Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Low Voltage Distribution Products: Price List

Download as pdf or txt
Download as pdf or txt
You are on page 1of 80

Price List

Low Voltage
Distribution Products
With effect from March 12, 2018

schneider-electric.co.in
Price List Contents

Smart Panels
 Introduction to Smart Panels.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Moulded Case Circuit Breakers:
Compact NSXm:
 Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
 MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . 11
 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Compact NSX:
 Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
 MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . 20
 MCCBs for Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
 MCCBs for DC Network Protection . . . . . . . . . . . . . . . . . . . . . . . . 26
 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
 Automatic Source Changeover System. . . . . . . . . . . . . . . . . . . . . 30
Compact NS:
 Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
 MCCBs 800A onwards Manual Fixed . . . . . . . . . . . . . . . . . . . . . . 33
 MCCBs 800A onwards Electrical Fixed. . . . . . . . . . . . . . . . . . . . . 35
 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
EasyPact CVS:
 Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
 MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . 39
 MCCBs for Distribution Network and Motor Protection. . . . . . . . . 41
 Easy-Pact CVS Switch Disconnector Version . . . . . . . . . . . . . . . . 42
 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
 Type 2 Co-ordination table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
EasyPact EZC:
 Range Overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
 MCCBs for Distribution Network.. . . . . . . . . . . . . . . . . . . . . . . . . . 47
 Accessories and EasyPact Range Busbar systems. . . . . . . . . . . . ..49
EasyPact NKS
 MCCBs for AC Distribution Network . . . . . . . . . . . . . . . . . . . . . . . 50
 Simpact NKS DC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Ground Fault / Earth Leakage Protection
 Unique Modular Ground Fault Protection . . . . . . . . . . . . . . . . . . . 52
 Earth Leakage Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
 Vigirex - Earth Leakage Protection Relay . . . . . . . . . . . . . . . . . . . 54
Compact- INS & INV Switch Disconnectors . . . . . . . . . . . . . . . . . . . . 55
Switch Disonnector fuse units - range overview. . . . . . . . . . . . . . . . . 56
Fupact Switch Disconnector and Accessories. . . . . . . . . . . . . . . . . . 57
Fupact -Type 2 Co-ordination table. . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Air Circuit Breakers:
Masterpact NT/NW:
 Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
 Micrologic Trip system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
 ATS Kit range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
EasyPact MVS:
 Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
 ET/ETA/ETV Trip System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
 Draw-out type Circuit breakers and Switch Disconnectors. . . . . . 68
 Fixed type Circuit breakers and Switch Disconnectors. . . . . . . . . 70
 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Price List Contents

EasyPact SPS:
 Range Overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
 Draw-out type Circuit breakers and Switch disconnector. . . . . . . 74
 Fixed type Circuit breaker and Switch disconnector. . . . . . . . . . . 75
 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Panel C-42 // 10:30 a.m.

Please check on Breaker 5.


Higher load than normal.

Panel C-42 // 10:30 a.m.

Save that energy, Elena.


I believe in you.

Now, your electrical panel is your


partner in energy efficiency.

Give it a voice with EcoStruxure™


Power from Schneider Electric

schneider-electric.com/smart-panels

schneider-electric.co.in 5
Smart Panels
Make your electrical installations smart, simple & reliable

1 Protect
Electrical protection is at the core of
Smart Panels
4 Act
Reliable and high-performance technology
is present in every breaker and every • Data driven energy efficiency actions
residual current device. • Real time monitoring and control
• Access to energy and site information
2 Measure through online services
Keeping a close eye on energy flows
The switchboard plays a key role in capturing
building related data, by gathering the
protection and metering component’s data.

3 Connect
Give a voice to the panel
Ethernet network data transmission is now
part of the intrinsic design of protection and
metering devices

Ethernet Connected Switchboards


Energy Management
• Real time energy monitoring without any software
• Historical data viewing
Asset Management
• Breaker health monitoring (Contact wear information & No of operations)
• Remote/Local controlling of breakers
• Remote inspection of panels (temperature, door status etc)
Electrical Network Management
• Supply continuity monitoring
• Email notification of events (Overload, Short Circuit, Earth Fault,
Temperature overrun etc)
• Tracking changes in Protection Settings
• Real time trend monitoring
• Trip history with time stamping

Ready to plug’in to Building and Energy management softwares


schneider-electric.co.in 6
Smart Panels
Smart Panels
Simple
Simple energy
energy && maintenance
maintenance management
managementwithout
withoutexpensive
expensive
software
software licenses
licenses

Switchboard display

Quick view of digitally Detailed status of View all electrical


connected devices all devices parameters

Powerview webpages Facility Hero

Comprehensive views of energy Smart Digital log book


consumption (dashboards: allowing multiuser
histograms, graphcharts), enabling community to share
energy efficiency actions maintenance tasks &
information

Notifications

Advanced integrated softwares for comprehensive


Energy & Building management
StructureWare Building Operation
with Power Manager
Direct connection
to Power Manager

Benefits of Power Manager Benefits of Smart Panels


Ensure electrical network health Easy to Install
• Monitor electrical equipment and key assets • Less cables
• Improve response to power related issues • Pre-Engineered system

Increase power quality awarness Easy to Commision


• Power factor, harmonics and voltage • Direct IP connectivity
• Detectfaults and diagnose key electrical problems • TVD Solution

Increase power quality awarness Deeper visibility into infrastructure


• Track energy consumption and allocate costs • Feeder monitoring
• Achive energy conservation objectives • Breaker maintenance and testing

schneider-electric.co.in 7
schneider-electric.co.in 8
schneider-electric.co.in 9
Compact NSXm circuit breakers:
Optimized for your needs
The Compact NSXm range of circuit breakers and switch disconnectors
is a newcomer in the Compact NSX family. It is one of the smallest on the
market with innovative features. Built on the design of roto-active
breaking technology, we have made it as robust as Compact NSX
products.

Compact NSXm main features and innovations


• Rated Current ,In (A) – 16, 25, 32, 40, 50, 63, 80, 100, 125, 160
• Breaking capacity (kA) at 415V – 16, 25, 36, 50, 70
• Thermal magnetic trip unit integrated
• Built-in DIN rail and plate mount
• Auxiliaries externally visible
• EverLink™ connectors

EverLink™ patented technology


The Compact NSXm features a new cable connection method with patented
creep-compensating technology built directly into the terminal - EverLink™:
• With EverLink™ connectors, save space and time during panel assembly.
More than 35
• Bare cable connections are as safe as compression lug ones.
patents have
been registered
for this new
Compact NSXm
offer.

For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care

schneider-electric.co.in 10
Compact NSXm Moulded Case Circuit Breakers

With Thermal Magnetic Trip Unit


(TMD) and Compression Lug connectors

• Ics = 100% Icu as per IEC 60947-2


• Adjustable thermal setting 0.7 – 1 x In
• Fixed magnetic settings
LUG CONNECTION • Single frame size upto 160A
• 5 breaking capacities from 16kA to 70kA
• With compression lug connectors
n
io
l at • All the circuit breakers have a transparent lead-sealable cover
su
Re
w
Lo

Breaking Capacity Icu


Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]
as per IEC 60947-2
16A LV426150 6570 LV426160 9390
25A LV426151 6570 LV426161 9390
32A LV426152 6570 LV426162 9390
40A LV426153 6570 LV426163 9390
50A LV426154 6570 LV426164 9390
16kA
63A LV426155 6570 LV426165 9390
80A LV426156 6570 LV426166 9390
100A LV426157 6570 LV426167 9390
125A LV426158 11920 LV426168 14670
160A LV426159 13010 LV426169 16060
16A LV426250 7140 LV426260 10310
25A LV426251 7140 LV426261 10310
32A LV426252 7140 LV426262 10310
40A LV426253 7140 LV426263 10310
50A LV426254 7140 LV426264 10310
25kA
63A LV426255 7140 LV426265 10310
80A LV426256 7230 LV426266 10310
100A LV426257 7230 LV426267 10310
125A LV426258 13080 LV426268 16040
160A LV426259 14440 LV426269 17990
16A LV426350 9090 LV426360 11640
25A LV426351 9090 LV426361 11640
32A LV426352 9090 LV426362 11640
40A LV426353 9090 LV426363 11640
50A LV426354 9090 LV426364 11640
36kA
63A LV426355 9090 LV426365 11640
80A LV426356 9090 LV426366 11640
100A LV426357 9090 LV426367 11640
125A LV426358 13690 LV426368 17420
160A LV426359 15140 LV426369 19290
16A LV426450 11770 LV426460 14430
25A LV426451 11770 LV426461 14430
32A LV426452 11770 LV426462 14430
40A LV426453 11770 LV426463 14430
50A LV426454 11770 LV426464 14430
50kA
63A LV426455 11770 LV426465 14430
80A LV426456 11770 LV426466 14900
100A LV426457 11770 LV426467 14900
125A LV426458 16000 LV426468 18990
160A LV426459 17190 LV426469 20580
16A LV426550 13820 LV426560 17310
25A LV426551 13820 LV426561 17310
32A LV426552 13820 LV426562 17310
40A LV426553 13820 LV426563 17310
50A LV426554 13820 LV426564 17310
70kA
63A LV426555 13820 LV426565 17310
80A LV426556 13820 LV426566 17310
100A LV426557 13820 LV426567 17310
125A LV426558 25750 LV426568 27510
160A LV426559 26000 LV426569 27780

For details on stockable and non stockable status, technical parameter, please contact Customer Care Centre W.E.F. March 12, 2018

schneider-electric.co.in 11
Compact NSXm Moulded Case Circuit Breakers

With Thermal Magnetic Trip Unit


(TMD) and EverLink™ connectors

• Ics = 100% Icu as per IEC 60947-2


• Adjustable thermal setting 0.7 – 1 x In
EVERLINK • Fixed magnetic settings
• Single frame size upto 160A
n • 5 breaking capacities from 16kA to 70kA
io
l at • With Patented EverLink™ connectors
su
Re • All the circuit breakers have a transparent lead-sealable cover
w
Lo

Breaking Capacity Icu


Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]
as per IEC 60947-2
16A LV426100 6570 LV426110 9390
25A LV426101 6570 LV426111 9390
32A LV426102 6570 LV426112 9390
40A LV426103 6570 LV426113 9390
50A LV426104 6570 LV426114 9390
16kA
63A LV426105 6570 LV426115 9390
80A LV426106 6570 LV426116 9390
100A LV426107 6570 LV426117 9390
125A LV426108 11920 LV426118 14670
160A LV426109 13010 LV426119 16060
16A LV426200 7140 LV426210 10310
25A LV426201 7140 LV426211 10310
32A LV426202 7140 LV426212 10310
40A LV426203 7140 LV426213 10310
50A LV426204 7140 LV426214 10310
25kA
63A LV426205 7140 LV426215 10310
80A LV426206 7230 LV426216 10310
100A LV426207 7230 LV426217 10310
125A LV426208 13080 LV426218 16040
160A LV426209 14440 LV426219 17990
16A LV426300 9090 LV426310 11640
25A LV426301 9090 LV426311 11640
32A LV426302 9090 LV426312 11640
40A LV426303 9090 LV426313 11640
50A LV426304 9090 LV426314 11640
36kA
63A LV426305 9090 LV426315 11640
80A LV426306 9090 LV426316 11640
100A LV426307 9090 LV426317 11640
125A LV426308 13690 LV426318 17420
160A LV426309 15140 LV426319 19290
16A LV426400 11770 LV426410 14430
25A LV426401 11770 LV426411 14430
32A LV426402 11770 LV426412 14430
40A LV426403 11770 LV426413 14430
50A LV426404 11770 LV426414 14430
50kA
63A LV426405 11770 LV426415 14430
80A LV426406 11770 LV426416 14900
100A LV426407 11770 LV426417 14900
125A LV426408 16000 LV426418 18990
160A LV426409 17190 LV426419 20580
16A LV426500 13820 LV426510 17310
25A LV426501 13820 LV426511 17310
32A LV426502 13820 LV426512 17310
40A LV426503 13820 LV426513 17310
50A LV426504 13820 LV426514 17310
70kA
63A LV426505 13820 LV426515 17310
80A LV426506 13820 LV426516 17310
100A LV426507 13820 LV426517 17310
125A LV426508 25750 LV426518 27510
160A LV426509 26000 LV426519 27780

For Details on stockable and non-stockable status, technical parameter, please Contact Customer Care Centre
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 12
Compact NSXm Switch Disconnector

• Suitability for isolation as defined by standard IEC 60947-3


• Self protected by their high-set magnetic release
• Single frame size upto 160A

Compact NSXm NA switch-disconnector


With Compression Lug connectors
Three Pole Four Pole
Rated Current Unit LP [`] Unit LP [`]
Reference Reference
50A LV426650 7970 LV426660 11780
100A LV426651 7970 LV426661 11780
160A LV426652 16310 LV426662 21750

Compact NSXm NA switch-disconnector


With EverLink™ connectors
Three Pole Four Pole
Rated Current Unit LP [`] Unit LP [`]
Reference Reference
50A LV426600 8170 LV426610 12070
100A LV426601 8170 LV426611 12070
160A LV426602 16710 LV426612 22280

Accessories for Compact NSXm


16A to 160A

NSXm Accessories
Auxiliary contacts (changeover) Voltage Releases
Description Reference Unit LP [`] Shunt Release Under Voltage
Description Unit LP [`] Unit LP [`]
Standard OF or SD LV426950 770 Reference Reference
AC
Rotary Handles 24 V 50/60 Hz LV426841 LV426801
Description Reference Unit LP [`] 48 V 50/60 Hz LV426842 LV426802
Direct rotary handle 110-130 V 50/60 Hz LV426843 1890 LV426803 2460
Standard black handle LV426930 1060 220-240 V 50/60 Hz LV426844 LV426804
Extended rotary handle 380-415 V 50 Hz LV426846 LV426806
Standard extended rotary DC
LV426932 1570
black handle 24 V LV426841 LV426801
Side rotary handle 48 V LV426842 LV426802
1890 2460
Standard side rotary black 125 V LV426843 LV426803
LV426935 2690
handle 250 V LV426844 LV426815

Rotary Handles
Description Reference Unit LP [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV426940 580
Spreaders (Set of 4) 4P LV426941 590

Please contact Customer Care Center for Stockable and Non stockable status of references.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 13
schneider-electric.co.in 14
Ethernet Ready Next Generation Circuit Breakers

Compact NSX
LV circuit breakers from 16A to 630A

Energy Increased Safety and


measurement energy protection
and control availability
schneider-electric.co.in 15
Compact NSX

Ethernet ready Next-generation circuit breakers

• Ethernet based monitoring, control, alarm notification for energy, asset and network
management
• Built-in energy metering with combined accuracy class of 2% for precise
measurement
• Intelligent / Enhanced discrimination for continuity of service
• Patented reflex tripping, independent of other protection functions, ensures ultra fast
tripping in the event of very high short circuit
• Encapsulated roto-active double break contact system limits fault current for extended
system life
• Best in class electrical life (30k cycles for NSX 100 @ 440 V) reduces operational expenditure
• High performance => Ics = Icu = 100kA @ 690V AC

Range Details:
• 16A to 630A in two frames sizes
• Breaking capacity up to 200kA @ 415V
• TMD and Microprocessor based trip unit
• Available in Fixed, Plug-in and Draw out type versions

schneider-electric.co.in 16
Type of Trip Units

Micrologic Trip Units


(ASIC-Application Specific Integrated Circuit)

Protection Cases Measurement Application

1I 2 NSX100-250 A Ammeter --- Distribution


2 LS0I 3 NSX400-630 E Energy Meter G Generator
5 LSI AB Subsciber
6 LSIG M Motor
Z 16Hz 2/3

Example
Micrologic 1.3 M I 400 or 630 A Motor
Micrologic 2.2 G LS0I 100, 160 or 250 A Generator
Micrologic 2.3 LS0I 400 or 630 A Distribution
Micrologic 2.3 M LS0I 400 or 630 A Motor
Micrologic 5.2 A LSI 100, 160 or 250 A Ammeter Distribution
Micrologic 5.3 E LSI 400 or 630 A Energy Distribution
Micrologic 6.3 E-M LSIG 400 or 630 A Energy Motor

Thermal Magnetic Trip Unit


• Available from 16A - 250A
• Overload Setting (Ir) 0.7 - 1 x In
• Short Circuit Setting (Im)
• Fixed upto 160A
• Adjustable 5 - 10 x Ir (for 200A - 250A)

I - Instantaneous
S0 - Short Time with Fixed Time Delay
S - Short Time with Adjustable Time Delay
G - Ground Fault

schneider-electric.co.in 17
Compact NSX PV for Photovoltaic applications

• Circuit Breakers and Switch Disconnectors


• A complete DC offer for Solar Applications from 80 to
1500A.
• 80A to 500A MCCB with TMD type trip unit
• 80A to 1500A Switch disconnector

Ensuring safe and efficient operation of your


Photovoltaic installation.
With heat sink supplied as standard, MCCB rating is optimized,
avoiding the need to oversize protection components and saving
space in the enclosure.

Connection and insulation accessories supplied as


standard with Compact NSX PV MCCB are:
• Connection plate with heat sink
• Upstream and downstream terminal shields

schneider-electric.co.in 18
PowerPact

Multistandard offer for OEM applications


Be compliant around the world
Range - 16A to 600A in Two frames sizes

• Compliance to UL489, IEC60947, CCC & CSA standards.


