Cost-Efficient Solution for Power


Distribution
Ring Main Unit 8DJH ST: Safe, Compact and Reliable
www.siemens.com/mediumvoltage

Answers for infrastructure and cities.


Your benefits at a glance Maximum functionality on minimum space – also for
intelligent transformer substations
 Comprehensive supply of gas-insulated switchgear for
secondary distribution grids At a time of growing cost and performance pressure it is
even more important to decide on the right technology,
 High cost-efficiency by climate- independent, durable
above all because switchgear represents an investment for
and maintenance-free switchgear
the next decades
 High switchgear availability and personal safety
Compactness, performance, climatic independence and
 Minimized space requirements by compact dimensions cost efficiency add to the central aspects of gas-insulated
medium-voltage switchgear from Siemens in order to
 High product quality from one of the pioneers of gas-
provide a future-proof investment: optimal personal and
insulated switchgear
functional safety, as well as reliable, maintenance-free
 Protection of investment by possible integration in smart operation.
distribution grids
 Reliable and competent support on site – from planning
to operation

2
Technical data

Technical features
Rated values up to 12kV, 21kA, 3s
Rated frequency 50 Hz
Busbar current up to 630 A
Feeder current up to 630 A
Busbars Single busbar
Rated power frequency withstand 28kV 38kV
voltage
Rated lighting impulse withstand 75kVp 95kVp
voltage
Insulation Gas-insulated
Switchgear vessel Hermetically enclosed
Type of switchgear Factory-assembled, type-tested, metal-enclosed switchgear
according to IEC 62271-200
Panel blocks consisting of 2, 3, 4 or 5 panels
Calssification according to IEC 62271-200
Partition class PM
Loss of service continuity category LSC 2
Accessibility to compartments Busbar compartment: Non-accessible
Switching-device compartment: Non-accessible
Cable compartment: Interlock-controlled
Degree of protection For switchgear enclosure [Indoor]: IP3X
For switchgear enclosure [Outdoor]: IP54
For gas filled vessel: IP67
Internal arc classification IAC A FLR 21kA, 1.0s
Dimensions
Block width depending on number 645mm, 955mm, 1265mm, 1575mm
and type of panels
Panel height 1620 mm
Panel depth Bottom explosion: 820 mm Top explosion: 918 mm
Standards
Switchgear IEC 62271-1
IEC 62271-100
Devices Circuit breakers IEC 62271-200
Disconnector & earthing switch IEC 62271-102
Switch-disconnector IEC 62271-103
Voltage detection systems IEC 61243-5
Degree of protection IEC 60529
Insulation IEC 60071
Instrument transformers Current transformer IEC 61869-2
Voltage transformer IEC 61869-3
Installation, erection IEC 61936-1

3
Product range for panels

Cable connection [K] Ring main [R] Vacuum Circuit Breaker [L]

Bus coupler [S] Line metering [ME1] Bus metering [ME2]

4
Product Range, Schemes and Dimensions

Typicals

Extensible RH With ME Non Panel Width


Both Side Left Side Right Side Extensible Non Extensible Extensible (Only Vessel)

 -R-  -R  R-  -R- NA NA 310

 -L-  -L  L-  -L-  L- NA 310

 -L430-  -L430  L430-  -L430-  L430- NA 310

 -K-  -K  K-  -K- NA NA 430

 -S- NA NA NA NA NA 620

 -RK-  -RK  RK-  -RK-  RK-  RK 620

 -RR-  -RR  RR-  -RR-  RR-  RR 620

 -RL-  -RL  RL-  -RL-  RL-  RL 620

 -LK-  -LK  LK-  -LK-  LK-  LK 620

 -RRR-  -RRR  RRR-  -RRR-  RRR-  RRR 930

 -RRL-  -RRL  RRL-  -RRL-  RRL-  RRL 930

 -RLR-  -RLR  RLR-  -RLR-  RLR-  RLR 930

 -RRRR-  -RRRR  RRRR-  -RRRR-  RRRR-  RRRR 1240

 -RRRL-  -RRRL  RRRL-  -RRRL-  RRRL-  RRRL 1240

 -LRRL-  -LRRL  LRRL-  -LRRL-  LRRL-  LRRL 1240

 -RRRRR-  -RRRRR  RRRRR-  -RRRRR-  RRRRR-  RRRRR 1550

 -LRRLL-  -LRRLL  LRRLL-  -LRRLL-  LRRLL-  LRRLL 1550

 -LLLLL-  -LLLLL  LLLLL-  -LLLLL-  LLLLL-  LLLLL 1550

NA  ME1* NA NA NA NA 630

NA  ME2* NA NA NA NA 630

“-” indicates extensibility/coupling side.


