Carrier Config - Functions
Carrier Config - Functions
Carrier Config - Functions
SUPRA
Supra 4XX Supra 5XX Supra 7XX Supra 8XX Supra 9XX
Supra 4XX Supra 5XX OASIS 150 Supra 7XX OASIS 250 750sw 750sw Nordic Supra 8XX Supra 9XX OASIS 350
Nordic Nordic Nordic Nordic Nordic
MICRO configuration Description
Soft 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33 3.33
CNF 25 to CNF 32 : choix (ON/OFF) Not used OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
Micro parameters
FN0 Defrost setting : 1,5;3;6;12h 3h 3h 3h 3h 3h 6h 6h 6h 6h 6h 6h 6h 3h 3h 3h
FN1 ON/OFF Air On = high/Off=Norm OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air
FN2 Off time choice : 10;20;30;45;90mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn 20 mn
FN3 On time choice 4;7 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn
FN4 A/B PROBE choice A=Rem/B=Sup A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe A=Rem probe
FN5 F/C degree choix : F or C deg C deg C deg C deg C deg C deg C deg C deg C deg C deg C deg C deg C deg C deg C deg C
FN6 On=time start/ Off=temp start OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt
FN7 MOP choice : STD=0/-=-5/+=+4 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0 STD=0
FN8 2SET Set point adjustment 2CP Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans
FN9 3SET Set point adjustment 3CP Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans Sans
FN10 Start Op choice : on=Auto/off=Man On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP On = Auto OP
FN11 T range choix A=2, B=3, C=4 Dreg C C C C C C C C C C C C C C C C
Affichage display T Range choix : CODES OU ENGLISH English English English English English English English English English English English English English English English
Manuel glow override choice NORM / ADD Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow
Alarm reset CLR/RST CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
SUPRA MT
Description R90U R90 S750MT OASIS 250MT S850MT 950MT 950UMT
MICRO configuration
Soft 4,06 4,06 4,06 4,06 4,06 4,06 4,06
Micro parameters
FN0 Defrost setting : 1,5;3;6;12h 3H 3H 3H 3H 3H 3H 3H
FN1 ON/OFF Air On = high/Off=Norm OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air
FN2 Off time choice : 10;20;30;45;90mn 20 mn 20 mn 10 mn 10 mn 10 mn 10 mn 20 mn
FN3 On time choice 4;7 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn 7 mn
FN4 F/C degree choix : F or C Deg C Deg C Deg C Deg C Deg C Deg C Deg C
FN5 On=time start/ Off=temp start OFF=temp strt OFF=temp strt OFF=temp strt OFF=temp strt OFF=temp strt OFF=temp strt OFF=temp strt
FN6 MOP choice : STD=0/-=-5/+=+4 STD=0 STD=0 STD=0 STD=0 -5 STD=0 STD=0
FN7 Start Op choice : on=Auto/off=Man ON=Auto OP ON=Auto OP ON=Auto OP ON=Auto OP ON=Auto OP ON=Auto OP ON=Auto OP
FN8 T range choix A=2, B=3, C=4 Dreg C C C C C C C C
Affichage display CODES OR ENGLISH Display English English English English English English English
Manuel glow override choice NORM / ADD Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow
Alarm reset CLR/RST CLR CLR CLR CLR CLR CLR CLR
