User Manual: CS 5000 Model 11674xx
User Manual: CS 5000 Model 11674xx
User Manual: CS 5000 Model 11674xx
CS 5000
Model 11674xx
USA
Garrett Metal Detectors
Security Division
1881 W. State Street
Garland, Texas 75042-6797 USA
Phone: 1.800.234.6151
Fax: 1.972.494.1881
Email: security@garrett.com
Website: garrett.com
International
Garrett Metal Detectors
International Security Division
1881 W. State Street
Garland, Texas 75042-6797 USA
Phone: 1.972.494.6151
Fax: 1.972.494.1881
Email: international@garrett.com
Website: garrett.com
CS 5000
User Manual
MANUFACTURER CAUTION
Read Thoroughly Before Operating
CAUTION! Use of this equipment in a manner not specified by the manufacturer may result in damage to
property or injury to persons.
CAUTION! CS 5000 must be firmly anchored to the floor to reduce the risk of injury to persons or property
damage due to accidental knock down.
Warning! Battery Safety: The optional Battery Backup Module and the CMA Interface module contain
rechargeable batteries that may contain small amounts of harmful substances.
• Caution: Do not put the batteries in trash that is disposed of in landfills. When disposing of the
battery, comply with local ordinances or regulations and your company’s safety standards.
• Recycling centers and retailers with recycling programs may be found at www.rbrc.org.
SYMBOLS:
Garrett Metal Detectors and garrett.com are trademarks and registered trademarks of Garrett Electronics, Inc.
If further assistance is required, please contact the factory using the contact information on the front cover.
MEDICAL SAFETY
Garrett Metal Detectors makes every effort to ensure its products are safe for use. Extensive research by Garrett
has produced no information which would indicate that its products have any adverse effects on medical
implants, pregnancy, recording media or magnetic strips. Garrett makes every effort to cooperate with medical
device manufacturers and to communicate with agencies such as the United States Food and Drug
Administration and Health Canada as a means of assuring product safety. The electromagnetic fields produced
by Garrett products are similar to those encountered in the daily environment and meet U.S. and International
standards for electromagnetic emissions.
Garrett recognizes that certain medical devices may have additional requirements which may require special
care. Any recommendations or directives issued by personal physicians or medical device manufacturers
should be followed. If, for any reason, (e.g. doctors orders, etc.), a patron objects to being scanned with a metal
detector, it is recommended that alternative procedures be used.
The following should be considered when developing a security checkpoint screening plan:
• Traffic Flow - Traffic flow should remain unobstructed as a means of minimizing the time a per-
son remains within the archway of a walk-through metal detector.
• Alternative Screening - Alternative screening methods such as scanning with a hand held
metal detector, hand searching or denial of access should be clearly defined in checkpoint
screening procedures as approved alternatives to screening with the walk-through metal detec
tor.
• Personnel Training - Security screening personnel should be instructed in the care of persons
with special medical needs and use of alternative screening methods that meet the requirements
of medical practitioners or medical device manufacturers.
TABLE OF CONTENTS
1. GENERAL DESCRIPTION 6
3. INSTALLATION INSTRUCTIONS 12
3.1 SITE SELECTION 12
3.2 ASSEMBLY 12
4. SELF-DIAGNOSTIC TESTS 15
5. INSTALLATION ADJUSTMENTS 17
6. SUPERVISOR ADJUSTMENTS 19
7. SUPERVISOR RESPONSIBILITIES 21
8. TECHNICAL SPECIFICATIONS 24
The Garrett CS 5000 Walk-Through Metal Detector features microprocessor-controlled circuitry and
LCD presentation of all calibrating and operating information. It is capable of remote operation and mon-
itoring, when required, and is designed to be easily portable. The unit can be operated on battery power
alone through use of an optional battery pack, which further enhances its portability.
The CS 5000 uses microprocessors in both its detection and control circuitry. These integrated circuits
contain the necessary elements of a small digital computer and are preprogrammed to provide discrim-
ination capabilities that enable the CS 5000 to optimally detect weapons and other devices made of
metal. At the same time, the microprocessors permit the detector to be considerably more sophisticat-
ed in its programming and provide greater flexibility in the selectivity of the metals it detects. The detec-
tor also features excellent sensitivity, stability and noise rejection. All electronics are built into an over-
head panel of the unit to eliminate problems of logistics and reliability often associated with a cable-
connected console. The LCD display on the face of the detector's overhead panel reports information
concerning the unit’s calibration and operation. This includes program data, sensitivity settings, opera-
tor settings and fault indication. A bright LED bar graph, easily visible from a distance, reports detec-
tion levels and separate lights indicate ready and alarm conditions.
All regulation and control functions are “self-prompting” with necessary commands shown automatical-
ly on the LCD. The Unit also reports a traffic count on its LCD. The system offers highly flexible capa-
bilities with a continuously variable range of programs including several that have been designed for
specific purposes. Programs are regulated by state-of-the-art touchpads and reported visually on the
LCD. Improved security of the unit’s detection settings comes from an improved system of access
codes. Two levels of codes eliminate the need for bothersome keys for locked doors or other protective
devices, while the CS 5000 circuitry provides precise accuracy of calibration. Access Code #1 is used
by supervisors for selecting programs and sensitivity with Access Code #2 designed for initial set up and
overall control. All settings are encoded by touchpads and remembered in an resettable memory.
