Meder Electronic MK3 Series

Cylindrical
Reed Sensors

DESCRIPTION

MK3 sensors are magnetically operated Reed


proximity switches in a cylindrical case with an
interconnect cable. The sensor should be mounted
on a fixed surface with the actuating magnet on the
moving surface. Introduction or removal of the APPLICATIONS
magnetic field determines the closing and opening
of the Reed Switch.

• Position and limit switch


Pneumatic or hydraulic actuator position
Indication and end travel limit switch
• Door and window contacts
Security system applications
• Level sensor
FEATURES Use with magnetic floats for water level
detection in coffee makers, washing machines
or dishwashers
• High power switches available
• Other cables, connectors and colors available
• Various case sizes available
• Five operate sensitivities available
• A choice of switch terminations and cable
lengths are available

DIMENSIONS
All dimensions in mm [inches]

www.willow.co.uk
Tel. +44 (0) 1342 835234 Fax. +44 (0) 1342 834306
MK3 Series Meder Electronic
Cylindrical
Reed Sensors

ORDER INFORMATION

CABLE Part Number Example


CONTACT SWITCH MAGNETIC
SERIES LENGTH TERMINATION
FORM MODEL SENSITIVITY
(mm)
MK3 - 1A71 C - 500 W
MK3 - XX XX X - XXX X
1A is the contact form
71 B, C, D, E
71 is the switch model
1 Form A 81 A C is the magnetic sensitivity
OPTIONS 500 * W, X, Y 500 is the cable length (mm)
84 W is the termination
C, D, E
1 Form B
90
1 Form C

* Other cable lengths available.

MAGNETIC SENSITIVITY

SENSIT IVITY PULL IN


CLASS AT RANGE

A 5 - 10

B 10 - 15

C 15 - 20

D 20 - 25

E 25 - 30

TERMINATION
For wire and termination details please consult factory.
Form C version requires 3 conductors.

www.willow.co.uk
Tel. +44 (0) 1342 835234 Fax. +44 (0) 1342 834306
Meder Electronic MK3 Series
Cylindrical
Reed Sensors

CONTACT DATA

Switch Model --> Contact 71 Contact 81


All data at 20 0C
Contact Form --> Form A Form A

Contact Ratings Conditions Min. Typ. Max. Min. Typ. Max. Units

Any DC combination of V & A


Contact Rating not to exceed their individual 10 5 W
max.'s

Switching Voltage DC or peak AC 200 90 V

Switching Current DC or peak AC 0.5 0.5 A

Carry Current DC or peak AC 1.25 1.0 A

Static Contact Resistance w/ 0.5V & 10mA 150 200 mΩ

Measured w/ 0.5V & 50mA


Dynamic Contact Resistance 200 200 mΩ
1.5 ms after closure

Insulation Resistance across


100 Volts applied 1010 * 109 Ω
Contacts

Breakdown Voltage across Voltage applied for 60 sec.


225 * 100 VDC
Contacts min.

Operate Time, incl. Bounce Measured w/ 100% overdrive 0.5 0.5 ms

Measured w/ no coil
Release Time 0.1 0.1 ms
suppression

Capacitance @ 10kHz across contact 0.2 0.2 pF

Contact Operation **

Must Operate Condition Steady state field 10 30 5 10 AT

Must Release Condition Steady state field 4 27 2 9 AT

Environmental Data

Shock Resistance 1/2 sine wave duration 11ms 50 30 g

Vibration Resistance From 10 - 2000 Hz 20 10 g

Ambient Temperature 10 0C/ minute max. allowable -20 85 -20 85 0


C

0 0
Storage Temperature 10 C/ minute max. allowable -35 85 -35 85 C

0
Soldering Temperature 5 sec. dwell 260 260 C

Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive switch.
* Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more
detail is required.

www.willow.co.uk
Tel. +44 (0) 1342 835234 Fax. +44 (0) 1342 834306
MK3 Series Meder Electronic
Cylindrical
Reed Sensors

CONTACT DATA

Switch Model --> Contact 84 Contact 90


All data at 20 0 C
Contact Form --> Form A Form B / C

Contact Ratings Conditions Min. Typ. Max. Min. Typ. Max. Units

Any DC combination of V & A


Contact Rating not to exceed their individual 10 3 W
max.'s

Switching Voltage DC or peak AC 400 175 V

Switching Current DC or peak AC 0.5 0.25 A

Carry Current DC or peak AC 1.0 1.2 A

Static Contact Resistance w/ 0.5V & 10mA 150 150 mΩ

Measured w/ 0.5V & 50mA


Dynamic Contact Resistance 200 250 mΩ
1.5 ms after closure

Insulation Resistance across


100 Volts applied 1011 109 Ω
Contacts

Breakdown Voltage across Voltage applied for 60 sec.


700 200 VDC
Contacts min.

Operate Time, incl. Bounce Measured w/ 100% overdrive 2.0 0.7 ms

Measured w/ no coil
Reset Time 0.1 1.5 ms
suppression

Capacitance @ 10kHz across contact 0.7 1.0 pF

Contact Operation **

Must Operate Condition Steady state field 15 30 10 35 AT

Must Reset Condition Steady state field 6 27 4 30 AT

Environmental Data

Shock Resistance 1/2 sine wave duration 11ms 50 50 g

Vibration Resistance From 10 - 2000 Hz 20 20 g

Ambient Temperature 10 0 C/ minute max. allowable -20 85 -20 85 0


C

0 0
Storage Temperature 10 C/ minute max. allowable -35 85 -35 85 C

0
Soldering Temperature 5 sec. dwell 260 260 C

Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive switch.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more
detail is required.

www.willow.co.uk
Tel. +44 (0) 1342 835234 Fax. +44 (0) 1342 834306