Low Voltage Distribution Products: Price List
Low Voltage Distribution Products: Price List
Low Voltage Distribution Products: Price List
Low Voltage
Distribution Products
With effect from March 12, 2018
schneider-electric.co.in
Price List Contents
Smart Panels
Introduction to Smart Panels.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Moulded Case Circuit Breakers:
Compact NSXm:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Compact NSX:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . 20
MCCBs for Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MCCBs for DC Network Protection . . . . . . . . . . . . . . . . . . . . . . . . 26
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Automatic Source Changeover System. . . . . . . . . . . . . . . . . . . . . 30
Compact NS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
MCCBs 800A onwards Manual Fixed . . . . . . . . . . . . . . . . . . . . . . 33
MCCBs 800A onwards Electrical Fixed. . . . . . . . . . . . . . . . . . . . . 35
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
EasyPact CVS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . 39
MCCBs for Distribution Network and Motor Protection. . . . . . . . . 41
Easy-Pact CVS Switch Disconnector Version . . . . . . . . . . . . . . . . 42
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Type 2 Co-ordination table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
EasyPact EZC:
Range Overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
MCCBs for Distribution Network.. . . . . . . . . . . . . . . . . . . . . . . . . . 47
Accessories and EasyPact Range Busbar systems. . . . . . . . . . . . ..49
EasyPact NKS
MCCBs for AC Distribution Network . . . . . . . . . . . . . . . . . . . . . . . 50
Simpact NKS DC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Ground Fault / Earth Leakage Protection
Unique Modular Ground Fault Protection . . . . . . . . . . . . . . . . . . . 52
Earth Leakage Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Vigirex - Earth Leakage Protection Relay . . . . . . . . . . . . . . . . . . . 54
Compact- INS & INV Switch Disconnectors . . . . . . . . . . . . . . . . . . . . 55
Switch Disonnector fuse units - range overview. . . . . . . . . . . . . . . . . 56
Fupact Switch Disconnector and Accessories. . . . . . . . . . . . . . . . . . 57
Fupact -Type 2 Co-ordination table. . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Air Circuit Breakers:
Masterpact NT/NW:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Micrologic Trip system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
ATS Kit range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
EasyPact MVS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
ET/ETA/ETV Trip System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Draw-out type Circuit breakers and Switch Disconnectors. . . . . . 68
Fixed type Circuit breakers and Switch Disconnectors. . . . . . . . . 70
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Price List Contents
EasyPact SPS:
Range Overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Draw-out type Circuit breakers and Switch disconnector. . . . . . . 74
Fixed type Circuit breaker and Switch disconnector. . . . . . . . . . . 75
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Panel C-42 // 10:30 a.m.
schneider-electric.com/smart-panels
schneider-electric.co.in 5
Smart Panels
Make your electrical installations smart, simple & reliable
1 Protect
Electrical protection is at the core of
Smart Panels
4 Act
Reliable and high-performance technology
is present in every breaker and every • Data driven energy efficiency actions
residual current device. • Real time monitoring and control
• Access to energy and site information
2 Measure through online services
Keeping a close eye on energy flows
The switchboard plays a key role in capturing
building related data, by gathering the
protection and metering component’s data.
3 Connect
Give a voice to the panel
Ethernet network data transmission is now
part of the intrinsic design of protection and
metering devices
Switchboard display
Notifications
schneider-electric.co.in 7
schneider-electric.co.in 8
schneider-electric.co.in 9
Compact NSXm circuit breakers:
Optimized for your needs
The Compact NSXm range of circuit breakers and switch disconnectors
is a newcomer in the Compact NSX family. It is one of the smallest on the
market with innovative features. Built on the design of roto-active
breaking technology, we have made it as robust as Compact NSX
products.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
schneider-electric.co.in 10
Compact NSXm Moulded Case Circuit Breakers
For details on stockable and non stockable status, technical parameter, please contact Customer Care Centre W.E.F. March 12, 2018
schneider-electric.co.in 11
Compact NSXm Moulded Case Circuit Breakers
For Details on stockable and non-stockable status, technical parameter, please Contact Customer Care Centre
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 12
Compact NSXm Switch Disconnector
NSXm Accessories
Auxiliary contacts (changeover) Voltage Releases
Description Reference Unit LP [`] Shunt Release Under Voltage
Description Unit LP [`] Unit LP [`]
Standard OF or SD LV426950 770 Reference Reference
AC
Rotary Handles 24 V 50/60 Hz LV426841 LV426801
Description Reference Unit LP [`] 48 V 50/60 Hz LV426842 LV426802
Direct rotary handle 110-130 V 50/60 Hz LV426843 1890 LV426803 2460
Standard black handle LV426930 1060 220-240 V 50/60 Hz LV426844 LV426804
Extended rotary handle 380-415 V 50 Hz LV426846 LV426806
Standard extended rotary DC
LV426932 1570
black handle 24 V LV426841 LV426801
Side rotary handle 48 V LV426842 LV426802
1890 2460
Standard side rotary black 125 V LV426843 LV426803
LV426935 2690
handle 250 V LV426844 LV426815
Rotary Handles
Description Reference Unit LP [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV426940 580
Spreaders (Set of 4) 4P LV426941 590
Please contact Customer Care Center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 13
schneider-electric.co.in 14
Ethernet Ready Next Generation Circuit Breakers
Compact NSX
LV circuit breakers from 16A to 630A
• Ethernet based monitoring, control, alarm notification for energy, asset and network
management
• Built-in energy metering with combined accuracy class of 2% for precise
measurement
• Intelligent / Enhanced discrimination for continuity of service
• Patented reflex tripping, independent of other protection functions, ensures ultra fast
tripping in the event of very high short circuit
• Encapsulated roto-active double break contact system limits fault current for extended
system life
• Best in class electrical life (30k cycles for NSX 100 @ 440 V) reduces operational expenditure
• High performance => Ics = Icu = 100kA @ 690V AC
Range Details:
• 16A to 630A in two frames sizes
• Breaking capacity up to 200kA @ 415V
• TMD and Microprocessor based trip unit
• Available in Fixed, Plug-in and Draw out type versions
schneider-electric.co.in 16
Type of Trip Units
Example
Micrologic 1.3 M I 400 or 630 A Motor
Micrologic 2.2 G LS0I 100, 160 or 250 A Generator
Micrologic 2.3 LS0I 400 or 630 A Distribution
Micrologic 2.3 M LS0I 400 or 630 A Motor
Micrologic 5.2 A LSI 100, 160 or 250 A Ammeter Distribution
Micrologic 5.3 E LSI 400 or 630 A Energy Distribution
Micrologic 6.3 E-M LSIG 400 or 630 A Energy Motor
I - Instantaneous
S0 - Short Time with Fixed Time Delay
S - Short Time with Adjustable Time Delay
G - Ground Fault
schneider-electric.co.in 17
Compact NSX PV for Photovoltaic applications
schneider-electric.co.in 18
PowerPact
1
Trust US...
> to supply worldwide availabilty stop
> to apply tested and validated solutions
> to comply to international standards shop
schneider-electric.co.in 19
Compact NSX Moulded Case Circuit Breakers for
Distribution Network
Note:
• ** applicable for NSX 200A & 250A
• For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 20
Compact NSX Moulded Case Circuit Breakers for
Distribution Network
Note: For higher breaking capacities (100kA and 150kA); for Generator Protection MCCB and other special application MCCB, contact our nearest Sales office.
Relay Module 3 Ph + 3W 3 Ph + 4W
MCCB Frame Unit LP [`] Unit LP [`]
rated current Reference Reference
CVS/NSX100 32, 40, 50, 63, 80, 100 GFP11CT13P 4930 GFP11CT14P 5400
CVS/NSX 160 / 250 125, 160, 200, 250 GFP12CT23P 5610 GFP12CT24P 6330
CVS/NSX 400 / 630 400, 630 GFP13CT33P 8470 GFP13CT34P 9250
CVS 800 800 GFP14CT43P 10440 GFP14CT44P 11690
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 21
Compact NSX Moulded Case Circuit Breakers for
Distribution Network
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 22
Compact NSX Moulded Case Circuit Breakers for
Distribution Network
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 23
Compact NSX Moulded Case Circuit Breakers for
Motor Protection
Note: For higher breaking capacities (100kA and 150kA), contact our nearest Sales office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 24
Compact NSX Moulded Case Circuit Breakers for
Motor Protection
Note:
• For higher breaking capacities (100kA and 150kA), contact our nearest Sales office.
• For arriving at the Reference of the MCCB with Micrologic 6E-M, please contact our nearest Sales office.
