ZXRAN V9200 Product Description
ZXRAN V9200 Product Description
ZXRAN V9200 Product Description
TABLE OF CONTENTS
1 Overview............................................................................................................................6
1.1 Introduction......................................................................................................................... 6
1.2 Benefits................................................................................................................................7
1.3 Application Scenarios........................................................................................................7
2 Product Architecture................................................................................................... 10
2.1 Physical Structure............................................................................................................10
2.2 Hardware Structure......................................................................................................... 11
2.2.1 Switching Board (VSW).................................................................................................. 11
2.2.2 Baseband Processing Board (VBP)............................................................................. 14
2.2.3 Environment Monitoring Board (VEM)......................................................................... 24
2.2.4 Power Distribution Board (VPD)....................................................................................27
2.2.5 Fan Array Module (VF)................................................................................................... 27
2.3 Functionality..................................................................................................................... 28
3 Technical Specifications.............................................................................................29
3.1 Physical Specification..................................................................................................... 29
3.2 Capacity............................................................................................................................ 29
3.3 Power Specification.........................................................................................................30
3.3.1 Power Supply................................................................................................................... 30
3.3.2 Power Consumption........................................................................................................30
3.4 Environment Specification..............................................................................................30
3.5 Electromagnetic Compatibility Specification............................................................... 31
3.6 Reliability Specification................................................................................................... 31
5 Abbreviations.................................................................................................................44
FIGURES
TABLES
1 Overview
1.1 Introduction
NOTE: In this document, G is short for GSM, U is short for UMTS, F is short for FDD LTE,
T is short for TDD LTE, I is short for NB-IoT, and N is short for 5G NR. L is short for LTE,
which can be FDD LTE or TDD LTE.
1.2 Benefits
The V9200 supports multiple radio access modes, including GSM, UMTS, LTE,
NB-IoT and 5G. All RATs share the common controlling and transmission resources.
You can implement a smooth evolution from GSM/UMTS/LTE to 5G by
corresponding boards or software configuration.
Large Capacity
The V9200 is small in size (19-inch wide and 2U high). It can be conveniently
mounted on a wall or inserted in a 19-inch cabinet or an outdoor site-supporting
cabinet, thus saving a lot of installation space and achieving co-site with other
devices easily.
Flexible Networking
The V9200 supports both indoor and outdoor applications. In the indoor scenario, the
V9200 is typically inserted in the indoor L-Rack-I1 or any standard 19-inch cabinet
offered by the operator. In the outdoor scenario, the V9200 is typically put in the
all-in-one outdoor cabinet BS9900A (VC9910A+PC9910A). When multi-BBUs are
required to be deployed in the central equipment room, the indoor cabinet VC9810 is
recommended. The typical application scenarios of the V9200 are shown in the following
figures.
2 Product Architecture
The V9200 consists of Power Distribution Board (VPD), Baseband Processing Board
(VBP), Environment Monitoring Board (VEM), Switching Board (VSW) and Fan Array
Module (VF), as listed in Table 2-1.
VSW is the switching board, used to control and manage the baseband unit as well as to
provide transmission interfaces and system clock. There are four types of VSW boards:
VSWc0, VSWc2, VSWd1 and VSWd2, illustrated as follows.
Interface Description
Interface Description
ETH3 – ETH4 100GE optical interface, used for backhaul transmission (reserved)
GSM
Processing 216 TRXs 216 TRXs 216 TRXs 216 TRXs
Capability
UMTS
Processing 48 CSs 48 CSs 48 CSs 48 CSs
Capability
90 20M cells,
LTE 90 20M cells, 90 20M cells, DL 90 20M cells, DL
DL 14.4
Processing DL 7.2 Gbps/UL 9 Gbps/UL 4.5 12 Gbps/UL 6
Gbps/UL 7.2
Capability 3.6 Gbps Gbps Gbps
Gbps
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
VSWc0 accomplishes LTE control plane and service plane protocols processing,
including S1AP, X2AP, RRC, PDCP etc.
Supports Ethernet switching function and implements data switching for service and
control flow within the system.
Provides a real-time clock for system operation and maintenance and calibrates the
real-time clock.
Provides a USB interface for software upgrading and base station commissioning.
VBP is the baseband processing board, which processes the physical layer protocols
and frame protocol specified by 3GPP. There are seven types of BP boards: VBPc0,
VBPc1, VBPc5, VBPc7, VBPd0, VBPd1 and VBPd2.