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
UNDERMOUNT
Supra 944U Supra 988U Supra 950U Supra 850U
MICRO configuration Description
Soft 3.33 3.33 3.33 3.33
CNF 25 to CNF 32 : choix (ON/OFF) OFF Not used OFF OFF OFF OFF
Micro parameters
FN0 Defrost setting : 1,5;3;6;12h 3h 3h 3h 6h
FN1 ON/OFF Air On = high/Off=Norm OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air
FN2 Off time choice : 10;20;30;45;90mn 20 mn 20 mn 20 mn 20 mn
FN3 On time choice 4;7 7 mn 7 mn 7 mn 7 mn
FN4 A/B PROBE choice A=Rem/B=Sup A=Rem probe A=Rem probe A=Rem probe A=Rem probe
FN5 F/C degree choix : F or C deg C deg C deg C deg C
FN6 On=time start/ Off=temp start OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt
FN7 MOP choice : STD=0/-=-5/+=+4 STD=0 STD=0 STD=0 STD=0
FN8 2SET Set point adjustment 2CP Sans Sans Sans Sans
FN9 3SET Set point adjustment 3CP Sans Sans Sans Sans
FN10 Start Op choice : on=Auto/off=Man On = Auto OP On = Auto OP On = Auto OP On = Auto OP
FN11 T range choix A=2, B=3, C=4 Dreg C C C C C
Affichage display T Range choix : CODES OU ENGLISH English English English English
Manuel glow override choice NORM / ADD Norm Glow Norm Glow Norm Glow Norm Glow
Alarm reset CLR/RST CLR CLR CLR CLR Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
MAXIMA
Maxima 1300 Maxima 1300 MT Maxima 1000 Maxima 1200 Maxima 1200 MT
MICRO configuration Description
Soft 3.33 3.33 3.33 3.33 3.33
DISCHARGE SENSOR CDT not used OFF OFF OFF OFF OFF OFF
CNF2 : choix (ON/OFF)
Indicates to the control if the DISCHARGE sensor is installed CDT used ON
HIGH SETPOINT 30°c (86°F) Max. Set point OFF OFF OFF OFF OFF OFF
CNF3 : choix (ON/OFF)
Indicates maximum Set Point allowed 32°c (90°F) Max. Set point ON
HEAT LOCKOUT OVERRIDE (Maxima MT Only) Overide not enabled OFF OFF OFF OFF
CNF4 : choix (ON/OFF)
Indicates to the control if the heat lockout is overridden Override Enabled ON ON ON
TRUCK UNIT Trailer unit OFF OFF OFF OFF OFF OFF
CNF6 : choix (ON/OFF)
Indicates to the control if the system has been selected for truck operation Truck unit ON
HIGH SPEED OVERRIDE Logic disabled OFF OFF OFF OFF OFF OFF
CNF7 : choix (ON/OFF)
Indicates to the control if the low speed coolant check logic is enabled Logic enabled ON
ELECTRIC FAN Belt driven fan OFF OFF OFF OFF OFF OFF
CNF8 : choix (ON/OFF)
Indicates to the control if electric fans are being used Electrical fan motors ON
OUT-OF-RANGE SHUT DOWN Out of range alarm only OFF OFF OFF OFF OFF OFF
CNF9 : choix (ON/OFF)
Indicates if main compartment out-of-range alarm shuts unit down after 45min. Out of range alarm and unit shut down ON
NOT ASSIGNED FOR TRAILER Not used OFF OFF OFF OFF OFF OFF
CNF10 : choix (ON/OFF)
Not used ON
FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION Functions normal OFF OFF OFF OFF OFF OFF
CNF11 : choix (ON/OFF)
Allow or lockout certain any changes of the functional parameter from keypad Functions locked ON
HP-62 MOP OPTION MOP parameter HP 62 option OFF OFF OFF OFF OFF OFF
CNF12 : choix (ON/OFF)
Use either normal or HP-62 MOP parameters Active ON
HEAT ONLY UNIT OPERATION OPTION Normal cool / heat / defrost operation OFF OFF OFF OFF OFF OFF