Micrologic 6 E-M
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 25
MCCBs for DC Network Protection
Compact NSX DC
Range - 16A to 1200A in Two frames sizes with Thermal Magnetic Trip Unit (TMD)
Note:
• For 1P / 2P contact customer care
• NSX 1200 prices on request
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 26
Compact NSX Accessories
Indication contacts SDTAM remote SDx remote Voltage Release Motor Mechanism
indication relay indication relay
module module
Unit LP
Description Reference
[`]
Auxiliary contacts (changeover) Multifunction
OF or SD or SDE or SDV 29450 820
OF or SD or SDE or SDV low level 29452 885
SDE adaptor for trip unit TM or MA or Micrologic 2 $$ LV429451 640
SDX 2-PROGRAMMABLE CONTACTS FOR MICROLOGIC
SDx module 24/415 V AC/DC LV429532 10210
SDTAM contactor tripping module for Micrologic 2- M/6 E-M
SDTAM 24/415 V AC/DC overload fault indication LV429424 10580
Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 LV429406
2100 2690
220-240 V 50/60 Hz LV429387 LV429407
380-415 V 50 Hz LV429388 LV429408
525 V 50 Hz LV429389 LV429409
DC
12 V LV429382 LV429402
24 V LV429390 LV429410
30 V LV429391 LV429411
48 V LV429392 2100 LV429412 2690
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414
Installation Accessories
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Spreaders & Phase Barrier
Spreaders (Set of 3) 3P LV431563 600 32492 1360
Spreaders (Set of 4) 4P LV431564 800 32493 1730
Phase Barrier (Set of 6) * - LV432570 685
Interlocking
For Breaker with Rotary Handle LV429369 7960 LV432621 10020
For Breaker with Toggle LV429354 8705 LV432614 10020
Mechanical Interlocking with Base Plate 29349** 16670 32609** 35115
Locking of Rotary Handle
Locking Device LV429344 500 LV432604 685
Ronis Keylock (1 Lock + 1 Key set) 41940 3475 41940 3475
Ronis Keylock (2 Locks + 1 Key set) 41950 6700 41950 6700
Profalux Keylock (1 Lock + 1 Key set) 42888 5870 42888 5870
Profalux Keylock (2 Locks + 1 Key set) 42878 6700 42878 6700
* supplied as standard with spreader
** Mechanical Interlocking with Base Plate to be ordered with Safety trip interlock (LV429270 for 29349 and LV432520 for 32609)
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 27
Compact NSX Accessories
FDM121: Front Display Test Battery Power Supply ModuleB SCM: Breaker Status and
Module Control Module
Motor Mechanism
100/160A Unit LP 250A Unit LP 400/630A Unit LP
Type Voltage
Reference [`] Reference [`] Reference [`]
Motor Mechanism Modules with SDE adaptor (1)
48-60 V LV429440 LV431548 LV432639
110-130 V LV429433 LV431540 LV432640 30950
AC
220-240 V LV429434 19650 LV431541 21720 LV432641
50/60 Hz
380-415 V LV429435 LV431542 LV432642 31410
440-480 V LV429435 LV431542 LV432647 30950
24-30 V LV429436 LV431543 LV432643
48-60 V LV429437 LV431544 LV432644
DC 25855 28035 37055
110-130 V LV429438 LV431545 LV432645
250 V LV429439 LV431546 LV432646
(1) With every Motor Mechanism, please order 1 no. auxiliary contact additionally. For other voltages of motor mechanism please consult Customer Care.
Unit LP
Description Reference
[`]
ULP Display Module
Switchboard front display module FDM121 TRV00121 10685
ULP Wiring Accessories
NSX cord L = 0.35 m LV434200 2460
NSX cord L = 1.3 m LV434201 2500
5 RJ45/RJ45 MALE Cord L = 1m TRV00810 2330
10 Stacking connectors for COM interface TRV00217 3630
ULP Communication Module
IFM MODBUS Interface Module LV434000 9330
BSCM ( Breaker Status and Control Module) LV434205 7860
Power Supply Modules
External power supply module 24 V DC-1 A OVC IV
24-30 V DC 54440 13530
48-60 V DC 54441 13530
100-125 V AC 54442 13530
110-130 V AC 54443 15180
200-240 V AC 54444 15180
380-415 V AC 54445 15180
Pocket battery for Micrologic NSX100-630 LV434206 15550
Maintenance Module for advanced configuration and testing, contact our nearest Sales office.
ULP = Universal Logic Plug
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 28
Compact NSX Accessories
Direct Rotary Handle Extended Rotary Handle Plug in Base Draw-Out Chassis Kit
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 29
Compact NSX Automatic Source Changeover System
BA controller (basic)
• Monitoring of “Normal” source & “Automatic” transfer
• Circuit breaker status indication on front of controller: ON, OFF & fault trip
• Voluntary transfer to “Replacement” source (e.g. energy management commands)
UA controller (advanced)
• Monitoring of “normal” source & “Automatic” transfer
• Circuit breaker status indication on front of controller: on, off & fault trip
• Voluntary transfer to “replacement” source (e.g. energy management commands)
• Delayed (adjustable) shutdown of generator set
• Load shedding & reconnection of non-priority loads
• Transfer to “Replacement” source if one of the phases of the “Normal” phase is
absent
• During peak tariff period (energy management commands) forced operation on
“Normal” source if “Replacement” source not operational
With NSX100F - NSX630F 36kA 3P MCCB
Breaker for Breaker for 3P BA Controller Unit MRP 3P UA Controller Unit MRP
Normal Supply Replacement Supply Reference [`] Reference [`]
NSX100F NSX100F LV4A3F100100B4 206765 LV4A3F100100U4 226275
NSX160F NSX100F LV4A3F160100B4 213375 LV4A3F160100U4 232875
NSX160F NSX160F LV4A3F160160B4 219495 LV4A3F160160U4 239005
NSX250F NSX100F LV4A3F250100B4 227140 LV4A3F250100U4 246645
NSX250F NSX160F LV4A3F250160B4 233750 LV4A3F250160U4 253260
NSX250F NSX250F LV4A3F250250B4 247460 LV4A3F250250U4 266970
NSX400F NSX100F LV4A3F400100B4* 265340 LV4A3F400100U4* 267965
NSX400F NSX160F LV4A3F400160B4* 270925 LV4A3F400160U4* 274015
NSX400F NSX250F LV4A3F400250B4* 271405 LV4A3F400250U4* 278130
NSX400F NSX400F LV4A3F400400B4 304410 LV4A3F400400U4 323905
NSX630F NSX160F LV4A3F630160B4* 244255 LV4A3F630160U4* 261655
NSX630F NSX250F LV4A3F630250B4* 255420 LV4A3F630250U4* 272810
NSX630F NSX400F LV4A3F630400B4 307435 LV4A3F630400U4 326945
NSX630F NSX630F LV4A3F630630B4 310415 LV4A3F630630U4 329920
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 30
Compact NSX Automatic Source Changeover System
BA controller (basic)
• Monitoring of “Normal” source & “Automatic” transfer
• Circuit breaker status indication on front of controller: ON, OFF & fault trip
• Voluntary transfer to “Replacement” source (e.g. energy management commands)
UA controller (advanced)
• Monitoring of “Normal” source & “Automatic” transfer.
• Circuit breaker status indication on front of controller: ON, OFF & fault trip
• Voluntary transfer to “Replacement” source (e.g. energy management commands)
• Delayed (adjustable) shutdown of generator set.
• Load shedding & reconnection of non-priority loads.
• Transfer to “Replacement” source if one of the phases of the “Normal” phase is absent
• During peak tariff period (energy management commands) forced operation on
“Normal” source if “Replacement” source not operational
Note:
Each reference consists of:
• 2 MCCBs with Motor mechanism & Standard Trip Units.
• 4 Auxiliary contacts 2OF + 2SDE
• 1 Base Plate with IVE unit for mechanical & electrical interlocking
• 1 Downstream coupling accessory is supplied only when both the MCCB are of same Frame size.
• Control Unit UA or BA
ATS upto 250A are provided with TMD type trip unit & for 400/630A with Micrologic 2 trip unit as standard.
ATS with MCCBs of other breaking capacities & other versions of trip units can also be supplied. Prices available on request.
Above given references with BA/UA controller are suitable for 415V AC control supply.