2.2.2.1 VBPc0
Mode Capacity
GSM 72 TRXs
UFI multi-mode 12 UMTS CSs (768 CEs) + 6 FDD LTE Cells+ 3 NB-IoT Carriers
GUI multi-mode 36 GSM TRXs + 6 UMTS CSs (384 CEs) + 6 NB-IoT Carriers
FTI multi-mode 6 FDD LTE Cells + 6 TDD LTE Cells + 3 NB-IoT Carriers
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
2T2R/2T4R/4T4R.
Interface Description
2.2.2.2 VBPc1
Mode Capacity
Mode Capacity
GUI multi-mode 18 GSM TRXs + 24 UMTS CSs (1536 CEs) + 6 NB-IoT Carriers
UFI multi-mode 12 UMTS CSs (768 CEs) + 12 FDD LTE Cells + 6 NB-IoT Carriers
GFT multi-mode 12 GSM TRXs + 9 FDD LTE Cells + 6 TDD LTE Cells
FTI multi-mode 12 FDD LTE Cells + 6 TDD LTE Cells + 6 NB-IoT Carriers
GUFTI 18 GSM TRXs + 6 UMTS CSs (384 CEs) + 6 FDD LTE Cells + 6
multi-mode TDD LTE Cells + 3 NB-IoT Carriers
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
2T2R/2T4R/4T4R.
Interface Description
OF1 – OF6 10/25 Gbps SFP+/SFP28 interface, used for connecting to RRUs/AAUs
Note: Table 2-6 describes the maximum hardware capability. The real interface configuration is up
2.2.2.3 VBPc5
Mode Capacity
Note: The above table describes the maximum hardware capability. The actual capability is up to
Interface Description
2.2.2.4 VBPc7
Mode Capacity
GSM 36 TRXs
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. Both FDD LTE and NB-IoT supports 2T2R/2T4R/4T4R.
Interface Description
Note: Table 2- 12 describes the maximum hardware capability. The real interface configuration is
2.2.2.5 VBPd0
Mode Capacity
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
Interface Description
2.2.2.6 VBPd1
Mode Capacity
GUF multi-mode 12 GSM TRXs + 6 UMTS CSs (512 CEs) + 12 FDD LTE Cells
UFI multi-mode 6 UMTS CSs (384 CEs) + 12 FDD LTE Cells + 6 NB-IoT Carriers
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
Interface Description
2.2.2.7 VBPd2
Mode Capacity
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
Interface Description
VEM is an environment monitoring board. There two types of VEM boards: VEMc1 and
VEMc2.
2.2.3.1 VEMc1
Interface Description
EAM2 – EAM3 RJ45 interface, providing 4 input dry contacts each, totally 8 input
dry contacts
Supports 12 site alarm dry contacts, including 4 bidirectional and 8 input contacts
2.2.3.2 VEMc2
Interface Description
Interface Description
EAM2 – EAM4 RJ45 interface, providing 4 input dry contacts each, totally 12 input
dry contacts
Supports 16 site alarm dry contacts, including 4 bidirectional and 12 input contacts
2.2.3.3 VEMc4
Interface Description
EAM2 – EAM3 RJ45 interface, providing 4 input dry contacts each, totally 8 input
dry contacts
Supports 12 site alarm dry contacts, including 4 bidirectional and 8 input contacts
Interface Description
2.3 Functionality
Supports flexible installation modes, including installation on the wall, in the 19-inch
standard cabinet and the outdoor site-supporting cabinet.
3 Technical Specifications
Item Value
3.2 Capacity
Mode Capacity
UMTS 48 CSs
Note: 1. The above table describes the maximum hardware capability. The actual capability is up to
the licenses configured. 2. The multi-mode capacity can be calculated according to the capacity of
the configured boards. 3. LTE can be FDD LTE or TDD LTE, where FDD LTE supports
Item Requirement
The reliability of the V9200 system conforms to BELLCORE SR-332 Reliability Prediction
Procedure for Electronic Equipment.
Item Specification
Availability ≥99.999821%
When deployed outdoor, the V9200 is typically put into the outdoor cabinet with certain
waterproof and dust-proof capabilities, satisfying different accommodation requirements
on power, transmission or other third-party equipment.
The VC9910A is an all-in-one outdoor cabinet. It contains the following units: Baseband
Unit (BBU), AC/DC power system, heat exchanger, optional heater, lightning protection
unit (LPU), and DC power distribution unit (DCPD). In addition, it provides spare space
for accommodating other devices.
