30GQ
AIR-TO-WATER HEAT PUMP
NOMINAL COOLING CAPACITY:223.2-355KW
NOMINAL HEATING CAPACITY:232.6-349KW
AIR TO WATER HEAT EXCHANGE
FOR COOLING & HEATING
MULTIPLE COMPRESSORS
ENERGY EFFICIENT OPERATION
Electrical data(Unit)
Nominal voltage 400V - 3ph - 50Hz
model no kWmax. min. rated current max. fusable current max. instaneous current
25 223.3 64.1 238.4 67.2 252.3 70.7 274.4 76.5 294.2 83.0
30 209.3 68.6 223.3 71.6 236.0 75.7 257.0 81.6 276.7 88.3
080 35 196.5 72.6 209.3 76.1 222.1 80.2 240.7 86.7 258.1 93.7
40 182.6 76.8 195.4 80.6 205.8 84.9 224.4 91.7 239.5 99.3
45 169.8 97.5 180.3 85.0 190.7 89.6 207.0 96.8 222.1 105.0
25 279 77.7 298 81.4 315 85.5 343 92.4 367 100
30 262 83.0 279 86.6 295 91.21 321 98.4 347 106
100 35 245 87.8 262 91.9 278 96.8 301 104 323 113
40 228 92.7 244 97.2 257 102 280 110 300 119
45 213 97.5 226 102 238 108 259 116 278 126
25 335 96.0 358 101 379 106 412 115 442 125
30 314 103 335 107 355 113 386 122 415 132
120 35 295 109 314 114 334 120 362 130 387 141
40 274 115 293 121 309 127 337 138 359 149
45 255 121 271 128 286 134 310 145 334 158
unit model A B C D E F
30GQ - 080 1275 1000 993 778 1800 120
30GQ - 100 1400 1400 1133 728 2035 300
30GQ - 120 1400 1400 1133 728 2035 300
Service Space
120
30GQ - 080
30GQ - 100 4700 5 920 2000 1940 place a 10 to 20mm isoaltion pad under
30GQ - 120 5200 5 1020 2000 1940 the unit.
Typical wiring and piping
1 Main power supply 380VOL. 3 ph.4 lines(ref. electrical data for current size)
flow switch at outlet level straight pipe. 3 to 5 times of pipe diameter apart from the bending or valve, add 1°±
thermometer conn.
filter
notes:
1. Extra length is required for wiring from local power supply to control panel.
2. All wires and cables must be laid and positioned. and marked at ends by the installer.
LEGEND
C - Compressor Contactor FU - Fuse WR -Warning Relay
CB - Circuit Breaker, Comp. FPS - Outdoor Fan Pressure Switch PB1 - Start Push Button
CH - Crankcase Heater FS - Flow Switch PB2 - Stop Push Button
CHC - Cooler Heater Cable Aux. Relay GL - Green Lamp PT1 - Adjusting Knob, Cool
Comp - Compressor HPS - High Pressure Switch PT2 - Adjusting Knob, Heat
CSW1 - Check Switch IPF - Internal Protector, Fan Motor PT3 - Adjusting Knop, Temp, rise
CSW2 - Selector Switch LED - LED Display RR - Reversing Relay
CSW3 - Alarm Reset Switch LPS - Low Pressure Switch RVS - Reversing Valve Solenoid
DFR - Defrost Aux. Relay OFM - Outdoor Fan Relay S - Switch
DGT - Discharge Gas Temperature OL - Orange Lamp SR - Start Relay
A United Technologies Company