UA controller with 220/240V AC is not available
Replace suffix “4” by “2” for BA controller with 220/240V AC control supply.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 31
Compact NS
Simply A Step Ahead
Circuit breakers and switch-disconnectors from 800 to 3200A
• Category B MCCBs
• Ethernet based monitoring, control, alarm notification for energy, asset and network management
• Built-in energy metering with combined accuracy class of 2% for improved energy efficiency
• Total Discrimination
• Breaking Capacity upto 150kA
2 3 sizes:
from 800 to 3200A
sizes
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 32
Compact NS MCCB for Distribution Network
800A onwards, Manual Fixed Type
With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
With Micrologic 2.0 Manual Fixed
Micrologic 2.0
instantaneous
Isd 4 5
3
2.5 6
•
2 8
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_3P33466D 59570 INA_4P33469D 77930
50kA 1000 INA_3P33472D 76460 INA_4P33475D 110940
1250 INA_3P33478D 95340 INA_4P33480D 146210
800 INA_3P33467D 72810 INA_4P33470D 93060
70kA 1000 INA_3P33473D 96340 INA_4P33476D 144850
1250 INA_3P33479D 120210 INA_4P33481D 159560
With Extended Rotary Handle
800 INA_3P33466E 63190 INA_4P33469E 82100
50kA 1000 INA_3P33472E 82190 INA_4P33475E 118370
1250 INA_3P33478E 98080 INA_4P33480E 149470
800 INA_3P33467E 76820 INA_4P33470E 97680
70kA 1000 INA_3P33473E 100950 INA_4P33476E 151040
1250 INA_3P33479E 120840 INA_4P33481E 166140
long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
• Communication optional
Ig
D E F (s) .4 .4 .3
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_3P96466D 84380 INA_4P96469D 102740
50kA 1000 INA_3P96472D 101260 INA_4P96475D 135750
1250 INA_3P96478D 118770 INA_4P96480D 168650
800 INA_3P96467D 97620 INA_4P96470D 117870
70kA 1000 INA_3P96473D 121140 INA_4P96476D 169670
1250 INA_3P96479D 143160 INA_4P96481D 184370
With Extended Rotary Handle
800 INA_3P96466E 88640 INA_4P96469E 107640
50kA 1000 INA_3P96472E 106090 INA_4P96475E 153145
1250 INA_3P96478E 121720 INA_4P96480E 170390
800 INA_3P96467E 102370 INA_4P96470E 123230
70kA 1000 INA_3P96473E 126500 INA_4P96476E 176550
1250 INA_3P96479E 144950 INA_4P96481E 189790
Remarks:Trip Unit Micrologic 6.0.A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 33
Compact NS MCCB for Distribution Network
above 800A Manual Fixed
With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
With Micrologic 2.0E Manual Fixed (With Embedded Energy Metering)
• LED overload alarm indicator
Micrologic 2.0 E
MWh
_ _5.678
• Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power
100 %
40 %
(P,Q,S) ,power factor, power demand, Energy (Ep, Eq, Es)
menu • Adjustable neutral protection - N, N/2, OFF for 4 Pole MCCBs
• Communication option & M2C programmable contacts
long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
instantaneous
Isd
3 4 5
2.5 6
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_8N3PFM2ED1 87180 INA_8N4PFM2ED1 101220
50kA 1000 INA_10N3PFM2ED1 99635 INA_10N4PFM2ED1 145820
1250 INA_12N3PFM2ED1 123700 INA_12N4PFM2ED1 179710
800 INA_8H3PFM2ED1 102180 INA_8H4PFM2ED1 125400
70kA 1000 INA_10H3PFM2ED1 129030 INA_10H4PFM2ED1 184670
1250 INA_12H3PFM2ED1 151140 INA_12H4PFM2ED1 201470
With Extended Rotary Handle
800 INA_8N3PFM2EE1 89160 INA_8N4PFM2EE1 103045
50kA 1000 INA_10N3PFM2EE1 108605 INA_10N4PFM2EE1 147780
1250 INA_12N3PFM2EE1 136600 INA_12N4PFM2EE1 182095
800 INA_8H3PFM2EE1 104385 INA_8H4PFM2EE1 127310
70kA 1000 INA_10H3PFM2EE1 131060 INA_10H4PFM2EE1 186630
1250 INA_12H3PFM2EE1 153130 INA_12H4PFM2EE1 203490
Micrologic 6.0 A
With Micrologic 6.0E Manual Fixed (With Embedded Energy Metering)
2100A
• LED overload alarm indicator
• Measurement: Ammeter, current demand, voltages (ph-ph, ph-N & unbalance), Power (P,Q,S)
,power factor,power demand, Energy (Ep, Eq, Es)
100 %
40 %
menu
• Adjustable neutral protection - N, N/2, OFF
• With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
• Communication optional
• Individual fault indication by LED
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
With Direct Rotary Handle
800 INA_8N3PFM6ED1 92300 INA_8N4PFM6ED1 117670
50kA 1000 INA_10N3PFM6ED1 125260 INA_10N4PFM6ED1 163835
1250 INA_12N3PFM6ED1 141615 INA_12N4PFM6ED1 191780
800 INA_8H3PFM6ED1 116400 INA_8H4PFM6ED1 141710
70kA 1000 INA_10H3PFM6ED1 148270 INA_10H4PFM6ED1 204450
1250 INA_12H3PFM6ED1 170520 INA_12H4PFM6ED1 221480
With Extended Rotary Handle
800 INA_8N3PFM6EE1 97965 INA_8N4PFM6EE1 119555
50kA 1000 INA_10N3PFM6EE1 126220 INA_10N4PFM6EE1 165750
1250 INA_12N3PFM6EE1 143585 INA_12N4PFM6EE1 195770
800 INA_8H3PFM6EE1 117360 INA_8H4PFM6EE1 143800
70kA 1000 INA_10H3PFM6EE1 150190 INA_10H4PFM6EE1 206450
1250 INA_12H3PFM6EE1 172550 INA_12H4PFM6EE1 221515
Remarks:Trip Unit Micrologic 6.0E
## Display shows readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office
Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 34
Compact NS MCCB for Distribution Network
above 800A Electrical Fixed
With Micrologic Trip Units ( Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
Micrologic 2.0
instantaneous
Isd 4 5
3
2.5 6
2 8
1.5 10
x Ir
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_3P93280_20 107750 INA_4P93284_20 122375
50kA 1000 INA_3P93290_20 126815 INA_4P93294_20 165645
1250 INA_3P93300_20 143850 INA_4P93304_20 198925
800 INA_3P93281_20 122705 INA_4P93285_20 145560
70kA 1000 INA_3P93291_20 149145 INA_4P93295_20 203840
1250 INA_3P93301_20 170830 INA_4P93305_20 220350
For Control Voltage 415V AC
800 INA_3P93280_40 107750 INA_4P93284_40 122375
50kA 1000 INA_3P93290_40 126815 INA_4P93294_40 165645
1250 INA_3P93300_40 143850 INA_4P93304_40 198925
800 INA_3P93281_40 122705 INA_4P93285_40 145560
70kA 1000 INA_3P93291_40 149145 INA_4P93295_40 203840
1250 INA_3P93301_40 170830 INA_4P93305_40 220350
2100A
• Test Facility
• Adjustable neutral protection - N, N/2, OFF
100 %
40 %
Ir
.7
menu
long time
.8
.9
tr
(s) 4
8
12
alarm
• With ammeter display & bargraph ## (Bargraph is unique feature of Schneider MCCB)
• Zone Selective Interlocking
.6 .95 2 16
.5 .98 1 20
.4 1 .5 24
x In at 6 Ir
• Communication optional
setting delay
test
tg
Ig
D E F (s) .4 .4 .3
C G .3 .2
B H .2 .1
A I .1 2 0
on I t off
ground fault
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_3P96280_20 135685 INA_4P96284_20 156345
50kA 1000 INA_3P96290_20 154750 INA_4P96294_20 193590
1250 INA_3P96300_20 165175 INA_4P96304_20 218125
800 INA_3P96281_20 150640 INA_4P96285_20 173495
70kA 1000 INA_3P96291_20 177070 INA_4P96295_20 231775
1250 INA_3P96301_20 198760 INA_4P96305_20 248275
For Control Voltage 415V AC
800 INA_3P96280_40 135685 INA_4P96284_40 156345
50kA 1000 INA_3P96290_40 154750 INA_4P96294_40 193590
1250 INA_3P96300_40 165175 INA_4P96304_40 218125
800 INA_3P96281_40 150640 INA_4P96285_40 173495
70kA 1000 INA_3P96291_40 177070 INA_4P96295_40 231775
1250 INA_3P96301_40 198760 INA_4P96305_40 248275
## Display shows Readings of I1,I2,I3, In & Earth Fault Current Value. Also Maximeters of Three Phase Currents are stored & displayed.