Security of the unit’s calibration settings is further protected by a non-resettable sequence code that
allows supervisors to keep a log of all changes that are ever made as well as any unsuccessful attempts
to change them. In addition, a tamper indication reports any unauthorized attempts at access. A com-
plete and automatic self-diagnostic program is carried out by the CS 5000 each time the Operate touch
pad is pressed. In addition, the detector utilized self-testing circuitry that continuously monitors the crit-
ical functions of the detector, reporting automatically the failure of any element that would affect opera-
tion of the unit.
2.2 TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions:
2.2.1 STANDBY
When this touchpad is pressed, the unit goes into a low power mode, ready to be returned to full
operation when the OPERATE pad is touched. When STANDBY is displayed on the LCD, the green
READY light is not visible and no processing can take place in the unit. It is important to remember
that the Power Switch located on the Battery Back-up Module (See Section 11.6) should be set to
its OFF position anytime the system is being stored and anytime the system is not in use and is not
connected to AC power for more than 24 hours.
2.2.2 OPERATE
Whenever this touchpad is pressed, the CS 5000 activates all circuits, initiates a self-diagnosis pro-
gram and places the unit in the Operate Mode within fifteen (15) seconds. This diagnostic program
for instant fault detection can be activated at any time by touching this OPERATE pad. If any faults
are ever found, they will be immediately reported on the LCD display. (See Section 4.)
2.2.3 COUNTER
When this touchpad is pressed, the traffic count is displayed on the LCD display. Pressing and hold-
ing this touchpad for ten (10) seconds causes the counter to return to zero (0). Whenever the LCD
is displaying information other than the current traffic count, pressing this touchpad will cause the
count to appear along with the Sequence Number of changes that have been made to
Program/Sensitivity settings. CT (Number) and SEQ (Number) will appear. Each time the
Program/Sensitivity Mode is accessed, the Sequence Code that appears on the LCD will be
advanced one number. It is recommended that a written notation be made on the Operations
Worksheet (see Section 11.1) whenever this code is accessed, explaining reasons for the access.
If the ACCESS touchpad has been pressed and an improper access code has been entered, a * will
appear before the sequence number (SEQ *37). This indicates that an unsuccessful (unauthorized)
attempt has been made to gain access to the Program/Sensitivity setting.
2.2.4 VOLUME
When this touchpad is pressed, the volume level of the unit’s audible alarm will be shown on the
LCD display and the actual volume of the alarm will be heard. The + and - touchpads can be used
by operators to raise or lower the volume. Press OPERATE to return to the operate mode.
2.2.5 + AND -
These touchpads will be used to increase or decrease various numerical settings and for certain
On/Off functions.
2.2.6 PROGRAM
When this touchpad is pressed, the settings for Program and Sensitivity will appear on the LCD dis-
play.
2.2.7 ACCESS
The ACCESS touchpad will be used only by supervisory management personnel. It permits chang-
ing the Program and Sensitivity codes and also is used to control such functions as synchronization
of multiple units, pulse frequency, tone, etc. (See Section 5.3). The unit further protects security of
control settings by maintaining a non-resettable sequence code that indicates any attempt at seek-
ing access to the settings. When this touchpad is pressed, audio of the system will “chirp” and
ENTER CODE will be displayed on the LCD, prompting the operator to enter an access code. If no
attempt is made to enter a code, the unit will continue chirping for ten (10) seconds and return to
Operate Mode. If the operator enters an incorrect code, audio will sound a Tamper Alarm and
ACCESS DENIED will appear on the LCD for five (5) seconds. An asterisk (*) will appear on the
Sequence Counter indicating that an unsuccessful attempt has been made to access the Installation
or Program/Sensitivity Modes of the unit.
If an operator should inadvertently press the ACCESS touchpad, no further action should be taken
and the unit will return automatically to the Operate Mode in about ten (10) seconds.
SPECIAL NOTE: The above touchpad functions will be available to operators of the detector at all
times. Additional functions such as program and sensitivity settings and other adjustments neces-
sary only at installation time may be selected by pressing the ACCESS touchpad and entering a
security code.
• Connecting wires to remote alarm relays or synchronization circuitry (See Section 11.3);
• Connecting a remote console (See Section 11.5);
• Attaching the optional battery back up (See Section 11.6);
• Resetting to factory default Access Code (See Section 5.9).
Shown above is a view of the detection unit after the access door has been opened. Three metal
covers protect (from left) the POWER SUPPLY Module, CONTROLLER Module and the BATTERY
PACK Module (Optional).
POWER
This switch need be placed in the OFF position only during storage or when the unit is not being
used and is not connected to AC power for more than 24 hours. See Section 11.6.1 for installation
instructions.