• Breaking Capacity up to 100kA
• Voltage rating up to 600V
• Isolation with Positive Break Indication
• Fixed, Plug-in and Draw out type
• TMD and Microprocessor based trip unit
• Built-in energy metering (2% accuracy class)
• Smart Integration over Communication Network

1
Trust US...
> to supply worldwide availabilty stop
> to apply tested and validated solutions
> to comply to international standards shop

schneider-electric.co.in 19
Compact NSX Moulded Case Circuit Breakers for
Distribution Network

With Thermal Magnetic Trip Unit (TMD)


• Ics = 100% Icu as per IEC 60947-2
• Adjustable thermal setting 0.7 - 1 x In
• Adjustable magnetic setting 5 – 10 x Ir **
• Transparent cover for trip unit as standard
• Breaking Capacity enhancement upto 150kA with a higher capacity
upstream (Cascading)
• Exceptional current limiting < 6 x 105 A2S

Breaking Capacity Icu


Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]
as per IEC 60947-2
16A LV429557 8590 LV429567 12340
25A LV429556  8590 LV429566 12340
32A LV429555  8590 LV429565 12340
40A LV429554  8590 LV429564 12340
50A LV429553 8590 LV429563 12340
63A LV429552  8590 LV429562  12340
25kA
80A LV429551  8590 LV429561 12340
100A LV429550  8590 LV429560  12340
125A LV430311  15120 LV430321  18480
160A LV430310  15970 LV430320  19550
200A LV431111 23460 LV431121  28230
250A LV431110  23690 LV431120  28510
16A LV429637  10470 LV429647 13250
25A LV429636  10470 LV429646 13250
32A LV429635  10470 LV429645  13250
40A LV429634  10470 LV429644 13250
50A LV429633 10470 LV429643 13250
63A LV429632  10470 LV429642  13250
36kA
80A LV429631  10470 LV429641 13250
100A LV429630  10470 LV429640  13250
125A LV430631  15640 LV430641  19660
160A LV430630  16420 LV430640  20620
200A LV431631  24000 LV431641  29590
250A LV431630  24230 LV431640  30480
16A LV429847 12100 LV429857 15320
25A LV429846 12100 LV429856 15320
32A LV429845  12100 LV429855 15320
40A LV429844  12100 LV429854 15320
50A LV429843 12100 LV429853 15320
63A LV429842  12100 LV429852 15320
50kA
80A LV429841  12100 LV429851 15320
100A LV429840  12100 LV429850 15320
125A LV430841  18460 LV430851 21330
160A LV430840  19200 LV430850 21970
200A LV431831  25620 LV431841 31300
250A LV431830  25860 LV431840 32240
16A LV429677 15840 LV429687 20620
25A LV429676 15840 LV429686 20620
32A LV429675 15840 LV429685 20620
40A LV429674 15840 LV429684 20620
50A LV429673 15840 LV429683 20620
63A LV429672  15840 LV429682 20620
70kA
80A LV429671 15840 LV429681 20620
100A LV429670  15840 LV429680 20620
125A LV430671 29480 LV430681 31630
160A LV430670  29780 LV430680 31940
200A LV431671 33720 LV431681 43380
250A LV431670  34050 LV431680 43810

Note:
• ** applicable for NSX 200A & 250A
• For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 20
Compact NSX Moulded Case Circuit Breakers for
Distribution Network

With Micrologic 2 (μP -ASIC based)


• Protection type LS0IN
• Ics = 100% Icu as per IEC 60947-2
• Adjustable overload from 0.40 - 1 x In
• Adjustable short circuit from 1.5 - 10 x Ir
• Innovative front indication LED`s (Ready, Overload pre-alarm & Overload)
• Two frame sizes up to 630A
• Breaking Capacity enhancement upto 150kA with a higher capacity
upstream (Cascading)
• Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB

Breaking Capacity Icu


Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]
as per IEC 60947-2
40A LV429777  15190 LV429787 19540
100A LV429775  15190 LV429785  19540
25kA
160A LV430745  19400 LV430750  24750
250A LV431140  25490 LV431150  32700
40A LV429772 15440 LV429782 19640
100A LV429770  15440 LV429780  19640
160A LV430770  19740 LV430780  27340
36kA
250A LV431770  26820 LV431780  37180
400A LV432676  37000 LV432677  42250
630A LV432876  39120 LV432877  50720
40A LV429797 18430 LV429807 25240
100A LV429795  18430 LV429805  26000
160A LV430775  23360 LV430785 30250
50kA
250A LV431870  30520 LV431875  40020
400A LV432693  38730 LV432694  50250
630A LV432893  40100 LV432894  53130
40A LV429792 23730 LV429802 29850
100A LV429790 24090 LV429800 29850
160A LV430790 31590 LV430800 40320
70kA
250A LV431790 35230 LV431800 51080
400A LV432695  44020 LV432696 57800
630A LV432895  45110 LV432896 70170

Note: For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.

With Micrologic 2 (μP -ASIC based ) / TMD / MA+ shunt +GFP


• Protection type LS0IGN
• Ics = 100% Icu as per IEC 60947-2
• Fault indication for GF (LED type) meant for human safety
• Adjustable overload from 0.36 - 1 x In
• Adjustable short circuit from 1.5 - 10 x Ir
• Adjustable earth fault sensitivity selection 10 to 60%
• Innovative front indication LED’s (Ready, Overload pre-alarm & Overload)
• Two frame sizes up to 630A
• Suitable for 3P3W & 3P4W electrical distribution network
• Breaking Capacity enhancement upto 150kA with a higher capacity
upstream (Cascading)
• Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB

Relay Module 3 Ph + 3W 3 Ph + 4W
MCCB Frame Unit LP [`] Unit LP [`]
rated current Reference Reference
CVS/NSX100 32, 40, 50, 63, 80, 100 GFP11CT13P  4930 GFP11CT14P  5400
CVS/NSX 160 / 250 125, 160, 200, 250 GFP12CT23P  5610 GFP12CT24P  6330
CVS/NSX 400 / 630 400, 630 GFP13CT33P  8470 GFP13CT34P  9250
CVS 800 800 GFP14CT43P  10440 GFP14CT44P  11690

Note: Kindly order NSX/CVS MCCB +GFP+. Shunt trip coil.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 21
Compact NSX Moulded Case Circuit Breakers for
Distribution Network

With Micrologic 6A (Embedded current metering and communication capable)

• Protection type LSIGN


• Ics = 100% Icu as per IEC 60947-2
• Current measurements (Phase & neutral, Average, Highest of phases, Ground
fault current, Maximeter / Minimeter, Current unbalance between phases)
• Adjustable overload from Ir 0.36 to 1 x In and tr = 0.5 - 16 s
• Adjustable short circuit from Isd 1.5 - 10 x Ir and tsd I2tON/OFF 0.1 - 0.4s
• Adjustable earth fault 0.4 - 1 x In (for In=40A) & 0.2 - 1 x In (for In>40A) and tg
I2tON/OFF 0.1 - 0.4s
• Instantaneous protection Ii 1.5 x In - 15 x In (40 - 160A), 12 x In (250 - 400A)
and 11 x In (630A)
• Innovative front indication LED`s (Ready, Overload pre-alarm & Overload)
• Fault distinction on the display of trip unit (type of fault, interrupted fault current
and faulty phase)
• Zone Selective Interlocking (ZSI) as standard
• Breaking Capacity enhancement upto 150kA with a higher capacity upstream
(Cascading)
• External Neutral CT required for highly un-balanced TP-N system has to be
ordered at extra price
• Adjustable neutral protection - N, N/2,OFF and oversized neutral (standard
feature) for 4 Pole MCCB.

Breaking Capacity Icu Three Pole Unit LP Four Pole Unit LP


Rated Current
as per IEC 60947-2” Reference [`] Reference [`]
40A LV429014X62A40 34030 LV429015X62A40 38090
100A LV429014X62A100 34030 LV429015X62A100 38090
25kA
160A LV430390X62A160 35990 LV430395X62A160 43280
250A LV431390X62A250 41210 LV431395X62A250 49370
40A LV429003X62A40 34030 LV429008X62A40 39030
100A LV429003X62A100 34030 LV429008X62A100 39030
160A LV430403X62A160 37010 LV430408X62A160 44030
36kA
250A LV431403X62A250 41510 LV431408X62A250 51000
400A LV432413X63A400 48650 LV432415X63A400 54840
630A LV432813X63A630 55900 LV432815X63A630 65180
40A LV429006X62A40 37010 LV429011X62A40 42020
100A LV429006X62A100 37010 LV429011X62A100 42020
160A LV430406X62A160 42020 LV430411X62A160 45010
50kA
250A LV431406X62A250 44900 LV431411X62A250 52220
400A LV432403X63A400 50000 LV432408X63A400 60570
630A LV432803X63A630 56100 LV432808X63A630 69350
40A LV429004X62A40 40990 LV429009X62A40 47020
100A LV429004X62A100 40990 LV429009X62A100 47020
160A LV430404X62A160 50240 LV430409X62A160 56000
70kA
250A LV431404X62A250 51250 LV431409X62A250 78010
400A LV432404X63A400 64040 LV432409X63A400 80020
630A LV432804X63A630 66000 LV432809X63A630 87730

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 22
Compact NSX Moulded Case Circuit Breakers for
Distribution Network

Micrologic 6 E (Embedded Energy metering and communication capable)

• Features over and above Micrologic 6A.


• Current Measurements (Phase & neutral, Average, Highest of Phases, Ground
Fault current, Maximeter/Minimeter, Current Unbalance between Phases)
• Voltage Measurements (Phase-Phase & Phase-neutral, Average, Ph-Ph & Ph-N
voltage unbalance)
• Frequency Measurements
• Power Quality Indicator (Total Harmonic Distortion for Current and Voltage)
• Power Measurements (Active, Reactive and Apparent Power, total and per
phase and Power Factor and cos (phi))
• Demand Currents and Power Measurements (Demand Values, total & per
phase, Maximum Demand)
• Energy Metering (Active, Reactive and Apparent energy, total and per phase
• Indications, Alarms and Histories (Indication of fault types, Alarms for high/low
threshold, operating histories & time stamped tables)
• Maintenance Indicators (Operation, trip and alarm counters; Operating Hours
Counter; Contact wear: Load profile and thermal image)

Breaking Capacity Icu Three Pole Unit LP Four Pole Unit LP


Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
40A LV429014X62E40 51220 LV429015X62E40 56910
100A LV429014X62E100 51220 LV429015X62E100 56910
25kA
160A LV430390X62E160 51250 LV430395X62E160 57060
250A LV431390X62E250 52280 LV431395X62E250 63570
40A LV429003X62E40 52330 LV429008X62E40 57760
100A LV429003X62E100 52330 LV429008X62E100 57760
160A LV430403X62E160 53190 LV430408X62E160 60000
36kA
250A LV431403X62E250 53810 LV431408X62E250 64520
400A LV432413X63E400 66490 LV432415X63E400 74540
630A LV432813X63E630 75520 LV432815X63E630 92680
40A LV429006X62E40 53110 LV429011X62E40 58630
100A LV429006X62E100 53110 LV429011X62E100 58630
160A LV430406X62E160 53990 LV430411X62E160 60900
50kA
250A LV431406X62E250 54620 LV431411X62E250 65490
400A LV432403X63E400 67490 LV432408X63E400 75880
630A LV432803X63E630 76270 LV432808X63E630 94070
40A LV429004X62E40 55270 LV429009X62E40 61800
100A LV429004X62E100 55270 LV429009X62E100 61800
160A LV430404X62E160 59710 LV430409X62E160 64060
70kA
250A LV431404X62E250 61110 LV431409X62E250 88690
400A LV432404X63E400 75380 LV432409X63E400 90670
630A LV432804X63E630 88570 LV432809X63E630 102460

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 23
Compact NSX Moulded Case Circuit Breakers for
Motor Protection

With Magnetic Trip Unit MA type

• Ics = 100% Icu as per IEC 60947-2


• Adjustable magnetic setting Im 6 -14 x In (2.5 - 100A) & 9 - 14 x In (150 - 200A)
• Type - 2 Co-ordination charts upto 110 kW at 400V
• Breaking Capacity enhancement upto 150kA with a higher capacity upstream
(Cascading)
• Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB
• Rated at 650C as per motor standards

Breaking Capacity Icu Three Pole Unit LP


Rated Current
as per IEC 60947-2 Reference [`]
2.5A LV429745 10980
6.3A LV429744 10980
12.5A LV429743 10980
25A LV429742 10980
36kA
50A LV429741 10980
100A LV429740  10980
150A LV430830 15600
220A LV431748 25590
2.5A LV429755 12400
6.3A LV429754 12400
12.5A LV429753 12400
25A LV429752 12400
50kA
50A LV429751 12400
100A LV429750  12400
150A LV430832 19040
220A LV431752 28090
2.5A LV429765 15930
6.3A LV429764 15930
12.5A LV429763 15930
25A LV429762 15930
70kA
50A LV429761 15930
100A LV429760 15930
150A LV430834 28840
220A LV431756 44740

With Micrologic 1.3M

• Ics = 100% Icu as per IEC 60947-2


• Suitable for Isolation
• Adjustable short circuit Isd = 5 -13 x In
• Front indication LED (Ready LED)
• Type - 2 Co-ordination charts upto 250 kW at 400V
• Rated at 650C as per motor standards

Breaking Capacity Icu Three Pole Unit LP


Rated Current
as per IEC 60947-2 Reference [`]
320A LV432748 35310
36kA
500A LV432948 42460
320A LV432749 38640
50kA
500A LV432949 44350
320A LV432750 49960
70kA
500A LV432950 50270

Note: For higher breaking capacities (100kA and 150kA), contact our nearest Sales office.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 24
Compact NSX Moulded Case Circuit Breakers for
Motor Protection

With Micrologic 2M (μP - ASIC based)

• Ics = 100% Icu as per IEC 60947-2


• Adjustable overload Ir 0.45 - 1 x In
• Adjustable short circuit Isd 5 - 13 x Ir
• Trip class selection: Class 5, Class 10 & Class 20
• Phase unbalance or Phase Loss
• Type - 2 Co-ordination charts upto 315 kW at 400V
• Front indication LED`s (Ready & temperature rise alarm)
• Breaking Capacity enhancement upto 150kA with a higher capacity upstream
(Cascading)
• Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCB
• Rated at 650C as per motor standards

Breaking Capacity Icu Three Pole Unit LP


Rated Current
as per IEC 60947-2 Reference [`]
25A LV429828 15930
50A LV429827 15930
100A LV429825 15930
36kA 150A LV430985 23620
220A LV431160 31490
320A LV432775 42820
500A LV432975 51600
25A LV429833 19770
50A LV429832 19770
100A LV429830 19770
50kA 150A LV430988 26320
220A LV431165 33200
320A LV432776 49210
500A LV432976 51980
25A LV429838 24060
50A LV429837 24060
100A LV429835 24060
70kA 150A LV430991 38760
220A LV431170 42420
320A LV432777 59290
500A LV432977 62140

Note:
• For higher breaking capacities (100kA and 150kA), contact our nearest Sales office.
• For arriving at the Reference of the MCCB with Micrologic 6E-M, please contact our nearest Sales office.

Micrologic 6 E-M

• In addition to Embedded Energy Metering features of Micrologic 6E, the


below Motor
• Application parameters are present in Micrologic 6E-M
• Overload protection: Ir 0.45 - 1 x In
• Short circuit protection: Isd 5 - 13 x Ir
• Ground fault protection: Ig 0.4 - 1 x In (for In=40A) & 0.2 - 1 x In (for In>40A)
and tg I2tON/OFF 0.1 - 0.4s
• Phase unbalance or Phase loss
• Trip class selection: Class 5, Class10, Class20 & Class30
• Cooling fan selection: self cooled or fan cooled motors
• Iunbalance: 10 - 40% of average current and time delay 0.7s (starting) & 1 -
10s (normal operation)
• Locked Rotor: Ijam 1 - 8 x Ir or Ijam can be made OFF and tjam 1 - 30s
• Under-Load (under-current): Iund 0.3 - 0.9 x Ir or Iund can be made OFF and
tund 1 - 200s
• Long Starts Ilong 1 - 8 x Ir or Ilong can be made OFF and tlong 1 - 200s
• Neutral: OFF or 0.5 x Ir or oversized neutral standard
• Front indication LED`s (Ready & temperature rise alarm)
• Zone Selective Interlocking (ZSI) as standard
• Fault distinction on the display of trip unit (type of fault, interrupted fault
current and faulty phase)

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 25
MCCBs for DC Network Protection
Compact NSX DC
Range - 16A to 1200A in Two frames sizes with Thermal Magnetic Trip Unit (TMD)

• Comply to IEC60947 -2 standards


• Breaking Capacity up to 100kA
• Isolation with Positive Break Indication
• Fixed, Plug-in and Draw out type upto 600A
• TMD based trip unit
• New ratings 400A , 600A and 630A to 1200A
NSX100 NSX160 NSX250 NSX400 NSX630 NSX1200
Poles Breaking Capacity 16A to 100A 125A to 160A 200A to 250A 250A to 400A 500A 600A 630A to 1200A*
3P/4P F 36kA @750VDC
3P/4P S 100kA @750VDC
3P/4P F 36kA @500VDC
3P/4P S 100kA @500VDC
2P F 36kA @ 500VDC
2P M 85kA @ 500VDC
2P S 100kA @ 500VDC
2P N 50kA @ 600VDC
1P F 36kA @ 250VDC
1P N 50kA @ 250VDC
1P M 85kA @ 250VDC

Breaking Capacity Icu Three Pole Unit LP Four Pole Unit LP


Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
100A LV438003XTMDC100 14290 LV438008XTMDC100 20335
160A LV438103XTMDC160 17585 LV438108XTMDC160 23745
250A LV438203XTMDC250 21910 LV438208XTMDC250 28575
36kA
400A LV438267 30550 LV438262 34685
500A LV438268 36650 LV438263 44795
600A LV438269 38710 LV438264 46855
100A LV438018XTMDC100 17040 LV438019XTMDC100 23085
160A LV438118XTMDC160 21665 LV438119XTMDC160 28575
250A LV438218XTMDC250 36980 LV438219XTMDC250 39030
100kA
400A LV438277 43625 LV438272 53140
500A LV438278 47640 LV438273 57465
600A LV438279 47640 LV438274 57465

Note:
• For 1P / 2P contact customer care
• NSX 1200 prices on request

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 26
Compact NSX Accessories

Indication contacts SDTAM remote SDx remote Voltage Release Motor Mechanism
indication relay indication relay
module module

Unit LP
Description Reference
[`]
Auxiliary contacts (changeover) Multifunction
OF or SD or SDE or SDV 29450  820
OF or SD or SDE or SDV low level 29452 885
SDE adaptor for trip unit TM or MA or Micrologic 2 $$ LV429451  640
SDX 2-PROGRAMMABLE CONTACTS FOR MICROLOGIC
SDx module 24/415 V AC/DC LV429532 10210
SDTAM contactor tripping module for Micrologic 2- M/6 E-M
SDTAM 24/415 V AC/DC overload fault indication LV429424 10580

$$ To be considered alongwith SDE contact for MCCB with TMD/MA./Micrologic 2 protection.

Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386  LV429406 
2100 2690
220-240 V 50/60 Hz LV429387  LV429407 
380-415 V 50 Hz LV429388  LV429408 
525 V 50 Hz LV429389 LV429409
DC
12 V LV429382 LV429402
24 V LV429390  LV429410 
30 V LV429391 LV429411
48 V LV429392 2100 LV429412 2690
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414 

Installation Accessories
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Spreaders & Phase Barrier
Spreaders (Set of 3) 3P LV431563  600 32492  1360
Spreaders (Set of 4) 4P LV431564  800 32493  1730
Phase Barrier (Set of 6) * - LV432570  685
Interlocking
For Breaker with Rotary Handle LV429369 7960 LV432621 10020
For Breaker with Toggle LV429354 8705 LV432614 10020
Mechanical Interlocking with Base Plate 29349** 16670 32609** 35115
Locking of Rotary Handle
Locking Device LV429344  500 LV432604  685
Ronis Keylock (1 Lock + 1 Key set) 41940  3475 41940  3475
Ronis Keylock (2 Locks + 1 Key set) 41950  6700 41950  6700
Profalux Keylock (1 Lock + 1 Key set) 42888 5870 42888 5870
Profalux Keylock (2 Locks + 1 Key set) 42878 6700 42878 6700
* supplied as standard with spreader
** Mechanical Interlocking with Base Plate to be ordered with Safety trip interlock (LV429270 for 29349 and LV432520 for 32609)

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 27
Compact NSX Accessories

FDM121: Front Display Test Battery Power Supply ModuleB SCM: Breaker Status and
Module Control Module

Motor Mechanism
100/160A Unit LP 250A Unit LP 400/630A Unit LP
Type Voltage
Reference [`] Reference [`] Reference [`]
Motor Mechanism Modules with SDE adaptor (1)
48-60 V LV429440 LV431548 LV432639
110-130 V LV429433 LV431540 LV432640 30950
AC
220-240 V LV429434  19650 LV431541  21720 LV432641 
50/60 Hz
380-415 V LV429435 LV431542 LV432642 31410
440-480 V LV429435 LV431542 LV432647 30950
24-30 V LV429436 LV431543 LV432643
48-60 V LV429437 LV431544 LV432644
DC 25855 28035 37055
110-130 V LV429438 LV431545 LV432645
250 V LV429439 LV431546 LV432646

(1) With every Motor Mechanism, please order 1 no. auxiliary contact additionally. For other voltages of motor mechanism please consult Customer Care.

100/160/250A Unit LP 400/630A Unit LP


Description
Reference [`] Reference [`]
Locking of Motor Mechanism
Keylock adaptor + Ronis keylock (special) LV429449 2595 - -
Locking Device - - LV432649 790
Ronis Keylock - - 41940  3475
Profalux Keylock - - 42888 5870
Torque Limiting Screws (Set of 12) LV429513 1835 LV432513 2155

Monitoring and Control, test tools- Compact and NSX100 - 630


Monitoring and Control (Remote Operation)

Unit LP
Description Reference
[`]
ULP Display Module
Switchboard front display module FDM121 TRV00121  10685
ULP Wiring Accessories
NSX cord L = 0.35 m LV434200 2460
NSX cord L = 1.3 m LV434201 2500
5 RJ45/RJ45 MALE Cord L = 1m TRV00810 2330
10 Stacking connectors for COM interface TRV00217 3630
ULP Communication Module
IFM MODBUS Interface Module LV434000 9330
BSCM ( Breaker Status and Control Module) LV434205  7860
Power Supply Modules
External power supply module 24 V DC-1 A OVC IV
24-30 V DC 54440 13530
48-60 V DC 54441 13530
100-125 V AC 54442 13530
110-130 V AC 54443 15180
200-240 V AC 54444  15180
380-415 V AC 54445 15180
Pocket battery for Micrologic NSX100-630 LV434206 15550
Maintenance Module for advanced configuration and testing, contact our nearest Sales office.
ULP = Universal Logic Plug

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 28
Compact NSX Accessories

Direct Rotary Handle Extended Rotary Handle Plug in Base Draw-Out Chassis Kit

100/160/250A Unit LP 400/630A Unit LP


Description
Reference [`] Reference [`]
Rotary Handles
Standard direct black handle LV429337  1070 LV432597  1605
Standard extended rotary handle LV429338  1700 LV432598  3020
Plug in Base (Complete Kit)
3 Pole LV429289  7650 LV432538  17560
4 Pole LV429290  9900 LV432539  21880
Draw-Out Chassis Kit
3 Pole
Plug In base LV429289  7650 LV432538  17560
Chassis Side Plate for base LV429282  10170 LV432532  12885
Chassis Side Plate for breaker LV429283  5385 LV432533  7505
4 Pole
Plug In base LV429290  9900 LV432539  21880
Chassis Side Plate for base LV429282  10170 LV432532  12885
Chassis Side Plate for breaker LV429283  5385 LV432533  7505
Plug In / Withdrawable version Accessories
Automatic Auxillairy Connectors
1 9-wire fixed connector (for base) LV429273 1060 LV429273 1060
1 9-wire moving connector (for circuit breaker) LV429274 740 LV432523  790
1 support for 2 moving connectors LV429275 565 LV432525  565
Manual Auxillary Connectors
9-wire manual auxiliary connector (fixed + moving) LV429272 3640 LV429272 3640
Note: Above auxiliary connectors to be used with Plug-in and Withdrawable MCCB when Auxiliary Contact, Shunt, UnderVoltage or Motor Mechanism is used.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 29
Compact NSX Automatic Source Changeover System

BA controller (basic)
• Monitoring of “Normal” source & “Automatic” transfer
• Circuit breaker status indication on front of controller: ON, OFF & fault trip
• Voluntary transfer to “Replacement” source (e.g. energy management commands)
UA controller (advanced)
• Monitoring of “normal” source & “Automatic” transfer
• Circuit breaker status indication on front of controller: on, off & fault trip
• Voluntary transfer to “replacement” source (e.g. energy management commands)
• Delayed (adjustable) shutdown of generator set
• Load shedding & reconnection of non-priority loads
• Transfer to “Replacement” source if one of the phases of the “Normal” phase is
absent
• During peak tariff period (energy management commands) forced operation on
“Normal” source if “Replacement” source not operational
With NSX100F - NSX630F 36kA 3P MCCB
Breaker for Breaker for 3P BA Controller Unit MRP 3P UA Controller Unit MRP
Normal Supply Replacement Supply Reference [`] Reference [`]
NSX100F NSX100F LV4A3F100100B4 206765 LV4A3F100100U4 226275
NSX160F NSX100F LV4A3F160100B4 213375 LV4A3F160100U4 232875
NSX160F NSX160F LV4A3F160160B4 219495 LV4A3F160160U4 239005
NSX250F NSX100F LV4A3F250100B4 227140 LV4A3F250100U4 246645
NSX250F NSX160F LV4A3F250160B4 233750 LV4A3F250160U4 253260
NSX250F NSX250F LV4A3F250250B4 247460 LV4A3F250250U4 266970
NSX400F NSX100F LV4A3F400100B4* 265340 LV4A3F400100U4* 267965
NSX400F NSX160F LV4A3F400160B4* 270925 LV4A3F400160U4* 274015
NSX400F NSX250F LV4A3F400250B4* 271405 LV4A3F400250U4* 278130
NSX400F NSX400F LV4A3F400400B4 304410 LV4A3F400400U4 323905
NSX630F NSX160F LV4A3F630160B4* 244255 LV4A3F630160U4* 261655
NSX630F NSX250F LV4A3F630250B4* 255420 LV4A3F630250U4* 272810
NSX630F NSX400F LV4A3F630400B4 307435 LV4A3F630400U4 326945
NSX630F NSX630F LV4A3F630630B4 310415 LV4A3F630630U4 329920

With NSX100F - NSX630F 36kA 4P MCCB


Breaker for Breaker for 4P BA Controller Unit MRP 4P UA Controller Unit MRP
Normal Supply Replacement Supply Reference [`] Reference [`]
NSX100F NSX100F LV4A4F100100B4 214955 LV4A4F100100U4 234450
NSX160F NSX100F LV4A4F160100B4 222370 LV4A4F160100U4 241875
NSX160F NSX160F LV4A4F160160B4 224380 LV4A4F160160U4 243885
NSX250F NSX100F LV4A4F250100B4 238510 LV4A4F250100U4 258015
NSX250F NSX160F LV4A4F250160B4 245885 LV4A4F250160U4 265390
NSX250F NSX250F LV4A4F250250B4 249550 LV4A4F250250U4 267300
NSX400F NSX100F LV4A4F400100B4* 265740 LV4A4F400100U4* 268830
NSX400F NSX160F LV4A4F400160B4* 272950 LV4A4F400160U4* 275300
NSX400F NSX250F LV4A4F400250B4* 275010 LV4A4F400250U4* 284735
NSX400F NSX400F LV4A4F400400B4 317405 LV4A4F400400U4 336915
NSX630F NSX160F LV4A4F630160B4* 265175 LV4A4F630160U4* 282575
NSX630F NSX250F LV4A4F630250B4* 277320 LV4A4F630250U4* 294705
NSX630F NSX400F LV4A4F630400B4 328625 LV4A4F630400U4 348130
NSX630F NSX630F LV4A4F630630B4 339790 LV4A4F630630U4 359295

* Downstream coupling accessories are not available.



Note:
Each reference consists of:
• 2 MCCBs with Motor mechanism & Standard Trip Units.
• 4 Auxiliary contacts 2OF + 2SDE
• 1 Base Plate with IVE unit for mechanical & electrical interlocking
• 1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size
• Control Unit UA or BA
ATS upto 250A are provided with TMD type trip unit & for 400/630A with Micrologic 2 trip unit as standard.
ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied. Prices available on request.
Above given references with BA/UA controller are suitable for 415VAC control supply.
UA controller with 220/240V AC is not available
Replace suffix “4” by “2” for BA controller with 220/240V AC control supply.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 30
Compact NSX Automatic Source Changeover System

BA controller (basic)
• Monitoring of “Normal” source & “Automatic” transfer
• Circuit breaker status indication on front of controller: ON, OFF & fault trip
• Voluntary transfer to “Replacement” source (e.g. energy management commands)
UA controller (advanced)
• Monitoring of “Normal” source & “Automatic” transfer.
• Circuit breaker status indication on front of controller: ON, OFF & fault trip
• Voluntary transfer to “Replacement” source (e.g. energy management commands)
• Delayed (adjustable) shutdown of generator set.
• Load shedding & reconnection of non-priority loads.
• Transfer to “Replacement” source if one of the phases of the “Normal” phase is absent
• During peak tariff period (energy management commands) forced operation on
“Normal” source if “Replacement” source not operational

With NSX100N - NSX630N 50kA 3P MCCB


Breaker for Breaker for 3P BA Controller Unit MRP 3P UA Controller Unit MRP
Normal Supply Replacement Supply Reference [`] Reference [`]
NSX100N NSX100N LV4A3N100100B4 210565 LV4A3N100100U4 230075
NSX160N NSX100N LV4A3N160100B4 219010 LV4A3N160100U4 238510
NSX160N NSX160N LV4A3N160160B4 223245 LV4A3N160160U4 242745
NSX250N NSX100N LV4A3N250100B4 229310 LV4A3N250100U4 248820
NSX250N NSX160N LV4A3N250160B4 237755 LV4A3N250160U4 257255
NSX250N NSX250N LV4A3N250250B4 248110 LV4A3N250250U4 267605
NSX400N NSX100N LV4A3N400100B4* 266100 LV4A3N400100U4* 268500
NSX400N NSX160N LV4A3N400160B4* 271500 LV4A3N400160U4* 275200
NSX400N NSX250N LV4A3N400250B4* 273500 LV4A3N400250U4* 278500
NSX400N NSX400N LV4A3N400400B4 308300 LV4A3N400400U4 327810
NSX630N NSX160N LV4A3N630160B4* 251685 LV4A3N630160U4* 269080
NSX630N NSX250N LV4A3N630250B4* 260415 LV4A3N630250U4* 277805
NSX630N NSX400N LV4A3N630400B4 312865 LV4A3N630400U4 332365
NSX630N NSX630N LV4A3N630630B4 317405 LV4A3N630630U4 336915

With NSX100N - NSX630N 50kA 4P MCCB


Breaker for Breaker for 4P BA Controller Unit MRP 4P UA Controller Unit MRP
Normal Supply Replacement Supply Reference [`] Reference [`]
NSX100N NSX100N LV4A4N100100B4 218085 LV4A4N100100U4 237595
NSX160N NSX100N LV4A4N160100B4 225560 LV4A4N160100U4 245070
NSX160N NSX160N LV4A4N160160B4 225995 LV4A4N160160U4 245505
NSX250N NSX100N LV4A4N250100B4 240475 LV4A4N250100U4 259975
NSX250N NSX160N LV4A4N250160B4 247945 LV4A4N250160U4 267450
NSX250N NSX250N LV4A4N250250B4 262785 LV4A4N250250U4 268855
NSX400N NSX100N LV4A4N400100B4* 268200 LV4A4N400100U4* 274005
NSX400N NSX160N LV4A4N400160B4* 273200 LV4A4N400160U4* 280615
NSX400N NSX250N LV4A4N400250B4* 275465 LV4A4N400250U4* 292875
NSX400N NSX400N LV4A4N400400B4 329665 LV4A4N400400U4 349160
NSX630N NSX160N LV4A4N630160B4* 272705 LV4A4N630160U4* 290100
NSX630N NSX250N LV4A4N630250B4* 284950 LV4A4N630250U4* 302350
NSX630N NSX400N LV4A4N630400B4 340325 LV4A4N630400U4 359835
NSX630N NSX630N LV4A4N630630B4 350995 LV4A4N630630U4 370515

* Downstream coupling accessories are not available.

