Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Test Report: Applicant Address

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

检测报告

Test Report
报告编号 A219027363910114E 第 1 页 共 7 页
Report No. A219027363910114E Page 1 of 7

申请单位 浙江合兴电子元件有限公司
Applicant CWB ELECTRONICS (ZHE JIANG) CO.,LTD.
地 址 浙江省乐清市虹桥镇幸福东路 1098 号
Address 1098,XINGFU ROAD (EAST),CWB INDUSTRIAL ZONE,HONGQIAO,YUEQING,ZHEJIANG

以下测试之样品及样品信息由申请者提供并确认
The following sample(s) and sample information was/were submitted and identified by/on the behalf of
the client
样品名称 连接器
Sample Name Connector
客户参考信息 请参见第 6 页
Client Reference Information Please refer to the page of 6
材料名称 QSn6.5-0.1Y
Material QSn6.5-0.1Y
样品接收日期 2019.10.17
Sample Received Date Oct. 17, 2019
样品检测日期 2019.10.17-2019.10.30
Testing Period Oct. 17, 2019 to Oct. 30, 2019

检测要求 根据客户要求, 对所提交样品中的铅(Pb), 镉(Cd), 汞(Hg), 六价铬(Cr(VI))


进行测试。
Test Requested As specified by client, to test Lead(Pb), Cadmium(Cd), Mercury(Hg),
Hexavalent Chromium(Cr(VI)) in the submitted sample(s).

检测依据/检测结果 请参见下页。
Test Method/Test Result(s) Please refer to the following page(s).

主 检 审 核
Tested by Reviewed by

批 准 日 期
2019.10.30
Approved by Date
张琳
技术经理 Technical Manager
No. R425003660
宁波市华测检测技术有限公司 宁波高新区菁华路 76 号厂区东首第一、二层
Centre Testing International (Ningbo) Co.,Ltd. 1-2F, Eastern Factory, No.76, Jinghua Road, High-Tech Zone, Ningbo, Zhejiang, China
检测报告
Test Report
报告编号 A219027363910114E 第 2 页 共 7 页
Report No. A219027363910114E Page 2 of 7

******************************************************************************************
结论 Conclusion
测试样品 依据标准/指令 结果
Tested Sample According to standard/directive Result
欧盟 RoHS 指令 2011/65/EU 及其修订指令
提交样品 (EU) 2015/863 符合
Submitted Sample RoHS Directive 2011/65/EU with PASS
amendment (EU) 2015/863
******************************************************************************************
符合表示检测结果满足欧盟RoHS指令2011/65/EU及其修订指令(EU) 2015/863要求的限值。
PASS means that the results shown on the report comply with the limits set by RoHS Directive 2011/65/EU with amendment (EU)
2015/863.
检测报告
Test Report
报告编号 A219027363910114E 第 3 页 共 7 页
Report No. A219027363910114E Page 3 of 7
检测依据 Test Method
测试项目 测试方法 测试仪器
Tested Item(s) Test Method Measured Equipment(s)
IEC 62321-5:2013
铅 Lead(Pb) 参考 IEC 62321-5:2013 ICP-OES
Refer to IEC 62321-5:2013
IEC 62321-5:2013
镉 Cadmium(Cd) 参考 IEC 62321-5:2013 ICP-OES
Refer to IEC 62321-5:2013
IEC 62321-4:2013+AMD1:2017 CSV
汞 Mercury(Hg) 参考 IEC 62321-4:2013+AMD1:2017 CSV ICP-OES
Refer to IEC 62321-4:2013+AMD1:2017 CSV
六价铬 Hexavalent Chromium(Cr(VI)) IEC 62321-7-1:2015 UV-vis

检测结果 Test Result(s)

结果 Result 方法检出限 限值
测试项目 Tested Item(s)
001 002 MDL Limit
铅 Lead (Pb) 16 mg/kg 53 mg/kg 2 mg/kg 1000 mg/kg
镉 Cadmium (Cd) N.D. N.D. 2 mg/kg 100 mg/kg
汞 Mercury (Hg) N.D. N.D. 2 mg/kg 1000 mg/kg
▼ ▼ 0.10 µg/cm²
六价铬 Hexavalent Chromium (Cr(VI)) N.D. N.D. 1000 mg/kg
(LOQ)
样品/部位描述 Sample/Part Description
001 金属基材 Metal base
002 银色镀层 Silvery plating