3. INSTALLATION INSTRUCTIONS
3.1 SITE SELECTION
The Garrett CS 5000 should be located on a level, stable floor with no large metal items within three
(3) feet. Any nearby large metallic object can interfere with operation of the detector. Moving metal-
lic objects, such as an escalator or revolving door, close to the detector can cause false alarms. Such
alarms can also be caused by electrical interference from radio telephones, television monitors, pow-
erful electronic motors and transformers, power cables and control circuits.
Garrett’s special built-in circuitry is designed to suppress much of this electronic noise, especially X-
ray monitor horizontal synchronization signals and closed circuit television. Multiple frequencies per-
mit several CS 5000 units to operate simultaneously, in close proximity.
For information concerning the operation of multiple units, see Section 11.3.
The site for a CS 5000 should be selected with requirements for its pedestrian traffic and use in mind;
i.e. space for waiting lines, operators and areas for hand-scanning. Although the detector is effective
with traffic moving in either direction, best results are obtained when traffic enters from the side oppo-
site to the control touchpads and LCD display.
Locate the archway where it will not be subject to rain, mist or condensation. Protect the power cable
from pedestrian as well as vehicular traffic.
3.2 ASSEMBLY
NOTE: COMPLIANCE WITH REGULATORY STANDARDS REQUIRES THAT A CORD SET BE
USED FOR INSTALLATION.
3.2.1 Lay out the major pieces of the CS 5000, as shown at the right. Make certain all other attach-
mendevices are included. These should include:
• Detection Panel A
• Detection Panel B
• Detection Unit
• Crosspiece
• Power Cord
• 1/4-20x3” Screws (8)
• Finishing Washers (8)
• Warranty Card
• User’s Manual
• Operator’s Manual
• Instruction Video
• Access Code Card
• Cord Set
3.2.2 Install the Power Cord completely through one of the channels at the top of either of the Panels
as shown below. A channel can be found in each of the four corners. Select the corner that will
be convenient in relation to site selection. For overhead power connection, do not insert the
cable through a channel but leave it free at the top.
If using cord set, it must be routed through the channel closest to the Power Module. Care
should be taken to prevent accidental disconnections and exposure to water.
3.2.3 Place the styrofoam packing material on floor as shown and lay the Detection Unit on it with the
touch pad panel facing down. Use four (4) of the Screws and Finishing Washers to connect the
Detection Unit to Panels A and B. Do not tighten.
3.2.4 Open door of the Detection Unit and, first, connect Power Cord. Then, connect Cable A and
Cable B to the Panels as shown.
3.2.5 Use the remaining screws and washers to attach the Crosspiece to the two panels, as shown
3.2.7 With two or more people lift to a vertical position and move to location.
3.3.8 Check for stability of unit, which is important for proper operation and safety. If the floor proves
to be uneven, either shim a corner or slightly loosen the screws connecting the Detection Unit
and Overhead Crosspiece to the Side Panels and adjust as necessary.
3.3.9 Connect to the power line, and proceed with Installation Adjustments (See Section 5.)
4. SELF-DIAGNOSTIC TESTS
The Garrett CS 5000 LCD panel provides valuable information concerning the operation of this unit
and the self-diagnostic program of which it is capable.
Example: SELF-TEST...3..4 (Indicates that both Error 3 and Error 4 are occurring.)
The self-diagnostic/reporting cycle described above will be carried out automatically by the unit any
time the OPERATE touchpad is pressed.
If a fatal error is encountered because of component failure, broken wire, etc., the
audible alarm will sound and the LED display will begin to flash. To remedy the situation, press the
OPERATE touchpad, which will initiate the self-diagnostic routine. Note the error(s) that will appear
on the LED and follow instructions stated above. If a solution is not obvious, it will be necessary to
follow the repair procedure described in Section 9.2.
Another error indication is that of a warbling audio when a person is in the archway
(or, for an extended time if the IR Analysis is switched off). This sound indicates that
a large metallic object, such as a wheelchair, stroller, or very large hand-carried object, has “over-
loaded” the equipment to a degree that it cannot function accurately. If this sound is heard, the oper-
ator should see that the problem object is moved away, and the person being inspected should be
required to pass through the archway again after the green READY light appears.
5. INSTALLATION ADJUSTMENTS
The Installation Adjustment Mode, which can be accessed only through use of a four-digit code
(Access Code #2), permits the CS 5000 to be set up properly for best performance in a given oper-
ational environment. Various options permit setting the unit for proper operation in conjunction with
other walk-through units or for dealing with typical operation problems.
Default settings, preset at the factory, are indicated below for each of the functions in this mode. Use
the + or - touchpads to regulate any of the functions.
To access the Installation Adjustment Mode for the first time, press the ACCESS touchpad and enter
the factory preset code of 5678. Functions to be set will be displayed in the following sequence:
Pressing ACCESS will scroll through these selections:
5.2 TONE
The alarm tone is initially set at a median level. Through use of the + and - touchpads the tone level
can be raised or lowered. A corresponding number (1 to 9 ) will be displayed on the LCD panel and
the tone that has been selected will be heard. When the desired tone is reached, press ACCESS to
select the next adjustment or press OPERATE to return to normal operation.
5.3 SYNCHRONIZATION
Preset factory option is MASTER. See Multiple Unit Operation in Section 11.3 for directions on prop-
er use of this option when it is necessary.
