57 1.0 1.4 19.0 665 1.83 1000/2000

0B 01005408 5 x 1.5 1 1.38 0.7 1.2 12.0 195 12.1 100 C


0B 01005508 5 x 2.5 1 1.78 0.8 1.2 14.0 285 7.41 100 C
0B 01005608 5x4 1 2.25 0.8 1.4 16.0 405 4.61 100 C
0B 01005708 5x6 1 2.78 0.8 1.4 17.5 530 3.08 1000/2000
0B 01005808 5 x 10 1 3.57 1.0 1.4 21.0 810 1.83 1000/2000

Color code:
2 cores : Red, Black 2 cores : light Blue, Brown
3 cores : Red, Yellow and Blue 3 cores : light Blue, Black, Brown
4 cores : Red, Yellow, Blue and Black 4 cores : light Blue, Black, Brown, Black
5 cores : Red, Yellow, Blue, Black and Green 5 cores : light Blue, Black, Brown, Brown, Black

For Green / Yellow Core - Replace 5th digits by 3.

For green / yellow Core - add letter “J” at the end of item code.

outer s heath G ray.

RIYADH CABLES WIRES & WIRING CABLES PAGE 4


300 - 500 VOLTS - Copper conductor PVC insulated and Sheathed
IEC 60227 (IEC 10)

Nominal Number of Diameter Weight of Max. Standard


Catalogue Cross Wir es i n of Insulation Sheath Overall Finished DC Packing
Number Section C onduc tor Conductor Thickness Thickness Diameter Cable R es is tanc e Length
0
Approx. Approx. at 20 C
mm2 mm mm mm mm Kg/Km Ohm/Km M + 5%
0B 01012408 2 x 1.5 7 1.50 0.7 1.2 10.5 125 12.1 100 C
0B 01012508 2 x 2.5 7 2.01 0.8 1.2 12.0 170 7.41 100 C
0B 01012608 2x4 7 2.55 0.8 1.2 13.0 220 4.61 100 C
0B 01012708 2x6 7 3.12 0.8 1.2 14.0 280 3.08 100 C
0B 01012808 2 x 10 7 4.05 1.0 1.4 17.5 470 1.83 1000/2000
0B 01012908 2 x 16 7 5.10 1.0 1.4 20.0 650 1.15 1000/2000
0B 01012108 2 x 25 7 6.42 1.2 1.4 24.0 980 0.727 1000
0B 010121 18 2 x 35 7 7.65 1.2 1.6 27.5 1300 0.524 1000

0B 01013408 3 x 1.5 7 1.50 0.7 1.2 11.0 145 12.1 100 C


0B 01013508 3 x 2.5 7 2.01 0.8 1.2 12.5 200 7.41 100 C
0B 01013608 3x4 7 2.55 0.8 1.2 13.5 270 4.61 100 C
0B 01013708 3x6 7 3.12 0.8 1.4 15.5 360 3.08 100 C
0B 01013808 3 x 10 7 4.05 1.0 1.4 19.0 570 1.83 1000/2000
0B 01013908 3 x 16 7 5.10 1.0 1.4 21.5 830 1.15 1000/2000
0B 01013108 3 x 25 7 6.42 1.2 1.6 26.0 1255 0.727 1000
0B 010131 18 3 x 35 7 7.65 1.2 1.6 29.0 1640 0.524 1000

0B 01014408 4 x 1.5 7 1.50 0.7 1.2 12.0 165 12.1 100 C


0B 01014508 4 x 2.5 7 2.01 0.8 1.2 13.5 240 7.41 100 C
0B 01014608 4x4 7 2.55 0.8 1.4 15.0 330 4.61 100 C
0B 01014708 4x6 7 3.12 0.8 1.4 17.0 460 3.08 1000/2000
0B 01014808 4 x 10 7 4.05 1.0 1.4 20.5 700 1.83 1000/2000
0B 01014908 4 x 16 7 5.10 1.0 1.4 23.5 1025 1.15 1000/2000
0B 01014108 4 x 25 7 6.42 1.2 1.6 28.5 1590 0.727 1000
0B 010141 18 4 x 35 7 7.65 1.2 1.6 32.0 2040 0.524 1000