CNF13 : choix (ON/OFF)
Converts unit to a "Heat only" unit Heat only operation (Solara) ON
ULTRA FRESH II OPTION (Trailer unit) Logic disabled OFF OFF OFF OFF OFF OFF
CNF15 : choix (ON/OFF)
Indicates to the control if the Ultra Fresh II temperature control is enable Logic enabled ON
SHUNT DOWN WITH ALTERNATOR AUX ALARM Alt aux alarm only OFF
CNF16 : choix (ON/OFF)
Indicates if alternator AUX alarm shuts unit down in diesel mode Alt aux alarm & unit shut down ON ON ON ON ON ON
ULTRA FREEZE 1 OPERATION Disable Ultra freeze 1 OFF OFF OFF OFF OFF OFF
CNF 17 : choix (ON/OFF)
Indicates to the control if UFZ1 operation can run Enable Ultra freeze 1 ON
UNITS SELECTION LOCK OPTION Metric unit or english metric is not locked OFF
CNF 20 : choix (ON/OFF)
Indicates to the control if the units functional parameter is locked Unit selection is locked ON ON METRIC ON METRIC ON METRIC ON METRIC ON METRIC
FROZEN MODE PRIORITY LOGIC OPTION Frozen priority not active OFF OFF OFF OFF
CNF 21 : choix (ON/OFF)
Enables frozen priority logic Active ON ON ON
HOT GAS VALVES DRIVE Together OFF OFF OFF OFF OFF OFF
CNF 22 : choix (ON/OFF)
Indicates if the hot gas valves are driven together or separately Separately ON
SET POINT LOCK Set Point is not locked OFF OFF OFF OFF OFF OFF
CNF 23 : choix (ON/OFF)
Indicates if the change of the Set Point is locked Set Point is locked ON
CNF 25 to CNF 32 : choix (ON/OFF) Not used OFF OFF OFF OFF OFF OFF
Micro parameters
FN1 ON/OFF Air On = high/Off=Norm OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air OFF=Norm air
FN2 Off time choice : 10;20;30;45;90mn 10mn 10mn 10mn 10mn 10mn
FN4 A/B PROBE choice A=Rem/B=Sup A=Rem probe A=Rem probe A=Rem probe A=Rem probe B=Sup probe
FN6 On=time start/ Off=temp start OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt OFF=Temp strt
FN8 2SET Set point adjustment 2CP Sans Sans Sans Sans Sans
FN9 3SET Set point adjustment 3CP Sans Sans Sans Sans Sans
Affichage display T Range choix : CODES OU ENGLISH English English English English English
Manuel glow override choice NORM / ADD Norm Glow Norm Glow Norm Glow Norm Glow Norm Glow
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
L P SHUTDOWN DELAY 255 SECS FROZEN MIN OFF TIME 30 MIN 45 MIN
ENGINE TEMP, FOR S/S RESTART 0,0°C DISPLAY PRESSURES IN (LOCKED) BARS
8 HR ADDITIONAL DATA NO
Soft 04.11.0X
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
L P SHUTDOWN DELAY 255 SECS FROZEN MIN OFF TIME 30 MIN 45 MIN
HIGH SUC PRESS SHUTDOWN NO FROZEN OVERRIDE TEMP 4 DEG C 5 DEG C
REFRIGERATION SYS SHUTDOWN YES FROZEN MAX OFF TIME 0 MIN
ENG TEMP FOR S/S RESTART 0°C DISPLAY PRESSURES IN (LOCKED) BARS
ALTERNATOR CHECK SHUTDOWN NO ECO MODE NO YES
ENGINE OIL LEVEL SWITCH NO ENGINE HOURS OFF
DISPLAY TOTAL ENGINE HOURS YES C3 OUT OF RANGE ALARM (BR3 only) 4 DEG C
DISPLAY TOTAL STANDBY HOURS YES LOW SPEED STARTUP: STARTSTOP 0 MINUTES
DISPLAY TOTAL SWITCH ON HOURS YES LOW SPEED STARTUP: CONTINUOUS 0 MINUTES
DIESEL RESET VALUE 0 HOUR SILENT MODE NO
8 HR ADDITIONAL DATA NO
Soft 04.11.0X
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
TM1000 / TM800