MASTER enables the unit to operate on its own internally generated synchronization from the
power line.
SLAVE synchronizes the unit to the signal received from another CS 5000 on the Sync terminal (on
the lower center of the Controller Circuit Board).
5.4 CHANNEL
This feature will allow multiple units to operate in close proximity. It is recommended that when two
(2) units are operated in close proximity that Channels A and B are used. If three (3) or more units
are operated in close proximity, use Channels A, C and D. Do not use Channel B because it may
conflict with Channel C. See Multiple Unit Operation in Section 11.3. Press ACCESS for next adjust-
ment or OPERATE to return to normal operation.
Press ACCESS for the next adjustment or OPERATE to return to normal operation.
5.6 RELAY
This feature allows the AC and DC relay circuits to be changed easily to Normally Open (N/O) or
Normally Closed (N/C) to meet installation requirements. Use + and - touchpads to select RELAY
N/C or RELAY N/O (See Section 11.4). Press ACCESS for next adjustment or OPERATE to return
to normal operation.
6. SUPERVISOR ADJUSTMENTS
Several adjustments may be made at the Supervisor’s Level (Access Code #1). These are primari-
ly program/sensitivity settings and the operation of the IR Sensor. These supervisor’s adjustments
can be accessed only through use of a four-digit code (See instructions for altering Access Code #1
under Installation Adjustments, Section 5.7)
To access the Supervisor Adjustment Mode for the first time, press the ACCESS touchpad and the
factory preset code of 1234. The factory default settings of PROG D SENS 160 will be displayed
on the LCD with the program designation blinking. Pressing the ACCESS touchpad will permit scroll-
ing through these selections.
Special Note
For maximum security it is recommended that both Access Code numbers be changed from the fac-
tory default settings and that the numbers be known only to those who use them. Record the new
code numbers on the Access Settings card that accompanied this User’s Manual. It is also suggest-
ed that codes be changed periodically, especially when any changes are made in personnel with
access to the codes.
6.1 PROGRAM
The programs detailed in Section 11 have been developed for use by the Garrett
CS 5000. These brief descriptions will give some indication of the intent of each program, but a final
judgment on the setting of each individual unit should be determined by the intent of its installation.
After the Program number is accessed through use of the four-digit code, + touchpad can be used
to increase the number, and the - touchpad to lower it. Press ACCESS for next adjustment or OPER-
ATE to return to normal operation.
6.2 SENSITIVITY
This option permits the unit to be adjusted (range of 1 to 200) to the proper level of
sensitivity within a chosen program. Press ACCESS until the SENS and the number are displayed
on the LCD. Use the + and - touchpads to adjust the number. Sensitivity of detection will be
increased as the number is made larger, allowing alarm responses on smaller targets.
After the desired Sensitivity number has been selected, press ACCESS for next adjustment or
OPERATE to return to normal operation.
6.3 IR ANALYSIS
The Garrett CS 5000 utilizes an Infrared Sensor to enhance the operation of the unit in special sit-
uations. IR Analysis — ON or OFF appears on the LCD to indicate whether or not the IR Analysis
is being used. The + or - touchpad is used to turn the IR Analysis off and on. Whenever this is done,
it is necessary to press ACCESS for the next adjustment or OPERATE to return to normal opera-
tion.
Utilization of the Infrared Sensor is not required for operation of the CS 5000 and may be disabled
if desired.
2. By inhibiting the alarm when no one is in its archway, the IR Analysis greatly
minimizes nuisance alarms. In instances where there is movement of large metal objects near
the exterior of the unit, such as when luggage or supply carts pass by, or when lack of space
requires the unit to be placed very near a conveyor belt of parcel X-ray equipment, the sensor
will effectively inhibit alarms.
3. The IR Analysis provides a warning any time a person passes through the archway when the unit
is in the Set-Up or Self-Test Mode.
4. The IR Analysis enables the detector to count the number of individuals passing through it.
Press the ACCESS touchpad until PLEASE WAIT appears on the LCD Display, followed by ALARM
LEVEL and a number. The target in question should then be passed through the unit. Note the Alarm
Reading number that then appears on the LCD. This is the Sensitivity level that will be necessary
for the unit to sound an alarm on this target. Press the + touchpad to reset the indicator after each
measurement. It is recommended that several measurements of each object in question be made at
various archway positions to obtain the optimum sensitivity level setting.
7. SUPERVISOR RESPONSIBILITIES
7.1 CALIBRATION
Calibration settings of walk-through metal detectors are dependent upon individual
security screening requirements and, therefore, must be the responsibility of the screening
installation. Program and Sensitivity settings should be established at a level that permits the
detector to detect all forbidden objects that can be reasonably expected to appear at a particular
screening station. Actual forbidden objects should be used as targets for initial calibration.
1. Set-up Alarm: Produces two short beeps as a person is walking through the unit. This alarm
indicates that the metal detector is in a set-up mode and is not ready for operation. Wait for green
READY light (press OPERATE touchpad, if necessary). Person(s) who triggered the Set-up Alarm
must pass through the unit again.
2. Standard Alarm: Occurs when red ALARM light appears and a targeted amount of metal is
detected according to Program and Sensitivity levels.
