CC02A Data Sheet
CC02A Data Sheet
GENERAL MONITORS
Protection for life.
MODEL CC02A
Serial Communications Interface
Features Benefits
Description
The General Monitors CC02A Communications Card In the Zero Two Series chassis, the CC02A interfaces
facilitates serial communications between each with the Fault, Accept and Master Reset bus. Accept,
module in a General Monitors Zero Two Series Reset, LED Test and Card Test commands can be
System and an external host computer, allowing fast transmitted to an individual Zero Two Series module. In
access to operational and setup data registers. It Broadcast mode these commands are executed by all
supports a Burst Read feature, which returns all Zero Two Series modules simultaneously.
registers of a module in a single transmission.
The CC02A supports LED Test, operates from a 10VDC
The module acts as an intelligent bridge between the to 35VDC power supply and detects low supply
Zero Two Series System communications bus and the conditions. It has a Normally Energized Fault relay and a
host, implementing all necessary protocol Fault Unaccept open-collector output. Communications
conversions and error check routines. It maps user errors are flagged by their corresponding excep-
selected Zero Two Series System Serial module node tion codes in the MODBUS response.
addresses into the MODBUS node address space.
Applications
The CC02A presents an RS-485 based MODBUS • Refineries
RTU Slave interface to the host, while an additional
and independent RS-232 based MODBUS RTU Slave • Oil Fields
interface supports simultaneous communication with
a second or local host. The card can be programmed • Gas Fields
to act as Master or Slave on the Zero Two Series • Offshore Platforms
System communications bus.
• Fire and Gas Systems
A single CC02A is used as Master of a Zero Two
• Pipelines
Series System. An additional card configured as
Slave until required will increase fault tolerance. • Compressor and Pumping Stations
Systems
MODEL CC02A
System Specifications Mechanical Specifications