Septic Vault Detail: Vicinity Map
Septic Vault Detail: Vicinity Map
Septic Vault Detail: Vicinity Map
CO CO CO VTR (VENT THRU ROOF) BARS spaced every 0.30 m. O.C & HORIZONTAL
150
SD VSTR
FD
VSTR SD VSTR BARS spaced @ 0.60 m O.C AIR AND WATER
TIGHT SCUM
400
MAIN VENT
WC WC WC OUTLET INLET
BRASS COUNTER
FD FD LAV FD SUNK TYPE
LEACHING
2000
LAV LAV CHAMBER
1700
c.o c.o
CO DIGESTIVE CHAMBER
OUTLET
INLET FINE GRAVEL
400
KS OF OPENING
SLUDGE 2% SLOPE
150 mm THK. CONC.
CO
0.20 m. O.C
400
3400 BARS spaced
4" dia. PVC
@ 0.30 mO.C
1600
KS
SITE SEPTIC VAULT DETAIL 4000
350 1 3
500 4"x 1" FLAT BARS 4" O.C
W/ 2 COATS OF EPOXY
PAINTS
500
INLET OUTLET
UP
DS DS DS DS DS DS
CB INLET CB FD 1" x 1" ANGLE BARS (TYP.)
FD
ST W/ 2 COATS OF EPOXY
OUTLET PAINTS
TO MAIN
CANAL TO MAIN
CANAL SECOND FLOOR THIRD FLOOR
TO MAIN
PLUMBING LAY-OUT PLUMBING LAY-OUT
SEWER
MP
WATER METER BASE DS DOWN SPOUT MP MOTOR PUMP
GATE VALVE
M
SECOND FLOOR THIRD FLOOR
GENERAL NOTES
CHECK VALVE WATER LINE LAY-OUT WATER LINE LAY-OUT 1. ALL SANITARY WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE NATIONAL SPECIFICATION
PLUMBING CODE OF THE PHILIPPINES. THE NATIONAL BUILDING CODE OF THE PHILIPPINES AND ITS IMPLEMENTING 1. USE PVC BLUE PIPE FOR ANY COLD WATERLINE SIZE AS INDICATED.
FROM WATER RULES AND REGULATIONS. 2. FOR SOLID AND WASTE PIPE USED 2" DIAMETER , 4" DIAMETER POLYVINLY
SOURCE 2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS. THE ARCHITECT AND/OR THE
GROUND FLOOR CHLORIDE (PVC) SERIES 1000 , ATLANTA OR ANY APPROVED , 6" DIAMETER
ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN HIS/HER DECISION SHALL BE AND ABOVE CLASS 35 W/ ALL SOLVENT JOINT FITTING ONLY.
WATER LINE LAY-OUT FINAL. 3. FOR VENT PIPES USED POLYVINLY CHLORIDE (PVC) SERIES 1000 WITH ALL
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ANY RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER SOLVENT JOINT FITTING ONLY , ATLANTA OR ANY BRAND APPROVED EQUAL.
TRADES SHALL BE PRIOR APPROVAL OF THE ARCHITECT AND OR ENGINEER. 4. DRAINAGE PIPE SHOULD BE USE WITH 2" DIAMETER TO 4" DIAMETER SERIES
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF THE 1000 , 6" DIAMETER AND ABOVE CLASS 35 WITH ALL SOLVENT JOINT FITTING ONLY ,
EXISTING PIPES AND STRUCTURES VERIED BY THE CONTRACTOR. OUTSIDE BUILDING USED CONCRETE PIPE.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED FLOOR AND WALL OPENINGS. 5. DOWNSPOUT SHOULD HAVE A PVC SERIES 1000 WITH ALL SOLVENT JOINT FITTING
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 2" AS MINIMUM UNLESS OTHERWISE NOTED. ONLY SIZE AS INDICATED.
7. SIZE OF WATER SUPPLY PIPES 10 FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURE'S INSTRUCTIONS. 6. PIPE SEALANT , USE PVC SOLVENT CEMENT "NELTEX" OR ANY BRAND APPROVED.
8. ALL FIXTURES SHALL BE VENTION UNLESS OTHERWISE NOTED. 7. VALVES , USED "KITZ" , "CRANE" OR APPROVED EQUAL UP TO 50 MM, BRONZE ASIM
9. THE WORK THROUGHTOUT SHALL BE EXECUTE IN THE BEST AND MOST THOROUGH MANNER KNOWN TO THE TRADE B62, 1034 KPA CLASS THREADED END 65 MM UP , ALL IRON, BRONZE FITTED, 1034 KPA
AND SATISFACTION OF THE ARCHITECT AND OR ENGINEER. CLASS, FLANGED END.
10. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SHE AND COORDINATE WORKS WITH THE SEWER WATER METER USED "TOYO", "ASAH" MODEL OR MWSS APPROVED CRAIN S-ALL DRAINS
EFFLUENT DISPOSAL AND WATERLINE SERVICE CONNECTING POINT. SHALL BE SOLID BRASS.
11. RFER TO TECHNICAL SPECIFICATION FOR DETAILED MATERIALS AND EQUIPMENT POINT.