LED bargraph shows the % loading on each phase
Note: For above MCCB with trip unit Micrologic 5.0, 5.0A, 5.0P, 6.0P and MCCB with higher breaking capacities, contact our nearest Sales Office
Functionality of all the above Micrologic is same as that of Masterpact NT/NW ACB.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 35
Compact NS MCCB for Distribution Network
above 800A Electrical Fixed
With Micrologic Trip Units (Common for ACBs & MCCBs) - Unique Feature of Schneider Electric devices
Micrologic 2.0 E
With Micrologic 2.0E Electrical Fixed (With Embedded Energy Metering)
MWh
long time
Ir .8 tr 8
alarm
.7 .9 (s) 4 12
.6 .95 2 16
.5 .98 1 20
instantaneous
Isd
3 4 5
2.5 6
2 8
1.5 10
x Ir
setting
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
Icu as per IEC 60947-2 [A] Reference [`] Reference [`]
For Control Voltage 220/240V AC
800 INA_8N3PFE2E0120 128390 INA_8N4PFE2E0120 149725
50kA 1000 INA_10N3PFE2E0120 147690 INA_10N4PFE2E0120 187230
1250 INA_12N3PFE2E0120 165440 INA_12N4PFE2E0120 221070
800 INA_8H3PFE2E0120 141080 INA_8H4PFE2E0120 166760
70kA 1000 INA_10H3PFE2E0120 170440 INA_10H4PFE2E0120 226030
1250 INA_12H3PFE2E0120 192460 INA_12H4PFE2E0120 242810
For Control Voltage 415V AC
800 INA_8N3PFE2E0140 128390 INA_8N4PFE2E0140 149725
50kA 1000 INA_10N3PFE2E0140 147690 INA_10N4PFE2E0140 187230
1250 INA_12N3PFE2E0140 165440 INA_12N4PFE2E0140 221070
800 INA_8H3PFE2E0140 141080 INA_8H4PFE2E0140 166760
70kA 1000 INA_10H3PFE2E0140 170440 INA_10H4PFE2E0140 226030
1250 INA_12H3PFE2E0140 192460 INA_12H4PFE2E0140 242810
Accessories
For Compact NS800 - 1600A
Shunt Release Undervoltage
Type Voltage Unit LP [`] Reference Unit LP [`]
Reference
Voltage Releases
24 V 33659 5100 33668 5200
AC 48 V 33660 5100 33669 5200
50/60 Hz 110-130 V 33661 5100 33670 5200
220-240 V 33662 5100 33671 5200
380-415 V 33664 5100 33673 5200
24 V 33659 5100 33668 5200
DC 48 V 33660 5100 33669 5200
125 V 33661 5100 33670 5200
250 V 33662 5100 33671 5200
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 36
The easy choice for quality and value
EasyPact CVS
LV circuit breakers from 16A to 800A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
Safe
NORMAL STOCK ITEMS
Reliable Simple W.E.F. March 12, 2018
schneider-electric.co.in 37
EasyPact CVS
Easy Choice for Quality and Value
• EasyPact CVS MCCBs upto 630A is the easy choice for all your most common electrical distribution
applications
• Encapsulated double break roto technique ensures outstanding current limiting capability
• High electrical / mechanical endurance for enhanced service life
• Single accessory reference for different functions – on/off, trip and fault trip – improves shop floor efficiency
• Separate electrical fault indication for ease of fault diagnosis
• Suitable for isolation
Range Details:
• Breaking capacity 25kA to 50kA, Ics = 100% Icu
• TMD & Microprocessor trip units (400 & 630A) are available
• 3P & 4P versions available
• Common accessories upto 630A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 38
EasyPact CVS 100 BS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 BS Overload Setting (Ir) 0.8 - 1 x In
16A LV510930 5740 LV510950 7780
20A LV510931 5740 LV510951 7780
25A LV510932 5740 LV510952 7780
32A LV510933 5740 LV510953 7780
25kA* 40A LV510934 5740 LV510954 7780
50A LV510935 5740 LV510955 7780
63A LV510936 5740 LV510956 7780
80A LV510937 5740 LV510957 7780
100A LV510938 5740 LV510958 7780
Accessories
CVS100BS Unit LP
Description
Reference [`]
Auxiliary contacts (changeover) Multifunction
Auxiliary Switch 1 C/O EZAUX10 740
Alarm Switch 1 C/O EZAUX01 740
Alarm - Auxiliary Switch EZAUX11 1105
Spreaders
Spreaders *(Set Of 3) 3P EZASPDR3P 300
Spreaders *(Set Of 4) 4P EZASPDR4P 400
Rotary Handle
Direct Rotary handle EZAROTDS 1055
Extended Rotary handle EZAROTE 1580
Shunt Release
AC
100-130 V EZASHT100AC 1580
200-277 V EZASHT200AC 1580
380-480 V EZASHT380AC 1580
DC
24 V EZASHT024DC 1580
48 V EZASHT048DC 1580
*Ics=17kA
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 39
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
Easypact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510300 6250 LV510310 8640
25A LV510301 6250 LV510311 8640
32A LV510302 6250 LV510312 8640
40A LV510303 6250 LV510313 8640
50A LV510304 6250 LV510314 8640
25kA 63A LV510305 6250 LV510315 8640
80A LV510306 6250 LV510316 8640
100A LV510307 6250 LV510317 8640
125A LV516302 9030 LV516312 10940
160A LV516303 11780 LV516313 13980
200A LV525302 15750 LV525312 19360
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
25kA 250A LV525303 18200 LV525313 22120
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
Easypact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510330 8810 LV510340 10940
25A LV510331 8810 LV510341 10940
32A LV510332 8810 LV510342 10940
40A LV510333 8810 LV510343 10940
50A LV510334 8810 LV510344 10940
36kA 63A LV510335 8810 LV510345 10940
80A LV510336 8810 LV510346 10940
100A LV510337 8810 LV510347 11300
125A LV516332 9630 LV516342 11930
160A LV516333 12950 LV516343 15310
200A LV525332 18010 LV525342 22400
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525333 19600 LV525343 23960
320A LV540305 25100 LV540308 31760
36kA 400A LV540306 25330 LV540309 32050
500A LV563305 27950 LV563308 34870
630A** LV563306 30620 LV563309 37910
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
16A LV510470 11560 LV510480 14210
25A LV510471 11560 LV510481 14210
32A LV510472 11560 LV510482 14210
40A LV510473 11560 LV510483 14210
50A LV510474 11560 LV510484 14210
50kA 63A LV510475 11560 LV510485 14210
80A LV510476 11560 LV510486 14210
100A LV510477 11560 LV510487 14210
125A LV516462 14890 LV516467 16290
160A LV516463 15500 LV516468 18460
200A LV525452 20150 LV525457 25200
Breaking Capacity Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525453 21660 LV525458 26580
320A LV540315 25610 LV540318 32010
50kA 400A LV540316 26120 LV540319 32650
500A LV563315 30300 LV563318 38230
630A** LV563316 31990 LV563319 40690
Note:
• EasyPact CVS can also be used for DC network protection (from 16-630A TMD)
• For performance and other details contact our nearest Sales Office.