TM 1000 / TM800
MICRO configuration Description Soft 3.33
GLOW TIME DI Engine long glow cycle DI
CNF1: choix(DI/TV)
Indicates to the control which engine is in the system and which glow time should be TV Engine short glow cycle TV TV
DISCHARGE SENSOR CDT not used OFF
CNF2 : choix (ON/OFF)
Indicates to the control if the DISCHARGE sensor is installed CDT used ON ON
HIGH SETPOINT 30°c (86°F) Max. Set point OFF OFF
CNF3 : choix (ON/OFF)
Indicates maximum Set Point allowed 32°c (90°F) Max. Set point ON
HEAT LOCKOUT OVERRIDE (Maxima MT Only) Heat lockout on -12°c (10°F) OFF OFF
CNF4 : choix (ON/OFF)
Indicates to the control if the heat lockout is overridden Heat lockout off ON
MOP MOP disabled OFF
CNF5 : choix (ON/OFF)
Indicates status of MOP control MOP enabled ON ON
TRUCK UNIT Trailer unit OFF OFF
CNF6 : choix (ON/OFF)
Indicates to the control if the system has been selected for truck operation Truck unit ON
HIGH SPEED OVERRIDE Logic disabled OFF OFF
CNF7 : choix (ON/OFF)
Indicates to the control if the low speed coolant check logic is enabled Logic enabled ON
ELECTRIC FAN Belt driven fan OFF OFF
CNF8 : choix (ON/OFF)
Indicates to the control if electric fans are being used Electrical fan motors ON
OUT-OF-RANGE SHUT DOWN Out of range alarm only OFF
CNF9 : choix (ON/OFF)
Indicates if main compartment out-of-range alarm shuts unit down after 45min. Out of range alarm and unit shut down ON ON
NOT ASSIGNED FOR TRAILER Not used OFF OFF
CNF10 : choix (ON/OFF)
Not used ON
FUNCTIONAL PARAMETERS (KEYPAD) LOCKOUT OPTION Functions normal OFF OFF
CNF11 : choix (ON/OFF)
Allow or lockout certain any changes of the functional parameter from keypad Functions locked ON
HP-62 MOP OPTION MOP parameter HP 62 option OFF
CNF12 : choix (ON/OFF)
Use either normal or HP-62 MOP parameters Active ON ON
HEAT ONLY UNIT OPERATION OPTION Normal cool / heat / defrost operation OFF OFF
CNF13 : choix (ON/OFF)
Converts unit to a "Heat only" unit Heat only operation (Solara) ON
INVERTABLE MULTI TEMP Not active OFF
CNF14 : choix (ON/OFF)
Indicates to the control if reversible multi temp control is active Reversible multi-temp active ON ON
ULTRA FRESH II OPTION (Trailer unit) Logic disabled OFF
CNF15 : choix (ON/OFF)
Indicates to the control if the Ultra Fresh II temperature control is enable Logic enabled ON ON
SHUNT DOWN WITH ALTERNATOR AUX ALARM Alt aux alarm only OFF
CNF16 : choix (ON/OFF)
Indicates if alternator AUX alarm shuts unit down in diesel mode Alt aux alarm & unit shut down ON ON
ULTRA FREEZE 1 OPERATION Disable Ultra freeze 1 OFF
CNF 17 : choix (ON/OFF)
Indicates to the control if UFZ1 operation can run Enable Ultra freeze 1 ON ON
LOW REFRIGERANT TEST Disable low refrigerrant test OFF
CNF 18 : choix (ON/OFF)
Indicates to the control if low refrigerant test is enable Enable low refrigerrant test ON ON
NOT ASSIGNED FOR TRAILER Not used OFF OFF
CNF 19 : choix (ON/OFF)
Not used ON
UNITS SELECTION LOCK OPTION Metric unit or english metric is not locked OFF OFF
CNF 20 : choix (ON/OFF)
Indicates to the control if the units functional parameter is locked Unit selection is locked ON
