Model: Installation, Operation & Maintenance Manual
Model: Installation, Operation & Maintenance Manual
Model: Installation, Operation & Maintenance Manual
INDEX
Page
ORBINOX SPAIN Pol.Ind. s/n-20270 ANOETA. Tel:+34 943 698030 Fax:+34 943 653066 e-mail:orbinox@orbinox.com
ORBINOX COMERCIAL, ORBINOX CANADA, ORBINOX USA, ORBINOX UK, ORBINOX INDIA
www.orbinox.com
MODEL EX
0.- DESCRIPTION
The EX model knife gate is a uni-directional wafer valve designed for general industrial service
applications. The design of the body and seat assures non-clogging shut-off with suspended
solids.
1.- HANDLING
When handling an Orbinox valve please pay attention to the following points:
• Do NOT attach lifting gear to the valve actuators or gate guards. They are not
designed to bear the weight, and could easily be damaged.
• Do NOT lift the valve by the valve bore.
This can cause damage to the seating surfaces and seals.
Ideally when using lifting gear to move an Orbinox valve, it should be supported by two or more
eyebolts screwed into the tapped fixing holes in the valve body.
SAFETY WARNING:
• Check that the lifting gear is rated to carry the weight of the valve.
• Make sure the eyebolts have the same thread as the boltholes and that they are well
secured.
During installation it is recommended to lift the valve via soft straps. These can be to the upper
part of the valve body.
2.- INSTALLATION
To avoid personal injury or damage to property from the release of process fluid:
- Those in charge of handling and maintenance of the valve must be qualified and
trained in valve operations.
- Use appropriate personal protection equipment (gloves, safety shoes, etc).
- Shut off all operating lines to the valve and place a warning sign.
- Isolate the valve completely from the process.
- Release process pressure.
- Drain the process fluid from the valve.
Before installation, inspect the valve body and components for any damage that may have
occurred during shipping or storage. Make sure the internal cavities within the valve body are
clean. Inspect the pipeline and mating flanges, making sure the pipe is free of foreign material
and that the flanges are clean.
The valve is unidirectional. It should be installed with pressure exerted against the seat. The
words “SEAT SIDE” are marked on the valve body to indicate the position of the valve seat.
Installation and the correct orientation with respect to the direction of the flow is the
responsibility of the user.
.
2005 EDITION
www.orbinox.com EX04-2/10
MODEL EX
It should be noted that the direction of flow and differential pressure, do not always coincide.
Special care should be taken to maintain the correct distance between the flanges and to
ensure that they are parallel to the valve body. Incorrect alignment of the valve can cause
deformations, which can lead to difficulties in operation.
The following table gives the maximum torque values for the valve fixing bolts. Also shown is
the maximum depth (T) allowed for the tapped blind boltholes drilled into the valve body.
DN 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000
T (mm) 10 10 10 10 10 14 14 18 18 22 24 24 24 24 20 20 20 20
Kg.m 6 6 6 6 7 7 7 11 11 15 15 19 19 23 23 28 28 34
The valve can be mounted in any position with regard to the pipe. However, it is advisable to
place it vertically in horizontal pipeline (A) if the installation allows it. (Please consult the
technical department at Orbinox).
.
2005 EDITION
www.orbinox.com EX04-3/10
MODEL EX
With larger diameters (> 300 mm), heavy actuators (pneumatic, electric, etc.), or with the valve
installed horizontally (B) or at an angle (C) on a horizontal pipeline, the installation will require
the construction of suitable supports. (See the following diagram and consult the technical
department at Orbinox).
C C
B B
C* C*
A*
In vertical pipelines, the construction of suitable supports is always required (for further
information please consult the technical department at Orbinox).
Once the valve is installed, test that the flanges have been fastened correctly and that all
electrical and/or pneumatic connections have been properly made.
Where electric accessories are mounted on the valve (i.e. solenoid valves, electro-pneumatic
positioners, etc.), the valve must be earthed correctly before being put into operation.
First, operate the valve with no flow in the pipeline. Then test operation and valve seal with
flow. It should be noted that the packing material might settle in shipping/storage, which can
cause minor leakage. This can be remedied by tightening the gland follower (5) during
installation. The nuts shall be tightened gradually and crosswise until the leakage stops (see
the next figure). Check that there is no metal contact between the glandfollower (5) and the
gate (2).
2 3
1
4
.
2005 EDITION
www.orbinox.com EX04-4/10
MODEL EX
If the glandfollower nuts are pulled to hard, the force needed to operate the valve will increase,
the valve function will be affected and the box packing lifetime will be shortened.
The table below shows the maximun torque value for tightening the glandfollower nuts.
ND Torque (N.m)
50 - 100 20
125 - 200 30
250 - 1000 35
Once performance has been tested, the valve can be put into operation.
DN 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 1200
Weight(Kg) 7 8 9 11 15 18 30 44 58 96 124 168 192 245 405 455 512 680 865 1055
3.- ACTUATORS
3.1.- Handwheel
To open the valve turn the handwheel (11) anticlockwise. To close turn the handwheel
clockwise.