* Panel combinations with metering will always be with “ME” panel on extreme right side. No further right side extensibility is possible

5
Customer Benefits, Technical Data,
Design & Construction

Customer Benefits:
 Peace of mind  Design and Construction
• Gas insulated, metal enclosed, indoor/outdoor, • Ring feeders with three position switch disconnectors
Extensible/non- extensible factory assembled type (option: with auxiliary switch).
tested switchgear as per new IEC 62271-100/200. • Circuit breaker feeder with combined Vacuum
• Stringent quality standards as per ISO9001 and interrupter Dis-connector and earthing switch.
14001. • Capacitive voltage detection system for all feeders.
 Saves Lives • Protective self-powered relay & current transformers
for transformer protection.
• Internal arc fault tested switchgear including cable
compartment. • Individual panel / block type construction.
• Capacitive voltage detection system for verification of • Manual operating mechanism (option: with motor).
safe isolation from supply. • Cable connection from front.
• Logical mechanical interlocks.
 Increases Productivity
• Gas pressure monitoring via Manometer.
• All switching operations and cable access from the
front.  Options
• Safe to touch and hermitically sealed, gas tight, • Short circuit / earth fault indicators for ring feeders.
welded stainless steel primary enclosure, independent
• Shunt release for VCB feeders.
of environmental effects (dust, moisture, vermins
etc.). • Motor-operated ring & VCB feeders.
• Extensible on either sides. • Local/remote selector switch for motorized feeders.
• Provision for two runs of cable connection max
 Saves Money up to 3Cx300 sq.mm.
• Single switching element for load breaking,
disconnecting and earthing.
• Maintenance free operating mechanism accessible
outside the high voltage enclosure.
• Most compact individual panel/ block type
construction, ensuring minimum space requirement.

6
Notes

7
For more information, please contact:

Western Region Eastern Region Southern Region


Mumbai Kolkata Chennai
HO-B, Building No.2, 1st Floor 43, Shantipalli 9th Floor, Sigaphi Achi Building
130, Pandurang Budhkar Marg, Worli E.M. Bypass, Rash Behari Connector 18/3, Rukmani Lakshmipathi Road, Egmore
Mumbai - 400 018. Maharashtra (India) Kolkata - 700 042 Chennai - 600008
Tel.: +91-22-3967 7866 Tel.: +91-33-3093 9683 Tel.: +91-44-3342 6215

Vadodara
“Vishwakarma Bhavan”
Ground Floor, Maneja Works Northern Region International Sales
Vadodara - 390 013 Gurgaon Mumbai
Tel.: +91-0265-395 7701 3rd Floor, Tower - B 2nd Floor, R&D and Technology Centre
Pune Plot No. 6-A, Sector - 18 Kalwa Works, Thane-Belapur Road
701-705, ICC Trade Tower Maruti Industrial Area, HUDA Airoli Node
B Wing, Senapati Bapat Marg Gurgaon - 122 015, Haryana (India) Navi Mumbai - 400 708
Pune - 411 016, Maharashtra (India) Tel.: +91-124-383 7377 Tel.: +91-22-3326 5005
Tel.: +91-20-3046 6039

Siemens Ltd. Siemens Ltd. MS-01-000-006


Infrastructure & Cities Sector Infrastructure & Cities Sector
Low & Medium Voltage Division Low and Medium Voltage Division
Medium Voltage & Systems Medium Voltage & Systems
2nd Floor, R&D and Technology Centre Goa Works, L-6 Verna Industrial Estate
Kalwa Works, Thane-Belapur Road Verna Salcete, Goa - 403 722
Airoli Node, Navi Mumbai - 400 708 Tel.: +91-832-672 3000
Tel.: +91-22-3326 5005

Product upgradation is a continuous process. Hence, data


in this catalog is subject to change without prior notice. For
the latest information, please get in touch with our Sales
www.siemens.com/medium-voltage-devices Printed in India Offices.

You might also like