Note:
Each reference consists of:
• 2 MCCBs with Motor mechanism & Standard Trip Units.
• 4 Auxiliary contacts 2OF + 2SDE
• 1 Base Plate with IVE unit for mechanical & electrical interlocking
• 1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size.
• Control Unit UA or BA

ATS upto 250A are provided with TMD type trip unit & for 400/630A with Micrologic 2 trip unit as standard.
ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied. Prices available on request.
Above given references with BA/UA controller are suitable for 415V AC control supply.
UA controller with 220/240V AC is not available
Replace suffix “4” by “2” for BA controller with 220/240V AC control supply.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 31
Compact NS
Simply A Step Ahead
Circuit breakers and switch-disconnectors from 800 to 3200A
• Category B MCCBs
• Ethernet based monitoring, control, alarm notification for energy, asset and network management
• Built-in energy metering with combined accuracy class of 2% for improved energy efficiency
• Total Discrimination
• Breaking Capacity upto 150kA

2 3 sizes:
from 800 to 3200A
sizes

Masterpact NT 630 to 1600A


Micrologic Micrologic A Micrologic E Micrologic P
without
Display

Compact NS800A to 1600


LB 200kA
Masterpact NW 800 to 4000A
L 150kA
H 70kA
n 50kA
NS630b NS800 NS1000 NS1250 NS1600

Masterpact NW 4000 to 6300A

Compact NS1600b to 3200 H 85kA


N 70kA
NS1600b NS2300 NS2500 NS3200

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 32
Compact NS MCCB for Distribution Network
800A onwards, Manual Fixed Type

With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
With Micrologic 2.0 Manual Fixed
Micrologic 2.0

• LED overload alarm indicator


• Test Facility
• Adjustable neutral protection - N, N/2, OFF for 4 Pole MCCBs

long time

Adjustable overload (Ir) 0.4 - 1 x In


Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir

instantaneous
Isd 4 5
3
2.5 6


2 8

Short circuit (Instantaneous) 1.5 - 10 x Ir


1.5 10
x Ir
setting

Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_3P33466D  59570 INA_4P33469D 77930
50kA 1000 INA_3P33472D 76460 INA_4P33475D 110940
1250 INA_3P33478D 95340 INA_4P33480D 146210
800 INA_3P33467D 72810 INA_4P33470D 93060
70kA 1000 INA_3P33473D 96340 INA_4P33476D 144850
1250 INA_3P33479D 120210 INA_4P33481D 159560
With Extended Rotary Handle
800 INA_3P33466E  63190 INA_4P33469E  82100
50kA 1000 INA_3P33472E  82190 INA_4P33475E  118370
1250 INA_3P33478E  98080 INA_4P33480E 149470
800 INA_3P33467E 76820 INA_4P33470E 97680
70kA 1000 INA_3P33473E 100950 INA_4P33476E 151040
1250 INA_3P33479E 120840 INA_4P33481E 166140

With Micrologic 6.0.A Manual Fixed


Micrologic 6.0 A
• LED overload alarm indicator
2100A
• Test Facility
100 %
• Adjustable neutral protection - N, N/2, OFF
40 %

• With ammeter display & bargraph (Bargraph is unique feature of


Schneider MCCB)
menu

long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20

• Zone Selective Interlocking


.4 1 .5 24
x In at 6 Ir

short time instantaneous


Isd tsd Ii
3
4 5 (s) .4 .4 .3 6
8 10
2.5 6 .3 .2 4 12
2 8 .2 .1 3 15
1.5 10 .1 2 0 2 off
on I t x In
x Ir
setting delay
test
tg

• Communication optional
Ig
D E F (s) .4 .4 .3
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault

• Individual fault indication by LED

Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_3P96466D 84380 INA_4P96469D 102740
50kA 1000 INA_3P96472D 101260 INA_4P96475D 135750
1250 INA_3P96478D 118770 INA_4P96480D 168650
800 INA_3P96467D 97620 INA_4P96470D 117870
70kA 1000 INA_3P96473D 121140 INA_4P96476D 169670
1250 INA_3P96479D 143160 INA_4P96481D 184370
With Extended Rotary Handle
800 INA_3P96466E 88640 INA_4P96469E 107640
50kA 1000 INA_3P96472E 106090 INA_4P96475E 153145
1250 INA_3P96478E 121720 INA_4P96480E 170390
800 INA_3P96467E 102370 INA_4P96470E 123230
70kA 1000 INA_3P96473E 126500 INA_4P96476E 176550
1250 INA_3P96479E 144950 INA_4P96481E 189790
Remarks:Trip Unit Micrologic 6.0.A

Parameter Description Setting


Ir Adjustable Overload Current 0.4 - 1 x In
tr Adjustable Overload time delay 0.5 - 24 sec
Isd Adjustable Short Circuit Current 1.5 - 10 x Ir
tsd Adjustable Short Circuit time delay 0.1 - 0.4sec & OFF (I2t ON/OFF)
Ii Adjustable Instantaneous Current 2 - 15 x In & OFF
Ig Adjustable Earth Fault Current 0.2 - In (for <1250A) / 500 - 1200A (for >=1250A)
tg Adjustable Earth Fault time delay 0.1 - 0.4sec & OFF (I2t ON/OFF)
## Display shows readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are
stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities,
contact our nearest Sales Office
Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 33
Compact NS MCCB for Distribution Network
above 800A Manual Fixed

With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
With Micrologic 2.0E Manual Fixed (With Embedded Energy Metering)
• LED overload alarm indicator
Micrologic 2.0 E

MWh

_ _5.678
• Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power
100 %

40 %
(P,Q,S) ,power factor, power demand, Energy (Ep, Eq, Es)
menu • Adjustable neutral protection - N, N/2, OFF for 4 Pole MCCBs
• Communication option & M2C programmable contacts
long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir

instantaneous
Isd
3 4 5
2.5 6

• Adjustable overload (Ir) 0.4 - 1 x In


2 8
1.5 10
x Ir
setting

• Short circuit (Instantaneous)1.5 - 10 x Ir

Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_8N3PFM2ED1 87180 INA_8N4PFM2ED1 101220
50kA 1000 INA_10N3PFM2ED1 99635 INA_10N4PFM2ED1 145820
1250 INA_12N3PFM2ED1 123700 INA_12N4PFM2ED1 179710
800 INA_8H3PFM2ED1 102180 INA_8H4PFM2ED1 125400
70kA 1000 INA_10H3PFM2ED1 129030 INA_10H4PFM2ED1 184670
1250 INA_12H3PFM2ED1 151140 INA_12H4PFM2ED1 201470
With Extended Rotary Handle
800 INA_8N3PFM2EE1 89160 INA_8N4PFM2EE1 103045
50kA 1000 INA_10N3PFM2EE1 108605 INA_10N4PFM2EE1 147780
1250 INA_12N3PFM2EE1 136600 INA_12N4PFM2EE1 182095
800 INA_8H3PFM2EE1 104385 INA_8H4PFM2EE1 127310
70kA 1000 INA_10H3PFM2EE1 131060 INA_10H4PFM2EE1 186630
1250 INA_12H3PFM2EE1 153130 INA_12H4PFM2EE1 203490

Micrologic 6.0 A
With Micrologic 6.0E Manual Fixed (With Embedded Energy Metering)
2100A
• LED overload alarm indicator
• Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power (P,Q,S)
,power factor,power demand, Energy (Ep, Eq, Es)
100 %

40 %

menu
• Adjustable neutral protection - N, N/2, OFF
• With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir

short time instantaneous


Isd tsd Ii
3
4 5 (s) .4 .4 .3 6
8 10
2.5 6 .3 .2 4 12
.1

• Zone Selective Interlocking


2 8 .2 3 15
1.5 10 .1 2 0 2 off
on I t x In
x Ir
setting delay
test
tg
Ig
D E F (s) .4 .4 .3
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault

• Communication optional
• Individual fault indication by LED
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_8N3PFM6ED1 92300 INA_8N4PFM6ED1 117670
50kA 1000 INA_10N3PFM6ED1 125260 INA_10N4PFM6ED1 163835
1250 INA_12N3PFM6ED1 141615 INA_12N4PFM6ED1 191780
800 INA_8H3PFM6ED1 116400 INA_8H4PFM6ED1 141710
70kA 1000 INA_10H3PFM6ED1 148270 INA_10H4PFM6ED1 204450
1250 INA_12H3PFM6ED1 170520 INA_12H4PFM6ED1 221480
With Extended Rotary Handle
800 INA_8N3PFM6EE1 97965 INA_8N4PFM6EE1 119555
50kA 1000 INA_10N3PFM6EE1 126220 INA_10N4PFM6EE1 165750
1250 INA_12N3PFM6EE1 143585 INA_12N4PFM6EE1 195770
800 INA_8H3PFM6EE1 117360 INA_8H4PFM6EE1 143800
70kA 1000 INA_10H3PFM6EE1 150190 INA_10H4PFM6EE1 206450
1250 INA_12H3PFM6EE1 172550 INA_12H4PFM6EE1 221515
Remarks:Trip Unit Micrologic 6.0E

Parameter Description Setting


Ir Adjustable Overload Current 0.4 - 1 x In
tr Adjustable Overload time delay 0.5 - 24 sec
Isd Adjustable Short Circuit Current 1.5 - 10 x Ir
tsd Adjustable Short Circuit time delay 0.1 - 0.4sec & OFF (I2t ON/OFF)
Ii Adjustable Instantaneous Current 2 - 15 x In & OFF
Ig Adjustable Earth Fault Current 0.2 - In (for <1250A) / 500 - 1200A (for >=1250A)
tg Adjustable Earth Fault time delay 0.1 - 0.4sec & OFF (I2t ON/OFF)

## Display shows readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office
Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 34
Compact NS MCCB for Distribution Network
above 800A Electrical Fixed

With Micrologic Trip Units ( Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
Micrologic 2.0

With Micrologic 2.0 Electrical Fixed


• LED overload alarm indicator
• Test Facility
Ir
long time
tr alarm
• Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCBs
• Adjustable overload (Ir) 0.4 - 1 x In
.8 (s) 4
8
.7 .9 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir

instantaneous
Isd 4 5
3
2.5 6
2 8
1.5 10
x Ir

• Short circuit (instantaneous)1.5 - 10 x Ir


setting

Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_3P93280_20 107750 INA_4P93284_20 122375
50kA 1000 INA_3P93290_20 126815 INA_4P93294_20 165645
1250 INA_3P93300_20 143850 INA_4P93304_20 198925
800 INA_3P93281_20 122705 INA_4P93285_20 145560
70kA 1000 INA_3P93291_20 149145 INA_4P93295_20 203840
1250 INA_3P93301_20 170830 INA_4P93305_20 220350
For Control Voltage 415V AC
800 INA_3P93280_40 107750 INA_4P93284_40 122375
50kA 1000 INA_3P93290_40 126815 INA_4P93294_40 165645
1250 INA_3P93300_40 143850 INA_4P93304_40 198925
800 INA_3P93281_40 122705 INA_4P93285_40 145560
70kA 1000 INA_3P93291_40 149145 INA_4P93295_40 203840
1250 INA_3P93301_40 170830 INA_4P93305_40 220350

With Micrologic 6.0.A Electrical Fixed


• LED overload alarm indicator
Micrologic 6.0 A

2100A

• Test Facility
• Adjustable neutral protection - N, N/2, OFF
100 %

40 %

Ir
.7
menu

long time
.8
.9
tr
(s) 4
8
12
alarm
• With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
• Zone Selective Interlocking
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir

short time instantaneous


Isd tsd Ii
3
4 5 (s) .4 .4 .3 6
8 10
2.5 6 .3 .2 4 12
2 8 .2 .1 3 15
1.5 10 .1 2 0 2 off
on I t x In
x Ir

• Communication optional
setting delay
test
tg
Ig
D E F (s) .4 .4 .3
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault

• Individulal fault indication by LED

Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_3P96280_20 135685 INA_4P96284_20 156345
50kA 1000 INA_3P96290_20 154750 INA_4P96294_20 193590
1250 INA_3P96300_20 165175 INA_4P96304_20 218125
800 INA_3P96281_20 150640 INA_4P96285_20 173495
70kA 1000 INA_3P96291_20 177070 INA_4P96295_20 231775
1250 INA_3P96301_20 198760 INA_4P96305_20 248275
For Control Voltage 415V AC
800 INA_3P96280_40 135685 INA_4P96284_40 156345
50kA 1000 INA_3P96290_40 154750 INA_4P96294_40 193590
1250 INA_3P96300_40 165175 INA_4P96304_40 218125
800 INA_3P96281_40 150640 INA_4P96285_40 173495
70kA 1000 INA_3P96291_40 177070 INA_4P96295_40 231775
1250 INA_3P96301_40 198760 INA_4P96305_40 248275

Remarks: Trip Unit Micrologic 6.0.A

Parameter Description Setting


Ir Adjustable Overload Current 0.4 - 1 x In
tr Adjustable Overload time delay 0.5 - 24 sec
Isd Adjustable Short Circuit Current 1.5 - 10 x Ir
tsd Adjustable Short Circuit time delay 0.1 - 0.4sec & OFF (I2t ON/OFF)
Ii Adjustable Instantaneous Current 2 - 15 x In & OFF
Ig Adjustable Earth Fault Current 0.2 - In (for <1250A) / 500 - 1200A (for >=1250A)
tg Adjustable Earth Fault time delay 0.1 - 0.4sec & OFF (I2t ON/OFF)

## Display shows Readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office
Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 35
Compact NS MCCB for Distribution Network
above 800A Electrical Fixed

With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
Micrologic 2.0 E
With Micrologic 2.0E Electrical Fixed (With Embedded Energy Metering)
MWh

_ _5.678 • LED overload alarm indicator


100 % • Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power (P,Q,S)
,power factor,power demand, Energy (Ep, Eq, Es)
40 %

• Adjustable neutral protection - N, N/2,OFF for 4 Pole MCCBs


menu

long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20

• Adjustable overload (Ir) 0.4 - 1 x In


.4 1 .5 24
x In at 6 Ir

instantaneous
Isd
3 4 5
2.5 6
2 8
1.5 10
x Ir
setting

• Short circuit (instantaneous)1.5 - 10 x Ir

Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_8N3PFE2E0120 128390 INA_8N4PFE2E0120 149725
50kA 1000 INA_10N3PFE2E0120 147690 INA_10N4PFE2E0120 187230
1250 INA_12N3PFE2E0120 165440 INA_12N4PFE2E0120 221070
800 INA_8H3PFE2E0120 141080 INA_8H4PFE2E0120 166760
70kA 1000 INA_10H3PFE2E0120 170440 INA_10H4PFE2E0120 226030
1250 INA_12H3PFE2E0120 192460 INA_12H4PFE2E0120 242810
For Control Voltage 415V AC
800 INA_8N3PFE2E0140 128390 INA_8N4PFE2E0140 149725
50kA 1000 INA_10N3PFE2E0140 147690 INA_10N4PFE2E0140 187230
1250 INA_12N3PFE2E0140 165440 INA_12N4PFE2E0140 221070
800 INA_8H3PFE2E0140 141080 INA_8H4PFE2E0140 166760
70kA 1000 INA_10H3PFE2E0140 170440 INA_10H4PFE2E0140 226030
1250 INA_12H3PFE2E0140 192460 INA_12H4PFE2E0140 242810

With Micrologic 6.0E Electrical Fixed (With Embedded Energy Metering)


• LED overload alarm indicator
• Measurement: Ammeter, current demand, voltages (ph-ph, ph-N, unblance), Power (P,Q,S), power factor, power demand, Energy (Ep,Eq,Es)
• Adjustable neutral protection - N, N/2, OFF
• With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
• Zone Selective Interlocking
• Communication optional
• Individulal fault indication by LED
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_8N3PFE6E0120 145930 INA_8N4PFE6E0120 162485
50kA 1000 INA_10N3PFE6E0120 165330 INA_10N4PFE6E0120 204750
1250 INA_12N3PFE6E0120 182640 INA_12N4PFE6E0120 239200
800 INA_8H3PFE6E0120 161170 INA_8H4PFE6E0120 184360
70kA 1000 INA_10H3PFE6E0120 188030 INA_10H4PFE6E0120 243620
1250 INA_12H3PFE6E0120 210090 INA_12H4PFE6E0120 260450
For Control Voltage 415V AC
800 INA_8N3PFE6E0140 145930 INA_8N4PFE6E0140 162485
50kA 1000 INA_10N3PFE6E0140 165330 INA_10N4PFE6E0140 204750
1250 INA_12N3PFE6E0140 182640 INA_12N4PFE6E0140 239200
800 INA_8H3PFE6E0140 161170 INA_8H4PFE6E0140 184360
70kA 1000 INA_10H3PFE6E0140 188030 INA_10H4PFE6E0140 243620
1250 INA_12H3PFE6E0140 210090 INA_12H4PFE6E0140 260450

Accessories
For Compact NS800 - 1600A
Shunt Release Undervoltage
Type Voltage Unit LP [`] Reference Unit LP [`]
Reference
Voltage Releases
24 V 33659 5100 33668 5200
AC 48 V 33660 5100 33669 5200
50/60 Hz 110-130 V 33661  5100 33670 5200
220-240 V 33662  5100 33671  5200
380-415 V 33664 5100 33673  5200
24 V 33659 5100 33668 5200
DC 48 V 33660 5100 33669 5200
125 V 33661  5100 33670 5200
250 V 33662  5100 33671  5200

Description NS800 to 1600 Reference Unit LP [`]


Spreaders (Set of 3) 3P 33622  8500
Spreaders (Set of 4) 4P 33623  10580

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 36
The easy choice for quality and value

EasyPact CVS
LV circuit breakers from 16A to 800A

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 Safe
NORMAL STOCK ITEMS
Reliable Simple W.E.F. March 12, 2018

schneider-electric.co.in 37
EasyPact CVS
Easy Choice for Quality and Value

• EasyPact CVS MCCBs upto 630A is the easy choice for all your most common electrical distribution
applications
• Encapsulated double break roto technique ensures outstanding current limiting capability
• High electrical / mechanical endurance for enhanced service life
• Single accessory reference for different functions – on/off, trip and fault trip – improves shop floor efficiency
• Separate electrical fault indication for ease of fault diagnosis
• Suitable for isolation

Range Details:
• Breaking capacity 25kA to 50kA, Ics = 100% Icu
• TMD & Microprocessor trip units (400 & 630A) are available
• 3P & 4P versions available
• Common accessories upto 630A

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 38
EasyPact CVS 100 BS Moulded Case Circuit Breakers for
Distribution Network

With Thermal Magnetic Trip Unit (TMD)

• Range upto 100A


• 3P and 4P version available

Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 BS Overload Setting (Ir) 0.8 - 1 x In
16A LV510930 5740 LV510950 7780
20A LV510931 5740 LV510951 7780
25A LV510932 5740 LV510952 7780
32A LV510933 5740 LV510953 7780
25kA* 40A LV510934 5740 LV510954 7780
50A LV510935 5740 LV510955 7780
63A LV510936 5740 LV510956 7780
80A LV510937 5740 LV510957 7780
100A LV510938 5740 LV510958 7780

Accessories
CVS100BS Unit LP
Description
Reference [`]
Auxiliary contacts (changeover) Multifunction
Auxiliary Switch 1 C/O EZAUX10  740
Alarm Switch 1 C/O EZAUX01 740
Alarm - Auxiliary Switch EZAUX11  1105
Spreaders
Spreaders *(Set Of 3) 3P EZASPDR3P  300
Spreaders *(Set Of 4) 4P EZASPDR4P  400
Rotary Handle
Direct Rotary handle EZAROTDS  1055
Extended Rotary handle EZAROTE 1580
Shunt Release
AC
100-130 V EZASHT100AC 1580
200-277 V EZASHT200AC  1580
380-480 V EZASHT380AC 1580
DC
24 V EZASHT024DC 1580
48 V EZASHT048DC 1580

*Ics=17kA

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 39
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network