3.2.- Lever
To operate the valve with this device, first loosen the locking clamp located on the top of
the yoke (8). Then either open or close the valve by moving the lever in the desired
direction. Finally, fix the position of the lever with the locking clamp.
3.3.- Pneumatic
Valves are usually supplied with a double acting pneumatic actuator although, upon
request, we can supply single-acting actuators. In both cases, the inlet air pressure should
be, between 3,5 to 10 Kg/cm2.
It is essential for a good maintenance of the cylinder that air should be well dried, filtered
and lubricated.
It is recommended to actuate the cylinder 3-4 times before the start up, once it is installed
in the pipeline.
Depending on the type or make of the electric actuator, specific instructions (i.e. a
manufacturer’s manual) will be supplied.
.
2005 EDITION
www.orbinox.com EX04-5/10
MODEL EX
4.- MAINTENANCE
To avoid personal injury or damage to property from the release of process fluid:
- Those in charge of handling and maintenance of the valve must be qualified and
trained in valve operations.
- Use appropriate personal protection equipment (gloves, safety shoes, etc).
- Shut off all operating lines to the valve and place a warning sign.
- Isolate the valve completely from the process.
- Release process pressure.
- Drain the process fluid from the valve.
The only maintenance required is to change the gland packing (4) or the seal (3) if the valve is
a resilient seated type.
The life of these elements will depend on the working conditions of the valve such as:
pressure, temperature, abrasion, chemical action, number of operations, etc.
Photo 1 Photo 2
4) Loosen the screws of the yoke (8) and remove it (without loosing the actuator).
5) Loosen the nuts of the gland follower (5) and remove it. (Photo 3)
6) Remove the old packing rings (4) and clean the stuffing box.
7) Insert the new packing rings (4), making sure that the ring joints alternate (the first on
one side of the gate, the next on the other and so on). (Photo 4)
8) Once the necessary packing rings (4) have been inserted, proceed with a steady
initial tightening of the gland follower (5).(Photo 3)
9) Place the yoke (8) (with the actuator) and screw it.
10) Fix the stem (6) to the gate (2)( Rising stem valves.Photo 1) or fix the stem nut to the
gate.(Non rising stem.Photo 2).
11) Remount the gate guards.
.
2005 EDITION
www.orbinox.com EX04-6/10
MODEL EX
12) Carry out some operations with a loaded circuit and then re-tighten the gland follower
(5) to prevent leakage.
Photo 3 Photo 4
4.2.- Replacement of the seal (3) (only applicable to resilient seated valves):
1) Remove the valve from the pipeline.
2) Remove the gate guards (for automatically actuated valves only).
3) Release the spindle or stem (6) from the gate (2).(Rising stem valves.Photo 1) or
release the stem nut from the gate.(Non rising stem.Photo 2).
4) Loosen the screws of the yoke (8) and remove it (without loosing the actuator).
5) Loosen the nuts of the gland follower (5) and remove it.(Photo 3)
6) Remove the old packing (4) and the gate (2) and clean the stuffing box.
7) Remove the seal retainer ring (10) which support the seals (3).
8) Remove the worn seal (3) and clean the seal housing.
9) Once the new seal (3) is cut according to size, insert it into the seat housing (making
sure that the union of the seal is at the top). (Photos 5 and 6)
If the valve has PTFE seal (3), follow the point 4.3.
Seal lengths
ND 50 65 80 100 125 150 200 250 300 350 400 450 500 600
Lengths (mm) 205 255 295 365 440 510 680 860 1020 1190 1350 1510 1630 2010
Photo 5 Photo 6
.
2005 EDITION
www.orbinox.com EX04-7/10
MODEL EX
10) Insert the seal retainer ring (10) by hammering gently around the edge. (Photos 7 and
8)
Photo 7 Photo 8
Follow the same procedure as point 4.2 but with following notes:
1. To obtain a tighter shut off in stainless steel valves (CF8M body), the machined
housing of the seat is sealed with a plastic glue. This is not necessary in cast iron
valves (GG25).
With the seal in this position:
2. Make a circle, joining the ends and making a heart-shaped form (see the following
diagram).
3. Insert both ends of the seal in the upper side of the machined housing of the seat
(adjacent to the gland follower (5)), and pushing the arched part with a finger, insert
the seal into the housing.
If the diameter of the valve is
small (DN≤150), a vice can be
used.
.
2005 EDITION
www.orbinox.com EX04-8/10
MODEL EX
4.4. - Lubrication:
Twice a year, it is recommended to remove the protection cap (12) and fill up the stem
protector (13) halfway with a calcium-based grease with the following characteristics:
highly water resistant, low ash content, and excellent adherence.
5.- STORAGE
For long periods it is recommended to store the valves in a well-ventilated room. Valves
should not be exposed to temperatures higher than 30ºC, as some soft seal materials can be
damaged when exposed to higher temperatures.
If outdoor storage cannot be avoided, cover the valve and protect it from sources of heat or
direct sunlight. Provide good ventilation to avoid moisture.
.
2005 EDITION
www.orbinox.com EX04-9/10
MODEL EX
12
13
11
14
9
7
5
4
3
2
10
1
.
2005 EDITION
www.orbinox.com EX04-10/10