3. Warble Alarm: Occurs when a large metal mass, such as a wheelchair, furniture or large metal
container is moved through or near the CS 5000. The large amount of metal has
saturated the detector’s receiver circuits and the warble alarm is an indicator that the operator
should correct the situation before allowing anyone to pass through the metal detector.
Calibration and verification can be performed with an Operational Test Piece (OTP), which is an
object similar in size, shape and composition to the smallest forbidden target. Once the walk-through
metal detector is properly calibrated, an OTP may be used to simulate the forbidden objects and ver-
ify calibration on a regular basis. The OTP thereby offers a generally accepted means of verifying
calibration without the necessity of having on hand actual weapons at the screening station on a
daily basis.
If the OTP does not represent a specific security requirement then a different test piece(s) should
be considered.
7.3 TESTING
It is imperative that a standard test program be developed for walk-through metal detectors within a
security system. The various tests should be made on a regular basis to ensure that each unit is
properly calibrated and is detecting metal. The OTP has been designed to serve as a basic instru-
ment for use in such a test program.
A test program should include passing the OTP and/or other objects through each metal detector at
various specified heights and horizontal positions, with the OTP (objects) held in different orienta-
tions. The number of repetitions required at each level with corresponding successful alarms should
Included in the test procedure should be the requirement that the tester be free of all metallic items,
including shoe shanks, prior to arming himself with the OTP. A hand-held metal detector can be used
to confirm that the tester is “clean” of extraneous metallic items.
This adjustment should be used only when sensitivity at ankle level needs to be increased.
7.4.1. PROCEDURE:
• Disconnect the unit from AC power source (switch off battery back-up module, if installed
• Open access door of detection unit;
• Remove the three (3) screws that hold the controller cover. Move jumpers as shown in the above
diagram to achieve the required level of boost (both jumpers must be set to the same level);
• Replace cover and reconnect power;
• Test unit to assure desired performance level.
7.4.2. APPLICATIONS:
8. TECHNICAL SPECIFICATIONS
8.1 ELECTRONICS
Digital-controlled pulse induction metal detector with microprocessors utilized in both detection and
control circuitry. Designed for tailoring specific programs to fulfill various security applications.
Electronics are modular and designed for easy plug-in and change-out.
8.2 MEMORY
All program selections and settings are maintained in electrically erasable non-volatile memory. The
unit will maintain all settings even when disconnected from power. No battery is required for memo-
ry retention.
8.5 CONNECTORS
AC switches, DC switches and synchronization are connected through a screw terminal block.
Remote indicators and remote console are connected through RJ-45 telephone- type connections.
8.6 INDICATORS
READY light indicates unit is operational; ALARM light and audible alarm are activated when target
amount of metal is detected; LED Bar Graph indicates amplitude of alarm signal.
8.8 TAMPERPROOF
Dual access codes required to set or change the operation of the unit: one level for use by superv-
iors in selecting programs and sensitivity; the other for initial set-up and overall control. Security of
the unit’s calibration settings is further protected by a non-resettable sequence code that allows
supervisors to maintain a precise log of all changes ever made to the program, sensitivity or set-up,
as well as any attempts at changing them. An audible alarm reports any unauthorized attempt at
access.
8.9 CONSTRUCTION
Attractive scratch- and mar-resistant laminate with resilient end caps; control panel and crosspieces
of heavy duty aluminum.
The unit also complies with IEC standards for Safety Requirements for Electronic Measuring
Apparatus and meets the Federal Communications Commission Class B standards for noise emis-
sion from commercial electrical equipment. It also conforms to the new European Electromagnetic
ompatibility Directive, 89/336/EEC -EN 55011, Group 2, Class B;-EN 50082-1
8.14 SYNCHRONIZATION
Multiple frequencies permit several CS 5000s to operate simultaneously in close proximity.
8.15 ELECTRICAL
Fully automatic 100 to 240 VAC, 50/60 Hertz, 55 watts; no rewiring, switching or adjustments
required. Power supply meets UL, CSA, TUV and VDE standards. Also complies with IEC standards
for Safety Requirements for Electronic Measuring Apparatus and meets the Federal
Communications Commission Class B standards for noise emission from commercial electrical
equipment.
8.16 DIMENSIONS
• Passageway interior: Width: 30” (0.76m) / Height: 80” (2 m) / Depth: 23” (0.57m)
• Overall exterior: Width: 35” (0.9m) / Height: 87” (2.2m) / Depth: 23” (0.57m)
• Shipping: Width: 33.5” (85.1cm) / Height: 91.5” (223.4cm) / Depth: 6.25”
(15.9cm) / Weight: 129 lbs. (58.6 kg)
• Open the access door of the Detection Unit and check that all connectors are
snapped securely and that all screws and nuts are in place.
• Inspect the windows of the IR Sensor to make certain they are not blocked in
any way.
• Check to make certain that the eight (8) screws that attach the Crosspiece and
Detection Unit to the Panels are in place and tight.
• Check to make certain that the archway sits flat on the floor and does not sway
or rock.
• If the power cord or cable to remote devices are at floor level, check for frayed or
broken wires. Replace immediately.