0B 01015408 5 x 1.5 7 1.50 0.7 1.2 12.0 200 12.1 100 C


0B 01015508 5 x 2.5 7 2.01 0.8 1.2 14.5 290 7.41 100 C
0B 01015608 5x4 7 2.55 0.8 1.4 17.0 410 4.61 100 C
0B 01015708 5x6 7 3.12 0.8 1.4 18.5 550 3.08 1000/2000
0B 01015808 5 x 10 7 4.05 1.0 1.4 22.0 850 1.83 1000/2000
0B 01015908 5 x 16 7 5.10 1.0 1.6 26.0 1250 1.15 1000/2000
0B 01015108 5 x 25 7 6.42 1.2 1.6 31.5 1860 0.727 1000
0B 010151 18 5 x 35 7 7.65 1.2 1.6 35.0 2540 0.524 1000

Color code:
2 cores : Red, Black 2 cores : light Blue, Brown
3 cores : Red, Yellow and Blue 3 cores : light Blue, Black, Brown
4 cores : Red, Yellow, Blue and Black 4 cores : light Blue, Black, Brown, Black
5 cores : Red, Yellow, Blue, Black and Green 5 cores : light Blue, Black, Brown, Brown, Black

For Green / Yellow Core - Replace 5th digits by 3.

For green / yellow Core - add letter “J” at the end of item code.

outer s heath G ray.

RIYADH CABLES WIRES & WIRING CABLES PAGE 5


300 - 500 VOLTS - Flexible Copper conductor PVC insulated and Sheathed
HO5VV-F, IEC 60227 (IEC 53)

Nominal Number & Diameter Thickness Weight of


Weight of Max D C
Catalogue Cross dia of of of Sheath Overall Finished Packing
Insulation R es is tanc e
Number Section wires in Conductor Diameter Cable 0
Thickness at 20 C
Approx. Conductor Approx. Approx. Approx.
mm2 no x mm mm mm mm mm Kg/Km Ohm/Km M + 5%
0B 01252210 2 x 0.75 22 x 0.20 1.1 0.6 0.8 7.2 56 26.0 100
0B 01252310 2x1 29 x 0.20 1.3 0.6 0.8 7.5 65 19.5 100
0B 01252410 2 x 1.5 28 x 0.25 1.6 0.7 0.8 8.6 80 13.3 100
0B 01252510 2 x 2.5 46 x 0.25 2.1 0.8 1.0 10.6 130 7.98 100

0B 01253210 3 x 0.75 22 x 0.20 1.1 0.6 0.8 7.6 65 26.0 100


0B 01253310 3x1 29 x 0.20 1.3 0.6 0.8 8.0 80 19.5 100
0B 01253410 3 x 1.5 28 x 0.25 1.6 0.7 0.9 9.4 100 13.3 100
0B 01253510 3 x 2.5 46 x 0.25 2.1 0.8 1.1 11.4 155 7.98 100

0B 01254210 4 x 0.75 22 x 0.20 1.1 0.6 0.8 8.3 80 26.0 100


0B 01254310 4x1 29 x 0.20 1.3 0.6 0.9 9.0 95 19.5 100
0B 01254410 4 x 1.5 28 x 0.25 1.6 0.7 1.0 10.5 130 13.3 100
0B 01254510 4 x 2.5 46 x 0.25 2.1 0.8 1.1 12.5 200 7.98 100

0B 01255210 5 x 0.75 22 x 0.20 1.1 0.6 0.9 9.3 105 26.0 100
0B 01255310 5x1 29 x 0.20 1.3 0.6 0.9 9.8 125 19.5 100
0B 01255410 5 x 1.5 28 x 0.25 1.6 0.7 1.1 11.6 160 13.3 100
0B 01255510 5 x 2.5 46 x 0.25 2.1 0.8 1.2 13.9 245 7.98 100

Color code:
2 cores : light blue, brown
3 cores : light blue, black, brown 3 cores : light blue, brown, green / yellow
4 cores : light blue, black, brown, black 4 cores : light blue, black, brown and green / yellow
5 cores : light blue, black, brown, brown, Black 5 cores : light blue, black, brown, black and green / yellow

For Green / Yellow Core - add letter “J” at the end of item Code.

outer s heath W hite.