Battery cabinet PC9910A is adopted for containing 2 sets of batteries to provide power
supply in the short time power failure.
The internal structure of the VC9910A (with ZXDU68 B201) is shown in Figure 4- 2.
1. Fan and ventilation vessel 2.AC/DC power system 3. V9200 4. DC Power Distribution (DCPD)
5.Reserved 5U space for transmission etc 6. Heater or Lightning Protection Unit (LPU) 7. Heat
exchanger
The internal structure of the VC9910A (with ZXDU68 B351) is shown in Figure 4- 3.
1. Fan and ventilation vessel 2.ZXDU68 B351 3. V9200 4. Reserved 6U space for transmission etc.
1. Battery 2. Fan
The physical specifications of the VC9910A and PC9910A are specified in Table 4- 1.
Dimension (mm)
800 x 600 x 600 800 x 600 x 600
(H x W x D)
Note: If needed, a top cover and a cabinet base are configured with respectively 15mm x 600mm x
VC9910A 60W
PC9910A 0
ZXSDR BS8906B is an outdoor cabinet, used to contain the BBU in the outside
environments. Thanks to its small size and low weight, it can be hung on a pole or
against a wall. It can also stand on the floor. Figure 4- 5 shows the appearance of the
BS8906B.
There are mainly four parts in the BS8906B: baseband unit (BBU), DC power distribution
module (DCPD), heat exchange system and 1U reserved space for transmission or other
equipment. The heat exchange system consists of fan shelves for internal and external
air circulation, a fan control element (FCE) located in the monitoring unit and a side heat
exchanger. The monitoring unit is composed of fan control system and environment
monitoring system.
The lightning protection unit (LPU), transmission equipment and heating film (when it is
lower than -20°C) can be optionally configured as required. Figure 4- 6 shows the internal
structure of the BS8906B.
Item Specification
BS8906B 20W
1. DCPD 2. Power Division Unit 3. ZXRAN V9200 4. Cabling and Ventilation Subrack 5. Fake
Panel
Item Specification
Inner Space 47 U
As a multi-BBU indoor rack, ZXRAN VC9811 supports at most 3 BBUs, which is usually
applied indoor in a medium-scale BBU deployment. It contains 1 Direct Current Power
Distributor (DCPD), 1 optional Power Division Unit (including the GPS arrester, power
divider, cabling and ventilation subrack), at most 3 V9200, and 3 cabling and ventilation
subracks.
Item Description
Inner Space 20 U
When the indoor space is narrow and tight, ZXRAN VC9182 is a best choice for the
operator, not occupying floor installation area. VC9182 is usually mounted vertically on a
wall in an equipment room for holding ZXRAN V9200, illustrated in Figure 4- 11. It
contains 1–2 DCPDs and 1 V9200.
1. DCPD 2. V9200
Item Description
Inner Space 4U
In the indoor scenario, the V9200 is typically put in the indoor L-Rack-I1, as shown in
Figure 4- 12. One L-Rack-I1 maximally supports 2 BBUs, 1DCPD and dual-layer 6 RRUs
or single-layer 3 RRUs. There is still at least 9U spare room reserved for other equipment,
including transmission devices etc.
1. Reinforcing panel for mounting on a wall or connecting to an overhead cable rack 2. Second
layer for 3 RRUs 3. Second layer cable chute 4. First layer for 3 RRUs 5. First layer cable chute 6.
Item Specification
In the indoor scenario, the V9200 can be simply put in the indoor H-Rack, as shown in
Figure 4- 13. One H-Rack maximally supports 3 BBUs.
Item Specification
Inner space 33 U
ZXRAN VC9183 is an indoor BBU vertical installation shelf, which is installed in the
indoor standard 19 inch cabinet provided by the customer, making full use of the
remaining space of the existing cabinet. The internal space of the VC9183 can contain at
most 5 V9200s, and the installation height is required to be 16U. Its physical structure is
shown in Figure 4- 13.
1. Rear ventilation (air out) 2. ZXRAN V9200 3. Front ventilation (air in)
Item Specification
5 Abbreviations
Abbreviation Full Name
3GPP 3rd Generation Partnership Project
BP Baseband Processing
DL Downlink
FE Fast Ethernet
GE Gigabit Ethernet
UE User Equipment
UL Uplink