FROZEN MODE PRIORITY LOGIC OPTION Frozen priority not active OFF OFF
CNF 21 : choix (ON/OFF)
Enables frozen priority logic Active ON
HOT GAS VALVES DRIVE Together OFF OFF
CNF 22 : choix (ON/OFF)
Indicates if the hot gas valves are driven together or separately Separately ON
SET POINT LOCK Set Point is not locked OFF OFF
CNF 23 : choix (ON/OFF)
Indicates if the change of the Set Point is locked Set Point is locked ON
WT SENSOR ALARM WT sensor alarm only OFF
CNF 24 : choix (ON/OFF)
Indicates if WT sensor alarm shuts unit down WT sensor alarm & unit shut down ON ON
Micro parameters
FN0 Defrost setting : 1,5;3;6;12h 6H
FN1 ON/OFF Air On = high/Off=Norm Norm
FN2 Off time choice : 10;20;30;45;90mn 20
FN3 On time choice 4;7 4
FN4 A/B PROBE choice A=Rem/B=Sup Rem
FN5 F/C degree choix : F or C °C
FN6 On=time start/ Off=temp start time start
FN7 MOP choice : STD=0/-=-5/+=+4 MOP +
FN8 2SET Set point adjustment 2CP 32°F or O°c
FN9 3SET Set point adjustment 3CP 32°F or O°c
FN10 Start Op choice : on=Auto/off=Man Auto Op
FN11 T range choix A=2, B=3, C=4 Dreg C T range A
Affichage display T Range choix : CODES OU ENGLISH English
Manuel glow override choice NORM / ADD Norm
Alarm reset CLR/RST CLR
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
TR1000
Description TR1000
MICRO configuration
Soft 4,06
DI DI Engine long glow cycle
CNF1: choix(DI/TV)
TV TV Engine short glow cycle TV
OFF CDT not used
CNF2 : choix (ON/OFF)
ON CDT used ON
OFF 30°c (86°F) Max. Set point OFF
CNF3 : choix (ON/OFF)
ON 32°c (90°F) Max. Set point
OFF Heat lockout on -12°c (10°F) OFF
CNF4 : choix (ON/OFF)
ON Heat lockout off (truck units)
OFF MOP disabled
CNF5 : choix (ON/OFF)
ON MOP enabled ON
OFF Trailer unit OFF
CNF6 : choix (ON/OFF)
ON Truck unit
OFF Low speed start OFF
CNF7 : choix (ON/OFF)
ON High speed start
OFF Belt driven fan OFF
CNF8 : choix (ON/OFF)
ON Electrical fan motors
OFF Out of range alarm not shut down OFF (option)
CNF9 : choix (ON/OFF)
ON Out of range alarm and unit shut down
OFF No auto restart OFF
CNF10 : choix (ON/OFF)
ON Auto restart active
OFF Functions normal OFF (option)
CNF11 : choix (ON/OFF)
ON Functions locked
OFF MOP parameter HP 62 option OFF
CNF12 : choix (ON/OFF)
ON Active
OFF Cool / heat / defrost OFF
CNF13 : choix (ON/OFF)
ON Heat only (Solara)
OFF Not active OFF
CNF14 : choix (ON/OFF)
ON
OFF Not active OFF
CNF15 : choix (ON/OFF)
ON
OFF Alt aux alarm only
CNF16 : choix (ON/OFF)
ON Alt aux alarm & unit shut down ON
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
ULTRA
Ultra/Optima
Extra XT
Extra
MICRO configuration Description
Soft 3.33 3.33
Micro parameters
FN0 Defrost setting : 1,5;3;6;12h 6H 6H
FN1 ON/OFF Air On = high/Off=Norm OFF=Norm air OFF=Norm air
FN2 Off time choice : 10;20;30;45;90mn 10 mn 10 mn
FN3 On time choice 4;7 4 mn 4 mn
FN4 A/B PROBE choice A=Rem/B=Sup A=rem Probe A=rem Probe
FN5 F/C degree choix : F or C Deg F Deg F
FN6 On=time start/ Off=temp start OFF=temp strt OFF=temp strt
FN7 MOP choice : STD=0/-=-5/+=+4 STD=0 STD=0
FN8 2SET Set point adjustment 2CP sans sans
FN9 3SET Set point adjustment 3CP sans sans
FN10 Start Op choice : on=Auto/off=Man ON=Auto OP ON=Auto OP