• Ics = 100% Icu as per IEC 60947-2

Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
Easypact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510300  6250 LV510310 8640
25A LV510301  6250 LV510311  8640
32A LV510302  6250 LV510312  8640
40A LV510303  6250 LV510313  8640
50A LV510304  6250 LV510314 8640
25kA 63A LV510305  6250 LV510315  8640
80A LV510306  6250 LV510316  8640
100A LV510307  6250 LV510317  8640
125A LV516302  9030 LV516312  10940
160A LV516303  11780 LV516313  13980
200A LV525302  15750 LV525312 19360
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
25kA 250A LV525303  18200 LV525313 22120

Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
Easypact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510330  8810 LV510340 10940
25A LV510331  8810 LV510341 10940
32A LV510332  8810 LV510342  10940
40A LV510333  8810 LV510343  10940
50A LV510334  8810 LV510344 10940
36kA 63A LV510335  8810 LV510345  10940
80A LV510336  8810 LV510346 10940
100A LV510337  8810 LV510347  11300
125A LV516332  9630 LV516342 11930
160A LV516333  12950 LV516343 15310
200A LV525332 18010 LV525342  22400
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525333 19600 LV525343  23960
320A LV540305 25100 LV540308  31760
36kA 400A LV540306 25330 LV540309  32050
500A LV563305  27950 LV563308  34870
630A** LV563306  30620 LV563309  37910

Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
16A LV510470  11560 LV510480 14210
25A LV510471 11560 LV510481 14210
32A LV510472  11560 LV510482  14210
40A LV510473 11560 LV510483 14210
50A LV510474 11560 LV510484 14210
50kA 63A LV510475  11560 LV510485  14210
80A LV510476  11560 LV510486 14210
100A LV510477  11560 LV510487  14210
125A LV516462  14890 LV516467 16290
160A LV516463  15500 LV516468 18460
200A LV525452 20150 LV525457  25200
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525453 21660 LV525458  26580
320A LV540315  25610 LV540318 32010
50kA 400A LV540316  26120 LV540319  32650
500A LV563315  30300 LV563318 38230
630A** LV563316  31990 LV563319  40690

Note:
• EasyPact CVS can also be used for DC network protection (from 16-630A TMD)
• For performance and other details contact our nearest Sales Office.
* *630A @ 300C & 600A @ 400 C for TMD630A MCCB

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 40
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network

Easypact CVS 800A with


Thermal Magnetic type trip unit.
• Ics = 100% Icu as per IEC 60947-2
• TMD type Trip Unit
• Adjustable overload from 0.8 - 1 x In
• Adjustable short circuit for each phase from 3.5 - 10 x Ir

Breaking Capacity Ics Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
36kA 800A LV580300  49310 LV580301  53210
50kA 800A LV580302  54530 LV580303  60440

Easypact CVS 400 to 630A With Microprocessor Based Trip Unit


• Ics = 100% Icu as per IEC 60947-2
• Suitable for Isolation
• Adjustable Overload from 0.5 to 1*In
• Adjustable Short Circuit from 2 to 10*Ir
• Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB
• Inbuilt Thermal Memory

Breaking Capacity Ics Three Pole Unit LP Four Pole Unit LP


Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 400 to 630A
400A LV540505  28790 LV540506  35540
36 kA
630A LV563505  31650 LV563506  42000
400A LV540510  31460 LV540511  40160
50 kA
630A LV563510  34430 LV563511  44600

Moulded Case Circuit Breakers for Motor Protection


Breaking Capacity 50kA, Ics=Icu
E26988

Current Rating 2.5 6.3 12.5 25 50 100 150 220 320 500
CVS 100 6..14In
CVS 160/250 9..14In
CVS 400 6..13In
CVS 630 6..13In

Frame 1 2.5 to 220A


Frame 2 320 to 500A

With Magnetic Trip Unit MA type


Three Pole Unit MRP
Breaking Capacity Ics as per IEC 60947-2 Rated Current
Reference [`]
2.5A LV510450 7560
6.3A LV510451 7560
12.5A LV510452  7980
50kA 25A LV510453  10730
50A LV510454  10780
100A LV510455  10850
150A LV516451  13870
Three Pole Unit LP
Breaking Capacity Ics as per IEC 60947-2 Rated Current
Reference [`]
220A LV525442  15640
50kA 320A LV540552  23200
500A LV563552 29000

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 41
Easy-Pact CVS Switch Disconnector Version

• Suitable for Isolation with positive contact indication as defined by standard


IEC 60947-3.
• Compliance to utilization categories AC22A or AC23A
• Self protected due to high magnetic-set release
• Two frame sizes upto 630A
• Available in fixed version.
• Common Accessories as that of EasyPact CVS circuit breaker

Rated Current Three Pole Reference Unit MRP [`] Four Pole Reference Unit MRP [`]
100A LV510425 5450 LV510426 6900
160A LV516425 6500 LV516426 8170

Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]

250A LV525425 13620 LV525426 18130

400A LV540400 19970 LV540401 25420

630A LV563400 22700 LV563401 30520

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 42
EasyPact CVS Accessories for EasyPact CVS

Indication contacts Voltage Release Padlocking accessory Direct Rotary Handle Extended Rotary Handle

Accessories for EasyPact CVS 100 - 630A


Auxiliary Contacts (Changeover) Multifunction
Unit LP
Description Reference
[`]
OF or SD or SDE or SDV 29450  820
OF or SD or SDE or SDV low level 29452 885
SDE adapter for trip unit TM or MA or ETS 2.3 $$ LV429451  640
$$: To be considered alongwith SDE contact for MCCB with TMD/ETS 2.3/MA Trip Unit

Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384  LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386  LV429406 
2100 2690
220-240 V 50/60 Hz LV429387  LV429407 
380-415 V 50 Hz LV429388  LV429408 
525 V 50 Hz LV429389 LV429409
DC
12 V LV429382 LV429402
24 V LV429390  LV429410 
30 V LV429391 LV429411
48 V LV429392 2100 LV429412 2690
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414

Rotary Handles
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Direct rotary handle
Standard black handle LV429337  1070 LV432597  1605
Extended rotary handle
Standard extended rotary handle LV429338  1700 LV432598  3020

Installation Accessories
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV431563  600 32492  1360
Spreaders (Set of 4) 4P LV431564  800 32493  1730
Phase Barriers (Set of 6) * LV432570  685
Interlocking
For Breaker with Rotary Handle LV429369 7960 LV432621 10020
For Breaker with Toggle LV429354 8705 LV432614 10020
Mechanical Interlocking with Base Plate 29349** 16670 32609** 35115
Locking of Rotary Handle
Locking Device LV429344  500 LV432604  685
Ronis Keylock (1 Lock + 1 Key set) 41940  3475 41940  3475
Ronis Keylock (2 Locks + 1 Key set) 41950  6700 41950  6700
Profalux Keylock (1 Lock + 1 Key set) 42888 5870 42888 5870
Profalux Keylock (2 Locks + 1 Key set) 42878 6700 42878 6700
* supplied as standard with spreaders
** Mechanical Interlocking with Base Plate to be ordered with Safety trip interlock (LV429270 for 29349 and LV432520 for 32609)

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 43
EasyPact CVS Accessories for EasyPact CVS

Accessories for CVS 100 - 630A


Manual Source change-over systems
• An additional accessory interlocks two devices with rotary handles to create a source changeover system. Closing of one device is possible only if
the second is open.
• This function is compatible with direct or extended rotary handles.
• Up to three padlocks can be used to lock in the OFF or ON position.
Unit LP
Description Reference
[`]
Mechanical interlocking for circuit breakers
With toggles 100A to 250A LV429354 8705
With rotary handles 100A -250A LV429369 7960
With toggles 400A to 630A LV432614 10020
With rotary handles 400A to 630A LV432621 10020

Accessories for CVS 800A

Auxiliary/Alarms contacts
Unit LP
Description Reference
[`]
Auxiliary Switch 1 C/O LV580075 1130
Alarm Auxiliary switch 1 c/o LV580079 1585

Voltage Releases
Shunt Release Unit MRP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
220-240 V 50/60 Hz LV580061 2155 LV580071 2700

Rotary Handles
800A Unit LP
Description
Reference [`]
Extended rotary handle
Standard extended rotary handle LV580081  1890

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 44
Type 2 Co-ordination Table Fuseless (DOL Starter) with
EasyPact CVS
• Standard : IEC 60947-4-1
• Short Circuit Protection Device type: MCCB
• Performance «Iq» (kA) : 50kA
• Operational Voltage (Ue) : 415VAC / 50Hz

FLC Circuit Rated Thermal


Motor le Irm Contactor Thermal Iq Ir
I(A) Breaker current Setting range
rating kW max (A) Type Relay Type kA kA
415V Type (A) Irth
0.37 1.1 1.6 CVS100-MA 2.5 6..13 22.5 LC1E09 LRE06 (3) 1..1.6 50 1
0.55 1.5 1.6 CVS100-MA 2.5 6..14 32.5 LC1E09 LRE06 (3) 1..1.6 50 1
0.75 1.8 2.5 CVS100-MA 2.5 6..14 32.5 LC1E09 LRE07 (3) 1.6..2.5 50 1
1.1 2.6 4 CVS100-MA 6.3 6..14 57 LC1E32 LRE08 (3) 2.5..4 50 1
1.5 3.4 4 CVS100-MA 6.3 6..14 57 LC1E32 LRE08 (3) 2.5..4 50 1
2.2 4.8 6 CVS100-MA 6.3 6..14 82 LC1E32 LRE10 (3) 4..6 50 1
3 6.5 8 CVS100-MA 12.5 6..14 113 LC1E80 LRE12 (1) (3) 5.5..8 50 1
4 8.2 10 CVS100-MA 12.5 6..14 138 LC1E80 LRE14 (1) (3) 7 ..10 50 1
5.5 11 12.5 CVS100-MA 12.5 6..14 163 LC1E80 LRE16 (1) (3) 9..13 50 1
7.5 14 18 CVS100-MA 25 6..14 250 LC1E80 LRE21 (1) (3) 12..18 50 3
10 19 25 CVS100-MA 25 6..14 325 LC1E80 LRE322 (2) (3) 17..25 50 3
11 21 25 CVS100-MA 25 6..14 325 LC1E80 LRE322 (2) (3) 17..25 50 3
15 28 32 CVS100-MA 50 6..14 450 LC1E80 LRE353 (2) (3) 23..32 50 3
18.5 34 40 CVS100-MA 50 6..14 550 LC1E80 LRE355 (2) (3) 30..40 50 3
22 40 50 CVS100-MA 50 6..14 650 LC1E80 LRE357 (2) 37..50 50 3
30 55 63 CVS100-MA 100 6..14 900 LC1E120 LRE480 51..81 50 3
37 66 100 CVS100-MA 100 6..14 1100 LC1E120 LRE481 62..99 50 5
45 80 100 CVS100-MA 100 6..14 1300 LC1E120 LRE481 62..99 50 5
55 100 135 CVS160-MA 150 9..14 1500 LC1E160 LRE482 84..135 50 5
75 135 150 CVS160-MA 150 9..14 1950 LC1E160 LRE483 124..198 50 10
90 160 185 CVS250-MA 220 9..14 2420 LC1E300 LRE484 146..234 50 10
110 200 220 CVS250-MA 220 9..14 2860 LC1E300 LRE484 146..234 50 10
132 230 265 CVS400-MA 320 6..13 3500 LC1E300 LRE485 174..279 50 10
160 270 315 CVS400-MA 320 6..13 4160 LC1E300 LRE486 208..333 50 10
200 361 400 CVS630-MA 500 6..13 5700 LC1F500 LR9-F73 79 300..500 50 18
220 380 500 CVS630-MA 500 6..13 6500 LC1F500 LR9-F73 79 300..500 50 18
250 430 500 CVS630-MA 500 6..13 6500 LC1F500 LR9-F73 79 300..500 50 18

(1) Separate mounting with LAEB1 terminal block


(2) Separate mounting with LAEB3 terminal block
(3) Type 1 for O/L relay

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 45
EasyPact EZC

Safe, Reliable and Easy

With just three sizes of circuit breakers, Schneider Electric’s EasyPact EZC system is the simple, universal solution, particularly
adapted to Buildings and OEM segments
• Suitability for Isolation ensures safety
• Compliance to RoHS (Restriction of Hazardous Substances) for environment safety
Range Details:
• Global MCCB offer from 15A to 600A
• Breaking capacity upto 50kA @ 415 V AC
• 1P, 2P, 3P and 4P versions available
• EZC AC version is suitable for DC applications upto 250V DC (15A to 250A breaking capacity up to 30kA)
• Built in Earth leakage version 63A to 250A @ Icu36kA.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 46
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network

With Fixed Thermal Magnetic Trip Unit (TMD)

• Conforms to IEC60947-2
• Suitable for isolation
• Suitable for EasyPact Busbar system

Unit MRP
BREAKING CAPACITY ICU AS PER IEC 60947-2 Rated Current Three Pole Reference
[`]
16A EZC100F3016
20A EZC100F3020
25A EZC100F3025
32A EZC100F3032
“10 kA @ 415V AC
40A EZC100F3040 2640
5kA @ 250V DC (2pole in series)”
50A EZC100F3050
63A EZC100F3063
80A EZC100F3080
100A EZC100F3100
125A EZC250F3125 5955
150A EZC250F3150 6000
“18 kA @ 415V AC
160A EZC250F3160 6800
5kA @ 250V DC (2pole in series)”
175A EZC250F3175
8355
200A EZC250F3200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“18 kA @ 415V AC
250A EZC250F3250 9775
5kA @ 250V DC (2pole in series)”

Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Single Pole
[`]
16A EZC100N1016
20A EZC100N1020
25A EZC100N1025
32A EZC100N1032
"18 kA @ 240V AC
40A EZC100N1040 1885
5kA @ 125V DC "
50A EZC100N1050
63A EZC100N1063
80A EZC100N1080
100A EZC100N1100
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Two Pole Reference
[`]
16A EZC100H2016
20A EZC100H2020
25A EZC100H2025
32A EZC100H2032
“50 kA @ 240V AC
40A EZC100H2040 3080
10kA @ 250V DC (2pole in series)”
50A EZC100H2050
63A EZC100H2063
80A EZC100H2080
100A EZC100H2100
125A EZC250H2125 6300
150A EZC250H2150 7420
“85 kA @ 240V AC
160A EZC250H2160 7420
30kA @ 250V DC (2pole in series)”
175A EZC250H2175
8935
200A EZC250H2200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“85 kA @ 240V AC
250A EZC250H2250 9200
30kA @ 250V DC (2pole in series)”
Note:
• Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
• 630A and other breaking capacity versions on request.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 47
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network

Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
15A EZC100H3015 EZC100H4015
20A EZC100H3020 EZC100H4020
25A EZC100H3025 EZC100H4025
32A EZC100H3032 EZC100H4032
“30 kA @ 415V AC
40A EZC100H3040 4160 EZC100H4040 5770
10kA @ 250V DC (2pole in series)”
50A EZC100H3050 EZC100H4050
63A EZC100H3063 EZC100H4063
80A EZC100H3080 EZC100H4080
100A EZC100H3100 EZC100H4100
125A EZC250N3125 6100 EZC250N4125 8420
“25 kA @ 415V AC
160A EZC250N3160 7400 EZC250N4160 9910
20kA @ 250V DC (2pole in series)”
200A EZC250N3200 8780 EZC250N4200 11080
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
"25 kA @ 415V AC
250A EZC250N3250 10035 EZC250N4250 12990
20kA @ 250V DC (2pole in series)"
Breaking Capacity Icu as per Rated Current Three Pole Reference Unit MRP Four Pole Unit MRP
IEC 60947-2 [`] Reference [`]
125A EZC250H3125 6400 EZC250H4125 8630
"36 kA @ 415V AC
160A EZC250H3160 8390 EZC250H4160 10800
30kA @ 250V DC (2pole in series)"
200A EZC250H3200 10410 EZC250H4200 14070
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
“36 kA @ 415V AC
250A EZC250H3250 11640 EZC250H4250 15720
30kA @ 250V DC (2pole in series)”
320A EZC400H3320N 18220 EZC400H4320N 21000
400A EZC400H3400N 18790 EZC400H4400N 24560
“50 kA @ 415V AC“
500A EZC630H3500N 23700 EZC630H4500N 30800
600A EZC630H3600N 24700 EZC630H4600N 32200

Note:
• Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
• 630A and other breaking capacity versions on request.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 48
EasyPact EZC Accessories

EZC100 Unit LP EZC250 Unit LP


Description
Reference [`] Reference [`]
Auxiliary Contacts (changeover) Multifunction
Auxiliary Switch 1 C/O EZAUX10  740 EZEAX  890
Alarm Switch 1 C/O EZAUX01 740 EZEAL  890
Alarm - Auxiliary Switch EZAUX11  1105 EZEAXAL 1320
Spreaders
Spreaders *(Set Of 3) 3P EZASPDR3P  300 EZESPDR3P  450
Spreaders *(Set Of 4) 4P EZASPDR4P  400 EZESPDR4P 590
Phase Barriers EZAFASB2 185 EZEFASB2 255
Rotary Handle
Direct Rotary handle EZAROTDS  1055 EZEROTDS 1320
Extended Rotary handle EZAROTE 1580 EZEROTE 1580
Shunt Release
AC
100-130 V EZASHT100AC EZESHT100AC 1580
200-277 V EZASHT200AC  1580 EZESHT200AC  1580
380-480 V EZASHT380AC EZESHT400AC 1580
DC
24 V EZASHT024DC EZESHT024DC 1580
1580
48 V EZASHT048DC EZESHT048DC 1580

