PRODUCT DATASHEET

LCF78-50JL

7/8" CELLFLEX® Lite Low-Loss Foam-Dielectric Coaxial Cable

CELLFLEX® Lite 7/8" low loss flexible cable

FEATURES / BENEFITS
Ultra Low Attenuation
The further reduced attenuation of CELLFLEX® premium attenuation coaxial cable results in extremly
efficient signal transfer in your RF system, especially at high frequencies.
Complete Shielding
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that 7/8" CELLFLEX® Lite Low-Loss Foam
minimizes system interference. Dielectric Coaxial Cable
Low VSWR
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
Outstanding Intermodulation Performance
CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless
cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.

Technical Features

APPLICATIONS
Applications Main feed line, intended for outdoor usage
STRUCTURE
Cable Type Foam-Dielectric, Corrugated
Size 7/8"
Jacket Option Black
Inner Conductor mm (in) 9.32 (0.37) Copper Tube
Dielectric mm (in) 22.4 (0.88) Foam Polyethylene
Outer Conductor mm (in) 25.2 (0.99) Corrugated Aluminium
Jacket mm (in) 27.8 (1.09) Polyethylene, PE
ELECTRICAL SPECIFICATIONS
Impedance ȍ 50 +/- 1
Maximum Frequency GHz 5.0
Velocity % 90.0
Capacitance pF/m (pF/ft) 75 (22.9)
Inductance µH/m (µH/ft) 0.1875 (0.057)
Peak Power Rating kW 85.0
RF Peak Voltage Volts 2920.0
Jacket Spark Volt RMS 8000.0
Inner Conductor dc Resistance ȍm ȍft) 1.54 (0.47)
Outer Conductor dc Resistance ȍm ȍft) 1.42 (0.43)
Return Loss (VSWR) Performance Standard
Maximum Return Loss dB (VSWR) 24 (1.135)
Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request.
Temperature & Power Standard
MECHANICAL SPECIFICATIONS
Cable Weight kg/m (lb/ft) 0.34 (0.23)
Minimum Bending Radius, Single Bend mm (in) 120 (5)
Minimum Bending Radius, Repeated Bends mm (in) 250 (10)
Bending Moment Nm (lb*ft) 13
Tensile Strength N (lb) 1440 (324)
Recommended / Maximum Clamp Spacing m (ft) 0.8 / 1 (2.75 / 3.25)

LCF78-50JL REV: D REV DATE: 11.Dec.2013 www.rfsworld.com

All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 1 of 2
PRODUCT DATASHEET
LCF78-50JL

7/8" CELLFLEX® Lite Low-Loss Foam-Dielectric Coaxial Cable

ATTENUATION AND POWER RATING


Frequency Attenuation Power TESTING AND ENVIRONMENTAL
MHz dB/100m dB/100ft kW Fire Performance Halogene Free
0.5 0.09 0.027 85.00 Installation Temperature -40 to 60 (-40 to 140) °C(°F)
1 0.12 0.038 85.00 Storage Temperature -70 to 85 (-94 to 185) °C(°F)
1.5 0.15 0.046 70.20 Operation Temperature -50 to 85 (-58 to 185) °C(°F)
2 0.17 0.053 60.60
10 0.39 0.119 27.00
20 0.56 0.17 19.10
30 0.68 0.208 15.50
50 0.89 0.27 12.00
88 1.18 0.36 8.98
100 1.26 0.384 8.41
108 1.31 0.40 8.09
150 1.55 0.473 6.84
174 1.67 0.51 6.35
200 1.80 0.549 5.89
300 2.22 0.677 4.77
400 2.58 0.786 4.11
450 2.74 0.837 3.87
500 2.90 0.884 3.66
512 2.94 0.895 3.61
600 3.19 0.973 3.32
700 3.46 1.06 3.06
750 3.59 1.10 2.95
800 3.72 1.13 2.85
824 3.78 1.15 2.80
894 3.95 1.20 2.68
900 3.96 1.21 2.68
925 4.02 1.22 2.64
960 4.10 1.25 2.59
1000 4.19 1.28 2.53
1250 4.72 1.44 2.25
1400 5.02 1.53 2.11
1500 5.21 1.59 2.03
1700 5.58 1.70 1.90
1800 5.76 1.76 1.84
2000 6.10 1.86 1.74
2100 6.27 1.91 1.69
2200 6.43 1.96 1.65
2400 6.75 2.06 1.57
2500 6.90 2.10 1.54
2600 7.05 2.15 1.50
2700 7.20 2.20 1.47
3000 7.64 2.33 1.39
3500 8.33 2.54 1.27
4000 8.98 2.74 1.18
4900 10.10 3.07 1.05
5000 10.20 3.11 1.04

Attenuation at 20°C (68°F) cable temperature;


tolerance +/- 5% max.; Mean power rating at
40°C (104°F) ambient temperature

External Document Links Notes


Installation Instruction

LCF78-50JL REV: D REV DATE: 11.Dec.2013 www.rfsworld.com

All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 2 of 2