Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Retrofits Easily Into Existing Transformers: Qualitrol DGA 150/250/400

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

QUALITROL DGA 150/250/400 ®

Dissolved Gas Analysis

Retrofits easily into existing


transformers
• Enables real-time monitoring of hydrogen (H2), an early indicator of transformer
fault conditions
• Accurately measures hydrogen without interference from other fault gases
• Integrates with existing monitoring equipment and utilizes available transformer
installation points
• Integrated oil sampling valve with Luer fitting for easy sample collection

Product Summary
Description Hydrogen is generated under
most fault conditions that occur in power
transformers and is an early indication of larger
problems in the transformer’s lifecycle. Real
time monitoring of hydrogen provides an
economical method for maintaining the overall
health of the transformer.

Application Qualitrol’s DGA series enables online


monitoring of dissolved hydrogen in a variety of
transformers including conservator, air and
nitrogen blanketed models. Sensors can be
easily mounted directly in the insulating oil or in
the gas headspace, providing multiple mounting
options. Additionally, Qualitrol has integrated
hydrogen sensing capabilities in its latest Rapid
Pressure Rise Relief (RPRR) design (optional).
QUALITROL® DGA 150/250/400

Enables real-time monitoring of Early detection is crucial when dealing with a fault situation in a
hydrogen, an early indicator of transformer. Reduce diagnostic time through the use of online
transformer fault conditions monitoring. Track hydrogen trends without waiting for oil sampling data.

Accurately measures hydrogen without The DGA series uses a metal alloy that accurately responds to hydrogen,
interference from other fault gases even in the presence of other common fault gases (methane, ethane,
ethylene, and acetylene). The sensor materials are intrinsically selective
toward hydrogen, so while other gases are being generated from the
fault, they do not interfere with the hydrogen reading on the sensor.

Integrates with existing monitoring The DGA series mounts directly in the existing transformer valves and
equipment (including Qualitrol 507/509) is available in a 1.5-inch NPT union fitting or in a RPRR replacement
and utilizes existing transformer configuration. Units are pressure tested to ensure leak-free operation.
installation points

Integrated oil sampling valve with Luer Sampling is easy with a Luer style port located on the sensor housing.
fitting for easy sample collection The unique design offers a quick sample port that is accessible without
the use of additional tools yet easily seals to keep oil from escaping
the system. Hand tightening is all that is required, no more dealing with
cumbersome wrenches in the field.

Why Hydrogen?
Fault conditions in a transformer can have serious consequences due to the degradation of the dielectric and chemical
properties of the insulating oil. Hydrogen is an important gas to monitor in a transformer as it is the lightest gas
generated in abundance by most major fault situations including partial discharge (Corona), thermal faults, and arcing.

Online monitoring of hydrogen can save crucial time in diagnosing problems and preserving the health of
the transformer.

Gases Formed

• Hydrogen (H2)

• Hydrogen (H2)
• Methane (CH4)
• Ethane (C2H6)
• Ethylene (C2H4)

• Hydrogen (H2)
• Acetylene (C2H2)
• Methane (CH4)
• Ethane (C2H6)
• Ethylene (C2H4)
TECHNICAL SPECIFICATIONS

Mounting Options DGA 150 - Drain valve (Thread Mount) 1.5” - 11.5 NPT union fitting
DGA 250 - RPRR (Thread Mount) 2.5” - 8 NPT union fitting
DGA 400 - RPRR (Flange Mount) Four 0.5” diameter bolt slots equally
spaced on a 4” bolt circle

Range In oil with air headspace 50-5,000 PPM


In oil with inert headspace 25-5,000 PPM
In gas with air headspace 1000 PPM to 100,000 PPM
In gas with inert headspace 500 PPM to 100,000 PPM

Accuracy In oil ± 25 PPM or ± 20% of measurement


In gas ± 500 PPM or ± 20% of measurement
Resolution of In oil 1 PPM
Measurement In gas 20 PPM

Repeatability In oil ± 15 PPM or ± 10% of measurement


In gas ± 300 PPM or ± 10% of measurement
Recommended Lab
Annual
Data Correlation

Materials Housing Thermosetting powder coated aluminim


(ANSI #70 gray)
Sensor Probe Stainless steel
Sampling Valve Stainless steel
Valve Cap Nickel plated brass or Stainless steel
Mounting Flange/Spin Nut Aluminum
Seals Nitrile/Viton/Neoprene
Required Power
Supply 10-26 VDC @ 2 amps min

Output Parameters Remote analog 4-20 mA @ maximum of 500 Ohms


Pressure scale 0-30 PSIG
Data communication USB serial communications port locally,
RS485 (4 wire)

Immunity Dielectric isolation 2500 VAC for 60 seconds to ground


Surge withstand capability IEEE C37.90.1
Conducted/radiated emmissions IEC 61000-6-1 (EN61326-2-3)
Conducted/radiated radio
frequency immunity IEC 61000-6-2 (EN61326-2-3)
Safety IEC 61010-1

Environmental Oil temperature -20 ºC to +60 ºC


Operating temperature (ambient) -20 ºC to +55 ºC
Storage temperature -40 ºC to +85 ºC
Vibration 50/60 Hz @ 0.016” displacement
Weatherproof enclosure IP55

Cross Sensitivity
<1%
to other Gases

Email info@qualitrolcorp.com
www.qualitrolcorp.com
NOTICE
THIS DRAWING IS THE PROPERTY OF QualiTROL CORPORATION AND IS LOANED ONLY ON THE
MODEL
CONDITION THAT IT WILL BE USED TO FACILITATE THE PURPOSE FOR WHICH INTENDED AND NOT
BE REPRODUCED, COPIED OR OTHERWISE DISPOSED OF, AND IS NOT TO BE USED IN WHOLE NO. DGA-150
OR PART FOR FURNISHING INFORMATION RELATIVE TO THE MAKING OF DRAWINGS, PARTS
APPARATUS OR PARTS THEREOF, EXCEPT BY WRITTEN ORDER FROM QualiTROL CORPORATION.