• Clean exterior surfaces with mild soap and water only. If a solvent is necessary for
heavy cleaning, use only denatured alcohol.
9.2 REPAIR
There are no user-adjustable controls inside the unit.
Should the equipment ever fail to perform properly, contact the seller for the name of the nearest field
service representative, or contact the factory.
Because the equipment is of modular design, repairs can often be made through replacement of
these plug-in modules. An illustrated parts list follows for your convenience.
If problems are site-related, see Section 3.1 or contact the factory for assistance. Many times these
problems may be resolved through the adjustment of the equipment or through relocation of the
equipment or surrounding objects.
It is necessary to test the system carefully to verify operation and the suitability of the product after
any component replacement.
16
CABLE B CONNECTOR
7
CABLE A CONNECTOR
8
15
5 13
12
9
6
14 23
17
4
18
20
19
11
21
10
9.5 WARRANTY
Garrett Electronics, Inc. (“Garrett”) warrants that this CS 5000 weapons/metal detector is protected
by the following limited parts and labor warranty for a period of 24 (twenty-four) months (the
“Warranty”).
During this 24-month period Garrett will inspect and evaluate all security equipment returned to its
authorized repair station or factory to determine if the equipment meets performance specifications.
Garrett will repair or replace at no charge to the owner all parts determined faulty. This Warranty does
not cover batteries nor any and all failures caused by abuse, tampering, theft, failure due to weath-
er, battery acid or other contaminants and equipment repairs made by an unauthorized party.
This warranty is expressly in lieu of all other warranties, expressed or implied, including the
warranty of merchantability or fitness for a particular purpose.
The Buyer acknowledges that any oral statements about the merchandise described in this contract
made by representatives, if any such statements were made, do not constitute warranties, shall not
be relied upon by the Buyer and are not a part of this contract for sale. The entire contract is embod-
ied in this writing. This writing constitutes the final expression of the parties’ agreement and is a com-
plete and exclusive statement of the terms of this agreement.
The parties agree that the sole and exclusive remedy against Seller shall be for the repair and
replacement of defective parts. The Buyer agrees that no remedy (including, but not limited to, inci-
dental or consequential damages for lost sales, lost profits, injury to person or property) shall be
available to him.
Exact control of the unit’s sensitivity is assured by a system with 200 precise and
repeatable steps for each program level, regulated by state-of-the-art touchpads and reported visu-
ally on the LCD. Improved security of the unit’s detection settings comes from a totally new system
of access codes. Two levels of codes eliminate the need for bothersome keys for locked doors or
other protective devices, while the CS 5000’s circuitry provides precise accuracy of calibration never
before achieved. Access Code #1 is used by supervisors for selecting programs and sensitivity, with
Access Code #2 designed for initial set-up and overall control. All settings are encoded by touch-
pads and stored in a resettable memory.
Security of the unit’s calibration settings is further protected by a non-resettable sequence code that
allows supervisors to keep a log of all changes that are ever made to the program, sensitivity or set
up, as well as any unsuccessful attempt at changing them. In addition, a tamper indication reports
any unauthorized attempts at access.
A complete and automatic self-diagnostic program is carried out by the CS 5000 each time the
OPERATE touchpad is pressed. In addition, the detector utilizes self-testing circuitry that enables it
to identify and report automatically the failure of elements that would affect operation of the unit.
10.8 TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions.
10.8.1 STANDBY
When this touchpad is pressed, the unit goes into a low power mode, ready to be returned to full
operation when the OPERATE pad is touched. Operators should use all touchpads only as instruct-
ed by supervisors.
10.8.2 OPERATE
When this touchpad is pressed, the CS 5000 activates all circuits, initiates a self-
diagnostic program and places the unit in the Operate Mode within 10 seconds.
This diagnostic program for instant fault detection can be activated at any time by touching this
OPERATE pad. If any faults are ever found, they will be immediately reported on the LCD display.
(See Section 4.1.1)
10.8.3 COUNTER
Since the current traffic count of the CS 5000 is usually displayed, this touchpad will be needed only
for resetting the counter. Pressing and holding this touchpad for ten (10) seconds causes the count-
er to return to zero (0). Whenever the LCD displays information other than the current traffic count,
pressing this touchpad will cause the count to appear.
10.8.4 VOLUME
When this touchpad is pressed, the volume level of the unit’s audible alarm will be
displayed on the LCD display. By using the + and - touchpads, operators can raise or lower the vol-
ume.
10.8.5 + AND -
These touchpads will be used to increase or decrease various numerical settings and for certain
On/Off functions.
10.8.6 PROGRAM
When this touchpad is pressed, the settings for Program and Sensitivity will appear on the LCD dis-
play.
All of the preceding touchpad functions will be available to operators of the detector at all times. The
ACCESS touchpad will be used only by supervisors.
• These directives will govern the response of operators to alarms and other situations that will be
encountered. The basic continuing responsibility of the operator will be to ensure that the CS 5000
operates properly at all times as indicated by its LCD panel and that ALL alarms are investigated.
