Series 2000 Instruments: LM2-CLMD - Replacement Display For CLM200 and CLM220 Installation Guide
Series 2000 Instruments: LM2-CLMD - Replacement Display For CLM200 and CLM220 Installation Guide
Series 2000 Instruments: LM2-CLMD - Replacement Display For CLM200 and CLM220 Installation Guide
42TM20-31
Revision A
© Copyright 2009 National Oilwell Varco LP. All rights reserved.
NOV is a registered trademark of National Oilwell Varco I/P, Inc. Registered U.S. Patent & Trademark
Office. This publication is the property of, and contains information proprietary to, National Oilwell Varco,
Inc. No part of this publication may be reproduced or copied in any form, or by any means, including
electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of
National Oilwell Varco, Inc. All product, brand, or trade names used in this publication are the
trademarks or registered trademarks of their respective owners.
Overview
The LM2-CLMD has been designed to retrofit the CLM220/200 unit
display, and has been specifically configured to replace the original
CLM display unit. The LM2-CLMD is designed for mounting on a
customer supplied console. Install the unit using the instructions
listed below.
42TM20-31 1-1
Quick Reference Guide
Installation
The LM2-CLMD has a new bracket in the installation kit that can be
used to install the unit. If the existing original CLM220/200 bracket
cannot be removed, the installation kit has adaptors to allow the LM2-
CLMD to fit in the existing bracket. The following installation steps
show how to install the LM2-CLMD using the existing bracket and
instructions for the new bracket, depending on which type of
installation is being done. Power down the CLM220/200 main CPU
unit prior to installation of the LM2-CLMD and perform the steps
below:
1. If not already done, disconnect cable (MDT P/N XC040-30)
from old CLM 220/220 display. Remove the old display from
the bracket and remove the bracket, if applicable.
2. If the replacement bracket is to be used, secure the bracket
with nuts and bolts or by welding it into the desired location.
3. If the existing bracket is being used, screw the adapters to the
display. If the new bracket provided in the kit is being used, skip
this step.
Adapters
ExistingExisting
BracketBracket
Replacment Bracket
42TM20-31 1-3
Quick Reference Guide
Electrical Installation
The connection between the CPU and display is accomplished as
outlined below:
1. On the circuit board of the CLM220 main CPU (usually
mounted on the crane cabin wall) place the Berg jumper (P/N
H10555A) on JP6 as seen in Figure 1-1.
42TM20-31 1-5
Quick Reference Guide
Cable
42TM20-31 1-7
Quick Reference Guide