Ultrasonic Oxygen Sensor Module Gasboard7500E
Ultrasonic Oxygen Sensor Module Gasboard7500E
Ultrasonic Oxygen Sensor Module Gasboard7500E
Gasboard7500E
www.gassensor.com.cn
Principle of measurement
Ultrasonic flow detection theory: When the ultrasonic wave transmits in the fluid, it will carry flow velocity under the
influence of fluid velocity. Fluid velocity can be measured by detecting the received ultrasonic signal to obtain the fluid
flow rate.
Ultrasound Receiving
wave sending
www.gassensor.com.cn
I/O definitions
Fixing
hole Fixing hole
Fixing hole
Inlet
Interface description
Linear output interface J1: Output voltage 0 ~ 5V, with the flow and O2 corresponding linear measurements. When the
voltage is 0 V DC, the corresponding output is 0, when the voltage is 5V, the corresponding output is full scale.
Serial port signal pin J2:TTL level (5V) can be connected with the external control panel TTL electrical level serial portal
and cannot be connected directly with the computer serial port. If it is connected with computer, then you need to
take special serial converter (TTL→RS232). With the serial port, the user can read real-time measurement results (gas
concentration and temperature) and do the maintenance.
www.gassensor.com.cn
Dimensions(unit: mm, tolerance±0.3mm)
www.gassensor.com.cn
Instructions
Do not smoke near the sensor and do not use naked flame.
The integrity of the pipeline must be ensured to avoid gas leakage due to
pipeline rupture. Leakage of gas containing toxic and explosive gases may
cause serious accidents.
The inlet pressure of the sensor must be within the required range of the
sensor to avoid pipeline loss or leakage caused by excessive pressure.
When venting, please connect the vent pipe to the outdoor atmosphere and
do not disperse it in the sampling device or in the room. Do not allow
moisture to penetrate the sensor, otherwise it may cause electric shock or
internal short circuit.
Under the condition without the permission of the manufacturer or
non-professional personal, do not disassemble the sensor, otherwise the
sensor manufacturers do not provide warranty or maintenance services for
the damage.
Please read the instructions carefully before using the sensor to avoid
personal injury or damage of the sensor.
www.gassensor.com.cn
Package
Note:Packing box is divided into three layers, and the layers are separated by pearl board.
Total number of sensor is 10*2*5*3=300
Note: The OEM version ultrasonic oxygen sensor needs to be confirmed with our product manager. Serial response mode
means the MCU controller need to send query command, then the sensor will response; serial blinding mode means the
sensor sends data in timing, then the MCU controller only needs to receive the measurement data.
www.gassensor.com.cn