As described in the CONTROLS section of this manual, CS 5000 controls are located in the top sec-
tion of the archway. If the green READY light is not visible on the control panel, press the OPER-
ATE touchpad. Operators can also adjust volume of the alarm and can reset the traffic counter.
The green READY light must always be on before anyone is permitted to enter the
archway for inspection.
The green light will “wink” whenever anyone breaks the IR beam across the archway or whenever
there is a noise “spike.” If the green READY light should ever go off and remain off, however, the
operator should immediately press the OPERATE touchpad. The detector will then institute a self-
test program with results reported on the LCD display. All traffic through the unit must be halted until
the green READY light again appears and remains constant.
• IR Fail (Error 3): Some obstruction within the unit may be blocking the IR sensor that projects
across the archway. Operator should make certain that the openings for the IR sensor on each side
of the archway, approximately 30 inches from the floor, have not been blocked in any way.
• Receiver Balance (Error 4): This problem could be caused by the presence of a large metal
object that has been placed near the unit. Operators should look for such an object and move it.
Even though these actions may temporarily solve the problems discovered by the self diagnostic pro-
gram, supervisors should be notified.
While the detector is operating, if a test ever shows a failure that severely limits or prohibits accept-
able performance of the unit, the alarm will sound and the LED display will flash. This flashing will
continue until power is removed or the cause of failure is corrected.
If an alarm sounds after the person has removed metal objects, hand scanning is mandatory to find
the source of metal sounding the alarm. This metal must always be found before a person can be
allowed to proceed.
An operator should take nothing for granted! The source that causes any alarm must be discovered.
If a concealed weapon is ever found, the operator should follow instructions that have been given by
supervisors.
It is important to remember that after power has been turned on, the CS 5000 is
operating at all times. Its IR Sensor capability inhibits the alarm only when there is no object or per-
son within the archway.
Because of the high level of design quality represented by the CS 5000 and its IR
Sensor, it can be expected to produce relatively few “nuisance alarms” when installed properly.
Nevertheless, operators should always follow instructions from supervisors about reporting them.
On rare occasions a nuisance source might trigger the alarm just as someone is passing through
the detector. An operator should never try to guess about the source of such an alarm, and it should
never be assumed that the alarm is a nuisance. There have been occasions when an individual
would intentionally bump against a detector while passing through it and try to blame an alarm on
the bump.
If an alarm sounds for any reason while a person is passing through the archway, that person must
be asked to walk through the unit again and/or be examined for metallic objects with a hand-held
detector.
Any attempt at access to the detector’s controls will also be indicated by an increase in the
SEQUENCE code as reported on the LCD display. Any unauthorized attempt at access that acti-
vates the Tamper Alarm will be indicated by this symbol (*) adjacent to the SEQUENCE code num-
ber. If the Tamper Alarm ever sounds, an operator should follow supervisor’s instructions.
10.18 COUNTER
If the current traffic count is not being reported on the LCD display, press this touchpad to view it.
Pressing and holding this touchpad for ten (10) seconds enables the operator to return the traffic
counter to zero (0). Supervisors will issue instructions concerning this control and its use by individ-
ual operators.
10.19 SUMMARY
It is important that all operators study the guidelines in this section carefully and remember their
basic responsibilities for operating the CS 5000 as stated on the first page:
Most important of all is the operator’s responsibility to make certain that every alarm be investigated
and that the reason for that alarm be determined.
The CS 5000 is a fine walk-through metal detector. But, in the end, even an electronic device as
sophisticated as this is only a tool. Ultimate success of its operation is dependent upon:
• The training and diligence of the men and women who operate it;
11 ADDITIONAL INFORMATION
11.1 OPERATIONS WORK SHEET
Location: ____________________
Version: ____________________
11.2 PROGRAMS
Note: Although different settings are required for different applications, the manufacturer
finds Program D most effective for high volume high security; Program A for low volume
maximum security; and Program 9 in loss prevention situations and in cases where noise
problems limit performance of custom programs. It is the responsibility of the user to select
and implement that program which is best suited to a particular situation.
11.2.3 PROGRAM A
• Custom program designed to detect the broadest range of objects.
• Emphasis of detection is on conductive objects. This program provides the highest level of
security available in the CS 5000.
• Immunity to external noise is moderate, making this program usable in most environments.
• Discrimination is poor.
• Recommended applications include prisons and other installations where volume require-
ments allow thorough inspection of each individual.
11.2.4 PROGRAM B
• Custom program designed to detect ferrous and conductive objects equally.
• Immunity to external noise is moderate, making this program usable in most environments.
• Discrimination is moderate.
• Recommended applications include general security.
11.2.5 PROGRAM C
• Custom program designed to detect ferrous and conductive objects equally.
• This program is optimized for the three-gun test of the Federal Aviation Administration
(FAA).
• Immunity to external noise is moderate, making this program usable in most environments.
• Discrimination is good, providing the highest throughput rate.
• Recommended applications include airports, schools, courtrooms and other high volume
installations.
11.2.6 PROGRAM D
• Custom program designed to detect ferrous and conductive objects.
• This program provides a level of security that exceeds FAA requirements.
• Discrimination is moderate to good.
• Recommended applications include airports, schools, courtrooms and other installations
requiring the maximum possible security in high volume operation.