* *630A @ 300C & 600A @ 400 C for TMD630A MCCB
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 40
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Ics Rated Current Three Pole Unit LP Four Pole Unit LP
as per IEC 60947-2 Reference [`] Reference [`]
36kA 800A LV580300 49310 LV580301 53210
50kA 800A LV580302 54530 LV580303 60440
Current Rating 2.5 6.3 12.5 25 50 100 150 220 320 500
CVS 100 6..14In
CVS 160/250 9..14In
CVS 400 6..13In
CVS 630 6..13In
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 41
Easy-Pact CVS Switch Disconnector Version
Rated Current Three Pole Reference Unit MRP [`] Four Pole Reference Unit MRP [`]
100A LV510425 5450 LV510426 6900
160A LV516425 6500 LV516426 8170
Rated Current Three Pole Reference Unit LP [`] Four Pole Reference Unit LP [`]
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 42
EasyPact CVS Accessories for EasyPact CVS
Indication contacts Voltage Release Padlocking accessory Direct Rotary Handle Extended Rotary Handle
Voltage Releases
Shunt Release Unit LP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 LV429406
2100 2690
220-240 V 50/60 Hz LV429387 LV429407
380-415 V 50 Hz LV429388 LV429408
525 V 50 Hz LV429389 LV429409
DC
12 V LV429382 LV429402
24 V LV429390 LV429410
30 V LV429391 LV429411
48 V LV429392 2100 LV429412 2690
60 V LV429383 LV429403
125 V LV429393 LV429413
250 V LV429394 LV429414
Rotary Handles
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Direct rotary handle
Standard black handle LV429337 1070 LV432597 1605
Extended rotary handle
Standard extended rotary handle LV429338 1700 LV432598 3020
Installation Accessories
100/160/250A Unit LP 400/630A Unit LP
Description
Reference [`] Reference [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV431563 600 32492 1360
Spreaders (Set of 4) 4P LV431564 800 32493 1730
Phase Barriers (Set of 6) * LV432570 685
Interlocking
For Breaker with Rotary Handle LV429369 7960 LV432621 10020
For Breaker with Toggle LV429354 8705 LV432614 10020
Mechanical Interlocking with Base Plate 29349** 16670 32609** 35115
Locking of Rotary Handle
Locking Device LV429344 500 LV432604 685
Ronis Keylock (1 Lock + 1 Key set) 41940 3475 41940 3475
Ronis Keylock (2 Locks + 1 Key set) 41950 6700 41950 6700
Profalux Keylock (1 Lock + 1 Key set) 42888 5870 42888 5870
Profalux Keylock (2 Locks + 1 Key set) 42878 6700 42878 6700
* supplied as standard with spreaders
** Mechanical Interlocking with Base Plate to be ordered with Safety trip interlock (LV429270 for 29349 and LV432520 for 32609)
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 43
EasyPact CVS Accessories for EasyPact CVS
Auxiliary/Alarms contacts
Unit LP
Description Reference
[`]
Auxiliary Switch 1 C/O LV580075 1130
Alarm Auxiliary switch 1 c/o LV580079 1585
Voltage Releases
Shunt Release Unit MRP Undervoltage Unit LP
Description
Reference [`] Reference [`]
AC
220-240 V 50/60 Hz LV580061 2155 LV580071 2700
Rotary Handles
800A Unit LP
Description
Reference [`]
Extended rotary handle
Standard extended rotary handle LV580081 1890
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 44
Type 2 Co-ordination Table Fuseless (DOL Starter) with
EasyPact CVS
• Standard : IEC 60947-4-1
• Short Circuit Protection Device type: MCCB
• Performance «Iq» (kA) : 50kA
• Operational Voltage (Ue) : 415VAC / 50Hz
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 45
EasyPact EZC
With just three sizes of circuit breakers, Schneider Electric’s EasyPact EZC system is the simple, universal solution, particularly
adapted to Buildings and OEM segments
• Suitability for Isolation ensures safety
• Compliance to RoHS (Restriction of Hazardous Substances) for environment safety
Range Details:
• Global MCCB offer from 15A to 600A
• Breaking capacity upto 50kA @ 415 V AC
• 1P, 2P, 3P and 4P versions available
• EZC AC version is suitable for DC applications upto 250V DC (15A to 250A breaking capacity up to 30kA)
• Built in Earth leakage version 63A to 250A @ Icu36kA.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 46
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network
• Conforms to IEC60947-2
• Suitable for isolation
• Suitable for EasyPact Busbar system
Unit MRP
BREAKING CAPACITY ICU AS PER IEC 60947-2 Rated Current Three Pole Reference
[`]
16A EZC100F3016
20A EZC100F3020
25A EZC100F3025
32A EZC100F3032
“10 kA @ 415V AC
40A EZC100F3040 2640
5kA @ 250V DC (2pole in series)”
50A EZC100F3050
63A EZC100F3063
80A EZC100F3080
100A EZC100F3100
125A EZC250F3125 5955
150A EZC250F3150 6000
“18 kA @ 415V AC
160A EZC250F3160 6800
5kA @ 250V DC (2pole in series)”
175A EZC250F3175
8355
200A EZC250F3200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“18 kA @ 415V AC
250A EZC250F3250 9775
5kA @ 250V DC (2pole in series)”
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Single Pole
[`]
16A EZC100N1016
20A EZC100N1020
25A EZC100N1025
32A EZC100N1032
"18 kA @ 240V AC
40A EZC100N1040 1885
5kA @ 125V DC "
50A EZC100N1050
63A EZC100N1063
80A EZC100N1080
100A EZC100N1100
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Two Pole Reference
[`]
16A EZC100H2016
20A EZC100H2020
25A EZC100H2025
32A EZC100H2032
“50 kA @ 240V AC
40A EZC100H2040 3080
10kA @ 250V DC (2pole in series)”
50A EZC100H2050
63A EZC100H2063
80A EZC100H2080
100A EZC100H2100
125A EZC250H2125 6300
150A EZC250H2150 7420
“85 kA @ 240V AC
160A EZC250H2160 7420
30kA @ 250V DC (2pole in series)”
175A EZC250H2175
8935
200A EZC250H2200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“85 kA @ 240V AC
250A EZC250H2250 9200
30kA @ 250V DC (2pole in series)”
Note:
• Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
• 630A and other breaking capacity versions on request.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 47
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
15A EZC100H3015 EZC100H4015
20A EZC100H3020 EZC100H4020
25A EZC100H3025 EZC100H4025
32A EZC100H3032 EZC100H4032
“30 kA @ 415V AC
40A EZC100H3040 4160 EZC100H4040 5770
10kA @ 250V DC (2pole in series)”
50A EZC100H3050 EZC100H4050
63A EZC100H3063 EZC100H4063
80A EZC100H3080 EZC100H4080
100A EZC100H3100 EZC100H4100
125A EZC250N3125 6100 EZC250N4125 8420
“25 kA @ 415V AC
160A EZC250N3160 7400 EZC250N4160 9910
20kA @ 250V DC (2pole in series)”
200A EZC250N3200 8780 EZC250N4200 11080
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
"25 kA @ 415V AC
250A EZC250N3250 10035 EZC250N4250 12990
20kA @ 250V DC (2pole in series)"
Breaking Capacity Icu as per Rated Current Three Pole Reference Unit MRP Four Pole Unit MRP
IEC 60947-2 [`] Reference [`]
125A EZC250H3125 6400 EZC250H4125 8630
"36 kA @ 415V AC
160A EZC250H3160 8390 EZC250H4160 10800
30kA @ 250V DC (2pole in series)"
200A EZC250H3200 10410 EZC250H4200 14070
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
“36 kA @ 415V AC
250A EZC250H3250 11640 EZC250H4250 15720
30kA @ 250V DC (2pole in series)”
320A EZC400H3320N 18220 EZC400H4320N 21000
400A EZC400H3400N 18790 EZC400H4400N 24560
“50 kA @ 415V AC“
500A EZC630H3500N 23700 EZC630H4500N 30800
600A EZC630H3600N 24700 EZC630H4600N 32200
Note:
• Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
• 630A and other breaking capacity versions on request.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 48
EasyPact EZC Accessories
Unit LP
Description EZC 400/600 Reference
[`]
Auxiliary Contacts
OF or SD or SDE 29450 820
Spreaders
Spreaders (Set of 3) 3P 32492 1360
Spreaders (Set of 4) 4P 32493 1730
Phase Barriers (Set of 6) LV432570 685
Rotary Handle
Direct Rotary handle LV432597 1605
Extended Rotary handle LV432598 3020
Shunt Release
AC 220-240 V 50/60 Hz LV429387 2100
Unit LP
[In] Rated Current Description Reference
[`]
EZ busbar 250A 4ways EZB250W04 8245
EZ busbar 250A 6ways EZB250W06 10425
250 A EZ busbar 250A 8ways EZB250W08 12610
EZ busbar 250A 10ways EZB250W10 14815
EZ busbar 250A 12ways EZB250W12 16995
EZ busbar 400A 4ways EZB400W04 10425
EZ busbar 400A 6ways EZB400W06 12610
400 A EZ busbar 400A 8ways EZB400W08 14815
EZ busbar 400A 10ways EZB400W10 16995
EZ busbar 400A 12ways EZB400W12 19180
EZ busbar 630A 4ways EZB630W04 12610
EZ busbar 630A 6ways EZB630W06 14815
630 A EZ busbar 630A 8ways EZB630W08 16995
EZ busbar 630A 10ways EZB630W10 19180
EZ busbar 630A 12ways EZB630W12 21370
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 49
EasyPact NKS Moulded Case Circuit Breakers for
Distribution Network
AC MCCB
Fixed Thermal Magnetic Trip Unit (TMD)
• Conforms to IEC60947-2
Unit MRP
Breaking Capcity Icu as per IEC60947-2 Rated Current Reference
[`]
15 NKS100R015AC3P 1500
20 NKS100R020AC3P 1500
25 NKS100R025AC3P 1500
32 NKS100R032AC3P 1500
40 NKS100R040AC3P 1500
50 NKS100R050AC3P 1500
63 NKS100R063AC3P 1500
75 NKS100R075AC3P 1500
10kA *
100 NKS100R100AC3P 1500
110 NKS160R110AC3P 3470
125 NKS160R125AC3P 3470
140 NKS160R140AC3P 3840
150 NKS160R150AC3P 3840
160 NKS160R160AC3P 3840
175 NKS200R175AC3P 5050
200 NKS200R200AC3P 5050
*Ics=5kA
Note:
• Contact customer care for other accessories
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 50
Simpact NKS DC MCCB
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 51
Unique Modular Ground Fault Protection
Note: Kindly order one no. Shunt trip coil along with one Ground Fault Protection Module for CVS100 to 630. Order one auxiliary contact alongwith shunt coil for
CVS800.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 52
Earth Leakage Protection
Earth Leakage Protection is obtained by: Fitting a VIGI Module on the Circuit Breakers
VIGI Module Earth Leakage Device for EasyPact CVS/ Compact NSX Range Moulded
Case Circuit Breakers
• Compliance with Standards - IEC60947-2 appendix B, IEC 60255-4 and IEC60801-2 to 5 covering protection against
nuisance tripping due to:
◦ Transient overvoltages, lightning strikes
◦ Switching of devices on the distribution system
◦ Electrostatic discharges and radio frequency disturbances
• Device can be equipped with multifunction aux contact of MCCB to remotely signal tripping due to earth fault
• Self powered - “no aux supply required”
• Instantaneous tripping at 30mA in less the 40ms for human protection
• Direct acting device - no shunt/UV release required in MCCB
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 53
Vigirex Earth Leakage Protection Relay
Vigirex Relays
Vigirex Relays along with Vigirex Sensors, may be may be used to add external Earth Leakage Protection to Circuit Breakers
• Sensitivity Adjustments from 30mA to 30A and time delay settings from (0-4.5 seconds)
• Closed Toroid up to 630A (30 to 300mm in diameter), Split Toroid up to 250A (46 to 110mm in diameter) or
• Rectangular sensor up to 3200A
• 400Hz Distribution System
Note: For further details, please contact our nearest Sales Office.