备注: 对于检测铅, 镉, 汞之样品已完全溶解。


-N.D. = 未检出 (小于方法检出限或定量限)
-mg/kg = ppm = 百万分之一
-1000 mg/kg = 0.1%
-LOQ = 定量限,六价铬的定量限为 0.10 μg/cm2
-▼六价铬浓度小于 0.10 μg/cm2, 样品未检出六价铬。
Remark: The sample(s) had been dissolved totally tested for Lead, Cadmium, Mercury.
-MDL = Method Detection Limit
-N.D. = Not Detected (<MDL or LOQ)
-mg/kg = ppm = parts per million
-1000 mg/kg = 0.1%
-LOQ = Limit of Quantification, The LOQ of Hexavalent chromium is 0.10 µg/cm2
-▼The sample is negative for Cr(VI) − The Cr(VI) concentration is below 0.10 μg/cm2. The coating
is considered a non-Cr(VI) based coating.
检测报告
Test Report
报告编号 A219027363910114E 第 4 页 共 7 页
Report No. A219027363910114E Page 4 of 7
检测流程 Test Process
1. 铅 Lead(Pb), 镉 Cadmium(Cd)
(1) IEC 62321-5:2013

(2) 参考 IEC 62321-5:2013 Refer to IEC 62321-5:2013


检测报告
Test Report
报告编号 A219027363910114E 第 5 页 共 7 页
Report No. A219027363910114E Page 5 of 7
2. 汞 Mercury(Hg)
(1) IEC 62321-4:2013+AMD1:2017 CSV

(2) 参考 IEC 62321-4:2013+AMD1:2017 CSV Refer to IEC 62321-4:2013+AMD1:2017 CSV

3. 六价铬 Hexavalent Chromium(Cr(VI))


检测报告
Test Report
报告编号 A219027363910114E 第 6 页 共 7 页
Report No. A219027363910114E Page 6 of 7
客户参考信息 Client Reference Information
TJC0501、TJC1002、TJC1003、TJC1004、TJC1006、TJC1007、TJC1008、TJC1501、ZH、PH、SAN、
SANW(JC20) 、SCN、SCNW(JC25) 、TJC15(SH) 、TJC19、TJC2004、VH、TJC1、TJC2、TJC3、TJC4、
EH、EI、JL、LP、M63、EL、MR、SM、TJC9、TJC2508、TJC14、TJC25、TJC31、TJC2503、TJC2509、
TJC2510、TJC2511、TJC25415、TJC8、TJC21、TJC3001、SDN、TJC6、TJC3965、TJC3966、VH、WH
(CH43) 、CZ34、CH34、TJC4501、TJC6201、TJC52、TJC27、TJC2512、250(CH198) 、TJC28、TJC5007、
FL、TJC1256、TJC59、TJC0508、TJC20041、GDJK10001、GDJK04001、TJC12510、TJC0402、TJC10010、
TJC10012、TJC3969、TJC20033、TJC1009、TJC1255、CH99、CH206、TJC25456、TJC25014、CH209、
TJC6202、CH211、TJC41、CZ367、TJC2B、TJC10、L6.2、CH218、CH219、CH161、CH160、TJC25460、
TJC25028、TJC20041、CH243、CH251、CH218B、CH219B、TJC25416、TJC20010、CZ126、TJC12、
PHD 、CH-TJC80001、TJC1507、TJC79203、TJC25035、CH-TJC12512-2*nA、TJC10020、IL-Z、RY04、
RY05、IL-FPC、TJC35006、CH301、TJC25040、TJC12515、TJC1255、TJC25472、CH295、CH296、CH298、
CH301、CH285、TT6.0、TJC20055、TJC50013、CZ39-3、CH34-2、TJC80001、TJC25041、CZ572、TJC86001、
TJC25476、TJC25477、TJC39615、TJC64001、TJC25475、TJC20064、TJC25046、CH-TJC92001、CH-TJC25058、
CH-TJC10025、3002、FN10C、3014、TJC20070、CH-TJC20070、C30502、2405-31、2405-41、TJC20078、
TJC12517-CZ、CH-TJC20074、CZ-TJC20074
检测报告
Test Report
报告编号 A219027363910114E 第 7 页 共 7 页
Report No. A219027363910114E Page 7 of 7

样品图片
Photo(s) of the sample(s)
001, 002

A219027363910114

*** 报告结束 ***


*** End of Report ***

声明 Statement:
1.检测报告无批准人签字、“专用章”及报告骑缝章无效;
This report is considered invalid without approved signature, special seal and the seal on the perforation;
2.样品及样品信息由申请者提供,申请者应对其真实性负责,CTI 未核实其真实性;
The sample(s) and sample information was/were provided by the client who should be responsible for the
authenticity which CTI hasn’t verified;
3.本报告检测结果仅对受测样品负责;
The result(s) shown in this report refer(s) only to the sample(s) tested;
4.未经 CTI 书面同意,不得部分复制本报告;
Without written approval of CTI, this report can’t be reproduced except in full;
5.如检测报告中的英文内容与中文内容有差异,以中文为准。
In case of any discrepancy between the English version and Chinese version of the testing reports (if generated),
the Chinese version shall prevail.

You might also like