3.Steam Valve
4. Temperature Controlled
Steam Barrier
Make sure that the
steam valve is open
If not adjust it. This
Corresponds
Temp range of 109 to
111°C.
5.Hydrogen peroxide HIGH Position
Conc (sterilisation):steam
pressure should be
between 1.7 and 1.8 bar.
Corresponds to 130 to
Check the hydrogen 131°C.
peroxide LINE Position: corresponds to Turn the selector to the
concentration the steam pressure in the line. OFF position.
LOW position(production):
the steam pressure should be
between 0.4 and 0.5 bar.
13.Gaskets Remove gaskets 14.Fit the sterile air pipe Fit the sterile air pipe as
from pipe fittings shown in the diagram
using the slot
indicated
Change gaskets if it
has worn out or too
dirty.
Disinfect gaskets
with
spitaderm(alcohol),
Alcodes(alcohol) or
Oxonia active(acid)
Replace in pipe
without rinsing
15.Fit the product Pipe 16.Inspect the cleaning Pipe
Inspect the cleaning pipe
Fit the product pipe and clean the flexible
as shown in the part.
diagram Store the cleaning pipe
in a clean place.
Operating Checklist
43.Filling Mode When the FILLING 44. Production When the packages start
symbol lights, the to be produced
level start to increase correctly, the
and is indicated PRODUCTION symbol
from LED S8 to LED Stops flashing but
S5 on TMCC2; the remains lit.
level indicator should The packages are
stabilise within seven directed to the final
or Eight packages. folder.
45.Package checks 46.Setting Values Pressure(Bars)
Check that all pressure gauges Cutting Pressure(8-9)
show the Jaw Pressure(9-9.6)
Correct settings during Cold water (0.30-0.45)
production. Hot water(0.3-0.45)
Sterile Air(0.30-0.35)
Air (6.5-7)
Air peroxide(3)
Calender Rollers(2.4)
Flap Sealing(1.5-2)
Temperatures(ºC)
Pick out the first two
Hot air element(165)
consecutive packages
Pre-sterilisation(270)
discharged from the
Water Bath (74)
final folder and
Water Bath (Pre-ste)(80)
perform package
LS sealed Tube(280)
checks on them.
LS sealing(380)
Air Superheat Pre(400)
Air Superheater(360)
Air Knife(125)
Steam(130)
Sterilising peroxide(70)
Flap sealing:
Top LH(420)
Top RH(420)
Bottom LH(400)
Bottom RH(400)
C. Cut the P.Material Open the aseptic D. Preparation for CIP Press program down
chamber door. Turn switch right
Cut the packaging Press program up
material. Close the Preparation for CIP
aseptic chamber door. symbol becomes fixed.
The VENTING
FINISHED symbol
remains lit.