Test Report: Intertek Testing Services Korea LTD
Test Report: Intertek Testing Services Korea LTD
Test Report: Intertek Testing Services Korea LTD
APPLICANT : LT Materials
ADDRESS : 57, Donghanggongdan-gil, Yangseong-myeon,
Anseong-si, Gyeonggi-do, Korea
PAGE: 1 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
* Note 1 : The test results presented in this report refer only to the object tested.
* Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.
* Note 3 : This report is not related to the scope of Korea laboratory accreditation scheme.
Authenticity check
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 2 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
With reference to
IEC 62321-4 Edition 1.0 :
Mercury (Hg) ㎎/㎏ 2 N.D.
2013, by acid digestion and
determined by ICP-OES
With reference to
IEC 62321-7-1
Hexavalent Chromium (Cr 6+) Edition 1.0 : 2015,
㎍/㎠ 0.10 Negative
(For metal) by boiling water extraction
and determined by UV-VIS
Spectrophotometer
Tested by : Jooyeon Lee, Seulgi Park
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 3 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 4 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 5 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 6 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
Flow Chart
(IEC62321 Edition 1.0)
Receipt
Sampling/
Grinding or Cutting
Polymers /
Metal
Electronics
For different material, Weigh sample
digest the sample with Weigh sample and add organic
2
appropriate acid*1 Get 50cm sample solvent
Soluble by NMP YES
No
Soxhlet extraction
Confirm the tested or solvent extraction
Boiling water Add alkaline/ Completely dissolved and
samples are toluene solution then add alkaline solution
totally dissolved*2 extraction
Heating
Concentrate the
Cool and filter extract and make up
Make up with the extract with organic solvent
deionized water
Data
Report
Remarks :
*1 : List of appropriate acid :
Material Acid added for digestion
Polymers HNO3, HCl, HF, H2O2, H3BO3
Metals HNO3, HCl, HF
Electronics HNO3, HCl, H2O2, HBF4
*2 : The samples were dissolved totally by pre-conditioning method according to above flow chart.
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 7 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
Receipt
Sample preparation
Sample measurement
Microwave digestion
NO with HNO3 / HCl / HF
Total digestion
YES
Analyzed by ICP-OES
Data
Report
** Remarks : The samples were dissolved totally by pre-conditioning method according to above flow chart.
※ You can verify the forgery and authenticity by the barcode at the end of this document.
TEST REPORT
PAGE: 8 of 8
REPORT NO. RT19R-S4462-006-E DATE: Oct. 10, 2019
SAMPLE ID NO. : RT19R-S4462-006
SAMPLE DESCRIPTION : HSE-04
Receipt
Sample preparation
Extraction
Concentration
Clean-up
Concentration
Analyzed by GC-MS
Data
Report
This report is made solely on the basis of your instructions and / or information and materials supplied by you and provide no warranty on the tested
sample(s) be truly representative of the sample source. The report is not intended to be a recommendation for any particular course of action, you
are responsible for acting as you see fit on the basis of the report results. Intertek is under no obligation to refer to or report upon any facts or
circumstances which are outside the specific instructions received and accepts no responsibility to any parties whatsoever, following the issue of the
report, for any matters arising outside the agreed scope of the works. This report does not discharge or release you from you r legal obligations and
duties to any other person. You are the only one authorized to permit copying or distribution of this report (and then only in its entirety). Any such
third parties to whom this report may be circulated rely on the content of the report solely at their own risk.
※ You can verify the forgery and authenticity by the barcode at the end of this document.