RIYADH CABLES WIRES & WIRING CABLES PAGE 6


PVC insulated, Non-sheathed Flexible Cords for Internal Wiring. Single Core and Twisted Twin
COPPER CONDUCTOR - STANDARD(S) : IEC 60227 (IEC 06)
300 / 500 VOLTS HO5V-K

Conductor
Mean
Radial Overall Maximum
Thickness DC Approximate
Nom.cross Nominal diameter weight
of (upper limit) Resistance
sectional diameter of insulation
0
at 20 C
area wire single
Single Twin
2
mm mm mm mm / Km Kg / Km Kg / Km
0.5 0.20 0.6 2.4 39.0 9 19
0.75 0.20 0.6 2.6 26.0 12 24
1.0 0.20 0.6 2.8 19.5 15 29

Note :
The cord may be available in twin twisted form.
For solid wire conductor equivalent cables, please refer to BS 6004 or IEC 60227.
For larger sizes of flexible conductor cables, please refer to BS 6004 or IEC 60227.

C ons truc tion :


Annealed Copper conductor as per IEC 60228, CLASS 5.
PVC Insulation.

C ore Identific ation :


Green / Yellow, Blue or any other colour.

RIYADH CABLES WIRES & WIRING CABLES PAGE 7


PVC insulated, Non-sheathed Flexible Cords for Internal Wiring - Parallel Twin
COPPER CONDUCTOR - STANDARD (S) : IEC 60227 (IEC 42)
300 / 300 VOLTS

Conductor Mean overall dimensions


Radial Maximum
Thickness DC Approx.
Nom. Cross Maximum of Resistance Weight
Lower Upper
Sectional diameter of insulation
0
at 20 C
Limit Limit
area Wire

mm2 mm mm mm mm / Km Kg / Km
2 x 0.50 0.16 0.8 2.5 x 5.0 3.0 x 6.0 39.0 22
2 x 0.75 0.16 0.8 2.7 x 5.4 3.2 x 6.4 26.0 28

C ons truc tion :


Annealed Copper conductor as per IEC 60228 Class 6.

The conductors shall be laid parallel and covered with PVC Insulation

The insulation shall be provided with a groove on each side between the conductors to
facilitate seperation of the cores.

RIYADH CABLES WIRES & WIRING CABLES PAGE 8


PVC insulated, PVC Sheathed Cables, Single core, Flat Twin and Three cores
COPPER CONDUCTOR - STANDARD(S) : BS 6004 - 300 / 500 VOLTS

No. & Mean overall dia. or Max.


Radial dimensions.
Cross No. of Radial DC Approx.
Thickness
sectional wires in Thickness Resist Weight
of Lower Upper
area of conductor of sheath ance
insulation Limit Limit 0
conductor at 20 C

mm2 mm mm mm mm mm / Km Kg / Km
1 x 1.0 1 0.6 0.8 3.8 4.5 18.1 28
1 x 1.5 1 0.7 0.8 4.2 4.9 12.1 36
1 x 2.5 1 0.8 0.8 4.8 5.8 7.41 51
1x4 7 0.8 0.9 5.4 6.8 4.61 74
1x6 7 0.8 0.9 6.0 7.4 3.08 96
1 x 10 7 1.0 0.9 7.2 8.8 1.83 150
1 x 16 7 1.0 1.0 8.4 10.5 1.15 220
1 x 25 7 1.2 1.1 10.0 12.5 0.727 335
1 x 35 7 1.2 1.1 11.0 13.5 0.524 440

2 x 1.0 1 0.6 0.9 4.0 x 6.2 4.7 x 7.4 18.1 53


2 x 1.5 1 0.7 0.9 4.4 x 7.0 5.4 x 8.4 12.1 71
2 x 2.5 1 0.8 1.0 5.2 x 8.4 6.2 x 9.8 7.41 106
2x4 7 0.8 1.0 5.6 x 9.6 7.2 x 11.5 4.61 150
2x6 7 0.8 1.1 6.4 x 10.5 8.0 x 13.0 3.08 200
2 x 10 7 1.0 1.2 7.8 x 13.0 9.6 x 16.0 1.83 320
2 x 16 7 1.0 1.3 9.0 x 15.5 11.0 x 18.5 1.15 460