NOTES:

QUALITROL DGA 150/250/400


1. MEETS QUALITROL PRODUCT PERFORMANCE
®
SPECIFICATION PPS-144. MODEL NO. SENSOR LOCATION
DGA-150-L-1 Transformer Oil
DGA-150-G-1 Gas Space

DGA 150- Drain Valve
10.4 [264]
.3 [7]

4.0 [100] 4.7 [119]

1.0 [25]

4.0 [102]
9.2 [235]
1.5" NPT NOTICE
THIS DRAWING IS THE PROPERTY OF QualiTROL CORPORATION AND IS LOANED ONLY ON THE
MODEL
UNION FITTING
CONDITION THAT IT WILL BE USED TO FACILITATE THE PURPOSE FOR WHICH INTENDED AND NOT
BE REPRODUCED, COPIED OR OTHERWISE DISPOSED OF, AND IS NOT TO BE USED IN WHOLE NO. DGA-250
OR PART FOR FURNISHING INFORMATION RELATIVE TO THE MAKING OF DRAWINGS, PARTS
APPARATUS OR PARTS THEREOF, EXCEPT BY WRITTEN ORDER FROM QualiTROL CORPORATION. CABLE RANGE:
.315-.433 [8.0-11.0]
NOTES:
1. MEETS QUALITROL PRODUCT PERFORMANCE MODEL NO. SENSOR LOCATION PRESSURE RANGE
SPECIFICATION PPS-144. DGA-250-L-1 Transformer Oil 0-30 Psig
DGA-250-G-1 Gas Space 0-30 Psig

DGA 250 - Rapid Pressure Rise Relay with DGA (thread mount) PH. (585) 586-1515
FAX (585) 377-0220
TITLE:
Hydrogen Sensor, 1.5 NPT Mtg.
1385 FAIRPORT ROAD
- 10-12-11 RELEASED 29568 MODEL
FAIRPORT, NY 14450
LET DATE ALTERATION C.N.
DIMENSIONS AND TOLERANCES IN NO. DGA-150
ACCORDANCE WITH ASME Y14.5M-1994 FORM 0-473 REV.D 10/22/02

10.7 [271]
3.2 [82]
.9 [22]
R2.6 [67]

2.3 [58]

7.4 [188]

2.5" NPT
UNION FITTING

9.7 [247]
CABLE RANGE:
.315-.433 [8.0-11.0]

1.5 [38]
NOTICE
THIS DRAWING IS THE PROPERTY OF QualiTROL CORPORATION AND IS LOANED ONLY ON THE
MODEL
CONDITION THAT IT WILL BE USED TO FACILITATE THE PURPOSE FOR WHICH INTENDED AND NOT
BE REPRODUCED, COPIED OR OTHERWISE DISPOSED OF, AND IS NOT TO BE USED IN WHOLE
OR PART FOR FURNISHING INFORMATION RELATIVE TO THE MAKING OF DRAWINGS, PARTS
NO. DGA-400
APPARATUS OR PARTS THEREOF, EXCEPT BY WRITTEN ORDER FROM QualiTROL CORPORATION.


NOTES: PH. (585) 586-1515 TITLE:

1. MEETS QUALITROL PRODUCT PERFORMANCE MODEL FAXNO. Hydrogen/Press.


SENSOR LOCATION
(585) 377-0220 Sensor,RANGE
PRESSURE 2.5NPT Mtg.
DGA 400- Rapid Pressure
2. DIMENSIONS ARE IN Rise Relay with
- SPECIFICATION PPS-144.
10-12-11 RELEASED
INCHES [MILLIMETERS].
29568 DGA (flange mount) DGA-400-L-1
1385 FAIRPORTTransformer
FAIRPORT, NY 14450
ROAD
MODEL Oil 0-30 Psig
DGA-250
0-30 Psig
FORM 0-473 REV.D 10/22/02 Gas Space
DIMENSIONS AND TOLERANCES IN NO.
LET DATE ALTERATION C.N. ACCORDANCE WITH ASME Y14.5M-1994 DGA-400-G-1

10.2 [258]
3.2 [82]
5.3 [133]
.4 [10]

3.5 [88] 3.6 [91]

7.4 [189]

4x .5 [13] ON 9.2 [234]


4.00 [102] B.C.
CABLE RANGE:
.315-.433 [8.0-11.0]

1.50 [38]

©2012 QUALITROL® Company LLC, an ISO 9001 system certified company. QUALITROL is a registeredPH. trademark
(585) 586-1515 and OTIWTI
FAX (585) 377-0220
TITLE:
is a trademark
Hydrogen/Pressure of QUALITROL
Sensor, ® Company LLC. All
Flange Mtg.
trademarks are properties of their respective companies, as noted herein. All rights reserved. Information1385
is FAIRPORT
subjectROAD to change without notice. AP-G34-01L-01E
- 10-12-11 RELEASED 29568 MODEL
FAIRPORT, NY 14450
LET DATE ALTERATION C.N.
DIMENSIONS AND TOLERANCES IN
ACCORDANCE WITH ASME Y14.5M-1994 FORM 0-473 REV.D 10/22/02
NO. DGA-400

Email: info@qualitrolcorp.com
www.qualitrolcorp.com

You might also like