Control Voltage Din rail mount Unit MRP Front panel mount Unit MRP
Type
Reference [`] Reference [`]
RH10 with local manual fault reset 220/240VAC 56130 56230
9425 10355
Sensitivity=0.03A 380/415VAC 56140 56240
RH99 with local manual fault reset 220/240VAC 56173 14245 56273 15420
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC 56174 15710 56274 16195
RH197P with local manual or automatic fault reset 220/240VAC - 56507* 17440
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC - 56508* 18315
RH197P with local manual or automatic fault reset 220/240VAC - 56512** 17615
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC - 56513** 18490
Vigirex Sensors
Note: For vigirex relay with monitoring and communication facility, contact nearest sales office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 54
Compact- INS & INV Switch Disconnectors
For Low Voltage Circuit Control and Isolation - Incomers for Distribution Boards
• Conforms to IEC 60947-3/IS 13947 - 3
• Rated operational voltages 500V/690V
• Range 40A to 2500A
• Rated operational current @ AC 23A
• No deration upto 60° C
• Positive contact indication
• Common accessories with Compact NSX/single auxillary contact
• Making capacity enhanced with Compact NSX upstream
Accessories
Optional front extended rotary handle INS 250 - black handle (Switch Disconnector) LV431050 3495
Optional front extended rotary handle INS 320..630 - black handle (Switch Disconnector) 31052 4945
Optional front extended rotary handle INS 40..160 - black handle (Switch Disconnector) LV428941 1775
6 phase separators - INS100..160 28959 775
6 phase separators - INS250 29329 685
6 phase separators - INS400..630 LV432570 685
For
Please
details
contact
on non-standard
Customer Care
references,
Center for
technical
Stockable
parameters,
and Non stockable
stockable and
status
non-stockable
of references.
status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 55
SDF Switch Disconnector Fuse units
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 56
Fupact Switch Disconnector Fuse units
• Complete Range from 32 to 630A in TP, TP+N & FP version suitable for
DIN/BS fuses.
• 4 breaks and 8 arcing points
• IP20 Fuse Protection Cover is standard
• Higher Mechanical and Electrical life.
Without Enclosure
Rated Operational DIN Type Unit LP BS Type Unit LP
Poles Description
Current Reference [`] Reference [`]
32 A 3P + N NX032TPNDI 2190 NX032TPNBS 2160
63 A 3P + N NX063TPNDI 2890 NX063TPNBS 2870
80 A 3P + N NX080TPNDI 5470 NX080TPNBS 5210
3P NX100TPXDI 6040
100 A 3P + N NX100TPNDI 6270 NX100TPNBS 6220
4P NX100FPXDI 6520
3P NX125TPXDI 7040
125 A 3P + N NX125TPNDI 7690 NX125TPNBS 7610
4P NX125FPXDI 8650
3P NX160TPXDI 7760
160 A 3P + N NX160TPNDI 8380 NX160TPNBS 7890
4P NX160FPXDI 9660
3P NX200TPXDI 10270
200 A 3P + N NX200TPNDI 10770 NX200TPNBS 9470
4P NX200FPXDI 12050
3P NX250TPXDI 12590
250 A 3P + N NX250TPNDI 12960 NX250TPNBS 12440
4P NX250FPXDI 15250
3P NX315TPXDI 15820
315 A 3P + N NX315TPNDI 16050 NX315TPNBS 15790
4P NX315FPXDI 17800
3P NX400TPXDI 21140
400 A 3P + N NX400TPNDI 21940 NX400TPNBS 20740
4P NX400FPXDI 26440
3P NX630TPXDI 31210
630 A 3P + N NX630TPNDI 31920 NX630TPNBS 31600
4P NX630FPXDI 35600
Accessories/Spares
NX032/NX063/NX080
Auxiliary contact for Fupact NXAA11 445
Fuse holder for DIN NX032...NX080 NXHD1 210
Handle operating mechanism (HOM) NX032...NX080 NXR1 395
HOM shaft for NX/32/63/80 NXRS1 210
NX100/NX125/NX160
Auxiliary contact for Fupact NXBA11 515
Fuse holder DIN for BS type NX100...NX160 NXHB21 190
Fuse holder DIN for NX100...NX160 NXHD21 210
Handle operating mechanism NX100...NX160 NXR2 755
Shaft for HOM for NX100...NX160 NXRS2 210
NX200
Auxiliary contact for Fupact NXBA11 515
Fuse holder for BS type NX200 NXHB22 200
Fuse holder for DIN NX200 NXHD22 230
Handle operating mechanism NX200 NXR2 755
Shaft for HOM for NX200 NXRS2A 260
NX250/315/400
Auxiliary contact for Fupact NXBA11 515
Handle operating mechanism for NX250...NX400 NXR3 785
Shaft for HOM for NX250…NX400 NXRS3 260
NX630
Auxiliary contact for Fupact NXBA11 515
Handle operating mechanism for NX630 NXR4 835
Shaft for HOM for NX630 NXRS4 260
Note: For other versions please contact our nearest Sales Office.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 57
Fupact - Type 2 Co-ordination Table With Fuse
Motor Output FLC SDF (NX Range) Contactor Thermal Overload Relay
Fuse Rating
KW HP I(A) Type Fuse Type Type AC3 (A) Type Range (A)
(A)
0.37 0.5 1 NX32 6NHG000B 6 LC1E09 9 LRE06 1.0 - 1.6
0.55 0.75 1.5 NX32 6NHG000B 6 LC1E09 9 LRE06 1.0 - 1.6
0.75 1 2 NX32 6NHG000B 6 LC1E09 9 LRE07 1.6 - 2.5
1.5 2 3.5 NX32 16NHG000B 16 LC1E09 9 LRE08 2.5 - 4.0
2.2 3 5 NX32 16NHG000B 16 LC1E09 9 LRE10 4.0 - 6.0
3 4 6.8 NX32 20NHG000B 20 LC1E09 9 LRE12 5.5 - 8.0
4 5.5 8.4 NX32 20NHG000B 20 LC1E09 9 LRE14 7.0 - 10
5.5 7.5 11.2 NX32 25NHG000B 25 LC1E12 12 LRE16 9.0 - 13
7.5 10 14 NX63 40NHG000B 40 LC1E18 25 LRE21 12.0 - 18
9 12 18 NX63 50NHG000B 50 LC1E25 25 LRE22 16 - 24
11 15 21 NX63 50NHG000B 50 LC1E32 32 LRE22 16 - 24
15 20 28.5 NX63 63NHG000B 63 LC1E32 40 LRE32 23 - 32
18.5 25 34 NX80 80NHG000B 80 LC1E40 40 LRE355 30 - 40
22 30 42 NX80 80NHG000B 80 LC1E50 50 LRE357 37 - 50
30 40 57 NX100 100NHG000B 100 LC1E65 65 LRE359 48- 65
37 50 70 NX125 125NHG00B 125 LC1E80 80 LRE363 63- 80
45 60 81 NX160 160NHG00B 160 LC1E95 95 LRE365 80- 104
56 75 100 NX160 160NHG00B 160 LC1E120 115 LRE482 84- 135
80 107 138 NX250 250NHG1B 250 LC1E160 150 LRE483 124- 198
90 120 165 NX250 250NHG1B 250 LC1E160 160 LRE483 124- 198
100 135 182 NX315 315NHG2B 315 LC1E200 200 LRE483 124- 198
110 150 196 NX315 315NHG2B 315 LC1E200 200 LRE483 124- 198
132 177 240 NX400 355NHG2B 355 LC1E250 250 LRE485 174- 279
160 215 285 NX400 400NHG2B 400 LC1E300 300 LRE486 208- 333
Thermal Overload
Motor Output FLC SDF (NX Range) Contactor
Relay
Main /
I Line I phase Fuse Star Range
KW HP Type Fuse Type AC3- A Delta Con- AC3- A Type
(A) (A) Rating (A) Contactor (A)
tactor
1.5 2 4 2.3 NX32 10NHC00G 10 LC1E09 9 LC1E09 9 LRE07 1.6-2.5
2.2 3 5 3 NX32 16NHC00G 16 LC1E09 9 LC1E09 9 LRE08 2.5-4
3 4 7 4 NX32 16NHC00G 16 LC1E09 9 LC1E09 9 LRE08 2.5-4
4 5.3 9 5 NX32 20NHC00G 20 LC1E09 9 LC1E09 9 LRE10 4-6
5.5 7.5 10 6 NX32 20NHC00G 20 LC1E09 9 LC1E09 9 LRE12 5.5-8
7.5 10 16 9 NX32 32NHC00G 32 LC1E09 9 LC1E09 9 LRE14 7-10
9 12 17 10 NX32 32NHC00G 32 LC1E09 9 LC1E12 9 LRE14 7-10
11 15 21 12 NX63 50NHC00G 50 LC1E12 12 LC1E12 12 LRE16 9-13
15 20 28 16 NX63 63NHC00G 63 LC1E18 18 LC1E18 18 LRE21 12-18
22 30 42 24 NX80 80NHC00G 80 LC1E25 25 LC1E25 25 LRE32 23-32
30 40 57 33 NX125 100NHG00B 100 LC1E40 40 LC1E40 40 LRE355 30-40
45 60 81 47 NX125 125NHG00B 125 LC1E40 40 LC1E50 50 LRE357 37-50