FN11 T range choix A=2, B=3, C=4 Dreg C C C
Affichage display T Range choix : CODES OU ENGLISH English English
Manuel glow override choice NORM / ADD Norm Glow Norm Glow
Alarm reset CLR/RST CLR CLR
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
XARIOS
Xarios
Xarios 150/150- Xarios Xarios
150/150-
04/200/200- 350/350- 350/350- Xarios Xarios
XARIOS ROAD / 04/200/200- with Hot gas with Hot gas
MICRO CONFIGURATION 04/300/300-05 05/400/500-04 05/400/500-04 500/600/ road 500/600/ road
STAND-BY 04/300/300-05 heating option heating option
road / stand-by road / stand- road / stand- / stand-by 12v / stand-by 24v
road / stand-
12v by 12v by 24v
by 24v
DEFROST AUT AUT AUT AUT AUT AUT
BRIGHTNESS HIGH HIGH HIGH HIGH HIGH HIGH
UNIT (Ut) Ut °C Ut °C Ut °C Ut °C Ut °C Ut °C
BATTERY VOLTAGE (PS) PS 12 PS 24 PS 12 PS 24 PS 12 PS 24
NUMBER OF FAN (FAn) Fan1 Fan1 Fan2 Fan2 Fan3 Fan3
configuration
EVAPORATOR FAN CONTINUOUS RUN (F) Foff Foff Foff Foff Foff Foff
10mn 10mn
DEFROST
1h 1h
BRIGHTNESS HIGH HIGH
UNIT (Ut) Ut °C Ut °C
configurations
XARIOS MT
xarios 350/350-05 Xarios 500 MT Xarios 600 MT Xarios 600 MT
ROAD / ROAD xarios 350/350-05 MT Xarios 500 MT Road /
MICRO CONFIGURATION MT Road / road Road / Road stand- Road / Road stand- Road / Road stand-
STANDBY Road / road stand-by 12v Road stand-by 12v
stand-by 24v by 24v by 12V by 24V
DEFROST operating mode selection Simu Simu Simu Simu Simu Simu
DEFROST interval 3H 3H 3H 3H 3H 3H
BRIGHTNESS HIGH HIGH HIGH HIGH HIGH HIGH
UNIT (Ut) Ut °C Ut °C Ut °C Ut °C Ut °C Ut °C
BATTERY VOLTAGE (PS) PS 12 PS 24 PS 12 PS 24 PS 12 PS 24
** to be selected ** to be ** to be ** to be ** to be ** to be
configurations
COOLING operating mode selection Auto Auto Auto Auto Auto Auto
parameters
EVAPORATOR FAN CONTINUOUS RUN (F) Foff Foff Foff Foff Foff Foff
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
NEOS
Road Road/Standby
MICRO CONFIGURATION
DEFROST AUT AUT
SET POINT 0°C 0°C
UNITY (Ut) Ut °C Ut °C
BATTERY VOLTAGE (PS) PS 12 PS 12
NUMBER OF STAGES (ET) 3ET 3ET
DOOR SWITCH (d) doff doff
LOW SET POINT - 29 °C - 29 °C
TEMPERATURE DIFFERENCIAL (dif) dif2 dif2
EVAPORATOR FAN CONTINUOUS RUN (F) Foff Foff
Update 06/07/2009
MICRO CONFIGURATIONS AND FUNCTIONS
VIENTO
VIENTO VIENTO
VIENTO VIENTO VIENTO VIENTO
VIENTO ROAD VIENTO 350 CH VIENTO 350 VIENTO 350 200 LA / 200 LA /
MICRO CONFIGURATION 300 CH 300 LA / 300 LA / 200 CH
ONLY R134A LA / HA R134A LA / HA R404A HA HA
R134A HA R134A HA R404A R134A
R134A R404A
Soft version SOFTWARE 4,0 4,0 4,0 4,0 4,0 4,0 4,0 4,0 4,0
DEFROST NATURAL 1H - 15' 1H - 15' NATURAL 1H - 15' 1H - 15' NATURAL 1H - 15' 1H - 15'
BRIGHTNESS - - - - - - - - -
- - - - - - -
UNIT (Ut) Ut °C Ut °C Ut °C Ut °C Ut °C Ut °C Ut °C Ut °C Ut °C
BATTERY VOLTAGE (PS) - - - - - - - - -
configuration
LOW SET POINT 0°C 0°C 0°C 0°C 0°C 0°C 0°C 0°C 0°C
HIGH SET POINT + 30 °C + 30 °C + 30 °C + 30 °C + 30 °C + 30 °C + 30 °C + 30 °C + 30 °C
TEMPERATURE DIFFERENCIAL (dif) dif2 dif2 dif2 dif2 dif2 dif2 dif2 dif2 dif2
EVAPORATOR FAN CONTINUOUS RUN (F) Foff Foff Foff Foff Foff Foff Foff Foff Foff
Update 06/07/2009