3 x 1.0 1 0.6 0.9 4.0 x 8.4 4.7 x 9.8 18.1 76


3 x 1.5 1 0.7 0.9 4.4 x 9.8 5.4 x 11.5 12.1 106
3 x 2.5 1 0.8 1.0 5.2 x 11.5 6.2 x 13.5 7.41 160
3x4 7 0.8 1.1 5.8 x 13.5 7.4 x 16.5 4.61 230
3x6 7 0.8 1.1 6.4 x 15.0 8.0 x 18.0 3.08 300
3 x 10 7 1.0 1.2 7.8 x 19.0 9.6 x 22.5 1.83 475
3 x 16 7 1.0 1.3 9.0 x 22.0 11.0 x 26.5 1.15 690

C ons truc tion :


Plain annealed copper conductor Class 1 & 2 as per IEC 60228.
PVC Insulation.
PVC Sheath.
The sheath shall be closely fitting but shall not adhere to the cores and in the case of twin and three-core,
the cores shall be laid parallel.

C ore Identific ation :


Single : Brown or Blue, Single : Red or Black
Twin : Brown, Blue Twin : Red, Black
Three-core : Brown, Black (Centre core), Gray Three-core : Red, Yellow (centre core), Blue

C olour of s heath
Single : Gray, (other colour on request)
Flat Twin and three core : Gray

RIYADH CABLES WIRES & WIRING CABLES PAGE 9


PVC insulated, PVC Sheathed Cables with Earth Continuity Conductor, Flat Twin and Three cores
COPPER CONDUCTOR - STANDARD : BS 6004 300 / 500 VOLTS

Mean overall dia. or Max.


No. & Earth
No. of Radial dimensions. conti- DC
Cross Radial Approx.
wires in Thickness nuity Resist
sectional Thickness Weight
cond- of cond. ance
area of of sheath Lower Upper cross at
uctor insulation
conductor Limit Limit section 0
20 C

mm2 mm mm mm mm mm mm2 / Km Kg / Km
2 x 1.0 1 0.6 0.9 4.0 x 7.2 4.7 x 8.6 1.0 18.1 68
2 x 1.5 1 0.7 0.9 4.4 x 8.2 5.4 x 9.6 1.0 12.1 87
2 x 2.5 1 0.8 1.0 5.2 x 9.8 6.2 x 11.5 1.5 7.41 135
2x4 7 0.8 1.0 5.6 x 10.5 7.2 x 13.0 1.5 4.61 170
2x6 7 0.8 1.1 6.4 x 12.5 8.0 x 15.0 2.5 3.08 240
2 x 10 7 1.0 1.2 7.8 x 15.5 9.6 x 19.0 4 1.83 380
2 x 16 7 1.0 1.3 9.0 x 18.0 11.0 x 22.5 6 1.15 550

3 x 1.0 1 0.6 0.9 4.0 x 9.6 4.7 x 11.0 1.0 18.1 90


3 x 1.5 1 0.7 1.1 4.4 x 10.5 5.4 x 12.5 1.0 12.1 120
3 x 2.5 1 0.8 0.9 5.2 x 12.5 6.2 x 14.5 1.0 7.41 180
3x4 7 0.8 1.0 5.8 x 14.5 7.4 x 18.0 1.5 4.61 250
3x6 7 0.8 1.1 6.4 x 16.5 8.0 x 20.0 2.5 3.08 330
3 x 10 7 1.0 1.2 7.8 x 21.0 9.6 x 25.5 4 1.83 540
3 x 16 7 1.0 1.3 9.0 x 24.5 11.0 x 29.5 6 1.15 770

C ons truc tion :


Plain annealed copper conductor Class 1 & 2 as per IEC 60228.
PVC Insulation.
PVC Sheath.
The sheath shall be closely fitting but shall not adhere to the cores, which shall be laid parallel
with uninsulated earth continuity conductor.

C olour for C ore Identific ation


Twin : Brown, Blue Twin : Red, Black.
Three-core : Brown, Black (Centre core), Gray Three-core : Red, Yellow (centre core), Blue.

P os ition of c ontinuity c onduc tor


Twin : Centrally placed between cores in same plane.
Three cores : Centrally placed between black and gray cores in same plane (OR) placed between yellow and blue.

C olour of outer s heath


Gray.