55 75 100 58 NX125 125NHG00B 125 LC1E40 40 LC1E65 65 LRE359 48-65
80 107 139 80 NX200 200NHG1B 200 LC1E80 80 LC1E80 80 LRE363 63-80
110 150 196 113 NX315 315NHG2B 315 LC1E300 300 LC1E300 300 LRE482 84~135
160 215 286 165 NX400 355NHG2B 355 LC1E300 300 LC1E300 300 LRE483 124~198
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 58
The Benchmark for Power Circuit Breakers around the world
Masterpact NT/NW
LV power circuit breakers 630 to 6300 A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
Network Protection Supervision Compact
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 59
Masterpact NT and NW
Ethernet ready Masterpact NT and NW breakers, setting the standard for performance, safety, connectivity and
built-in metering; all in optimized frame sizes
• Ethernet based monitoring, control, alarm notification for energy, asset and network management
• Built-in energy metering with combined accuracy class of 2% for improved energy efficiency
3
• Masterpact is suitable for heavy duty applications
sizes
schneider-electric.co.in 60
Micrologic trip system Overview of functions
X: type of protection
n 2 for basic protection
n 5 for selective protection
n 6 for selective + earth-fault protection
n 7 for selective + earth-leakage protection.
Y: control-unit generation
Identification of the control-unit generation.
“0” signifies the first generation.
Z: type of measurement
n E for” Energy”
n P for “power meter”
n H for “harmonic meter”.
n I1, I2, I3, IN, Iearth-fault, Iearth-leakage and maximeter for these measurements
n fault indications
n settings in amperes and in seconds.
n calculates the current demand value P: E + power meter + programmable protection
n “Quickview” function for the automatic cyclical n measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, Vpeak, Apeak, power
display of the most useful values (as standard factor and maximeters and minimeters
or by selection). n IDMTL long-time protection, minimum and maximum voltage and frequency,
voltage and current imbalance, phase sequence, reverse power
n load shedding and reconnection depending on power or current
measurements of interrupted currents, differentiated fault indications,
n maintenance indications, H: P + harmonics
event histories and
time-stamping, etc. n power quality: fundamentals, distortion, amplitude and
phase of harmonics up to the 31st order
n waveform capture after fault, alarm or on request
n enhanced alarm programming: thresholds and actions.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 61
Micrologic Trip unit
Energy efficiency, now within your reach
DB101124
DB101124
DB127408
Micrologic 6.0 E
100 %
40 %
menu
long time
alarm
short time
ground fault
Current , maximeter ● ● ●
Measurement
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 62
ATS Kit
Unit MRP
Description Reference
[`]
ATS Kit for Masterpact NT EDO type with BA 415VAC controller INA_NTDOB4 119875
ATS Kit for Masterpact NT EDO type with UA 415VAC controller INA_NTDOU4 137520
ATS Kit for Masterpact NW EDO type with BA 415VAC controller INA_NWDOB4 129875
ATS Kit for Masterpact NW EDO type with UA 415VAC controller INA_NWDOU4 165020
**ATS Kit with for Fixed Breaker and BA controller with 240VAC, contact our customer care
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 63
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 64
The easy choice for reliable performance
EasyPact MVS
LV power circuit breakers and switch
disconnectors from 800 to 4000 A
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 65
EasyPact MVS
Range Details:
• Single frame for 800A to 4000A
• Fixed, Draw out type
• Entire Range Icu=Ics=Icw=50kA for 1sec @440V
• Suitability for applications up to 690 V
• Flexible terminal orientation enables horizontal or vertical alignment changes in the field*
schneider-electric.co.in 66
ET/ETA/ETV Trip System
Voltage Metering
ZSI
Features
% Loading Bar Graph for each
phase
Thermal Memory
2 (L, I) 2L 2A 2V
Protection
6 (L,S,I,G) 6G 6A 6V
NEW
EasyPact ACB CommunicationModule
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 67
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚C
• Zone Selective Interlocking
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• Icu=Ics=Icw(1sec) = 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit LP Unit LP Unit LP Unit LP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW6L 171140 MVS08N3NW6L 215640 MVS08N4MW6L 214800 MVS08N4NW6L 259300
1000 MVS10N3MW6L 179780 MVS10N3NW6L 224280 MVS10N4MW6L 225040 MVS10N4NW6L 269540
1250 MVS12N3MW6L 200180 MVS12N3NW6L 244680 MVS12N4MW6L 249250 MVS12N4NW6L 293750
1600 MVS16N3MW6L 227510 MVS16N3NW6L 272010 MVS16N4MW6L 277610 MVS16N4NW6L 322110
2000 MVS20N3MW6L 276560 MVS20N3NW6L 321060 MVS20N4MW6L 339650 MVS20N4NW6L 384150
2500 MVS25N3MW6L 341920 MVS25N3NW6L 386420 MVS25N4MW6L 415480 MVS25N4NW6L 459980
3200 MVS32N3MW6L 417560 MVS32N3NW6L 462060 MVS32N4MW6L 512000 MVS32N4NW6L 556500
4000 MVS40N3MW6L 510700 MVS40N3NW6L 555200 MVS40N4MW6L 649500 MVS40N4NW6L 694000
Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MW0D
ACB with ET6A trip unit Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For ACB
Add `9200
(LCD display with Current Metering) reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MW6A
Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX) (Voltage
ratings to be specified by customer & duty filled in ACB Order form)
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 68
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚C
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• ET2L provides Overload & Short-circuit protections
• Icu=Ics=Icw(1sec) = 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit LP Unit LP Unit LP Unit LP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW2L 163740 MVS08N3NW2L 208240 MVS08N4MW2L 207400 MVS08N4NW2L 251900
1000 MVS10N3MW2L 172380 MVS10N3NW2L 216880 MVS10N4MW2L 217640 MVS10N4NW2L 262140
1250 MVS12N3MW2L 192780 MVS12N3NW2L 237280 MVS12N4MW2L 241850 MVS12N4NW2L 286350
1600 MVS16N3MW2L 220110 MVS16N3NW2L 264610 MVS16N4MW2L 270210 MVS16N4NW2L 314710
2000 MVS20N3MW2L 269160 MVS20N3NW2L 313660 MVS20N4MW2L 332250 MVS20N4NW2L 376750
2500 MVS25N3MW2L 334520 MVS25N3NW2L 379020 MVS25N4MW2L 408080 MVS25N4NW2L 452580
3200 MVS32N3MW2L 410160 MVS32N3NW2L 454660 MVS32N4MW2L 504600 MVS32N4NW2L 549100
4000 MVS40N3MW2L 503300 MVS40N3NW2L 547800 MVS40N4MW2L 642100 MVS40N4NW2L 686600
ACB with ET2A trip unit (LCD display with Example : ACB reference with ET2L trip unit - MVS08N3MW2L. For ACB
Add `4600
Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MW2A
AC* Same Philosophy for 3 Pole/ 4 Pole and Manual/ Electrical References
Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX).