Unit LP
Description EZC 400/600 Reference
[`]
Auxiliary Contacts
OF or SD or SDE 29450 820
Spreaders
Spreaders (Set of 3) 3P 32492 1360
Spreaders (Set of 4) 4P 32493 1730
Phase Barriers (Set of 6) LV432570 685
Rotary Handle
Direct Rotary handle LV432597 1605
Extended Rotary handle LV432598 3020
Shunt Release
AC 220-240 V 50/60 Hz LV429387 2100

EasyPact Range Busbar Systems


• Available for 250A, 400A & 630A main incoming current
• Available for 4,6,8 & 12 ways (3-pole) EasyPact 100A (max) outgoing MCCBs
• EZ Busbar rated 400A and 630A can accept the 2 ways or 4 ways branch
extension for upto four additional 250A max outgoing circuits

Unit LP
[In] Rated Current Description Reference
[`]
EZ busbar 250A 4ways EZB250W04 8245
EZ busbar 250A 6ways EZB250W06 10425
250 A EZ busbar 250A 8ways EZB250W08 12610
EZ busbar 250A 10ways EZB250W10 14815
EZ busbar 250A 12ways EZB250W12 16995
EZ busbar 400A 4ways EZB400W04 10425
EZ busbar 400A 6ways EZB400W06 12610
400 A EZ busbar 400A 8ways EZB400W08 14815
EZ busbar 400A 10ways EZB400W10 16995
EZ busbar 400A 12ways EZB400W12 19180
EZ busbar 630A 4ways EZB630W04 12610
EZ busbar 630A 6ways EZB630W06 14815
630 A EZ busbar 630A 8ways EZB630W08 16995
EZ busbar 630A 10ways EZB630W10 19180
EZ busbar 630A 12ways EZB630W12 21370

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 49
EasyPact NKS Moulded Case Circuit Breakers for
Distribution Network
AC MCCB
Fixed Thermal Magnetic Trip Unit (TMD)
• Conforms to IEC60947-2

Unit MRP
Breaking Capcity Icu as per IEC60947-2 Rated Current Reference
[`]
15 NKS100R015AC3P 1500
20 NKS100R020AC3P 1500
25 NKS100R025AC3P 1500
32 NKS100R032AC3P 1500
40 NKS100R040AC3P 1500
50 NKS100R050AC3P 1500
63 NKS100R063AC3P 1500
75 NKS100R075AC3P 1500
10kA *
100 NKS100R100AC3P 1500
110 NKS160R110AC3P 3470
125 NKS160R125AC3P 3470
140 NKS160R140AC3P 3840
150 NKS160R150AC3P 3840
160 NKS160R160AC3P 3840
175 NKS200R175AC3P 5050
200 NKS200R200AC3P 5050

*Ics=5kA

EasyPact Unit LP EasyPact Unit LP


Description
NKS100 [`] NKS 125A to 200 [`]
Auxiliary contacts (changeover) Multifunction
Auxiliary Switch 1 C/O EZAUX10 740 AX1CT1L 705
Alarm Switch 1 C/O EZAUX01 740 AL1CT1NR 790
Alarm - Auxiliary Switch EZAUX11 1105
Spreaders
Spreaders *(Set Of 3) 3P EZASPDR3P 300 NKSP13 280
Phase Barriers EZAFASB2 185 - -
Rotary Handle
Direct Rotary handle EZAROTDS 1055 - -
Extended Rotary handle EZAROTE 1580 NDHOMT1 1095
Shunt Release
AC
100-130 V EZASHT100AC 1580 -
200-277 V EZASHT200AC 1580 SHT240ACT1L 635
380-480 V EZASHT380AC 1580 - -
440 V - - - -
DC
24 V EZASHT024DC 1580 - -
48 V EZASHT024DC 1580 - -
110 V EZASHT048DC 1580 - -
220 V - - - -
AC
UVR 200-240VAC On Request - -
220 V - - UVT220/240ACT1 1175
415 V

Note:
• Contact customer care for other accessories

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 50
Simpact NKS DC MCCB

• Fixed Thermal Magentic Settings


Breaking Capacity Icu One Pole Unit MRP
Rated Current
as per IEC 60947-2 Reference [`]
10A NKS100R010DC1P
15A NKS100R015DC1P
20A NKS100R020DC1P
5 kA 30A NKS100R030DC1P
125VDC 40A NKS100R040DC1P 1320
L/R = 10ms 50A NKS100R050DC1P
60A NKS100R060DC1P
75A NKS100R075DC1P
100A NKS100R100DC1P

• Fixed Thermal Magentic Settings


Breaking Capacity Icu Two Pole Unit MRP Three Pole Unit MRP
Rated Current
as per IEC 60947-2 Reference* [`] Reference [`]
10A NKS100R010DC2P NKS100R010DC3P
15A NKS100R015DC2P NKS100R015DC3P
20A NKS100R020DC2P NKS100R020DC3P
25A NKS100R025DC2P NKS100R025DC3P
30A NKS100R030DC2P NKS100R030DC3P
3940 4460
40A NKS100R040DC2P NKS100R040DC3P
50A NKS100R050DC2P NKS100R050DC3P
10 kA 60A NKS100R060DC2P NKS100R060DC3P
250VDC 75A NKS100R075DC2P NKS100R075DC3P
L/R = 10ms 100A NKS100R100DC2P NKS100R100DC3P
110A NKS160R110DC2P NKS160R110DC3P
125A NKS160R125DC2P NKS160R125DC3P
140A NKS160R140DC2P 7355 NKS160R140DC3P 8070
150A NKS160R150DC2P NKS160R150DC3P
160A NKS160R160DC2P NKS160R160DC3P
175A NKS200R175DC2P NKS200R175DC3P
7590 8725
200A NKS200R200DC2P NKS200R200DC3P
Note: *2 Pole MCCB shall be in 3P dimensions.
Spreaders are supplied as standard only with NKS200R for lower ratings consider spreader prices extra

Simpact NKS DC Accessories


Unit LP Unit LP
Voltage Reference Description Reference
[`] [`]
Shunt Release Auxiliary contacts (changeover)
AC Auxiliary Switch 1 C/O AX1CT1L 705
240 V SHT240ACT1L 635 Alarm Switch 1 C/O AL1CT1NR 790
Under Voltage Release Rotary handles
AC Standard extended rotary handle NDHOMT1 1095
220 V UVT220/240ACT1  1175
Spreaders
Spreaders (Set of 3) 3P NKSP13  280

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 51
Unique Modular Ground Fault Protection

Earth Fault Protection for EasyPact CVS/ Compact NSX MCCBs


Modular Device for EasyPact CVS/ Compact NSX Range Moulded Case Circuit Breakers
• Adjustable earth fault sensitivity selection 10 to 60%
• Adjustable time delay Inst/ 0.5 - 3 sec.
• System healthiness check through LED indication
• Individual fault indication for OL/SC, EF when used with Compact NSX & EasyPact CVS (Optional)
• Test facility to check healthiness of earth fault protection system without tripping MCCB
• Suitable for 3P3W & 3P4W electrical distribution network

Protection of electrical distribution


network against fire

Relay Module 3 Ph + 3W Unit MRP 3 Ph + 4W Unit MRP


MCCB Frame
rated current Reference [`] Reference [`]
CVS/NSX100 32, 40, 50, 63, 80, 100 GFP11CT13P  4930 GFP11CT14P  5400
CVS/NSX 160 / 250 125, 160, 200, 250 GFP12CT23P  5610 GFP12CT24P  6330
CVS/NSX 400 / 630 400, 630 GFP13CT33P  8470 GFP13CT34P  9250
CVS 800 800 GFP14CT43P 10440 GFP14CT44P 11690

Note: Kindly order one no. Shunt trip coil along with one Ground Fault Protection Module for CVS100 to 630. Order one auxiliary contact alongwith shunt coil for
CVS800.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 52
Earth Leakage Protection

Earth Leakage Protection is obtained by: Fitting a VIGI Module on the Circuit Breakers
VIGI Module Earth Leakage Device for EasyPact CVS/ Compact NSX Range Moulded
Case Circuit Breakers

Protection of people VIGI Module CVS + VIGI NSX + VIGI

• Compliance with Standards - IEC60947-2 appendix B, IEC 60255-4 and IEC60801-2 to 5 covering protection against
nuisance tripping due to:
◦ Transient overvoltages, lightning strikes
◦ Switching of devices on the distribution system
◦ Electrostatic discharges and radio frequency disturbances
• Device can be equipped with multifunction aux contact of MCCB to remotely signal tripping due to earth fault
• Self powered - “no aux supply required”
• Instantaneous tripping at 30mA in less the 40ms for human protection
• Direct acting device - no shunt/UV release required in MCCB

Three Pole (1) Unit MRP Four Pole Unit MRP


MCCB Frame Type
Reference [`] Reference [`]
CVS/NSX - 100/160 ME LV429212 11930 LV429213 12890
CVS/NSX - 100/160 MH LV429210  15330 LV429211 16935
CVS/NSX - 250 MH LV431535 17815 LV431536 18215
CVS/NSX - 400/630 MB LV432455 44130 LV432456 45955

ME Type MH Type MB Type


• Sensitivity - 300mA (fixed) • Sensitivity - adjustable • Sensitivity - adjustable
• Instantaneous time delay • 30mA - 300mA-1A-3A-10A • 300mA-1A-3A-10A -30A
• Fixed < 40ms • Instantaneous time delay(ms) • Instantaneous time delay (ms)
• 0 - 60 (2) - 150 (2) - 310 (2) • 0 - 60 - 150 - 310
(1) Vigi 3P modules may also be used on 3P circuit breaker used for single phase or two phase protection
(2) If the sensitivity is set to 30mA, there is no time delay, whatever the time delay setting

Insulation monitoring module for EasyPact CVS/ Compact


NSX Range Moulded Case Circuit Breakers

• Settings: 100 - 200 - 500 - 1000mA


• Indication by Red LED without tripping the circuit breaker
• Option for installing auxiliary contact for remote indication/tripping

Three Pole Unit MRP Four Pole Unit MRP


Description
Reference [`] Reference [`]
CVS/NSX 100- 250A
220 to 440V AC LV429459 14260 LV429460 15325
Connection for a 4P insulation monitoring module on a 3P breaker - - LV429214 5885
CVS/NSX 400- 630A
220 to 440V AC LV432659 22585 LV432660 25205
Connection for a 4P insulation monitoring module on a 3P breaker - - LV432457 16605

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 53
Vigirex Earth Leakage Protection Relay

Earth Leakage Protection is obtained by:


• Installing a Micrologic 7.0.A control unit (Compact NS800 - 3200A/ Masterpact NT/NW ACB)
• Using Vigirex Relays and separate Toroids or Rectangular Sensors

Vigirex Relays

Vigirex Relays along with Vigirex Sensors, may be may be used to add external Earth Leakage Protection to Circuit Breakers
• Sensitivity Adjustments from 30mA to 30A and time delay settings from (0-4.5 seconds)
• Closed Toroid up to 630A (30 to 300mm in diameter), Split Toroid up to 250A (46 to 110mm in diameter) or
• Rectangular sensor up to 3200A
• 400Hz Distribution System
Note: For further details, please contact our nearest Sales Office.

Control Voltage Din rail mount Unit MRP Front panel mount Unit MRP
Type
Reference [`] Reference [`]
RH10 with local manual fault reset 220/240VAC 56130 56230
9425 10355
Sensitivity=0.03A 380/415VAC 56140 56240
RH99 with local manual fault reset 220/240VAC 56173 14245 56273 15420
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC 56174 15710 56274 16195
RH197P with local manual or automatic fault reset 220/240VAC - 56507* 17440
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC - 56508* 18315
RH197P with local manual or automatic fault reset 220/240VAC - 56512** 17615
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC - 56513** 18490

* alarm at 50% of fault threshold


** alarm at 100% of fault threshold

Vigirex Sensors

Ie(A) Rated Unit MRP


Type Inside Diameter (mm) Reference
Operational Current [`]
TA30 65 30 50437 6005
PA50 85 50 50438 8375
IA80 160 80 50439 9975
MA120 250 120 50440 12000
SA200 400 200 50441 18645
GA300 630 300 50442 41410

Note: For vigirex relay with monitoring and communication facility, contact nearest sales office.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 54
Compact- INS & INV Switch Disconnectors

For Low Voltage Circuit Control and Isolation - Incomers for Distribution Boards
• Conforms to IEC 60947-3/IS 13947 - 3
• Rated operational voltages 500V/690V
• Range 40A to 2500A
• Rated operational current @ AC 23A
• No deration upto 60° C
• Positive contact indication
• Common accessories with Compact NSX/single auxillary contact
• Making capacity enhanced with Compact NSX upstream

Pole Description Rated Operational Current Reference Unit LP [`]

Interpact Range of Switch Disconnectors


40 A AC-23A 28900 3960
63 A AC-23A 28902 4790
100 A AC-23A 28908 5640
125 A AC-23A 28910 6150
160 A AC-23A 28912 6850
3-Pole
200 A AC-23A 31102 11910
250 A AC-23A 31106 12580
320 A AC-23A 31108 20480
400 A AC-23A 31110 23080
630 A AC-23A 31114 23740
40 A AC-23A 28901 4420
63 A AC-23A 28903 5240
100 A AC-23A 28909 6150
125 A AC-23A 28911 6860
160 A AC-23A 28913 7570
4-Pole
200 A AC-23A 31103 13290
250 A AC-23A 31107 13960
320 A AC-23A 31109 23720
400 A AC-23A 31111 24490
630 A AC-23A 31115 27450
lnterpact Changeover Systems (Complete Assembly)
100 A AC-23A 31140 35250
160 A AC-23A 31144 38370
200 A AC-23A 31142 42200
3-Pole 250 A AC-23A 31146 43375
320 A AC-23A 31148 71730
400 A AC-23A 31150 76585
630 A AC-23A 31154 77910
100 A AC-23A 31141 40205
160 A AC-23A 31145 43975
200 A AC-23A 31143 49795
4-Pole 250 A AC-23A 31147 51525
320 A AC-23A 31149 78240
400 A AC-23A 31151 80775
630 A AC-23A 31155 92475

Description Reference Unit LP [`]

Accessories
Optional front extended rotary handle INS 250 - black handle (Switch Disconnector) LV431050 3495
Optional front extended rotary handle INS 320..630 - black handle (Switch Disconnector) 31052 4945
Optional front extended rotary handle INS 40..160 - black handle (Switch Disconnector) LV428941 1775
6 phase separators - INS100..160 28959 775
6 phase separators - INS250 29329 685
6 phase separators - INS400..630 LV432570 685

For
Please
details
contact
on non-standard
Customer Care
references,
Center for
technical
Stockable
parameters,
and Non stockable
stockable and
status
non-stockable
of references.
status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 55
SDF Switch Disconnector Fuse units

Fuse solutions from the world leader in electrical distribution


• The most complete fuse device offer in single and double break - switch disconnector fuses, fuse switch
disconnectors and disconnector fuses
• Double break and Single break offer.
• Short-circuit and overload protection
• Isolation
• On-load switching of circuits

Range Details: NX range Switch Disconnector Fuse


• 32A to 630A TP, TPN & FP version suitable for DIN/BS fuses.
• 4 break and 8 arcing zones
• IP20 Fuse protection cover is standard.
Range Details: ISFT range Fuse Switch Disconnector
• 100A to 630A TP, version suitable for DIN fuses.
• Single breaking and direct connection to busbars
• isolation with positive contact indication when the fuse-carrier assembly is in the open position (OFF).
Range Details: ISFL range Vertical Fuse Switch Disconnector
• 160A to 1250A TP, version suitable for DIN fuses.
• Single breaking and direct connection to busbars
• Two versions i.e Single pole or Three pole operation

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 56
Fupact Switch Disconnector Fuse units

• Complete Range from 32 to 630A in TP, TP+N & FP version suitable for
DIN/BS fuses.
• 4 breaks and 8 arcing points
• IP20 Fuse Protection Cover is standard
• Higher Mechanical and Electrical life.
Without Enclosure
Rated Operational DIN Type Unit LP BS Type Unit LP
Poles Description
Current Reference [`] Reference [`]
32 A 3P + N NX032TPNDI  2190 NX032TPNBS 2160
63 A 3P + N NX063TPNDI  2890 NX063TPNBS 2870
80 A 3P + N NX080TPNDI 5470 NX080TPNBS 5210
3P NX100TPXDI 6040
100 A 3P + N NX100TPNDI  6270 NX100TPNBS 6220
4P NX100FPXDI 6520
3P NX125TPXDI  7040
125 A 3P + N NX125TPNDI  7690 NX125TPNBS 7610
4P NX125FPXDI 8650
3P NX160TPXDI 7760
160 A 3P + N NX160TPNDI  8380 NX160TPNBS 7890
4P NX160FPXDI 9660
3P NX200TPXDI 10270
200 A 3P + N NX200TPNDI  10770 NX200TPNBS 9470
4P NX200FPXDI 12050
3P NX250TPXDI 12590
250 A 3P + N NX250TPNDI  12960 NX250TPNBS 12440
4P NX250FPXDI 15250
3P NX315TPXDI 15820
315 A 3P + N NX315TPNDI  16050 NX315TPNBS 15790
4P NX315FPXDI 17800
3P NX400TPXDI 21140
400 A 3P + N NX400TPNDI  21940 NX400TPNBS 20740
4P NX400FPXDI 26440
3P NX630TPXDI 31210
630 A 3P + N NX630TPNDI  31920 NX630TPNBS 31600
4P NX630FPXDI 35600

Accessories/Spares

Description Reference Unit LP [`]