RIYADH CABLES WIRES & WIRING CABLES PAGE 10


TION
NYLON JACKET
OVER INSULA

PVC INSULATION

SOFT ANNEALED
STRANDED COPPER

Construction :
C onduc tor - Soft drawn annealed copper conductors as per UL 83. Available in solid or stranded
Type for sizes 14, 12 and 10 AWG. Sizes 8 AWG and larger available in stranded only.
Insulation - Extruded Polyvinyl Chloride (PVC) compound rated 75 and 90 deg. C.
J ac ket - Tough, smooth, heat and light stablized, low moisture absorption nylon conforming
to UL requirements for type THHN or THWN. This jacket offers a great degree of protection
to the PVC insulation from abrasion and cut through which may be encountered in pulling wire
Through conduits. Nylon has long been recognized as one of the toughest jacketing material
used in wire and cable manufacturing.

FEA TURES :
1.Meets UL ‘VW - 1’ Flame Test requirements.
2.Wet or dry locations - Rated 90 deg. C dry, 75 deg. C wet.
3.Resistant to gas and oil exposure - Rated gasoline and oil resistant II per UL.
4.Versatile - Can be used as follows:
a) THHN - 90 deg. C dry building wire
b) THWN - 75 deg. C wet and dry building wire
c) MTW - 90 deg. C machine tool wire
5.Pulls easier - tough, smooth nylon jacket over PVC insulation.
6.Small diameter - more conductors per conduit.

APPLICA TIONS :

Type THHN - THWN building wires are intended for general purpose applications and may be installed in
conduit, duct or other recognized raceways in wet or dry locations. Type THHN - THWN wires are designed to
operate at conductor temperatures of 75 deg. C for 600 volts service in wet and dry locations. Applicable for
both new work and rewiring installations where the smaller wire diameter permits additional circuits or larger
conductors to be installed in the conduit without exceeding maximum fill limitations.
Type THHN - THWN wires are also recommended for industrial installation where exceptional resistance to
heat and corrosive atmospheres are needed, such as chemical paints, oil refineries, paper mills, etc.

RIYADH CABLES WIRES & WIRING CABLES PAGE 11


NYLON JACKET
OVER INSULATION

PVC INSULATION

SOFT ANNEALED
STRANDED COPPER

MARKING EXAMPLE:
RIYADH CABLES GROUP, K.S.A Year of manufacturing, 600 V, Type (THHN or THWN or
TFFN) GASOLINE AND OIL RESISTANT IIVW-1 Size

Stradards :
UL 83-Underwriters Laboratories, Thermoplastic Insulated wires and Cables.
UL 1063-Underwriters Laboratories, Machine Tool Wires and Cables.
UL 1581-Underwriters Laboratories, Reference standard for Electrical wires, Cables and
Flexible Cords. 600 Volts
Copper Conductor PVC Insulated NYLON Jacketed THHN/THWN Wires UL 83, 1581

CONDUCT OR Nylon Approx. S tandard


Approx.
Insulation Jacket Weight of DC packing
Equiv . Overall
AWG Stranding Diameter Thickness Thickness Cond. R es is tanc e length
mm2 Diameter
No x mm mm mm mm Kg/Km at 2 0 0C M
mm
(Nom.) (Nom.) (A ve.) (Min.) Ohm/K m (+ 5%)
18* 0.82 16 x 0.254 1.19 0.38 0.10 2.3 12 18.23 152 C
16* 1.31 19 x 0.296 1.48 0.38 0.10 2.5 17 13.42 152 C
14 2.08 19 x 0.373 1.86 0.38 0.10 2.9 25 8.62 152 C
12 3.31 19 x 0.47 2.35 0.38 0.10 3.4 37 5.43 152 C
10 5.26 19 x 0.594 2.97 0.51 0.10 4.3 59 3.409 152 C
8 8.37 19 x 0.749 3.75 0.76 0.13 5.6 96 2.144 152 C

6 13.30 19 x 0.945 4.72 0.76 0.13 6.6 146 1.348 152 C


4 21.15 19 x 1.19 5.95 1.02 0.15 8.4 233 0.8481 1000
2 33.63 19 x 1.50 7.50 1.02 0.15 9.9 356 0.5335 1000
1/0 53.48 37 x 1.36 9.52 1.27 0.18 12.5 567 0.3354 1000
2/0 67.43 37 x 1.52 10.64 1.27 0.18 13.6 697 0.266 1000

* Listed as TFFN
Colour:Black, White, Red, Blue, Green, Yellow, Orange, Brown, etc.
Cutting Length:152 M (500 FT) in Coils 1000 M (3280 FT) in Drums

