Prepared By: ToolPusher / HSE Advisor

Risk Assessment Register


Reviewed By: Drilling Superintendent

Approved By: HSE Manager Date : 1st November, 2015 Rev. No. 1

INITIAL RISK CONTROL MEASURES RESIDUAL RISK


Risk Number

HAZARDS Effect
Main Activity Sub Activity HAZARDS

Likelihood

Likelihood
Risk Level

Risk Level
( If the Hazard is Released )

Severity
Severity

Class

Class
Prevention & Mitigation Recovery Measures

1 Working in Working in  Oxygen  Personnel injury A 6P A H  Raise Permit to Work before starting the task. ERP, A 1P A1P L
confined Spaces confined  H2S  Respiratory disorders 6P  Ensure required isolation is done if required. MEDEVAC,
Spaces (Tanks/  Toxic Gases  Fatality  Conduct Gas test using calibrated multi gas detector Medical
Cellar)  Hot atmosphere  Fire / Explosion  Authorized gas tester to carry out the gas testing. facilities
 Slippery surfaces  Effecting Company  Conduct TBT before starting the job; identify the activity steps and hazards
 Moving objects reputation related to the task.
 Heavy object  Unconsciousness  Provision of buddy system.(standby man external to confined space)
 Inadequate lighting  Use air blowers and ventilation systems
 Provision of emergency extraction equipment, tripod and safety harness and
personnel H2S monitors
 All personnel to be aware of H2S Risk, emergency assembly points. Training for
all unit personnel.
 Regular communication with team in confined space
 Provision of H2S and LEL fixed detectors system.
 Regularly calibrate and check H2S and LEL sensors.
 Clean all fixed H2S and LEL sensors
 Contingency plan to be in place.
 Gas ignition hazards must be eliminated and "No Smoking" sign to be displayed
 Rescue from confined space equipment’s to be made ready.
 SCBA trainings to be provided for all personnel.
 Inspection & Maintenance schedule for fixed sensors and portable detectors
 Practice H2S, rescue
 from confined space, Fire and rescue Emergency Drills

Refer to the following documentations:

 Confined space procedure


 PTW Procedure
 H2S Procedure
 NDSC JSA 204
 NDSC JSA ‘CONFINED SPACE ENTRY”
 PDO Haz-ID # 24-53 H2S Monitor
 PDO Haz-ID 15 Battery

RA-R9-01-002-01