NX032/NX063/NX080
Auxiliary contact for Fupact NXAA11  445
Fuse holder for DIN NX032...NX080 NXHD1 210
Handle operating mechanism (HOM) NX032...NX080 NXR1 395
HOM shaft for NX/32/63/80 NXRS1 210
NX100/NX125/NX160
Auxiliary contact for Fupact NXBA11  515
Fuse holder DIN for BS type NX100...NX160 NXHB21 190
Fuse holder DIN for NX100...NX160 NXHD21 210
Handle operating mechanism NX100...NX160 NXR2  755
Shaft for HOM for NX100...NX160 NXRS2 210
NX200
Auxiliary contact for Fupact NXBA11  515
Fuse holder for BS type NX200 NXHB22 200
Fuse holder for DIN NX200 NXHD22 230
Handle operating mechanism NX200 NXR2  755
Shaft for HOM for NX200 NXRS2A 260
NX250/315/400
Auxiliary contact for Fupact NXBA11  515
Handle operating mechanism for NX250...NX400 NXR3 785
Shaft for HOM for NX250…NX400 NXRS3 260
NX630
Auxiliary contact for Fupact NXBA11  515
Handle operating mechanism for NX630 NXR4 835
Shaft for HOM for NX630 NXRS4 260
Note: For other versions please contact our nearest Sales Office.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 57
Fupact - Type 2 Co-ordination Table With Fuse

EasyPact TVS DOL (Type 2 Co-ordination with Fuse)


• Standard: IEC 60947-4-1
• Fuses: Cooper Bussmann
• Iq (A): 50KA
• Ue: 415Vac / 50Hz
• Contactor Coil: Type M5 (220 Vac/ 50 Hz)

Motor Output FLC SDF (NX Range) Contactor Thermal Overload Relay
Fuse Rating
KW HP I(A) Type Fuse Type Type AC3 (A) Type Range (A)
(A)
0.37 0.5 1 NX32 6NHG000B 6 LC1E09 9 LRE06 1.0 - 1.6
0.55 0.75 1.5 NX32 6NHG000B 6 LC1E09 9 LRE06 1.0 - 1.6
0.75 1 2 NX32 6NHG000B 6 LC1E09 9 LRE07 1.6 - 2.5
1.5 2 3.5 NX32 16NHG000B 16 LC1E09 9 LRE08 2.5 - 4.0
2.2 3 5 NX32 16NHG000B 16 LC1E09 9 LRE10 4.0 - 6.0
3 4 6.8 NX32 20NHG000B 20 LC1E09 9 LRE12 5.5 - 8.0
4 5.5 8.4 NX32 20NHG000B 20 LC1E09 9 LRE14 7.0 - 10
5.5 7.5 11.2 NX32 25NHG000B 25 LC1E12 12 LRE16 9.0 - 13
7.5 10 14 NX63 40NHG000B 40 LC1E18 25 LRE21 12.0 - 18
9 12 18 NX63 50NHG000B 50 LC1E25 25 LRE22 16 - 24
11 15 21 NX63 50NHG000B 50 LC1E32 32 LRE22 16 - 24
15 20 28.5 NX63 63NHG000B 63 LC1E32 40 LRE32 23 - 32
18.5 25 34 NX80 80NHG000B 80 LC1E40 40 LRE355 30 - 40
22 30 42 NX80 80NHG000B 80 LC1E50 50 LRE357 37 - 50
30 40 57 NX100 100NHG000B 100 LC1E65 65 LRE359 48- 65
37 50 70 NX125 125NHG00B 125 LC1E80 80 LRE363 63- 80
45 60 81 NX160 160NHG00B 160 LC1E95 95 LRE365 80- 104
56 75 100 NX160 160NHG00B 160 LC1E120 115 LRE482 84- 135
80 107 138 NX250 250NHG1B 250 LC1E160 150 LRE483 124- 198
90 120 165 NX250 250NHG1B 250 LC1E160 160 LRE483 124- 198
100 135 182 NX315 315NHG2B 315 LC1E200 200 LRE483 124- 198
110 150 196 NX315 315NHG2B 315 LC1E200 200 LRE483 124- 198
132 177 240 NX400 355NHG2B 355 LC1E250 250 LRE485 174- 279
160 215 285 NX400 400NHG2B 400 LC1E300 300 LRE486 208- 333

EasyPact TVS Star Delta (Type 2 Co-ordination with Fuse)


• Standard: IEC 60947-4-1
• Fuses: Cooper Bussmann
• Iq (A): 50KA
• Ue: 415Vac / 50Hz
• Contactor Coil: Type M5 (220 Vac/ 50 Hz)

Thermal Overload
Motor Output FLC SDF (NX Range) Contactor
Relay
Main /
I Line I phase Fuse Star Range
KW HP Type Fuse Type AC3- A Delta Con- AC3- A Type
(A) (A) Rating (A) Contactor (A)
tactor
1.5 2 4 2.3 NX32 10NHC00G 10 LC1E09 9 LC1E09 9 LRE07 1.6-2.5
2.2 3 5 3 NX32 16NHC00G 16 LC1E09 9 LC1E09 9 LRE08 2.5-4
3 4 7 4 NX32 16NHC00G 16 LC1E09 9 LC1E09 9 LRE08 2.5-4
4 5.3 9 5 NX32 20NHC00G 20 LC1E09 9 LC1E09 9 LRE10 4-6
5.5 7.5 10 6 NX32 20NHC00G 20 LC1E09 9 LC1E09 9 LRE12 5.5-8
7.5 10 16 9 NX32 32NHC00G 32 LC1E09 9 LC1E09 9 LRE14 7-10
9 12 17 10 NX32 32NHC00G 32 LC1E09 9 LC1E12 9 LRE14 7-10
11 15 21 12 NX63 50NHC00G 50 LC1E12 12 LC1E12 12 LRE16 9-13
15 20 28 16 NX63 63NHC00G 63 LC1E18 18 LC1E18 18 LRE21 12-18
22 30 42 24 NX80 80NHC00G 80 LC1E25 25 LC1E25 25 LRE32 23-32
30 40 57 33 NX125 100NHG00B 100 LC1E40 40 LC1E40 40 LRE355 30-40
45 60 81 47 NX125 125NHG00B 125 LC1E40 40 LC1E50 50 LRE357 37-50
55 75 100 58 NX125 125NHG00B 125 LC1E40 40 LC1E65 65 LRE359 48-65
80 107 139 80 NX200 200NHG1B 200 LC1E80 80 LC1E80 80 LRE363 63-80
110 150 196 113 NX315 315NHG2B 315 LC1E300 300 LC1E300 300 LRE482 84~135
160 215 286 165 NX400 355NHG2B 355 LC1E300 300 LC1E300 300 LRE483 124~198
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 58
The Benchmark for Power Circuit Breakers around the world

Masterpact NT/NW
LV power circuit breakers 630 to 6300 A

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
Network Protection Supervision Compact
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 59
Masterpact NT and NW

The Benchmark For Power Circuit Breakers


Around The World

Ethernet ready Masterpact NT and NW breakers, setting the standard for performance, safety, connectivity and
built-in metering; all in optimized frame sizes
• Ethernet based monitoring, control, alarm notification for energy, asset and network management
• Built-in energy metering with combined accuracy class of 2% for improved energy efficiency

3
• Masterpact is suitable for heavy duty applications

sizes

Building Energy Industry Datacenter


& Infrastructure
• Masterpact is an answer to specific applications:
Micrologic E Micrologic P Micrologic H
• 1000V for mining applications
Masterpact NT 630 to 1600A
• Direct current networks
• Corrosion protection
• Switch disconnectors and earthing switches

Range Details:NW 800 to 4000A


Masterpact
• 630A to 6300A
• Breaking Capacity upto 150kA
• Fixed, Draw out type
• Flexible terminal orientation enables horizontal or vertical alignment changes in the field*

Masterpact NW 4000 to 6300A

*Not Applicable for 4000A and 6300A


For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 60
Micrologic trip system Overview of functions

Micrologic name codes

X: type of protection
n 2 for basic protection
n 5 for selective protection
n 6 for selective + earth-fault protection
n 7 for selective + earth-leakage protection.
Y: control-unit generation
Identification of the control-unit generation.
“0” signifies the first generation.
Z: type of measurement
n E for” Energy”
n P for “power meter”
n H for “harmonic meter”.

Measurements and programmable protection

n I1, I2, I3, IN, Iearth-fault, Iearth-leakage and maximeter for these measurements
n fault indications
n settings in amperes and in seconds.
n calculates the current demand value P: E + power meter + programmable protection
n “Quickview” function for the automatic cyclical n measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, Vpeak, Apeak, power
display of the most useful values (as standard factor and maximeters and minimeters
or by selection). n IDMTL long-time protection, minimum and maximum voltage and frequency,
voltage and current imbalance, phase sequence, reverse power
n load shedding and reconnection depending on power or current
measurements of interrupted currents, differentiated fault indications,
n maintenance indications, H: P + harmonics
event histories and
time-stamping, etc. n power quality: fundamentals, distortion, amplitude and
phase of harmonics up to the 31st order
n waveform capture after fault, alarm or on request
n enhanced alarm programming: thresholds and actions.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 61
Micrologic Trip unit
Energy efficiency, now within your reach

DB101124

DB101124
DB127408
Micrologic 6.0 E

100 %

40 %

menu

long time
alarm

short time

ground fault

E ‘Energy’ P ‘Power’ H ‘Harmonics’

Current , maximeter ● ● ●
Measurement

Voltage, PF, Power,


demand, energy ● ● ●
Cos-φ, frequency, per phase,
advanced protection ● ●
Harmonics, waveform capture,
enhanced alarms ●
2 (L, I) 2.0 E
Protection

5 (L, S, I) 5.0 E 5.0 P 5.0 H

6 (L, S, I,G) 6.0 E 6.0 P 6.0 H

7 (L, S, I, V) 7.0 P 7.0 H

Solar PVDC ACB Offer


Masterpact NW HADCD - PV switch disconnectors
• 2000A and 4000A @ 1000V DC
• Short Circuit Withstand Capacity upto 85kA 1sec
• Fixed and Draw out type
• High Mechanical and Electrical life

Safer photovolatic Energy Generation

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 62
ATS Kit

Suitable for Masterpact NT/ NW ACB


This Kit comprises of :
Adaptation fixture & set of two cables for mechanical interlocking
IVE unit for Electrical Interlocking
ACP control Plate
UA/BA controller
*Note: For ATS with Masterpact NT/NW ACB, order 2 nos. of ACB’s with ready to close PF contact + 1 no. ATS Kit

ACP Unit IVE Unit Controller Mechanical inetrlocking using cable

Unit MRP
Description Reference
[`]
ATS Kit for Masterpact NT EDO type with BA 415VAC controller INA_NTDOB4 119875

ATS Kit for Masterpact NT EDO type with UA 415VAC controller INA_NTDOU4 137520

ATS Kit for Masterpact NW EDO type with BA 415VAC controller INA_NWDOB4  129875

ATS Kit for Masterpact NW EDO type with UA 415VAC controller INA_NWDOU4  165020

**ATS Kit with for Fixed Breaker and BA controller with 240VAC, contact our customer care

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 63
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 64
The easy choice for reliable performance

EasyPact MVS
LV power circuit breakers and switch
disconnectors from 800 to 4000 A

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 65
EasyPact MVS

The easy choice for reliable performance

• Thermal memory ensures safe tripping in case of consecutive faults


• In-built ZSI feature facilitates intelligent discrimination and enhances installation life
• Mechanical ready to close features checks all safety parameters before closing for enhanced safety
• Trip unit with built in current & voltage metering for easy access to important electrical parameters
• Best in class break time of 25ms creates lower stress on installation
• Pollution degree 4 allows the breaker to operate in harsh environments
• LED bargraph ensures easy access to % phase wise loading information
• Ap protection feature standard in all trip units

Range Details:
• Single frame for 800A to 4000A
• Fixed, Draw out type
• Entire Range Icu=Ics=Icw=50kA for 1sec @440V
• Suitability for applications up to 690 V
• Flexible terminal orientation enables horizontal or vertical alignment changes in the field*

*Not possible for 4000A


For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 66
ET/ETA/ETV Trip System

A step towards intelligent Electrical Distribution Network

ET TRIP ETA Trip ETV TRIP


UNIT Unit UNIT
Current Metering

Voltage Metering

ZSI
Features
% Loading Bar Graph for each
phase
Thermal Memory

Last 10 Trip History

2 (L, I) 2L 2A 2V
Protection
6 (L,S,I,G) 6G 6A 6V

NEW
EasyPact ACB CommunicationModule

Connect Control Manage

Make Communication architecture EasyPact MVS communication module


affordable and Easy to maintain connect and control ACB on Modbus
Communication architecture.
• Connect, Control & Manage three
ACBs from one communication
module having RS485 port with
Modbus RTU protocol.
a. Connect breaker ON/OFF status
(OF) Breaker trip status (SDE),
ready to close status (PF)
b. Control remote open/close of air
circuit breakers.
c. Manage one analog input (4-20mA)

Reference no Material description LP


MVS21430 EasyPact MVS Communication module .... EasyCom 10,300

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 67
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚C
• Zone Selective Interlocking
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• Icu=Ics=Icw(1sec) = 50kA @ 440V AC

Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit LP Unit LP Unit LP Unit LP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW6L 171140 MVS08N3NW6L 215640 MVS08N4MW6L 214800 MVS08N4NW6L 259300
1000 MVS10N3MW6L 179780 MVS10N3NW6L 224280 MVS10N4MW6L 225040 MVS10N4NW6L 269540
1250 MVS12N3MW6L 200180 MVS12N3NW6L 244680 MVS12N4MW6L 249250 MVS12N4NW6L 293750
1600 MVS16N3MW6L 227510 MVS16N3NW6L 272010 MVS16N4MW6L 277610 MVS16N4NW6L 322110
2000 MVS20N3MW6L 276560 MVS20N3NW6L 321060 MVS20N4MW6L 339650 MVS20N4NW6L 384150
2500 MVS25N3MW6L 341920 MVS25N3NW6L 386420 MVS25N4MW6L 415480 MVS25N4NW6L 459980
3200 MVS32N3MW6L 417560 MVS32N3NW6L 462060 MVS32N4MW6L 512000 MVS32N4NW6L 556500
4000 MVS40N3MW6L 510700 MVS40N3NW6L 555200 MVS40N4MW6L 649500 MVS40N4NW6L 694000

EasyPact MVS Draw out ACB


LP changes for product
ACB variants Configuration w.r.t. ACB having How to arrive at new reference number*
ET6G trip unit.

Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MW0D

ACB with ET6A trip unit Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For ACB
Add `9200
(LCD display with Current Metering) reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MW6A

ACB with ET6V trip unit


Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For ACB
(LCD display with Current Metering & Add `21200
reference with ET6V trip unit replace 6L by 6V i.e MVS08N3MW6V
Voltage Metering and Last 10 Trip History)

*- Same Philosophy for 3 Pole/ 4 Pole and Manual/ Electrical References

Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).

• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX) (Voltage
ratings to be specified by customer & duty filled in ACB Order form)
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 68
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚C
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• ET2L provides Overload & Short-circuit protections
• Icu=Ics=Icw(1sec) = 50kA @ 440V AC

Draw-out Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit LP Unit LP Unit LP Unit LP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW2L 163740 MVS08N3NW2L 208240 MVS08N4MW2L 207400 MVS08N4NW2L 251900
1000 MVS10N3MW2L 172380 MVS10N3NW2L 216880 MVS10N4MW2L 217640 MVS10N4NW2L 262140
1250 MVS12N3MW2L 192780 MVS12N3NW2L 237280 MVS12N4MW2L 241850 MVS12N4NW2L 286350
1600 MVS16N3MW2L 220110 MVS16N3NW2L 264610 MVS16N4MW2L 270210 MVS16N4NW2L 314710
2000 MVS20N3MW2L 269160 MVS20N3NW2L 313660 MVS20N4MW2L 332250 MVS20N4NW2L 376750
2500 MVS25N3MW2L 334520 MVS25N3NW2L 379020 MVS25N4MW2L 408080 MVS25N4NW2L 452580
3200 MVS32N3MW2L 410160 MVS32N3NW2L 454660 MVS32N4MW2L 504600 MVS32N4NW2L 549100
4000 MVS40N3MW2L 503300 MVS40N3NW2L 547800 MVS40N4MW2L 642100 MVS40N4NW2L 686600

EasyPact MVS Draw out ACB


LP changes for product
ACB variants Configuration w.r.t. ACB having How to arrive at new reference number*
ET2L trip unit.

ACB with ET2A trip unit (LCD display with Example : ACB reference with ET2L trip unit - MVS08N3MW2L. For ACB
Add `4600
Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MW2A

ACB with ET2V trip unit (LCD display with


Example : ACB reference with ET2L trip unit - MVS08N3MW2L. For ACB
Current Metering & Voltage Metering and Add `13800
reference with ET2V trip unit replace 2L by 2V i.e MVS08N3MW2V
Last 10 Trip History)

AC* Same Philosophy for 3 Pole/ 4 Pole and Manual/ Electrical References

Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).

• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX).
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 69
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚ C
• Zone Selective Interlocking
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• Icu=Ics=Icw(1sec) =50kA @ 440V AC

Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)

Rating 3P Fix Manual Unit LP 3P Fix Electrical Unit LP 4P Fix Manual Unit LP 4P Fix Electrical Unit LP
in (A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF6L 127610 MVS08N3NF6L 172110 MVS08N4MF6L 162250 MVS08N4NF6L 206750
1000 MVS10N3MF6L 139690 MVS10N3NF6L 184190 MVS10N4MF6L 176210 MVS10N4NF6L 220710
1250 MVS12N3MF6L 160550 MVS12N3NF6L 205050 MVS12N4MF6L 200590 MVS12N4NF6L 245090
1600 MVS16N3MF6L 178220 MVS16N3NF6L 222720 MVS16N4MF6L 230370 MVS16N4NF6L 274870
2000 MVS20N3MF6L 208240 MVS20N3NF6L 252740 MVS20N4MF6L 272140 MVS20N4NF6L 316640
2500 MVS25N3MF6L 253870 MVS25N3NF6L 298370 MVS25N4MF6L 320740 MVS25N4NF6L 365240
3200 MVS32N3MF6L 363400 MVS32N3NF6L 407900 MVS32N4MF6L 448370 MVS32N4NF6L 492870
4000 MVS40N3MF6L 447520 MVS40N3NF6L 492020 MVS40N4MF6L 561050 MVS40N4NF6L 605550

EasyPact MVS Fix ACB


LP changes for product
ACB variants Configuration w.r.t. ACB having How to arrive at new reference number*
ET6G trip unit.

Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MF0D

ACB with ET6A trip unit (LCD display Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For ACB
Add `9200
with Current Metering) reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MF6A

ACB with ET6V trip unit


Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For ACB
(LCD display with Current Metering & Add `21200
reference with ET6V trip unit replace 6L by 6V i.e MVS08N3MF6V
Voltage Metering and Last 10 Trip History)

* Same Philosophy for 3 Pole/ 4 Pole and Manual/ Electrical References

Note:
All Fix type circuit breakers will be supplied with:
(i) horizontal / vertical terminal
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) door sealing frame- Escutcheon (CDP).

• All switch disconnectors are without protection


• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX).
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 70
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50° C
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• Icu=Ics=Icw(1sec) =50kA @ 440V AC

Fixed Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
Rating in 3P Fix Manual Unit LP 3P Fix Electrical Unit LP 4P Fix Manual Unit LP 4P Fix Electrical Unit LP
(A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF2L 120210 MVS08N3NF2L 164710 MVS08N4MF2L 154850 MVS08N4NF2L 199350
1000 MVS10N3MF2L 132290 MVS10N3NF2L 176790 MVS10N4MF2L 168810 MVS10N4NF2L 213310
1250 MVS12N3MF2L 153150 MVS12N3NF2L 197650 MVS12N4MF2L 193190 MVS12N4NF2L 237690
1600 MVS16N3MF2L 170820 MVS16N3NF2L 215320 MVS16N4MF2L 222970 MVS16N4NF2L 267470
2000 MVS20N3MF2L 200840 MVS20N3NF2L 245340 MVS20N4MF2L 264740 MVS20N4NF2L 309240
2500 MVS25N3MF2L 246470 MVS25N3NF2L 290970 MVS25N4MF2L 313340 MVS25N4NF2L 357840
3200 MVS32N3MF2L 356000 MVS32N3NF2L 400500 MVS32N4MF2L 440970 MVS32N4NF2L 485470
4000 MVS40N3MF2L 440120 MVS40N3NF2L 484620 MVS40N4MF2L 553650 MVS40N4NF2L 598150

EasyPact MVS Fix ACB

LP changes for product configura-


ACB variants How to arrive at new reference number
tion w.r.t. ACB having ET2L trip unit.

ACB with ET2A trip unit (LCD display Example : ACB reference with ET2L trip unit - MVS08N3MF2L. For ACB
Add `4600
with Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MF2A

ACB with ET2V trip unit (LCD display


Example : ACB reference with ET2L trip unit - MVS08N3MF2L. For ACB
with Current Metering & Voltage Add `13800
reference with ET2V trip unit replace 2L by 2V i.e MVS08N3MF2V
Metering and Last 10 Trip History)

* Same Philosophy for 3 Pole/ 4 Pole and Manual/ Electrical References

Note:

All Fix type circuit breakers will be supplied with:


( i) horizontal / vertical terminal
( ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) door sealing frame- Escutcheon (CDP).

• All switch disconnectors are without protection


• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX).
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 71
EasyPact MVS Accessories

Pole Description Rated Operational Current Reference Unit LP [`]

Gear Motor (MCH)


100/130 V 47893
AC 50/60 Hz 200/240 V 47894 
380/415 V 47896
24/30 V 47888 35800
48/60 V 47889
DC
100/125 V 47890
200/250 V 47891
Closing Release (XF)
24/30 V DC 33659
48/60 V DC 33660
AC 50/60 Hz DC 100/130 V AC/DC MVS15511  5100
200/250 V AC/DC MVS15512 
380/480 V AC MVS15513
Opening Release (MX)
24/30 V DC, 24 V AC 33659
48/60 V DC, 48 V AC 33660
AC 50/60 Hz DC 100/130 V AC/DC 33661  5100
200/250 V AC/DC 33662 
380/480 V AC 33664 

Terminal Block
For drawout circuit breaker 47849 210
Under Voltage Release (MN)
24/30 V DC, 24 V AC 33668
48/60 V DC, 48 V AC 33669
AC 50/60 Hz DC 100/130 V AC/DC 33670  5200
200/250 V AC/DC 33671 
380/480 V AC 33673 
MN Delay Unit
48/60 V AC/DC 33680
100/130 V AC/DC 33681
Rr (adjustable) 7600
200/250 V AC/DC 33682
AC 50/60 Hz DC
380/480 V AC/DC 33683
100/130 V AC/DC 33684
R (non-adjustable) 7100
200/250 V AC/DC 33685 
ON/OFF Indication Contacts (Additional OF contact)
1 additional block of 4 contacts 47887 4600
Door Interlock (VPECD)/1 part
On right hand side of chassis 47914  2500
Operation Counter
Operation Counter CDM 48535 7150

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 72
EasyPact SPS

Standard Protection System for your electrical


distribution network

800-1600A
ET2.0 ET6G
Trip System Trip System

Microprocessor Base Trip Units

Schneider Electric Global specialist in the field of ACBs and


MCCBs, introduces EasyPact SPS range of ACBs
• Single Frame size from 800-1600A
• ASIC Based Microprocessor trip unit with OL, SC & EF protection features, which offer
fastest short circuit tripping time in its class
• 25 ms short circuit tripping time ensure low let through energy increase the longevity of
an electrical distribution network, cables and equipment
• Offer highest standards of safety for operator as well as
Electrical distribution network
• Pollution category –III along with modular technology ensure high operating cycles
without maintenance
• Simple to choose and easy to install

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 73
EasyPact SPS Draw-out type Circuit breakers and
Switch Disconnectors 800-1600A

• All Easypact SPS Air Circuit Breakers are equipped with terminal adaptors
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• Fully rated neutral with inbuilt protection
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• ET2B provides Overload & Short-circuit protections
• Short circuit breaking capacity 50kA @ 440V AC

Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW6L 130880 SPS08F3PEW6L 168780 SPS08F4PMW6L 164130 SPS08F4PEW6L 202030
1000 SPS10F3PMW6L 137130 SPS10F3PEW6L 175030 SPS10F4PMW6L 173620 SPS10F4PEW6L 211520
1250 SPS12F3PMW6L 153380 SPS12F3PEW6L 191280 SPS12F4PMW6L 195630 SPS12F4PEW6L 233530
1600 SPS16F3PMW6L 173040 SPS16F3PEW6L 210940 SPS16F4PMW6L 221450 SPS16F4PEW6L 259350

Draw-out Type circuit breaker with Microprocessor based ET2B Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW2B 129080 SPS08F3PEW2B 166980 SPS08F4PMW2B 162330 SPS08F4PEW2B 200230
1000 SPS10F3PMW2B 135330 SPS10F3PEW2B 173230 SPS10F4PMW2B 171820 SPS10F4PEW2B 209720
1250 SPS12F3PMW2B 151580 SPS12F3PEW2B 189480 SPS12F4PMW2B 193830 SPS12F4PEW2B 231730
1600 SPS16F3PMW2B 171240 SPS16F3PEW2B 209140 SPS16F4PMW2B 219650 SPS16F4PEW2B 257550

Draw-out Type switch disconnector without protection


3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW0D 116680 SPS08F3PEW0D 154580 SPS08F4PMW0D 149930 SPS08F4PEW0D 187830
1000 SPS10F3PMW0D 122930 SPS10F3PEW0D 160830 SPS10F4PMW0D 159420 SPS10F4PEW0D 197320
1250 SPS12F3PMW0D 139180 SPS12F3PEW0D 177080 SPS12F4PMW0D 181430 SPS12F4PEW0D 219330
1600 SPS16F3PMW0D 158840 SPS16F3PEW0D 196740 SPS16F4PMW0D 207250 SPS16F4PEW0D 245150

Note:
All draw-out type circuit breakers will be supplied with:
(i) Vertical-vertical terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).

• All switch disconnectors are without protection


• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) and shunt release (MX).
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 74
EasyPact SPS Fixed type Circuit breakers and
Switch Disconnectors 800-1600A

• All Easypact SPS Air Circuit Breakers are equipped with terminal adaptors
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• Fully rated neutral with inbuilt protection
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• ET2B provides Overload & Short-circuit protections
• Short circuit breaking capacity 50kA @ 440V AC

Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit
3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF6L 100540 SPS08F3PEF6L 138440 SPS08F4PMF6L 122230 SPS08F4PEF6L 160130
1000 SPS10F3PMF6L 105850 SPS10F3PEF6L 143750 SPS10F4PMF6L 131240 SPS10F4PEF6L 169140
1250 SPS12F3PMF6L 122040 SPS12F3PEF6L 159940 SPS12F4PMF6L 152260 SPS12F4PEF6L 190160
1600 SPS16F3PMF6L 141320 SPS16F3PEF6L 179220 SPS16F4PMF6L 174060 SPS16F4PEF6L 211960

Fixed Type circuit breaker with Microprocessor based ET2B Trip Unit
3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF2B 98740 SPS08F3PEF2B 136640 SPS08F4PMF2B 120430 SPS08F4PEF2B 158330
1000 SPS10F3PMF2B 104050 SPS10F3PEF2B 141950 SPS10F4PMF2B 129440 SPS10F4PEF2B 167340
1250 SPS12F3PMF2B 120240 SPS12F3PEF2B 158140 SPS12F4PMF2B 150460 SPS12F4PEF2B 188360
1600 SPS16F3PMF2B 139520 SPS16F3PEF2B 177420 SPS16F4PMF2B 172260 SPS16F4PEF2B 210160

Fixed Type switch disconnector without protection


3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF0D 86340 SPS08F3PEF0D 124240 SPS08F4PMF0D 108030 SPS08F4PEF0D 145930
1000 SPS10F3PMF0D 91650 SPS10F3PEF0D 129550 SPS10F4PMF0D 117040 SPS10F4PEF0D 154940
1250 SPS12F3PMF0D 107840 SPS12F3PEF0D 145740 SPS12F4PMF0D 138060 SPS12F4PEF0D 175960
1600 SPS16F3PMF0D 127120 SPS16F3PEF0D 165020 SPS16F4PMF0D 159860 SPS16F4PEF0D 197760

Note: All Fixed type circuit breakers will be supplied with: (i) Vertical-vertical terminations. (ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
All switch disconnectors are without protection | All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) and shunt release
(MX). | External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price. | Any other accessories are optional at extra price.

Accessories

Pole Description Rated Operational Current Reference Unit LP [`]

Gear Motor (MCH)


100/130 V 33176 36000
AC 50/60 Hz 200/240 V 33177 36000
277/415 V 33179 36000
24/30 V 33185 36000
48/60 V 33186 36000
DC
100/125 V 33187 36000
200/250 V 33188 36000
Terminal Block
For Fixed circuit breaker 47074 190
For Drawout circuit breaker 33098 215
ON/OFF Indication contacts (OF) 1Part
Changeover contact 6A 240V 47076 1050
Ready to close contact
Changeover contact 5A 240V 47080 2400
Door interlock (VPECD)/1 part
Right side of chassis 33172 2200

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 75
“Ecodial Advance Calculation 4” sizing software

The reference tool for


electrical installations
compliant and
performant

To download Ecodial Advance Calculation Version:


https://hto.power.schneider-electric.com/ecodialadvancecalculation/#/homepage

To download Ecodial plugin for AutoCAD Version 1.3:


http://hto.power.schneider-electric.com/EcodialPlugin/#/
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 76
Ecodial Advance Calculation 4

Unequalled For you


Time savings and increased productivity

benefits > User-friendly and intuitive software.


> Verification of electrical network consistency prior to calculation of solutions.
> Errors reported and identified on the single-line diagram.
> Calculation reports and information immediately usable (deliverables ready to
use: single Word document, printable and convertible to PDF).

High added value level


> Consideration of the installation operating modes and the need for continuity
of supply.
> Consistency of choices between calculated switchgear and proposed
equipment (for example: compatibility between switchgear and switchboard or
Canalis).
> Harmonisation of the protection schedule:
> Ecodial Advance Calculation 4 lets you easily customise the protection choices
out of the alternatives.

Enhanced expert image


> Compliance with calculation standards: compliance with the CENELEC TR50480
technical report.
> Compliance with installation standards: non-conformities are automatically
reported.
> Compliance with product standards: all recommended Schneider Electric
products comply with applicable standards.
> Guarantee of having the most up-to-date offers.
> Complete study file: automatic generation of design notes and cable and
protection schedule.

For your customers


Shorter design times Installation conforming to of the existing
> No time wasted in applicable standards installation.
calculation, search for > Complete compliance Optimised latest
current products with calculation and generation solution
conforming to standards, installation standards. > Installation operating
processing of data and > Guaranteed safety of constraints and need for
deliverables, etc. persons and equipment. continuity of supply are
Reworking to conformity taken into account as
from the design stage.
> Choice of products
out of the latest
Schneider Electric
ranges.

For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
 NORMAL STOCK ITEMS W.E.F. March 12, 2018

schneider-electric.co.in 77
Schneider Electric India Pvt. Ltd.
Corporate Office: 9th Floor, DLF Building No. 10, Tower C, DLF Cyber City, Phase II, Gurugram 122002 Haryana
Tel.: ++91 124 3940400 Fax: ++91 124 4222036/ 037

Ahmedabad Cochin Ludhiana


Secunderabad
Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd.
D.No. 1-8-271, # 401, Ashoka Bhoopal
1506-1507, 15th Floor Shapth-5, 41 / 406- D1,3rd Floor, Beejay Office No. - 3, 5th Floor, Novelty Plaza
Chambers, SP Road,
SG Highway, Ahmedabad - 380015 Towers, Bhaiwala Chowk
Secunderabad - 500003
Tel.: 079-66826701 Rajaji Road Cochin- 682035 Ludhiana- 140001
Tel.: 04039404000
Tel.: 0484-3048401 Tel.: 0161- 4656672-75
Fax.: 040-39131313

Bengaluru Coimbatore Mumbai Vadodara


Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd. Schneider Electric India (P)( Ltd) 605 & 606, 6th Floor Ocean Building,
No. 3/1, JP Techno Park, No. -104, Classic Tower, 3rd Floor, Marwah House, 2nd Floor Opp.Vadodara Central, Sarabhai Road,
Mezzanine Floor, Millers Tank Bund Trichy Road, Coimbatore- 641018 Krishanlal Marwah Marg, Vadodara-390005
Road, Vasanth Nagar, Tel.: 0422-3940400 Andheri (East), Mumbai - 400072 Tel.: 0265-3940400
Bengaluru - 560052. Tel.: 080-71481351 Tel.: 91-22-30263300

Bhubaneswar: Jaipur Nagpur Vishakhapatnam


Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd.
6th Floor, Block A, JSS Software Technol- Jaipur Business Centre 309, 3rd Fortune Business Centre, 6, Ratnam’s Business Centre,
ogy park , E 1/1 , Chandaka Industrial Floor, Sangam Tower 190, Church Basant Vihar, W.H.C Road D.N.10-1-43, 1st Floor
Estate, Info City , Bhubaneswar -751025 Road, Jaipur-302001 Shankar Nagar, Nagpur- 440010 Siripuram Fort,C.B.M.Compound,
Tel.: 0674-6672000 Tel.: 0141-3912903 Tel.: 0712-2558581 Visakhapatnam- 530016
Tel.: 0891 - 2508990

Chandigarh Kolkata Nashik:


Schneider Electric India (P) Ltd. Schneider Electric (I)Pvt.Ltd, Schneider Electric India (P) Ltd.
2nd Floor of Tower A BP-4, Sector-V 401, 4th Floor Rishi Raj Towers, Jehan
Bestech Business Tower Technopolis Circle, Gangapur Road,
Sector-66 3rd floor, Salt Lake City Nashik- 422013
Mohali- 160059 Kolkata- 700 091 Tel: +91-7620498557
Tel.: 0172-3324500 Tel.: 033-333640100-101

Chennai Lucknow Pune


Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd. Schneider Electric India (P) Ltd.
No:29, 2nd floor, Bannari Amman Towers, 1st Floor, Asha Bhawan 27 / II -A, 1st Floor, R.B. Business Centre
B-Block,RK Salai, Mylapore Gokhale Marg, Lucknow- 226001 Above Dass Electronics
Chennai - 600 004 Tel.: 0522-4006010 Sanghvi Nagar, Aundh, Pune- 411007
Tel.:044- 39404000 Tel.: 020-39404000

Customer Care Centre For more information, visit our website at: www.schneider-electric.co.in
Monday-Saturday, 9 a.m. to 8 p.m. • All Prices are in Indian Rupees.
• Prices are subject to change without notice.
Toll-free numbers: 1800 419 4272, 1800 103 0011 • Prices charged will be as prevailing on the date of dispatch.
Email: customercare.in@schneider-electric.com • Maximum Retail Price (MRP) is inclusive of all taxes

• Tax incidence on invoices is basis applicable GST rates.Invoice amount


not to exceed MRP.
• Invoice Amount = (MRP – less Applicable discount) + Applicable GST %

Distributor

You might also like