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 69
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚ C
• Zone Selective Interlocking
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• Icu=Ics=Icw(1sec) =50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
Rating 3P Fix Manual Unit LP 3P Fix Electrical Unit LP 4P Fix Manual Unit LP 4P Fix Electrical Unit LP
in (A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF6L 127610 MVS08N3NF6L 172110 MVS08N4MF6L 162250 MVS08N4NF6L 206750
1000 MVS10N3MF6L 139690 MVS10N3NF6L 184190 MVS10N4MF6L 176210 MVS10N4NF6L 220710
1250 MVS12N3MF6L 160550 MVS12N3NF6L 205050 MVS12N4MF6L 200590 MVS12N4NF6L 245090
1600 MVS16N3MF6L 178220 MVS16N3NF6L 222720 MVS16N4MF6L 230370 MVS16N4NF6L 274870
2000 MVS20N3MF6L 208240 MVS20N3NF6L 252740 MVS20N4MF6L 272140 MVS20N4NF6L 316640
2500 MVS25N3MF6L 253870 MVS25N3NF6L 298370 MVS25N4MF6L 320740 MVS25N4NF6L 365240
3200 MVS32N3MF6L 363400 MVS32N3NF6L 407900 MVS32N4MF6L 448370 MVS32N4NF6L 492870
4000 MVS40N3MF6L 447520 MVS40N3NF6L 492020 MVS40N4MF6L 561050 MVS40N4NF6L 605550
Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MF0D
ACB with ET6A trip unit (LCD display Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For ACB
Add `9200
with Current Metering) reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MF6A
Note:
All Fix type circuit breakers will be supplied with:
(i) horizontal / vertical terminal
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) door sealing frame- Escutcheon (CDP).
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 70
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50° C
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• Icu=Ics=Icw(1sec) =50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
Rating in 3P Fix Manual Unit LP 3P Fix Electrical Unit LP 4P Fix Manual Unit LP 4P Fix Electrical Unit LP
(A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF2L 120210 MVS08N3NF2L 164710 MVS08N4MF2L 154850 MVS08N4NF2L 199350
1000 MVS10N3MF2L 132290 MVS10N3NF2L 176790 MVS10N4MF2L 168810 MVS10N4NF2L 213310
1250 MVS12N3MF2L 153150 MVS12N3NF2L 197650 MVS12N4MF2L 193190 MVS12N4NF2L 237690
1600 MVS16N3MF2L 170820 MVS16N3NF2L 215320 MVS16N4MF2L 222970 MVS16N4NF2L 267470
2000 MVS20N3MF2L 200840 MVS20N3NF2L 245340 MVS20N4MF2L 264740 MVS20N4NF2L 309240
2500 MVS25N3MF2L 246470 MVS25N3NF2L 290970 MVS25N4MF2L 313340 MVS25N4NF2L 357840
3200 MVS32N3MF2L 356000 MVS32N3NF2L 400500 MVS32N4MF2L 440970 MVS32N4NF2L 485470
4000 MVS40N3MF2L 440120 MVS40N3NF2L 484620 MVS40N4MF2L 553650 MVS40N4NF2L 598150
ACB with ET2A trip unit (LCD display Example : ACB reference with ET2L trip unit - MVS08N3MF2L. For ACB
Add `4600
with Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MF2A
Note:
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 71
EasyPact MVS Accessories
Terminal Block
For drawout circuit breaker 47849 210
Under Voltage Release (MN)
24/30 V DC, 24 V AC 33668
48/60 V DC, 48 V AC 33669
AC 50/60 Hz DC 100/130 V AC/DC 33670 5200
200/250 V AC/DC 33671
380/480 V AC 33673
MN Delay Unit
48/60 V AC/DC 33680
100/130 V AC/DC 33681
Rr (adjustable) 7600
200/250 V AC/DC 33682
AC 50/60 Hz DC
380/480 V AC/DC 33683
100/130 V AC/DC 33684
R (non-adjustable) 7100
200/250 V AC/DC 33685
ON/OFF Indication Contacts (Additional OF contact)
1 additional block of 4 contacts 47887 4600
Door Interlock (VPECD)/1 part
On right hand side of chassis 47914 2500
Operation Counter
Operation Counter CDM 48535 7150
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 72
EasyPact SPS
800-1600A
ET2.0 ET6G
Trip System Trip System
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 73
EasyPact SPS Draw-out type Circuit breakers and
Switch Disconnectors 800-1600A
• All Easypact SPS Air Circuit Breakers are equipped with terminal adaptors
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• Fully rated neutral with inbuilt protection
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• ET2B provides Overload & Short-circuit protections
• Short circuit breaking capacity 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW6L 130880 SPS08F3PEW6L 168780 SPS08F4PMW6L 164130 SPS08F4PEW6L 202030
1000 SPS10F3PMW6L 137130 SPS10F3PEW6L 175030 SPS10F4PMW6L 173620 SPS10F4PEW6L 211520
1250 SPS12F3PMW6L 153380 SPS12F3PEW6L 191280 SPS12F4PMW6L 195630 SPS12F4PEW6L 233530
1600 SPS16F3PMW6L 173040 SPS16F3PEW6L 210940 SPS16F4PMW6L 221450 SPS16F4PEW6L 259350
Draw-out Type circuit breaker with Microprocessor based ET2B Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit LP Unit LP Unit LP Unit LP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW2B 129080 SPS08F3PEW2B 166980 SPS08F4PMW2B 162330 SPS08F4PEW2B 200230
1000 SPS10F3PMW2B 135330 SPS10F3PEW2B 173230 SPS10F4PMW2B 171820 SPS10F4PEW2B 209720
1250 SPS12F3PMW2B 151580 SPS12F3PEW2B 189480 SPS12F4PMW2B 193830 SPS12F4PEW2B 231730
1600 SPS16F3PMW2B 171240 SPS16F3PEW2B 209140 SPS16F4PMW2B 219650 SPS16F4PEW2B 257550
Note:
All draw-out type circuit breakers will be supplied with:
(i) Vertical-vertical terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 74
EasyPact SPS Fixed type Circuit breakers and
Switch Disconnectors 800-1600A
• All Easypact SPS Air Circuit Breakers are equipped with terminal adaptors
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• Fully rated neutral with inbuilt protection
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• ET2B provides Overload & Short-circuit protections
• Short circuit breaking capacity 50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit
3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF6L 100540 SPS08F3PEF6L 138440 SPS08F4PMF6L 122230 SPS08F4PEF6L 160130
1000 SPS10F3PMF6L 105850 SPS10F3PEF6L 143750 SPS10F4PMF6L 131240 SPS10F4PEF6L 169140
1250 SPS12F3PMF6L 122040 SPS12F3PEF6L 159940 SPS12F4PMF6L 152260 SPS12F4PEF6L 190160
1600 SPS16F3PMF6L 141320 SPS16F3PEF6L 179220 SPS16F4PMF6L 174060 SPS16F4PEF6L 211960
Fixed Type circuit breaker with Microprocessor based ET2B Trip Unit
3P 3P 4P 4P
Rating Unit LP Unit LP Unit LP Unit LP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF2B 98740 SPS08F3PEF2B 136640 SPS08F4PMF2B 120430 SPS08F4PEF2B 158330
1000 SPS10F3PMF2B 104050 SPS10F3PEF2B 141950 SPS10F4PMF2B 129440 SPS10F4PEF2B 167340
1250 SPS12F3PMF2B 120240 SPS12F3PEF2B 158140 SPS12F4PMF2B 150460 SPS12F4PEF2B 188360
1600 SPS16F3PMF2B 139520 SPS16F3PEF2B 177420 SPS16F4PMF2B 172260 SPS16F4PEF2B 210160
Note: All Fixed type circuit breakers will be supplied with: (i) Vertical-vertical terminations. (ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
All switch disconnectors are without protection | All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) and shunt release
(MX). | External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price. | Any other accessories are optional at extra price.
Accessories
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 75
“Ecodial Advance Calculation 4” sizing software
schneider-electric.co.in 76
Ecodial Advance Calculation 4
For details on non-standard references, technical parameters, stockable and non-stockable status, please contact Customer Care Centre.
NORMAL STOCK ITEMS W.E.F. March 12, 2018
schneider-electric.co.in 77
Schneider Electric India Pvt. Ltd.
Corporate Office: 9th Floor, DLF Building No. 10, Tower C, DLF Cyber City, Phase II, Gurugram 122002 Haryana
Tel.: ++91 124 3940400 Fax: ++91 124 4222036/ 037
Customer Care Centre For more information, visit our website at: www.schneider-electric.co.in
Monday-Saturday, 9 a.m. to 8 p.m. • All Prices are in Indian Rupees.
• Prices are subject to change without notice.
Toll-free numbers: 1800 419 4272, 1800 103 0011 • Prices charged will be as prevailing on the date of dispatch.
Email: customercare.in@schneider-electric.com • Maximum Retail Price (MRP) is inclusive of all taxes
Distributor