RIYADH CABLES WIRES & WIRING CABLES PAGE 12


NYLON JACKET
OVER INSULATION

PVC INSULATION

SOFT ANNEALED
STRANDED COPPER

TABLE 1
Current carrying capacities of THWN and THHN insulated Copper Conductors rated 600 V not more than
three conductors in raceway or cable or earth (Direct Buried) based on ambient temp. of 30 deg. C
Size THWN THHN
AWG AMPS AMPS
18 14
16 18
14 20 25
12 25 30
10 35 40
8 50 55
6 65 75
4 85 95
2 115 130
1/0 150 170
2/0 175 195

TABLE 2
Current carrying capacities of THWN and THHN single insulated Copper Conductors rated 600 V in free air
based on ambient air temp. of 30 deg. C

Size THWN THHN


AWG AMPS AMPS
18 18
16 24
14 30 35
12 35 40
10 50 55
8 70 80
6 95 105
4 125 140
2 170 190
1/0 230 260
2/0 265 300

TABLE 3 - CORRECTIO N F ACT ORS


Ambient T emp 0C 0
THWN (75 C) 0
THHN (90 C)
21 - 25 1.05 1.04
26 - 30 1.00 1.00
31 - 35 0.94 0.96
36 - 40 0.88 0.91
41 - 45 0.82 0.87
46 - 50 0.75 0.82
51 - 55 0.67 0.76
56 - 60 0.58 0.71
61 - 70 0.33 0.58
71 - 80 - 0.41
For ambient temp. other than 30 deg. C. multiply the ampacities given in tablets 1 & 2 by the appropriate
factor given in Table 3.

RIYADH CABLES WIRES & WIRING CABLES PAGE 13


NYLON JACKET
OVER INSULATION

PVC INSULATION

SOFT ANNEALED
STRANDED COPPER

THHN/THWN BUILDING WIRE 90 DEG. C 600 VOLTS


Table 4 : Conduit Fill
Maximum number of THHN/THWN Conductors in conduit or tubing as per 1990 NEC

Conduit trade size (inches)


Size
AWG
1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6
18* 19 34 55 97 132 216 - - - - - -
16* 15 26 43 76 104 169 - - - - - -
14 13 24 39 69 94 154 - - - - - -
12 10 18 29 51 70 114 164 - - - - -
10 6 11 18 32 44 73 104 160 - - - -
8 3 5 9 16 22 36 51 79 106 136 - -
6 1 4 6 11 15 26 37 57 76 98 154 -
4 1 2 4 7 9 16 22 35 47 60 94 137
3 1 1 3 6 8 13 19 29 39 51 80 116
2 1 1 3 5 7 11 16 25 33 43 67 97
1 - 1 1 3 5 8 12 18 25 32 50 72
1/0 - 1 1 3 4 7 10 15 21 27 42 61
2/0 - 1 1 2 3 6 8 13 17 22 35 51

* Listed as TFFN

Table 5 : Combination of Conductors


For groups or combinations of conductors, the conduit or tubing shall be of such size that the sum of the cross
sectional areas of the individual conductors will not be more than percentage of the internal cross sectional
area of the conduit or tubing as shown below :

No. of conductors 1 2 3 4 over 4


Percentage 53 31 40 40 40

RIYADH CABLES WIRES & WIRING CABLES PAGE 14


RIYADH CABLES WIRES & WIRING CABLES 15
NOT IC E
RCG C C ata loq ues un der ci rcu lat ion ar e s till v ali d. Som e i nte rna tio nal an d N ati ona l
s ta n da r ds m e n tio n e d in R C G C c a ta lo qu e s m ig h t g e t a m e n de d by r e s pe c tiv e
o r g a n i z a ti o n s w i th o u t p r i o r n o ti c e . F o r R i y a d h C a b l e s P r o d u c ts , th e l a te s t
A mendments of applic able s tandards under c irc ulation are applic able. F or Wi res
and W iring c ables manufac tured by R C G C , c olour c ode mentioned in res pec tive
s tandards are applic able. However, R C G C c an als o provide the following c olour
code as required by some utilities.

1 Core: Red or Black


2 Core: Red, Black
3 Core: Red, Yellow , Blue
4 Core: Red, Yellow , Blue, Black
5 Core: Red, Yellow , Blue, Black, Green
More than 5 cores: Black cores with white printed numerals.

In the interest of product improvement, Riyadh Cables reserves the right to alter
the given data in this Catalogue without any prior notice.