11.2.7 PROGRAM E
• Custom program designed to detect ferrous and conductive objects. Emphasis of detection is
on conductive objects.
• Immunity to external noise is moderate, making this program usable in most environments.
• Discrimination is moderate to good.
• Recommended applications include loss prevention.
Airports, special
Detects FAA test guns, Good to excellent pre-
events, private busi-
plus the multi-composi- vents masking
nesses, gov’t buildings,
High volume traffic D tion subject to masking designed to ignore
schools, courthouses,
alloy types, iron, alu- common pocket items
hospitals, corporate
minum, steel (High throughput)
security
Correctional Facilities,
Maximum security All metal, ferrous, non- None
Loss prevention, law A
screening ferrous (Low throughput)
enforcement
Alternative when A, C,
D cannot be used due FAA 3 gun, ferrous, Mild
All applications 9
to extreme environ- non-ferrous Low Throughput
mental conditions
For proper operation, each walk-through metal detector must be set to receive no interference
from adjoining units. This can be determined by observing the bar graph indication of one unit
while switching the remaining unit(s) from Standby to Operate. If the noise flicker increases on
the BAR GRAPH of a unit, then it may be necessary to select another set-up.
11.3.1 CASE I
Description:
• Two (2) units which interfere with each other;
• Both units plugged into same power line (same circuit breaker).
Procedure:
• Set both units to MASTER ;
• Set one unit to CHANNEL A ;
• Set one unit to CHANNEL B.
Procedure:
• Set all units to Master
• Set first unit to CHANNEL A
• Set second unit to CHANNEL B
• Set third unit to CHANNEL D ;
Repeat pattern of CHANNELS A,C, and D for any additional units.
Procedure:
• Disconnect units from power line;
• Open Access Door of Detection Unit;
• Remove three (3) screws that hold controller cover;
• Use synchronization wire (18 to 24-gauge, 2 conductor) between units; connect as shown;
• Set the end unit to MASTER CHANNEL A and ensure that this unit is connected to either AC
power or battery power at all times;
• Replace covers and reconnect power;
• Set all other units to Slave;
• Repeat pattern of CHANNELS A, C, and D for any additional units.
11.4.1 AC CONTROL
Connection of an external alarm, locking device or other component may be made as shown
below. The optically-isolated triac output will conduct only during the time that the Red ALARM
light is illuminated. It is recommended that the control not exceed 48Vrms and 100mA. The output
is electrically isolated from ground.
11.4.2 DC CONTROL
The three drawings that follow illustrate alternate methods of connecting an external device which
has requirements of low voltage direct current. The output is an open collector configuration capa-
ble of switching 15V at 100mA or less, which includes connections to computing devices and
other equipment requiring low level DC.
11.5.1 INSTALLATION
• With power disconnected locate archway and console in their desired locations;
• Locate connecting wire and protect from tampering or vandalism, as necessary;
• Plug the wire into the rear of the console;
• Open the Access Door of the detection unit;
• Remove three (3) screws that hold the controller cover;
• Plug the wire into the Circuit Board connector as shown on Page 23;
• Replace covers and connect to power.
A switch is provided on the side of the battery module to fully disconnect battery power. This
switch whould be set to its OFF position anytime the system is being stored and anytime the sys-
tem is not in use and is not connected to AC power for more than 24 hours. Standby circuitry will
discharge a fully charged set of batteries in about ten (10) to fifteen (15) days whenever the switch
is not turned off.
11.6.1 INSTALLATION
1. Open the access door of the detection unit;
2. Disconnect the AC power plug from the Power Supply Module;
3. Remove the three (3) screws that hold the Controller Module Cover;
4. Remove the four (4) acorn nuts that are attached to the Battery Pack Module mounting studs;
5. Install the Battery Pack Module and replace the acorn nuts;
6. Disconnect the Power Supply Module connector on the upper left of the Controller Circuit
Board;
7. Reconnect the Power Supply Module and Battery Pack Module as shown;
8. Reassemble the system and test.
11.7.1 Examine the location and determine the best routing for the power cord.
11.7.2 For each panel, remove and discard the two (2) rubber bumpers located on the bottom of the pan-
els. these holes will be used for attaching mounting plates to panels.
11.7.3 Using the supplied 3/32” (2.3mm) drill bit, extend the depth of the mounting holes to 2” (50mm) deep.
11.7.4 Attach the plates (with the edges pointing away from the panel using the supplied 2” long screws.
CAUTION:
The power cord must be installed in the correct Panel location (see Page 8, 3.2.2) before the plate
can be secured. DO NOT PINCH the cord between the panel and the plate. Ensure that the head of
the screw is tight against the plate to prevent the panels from sliding.
11.7.7 Secure the unit to the floor using 1/4” (6mm) mounting screws (not supplied). The mounting holes in
the plates may be used as a drill guide.
Caution: Adjust the width of the unit at the bottom of the panels to 30” (762mm) BEFORE making the
holes in the next step.
Green To Ground
Black To Line Hot
White To Line Neutral
Green/Yellow To Ground
Brown To Line Hot
Blue To Line Neutral