Thesis Bogun Inna
Thesis Bogun Inna
Thesis Bogun Inna
Inna Bogun
The purpose of the thesis is to research modern joint connections of steel struc-
tures in Finland and in Russia. Thesis includes the review of historical develop-
ment of steel structures and present types of connections in both countries and
focuses on principles of their work.
2
Table of contents
1 Introduction ..................................................................................................... 4
6.1 Supporting of the beams on the walls and reinforced concrete lining ..... 32
7.2 The bases with the milled end of the column rod ................................... 40
10 Conclusion .................................................................................................... 46
References........................................................................................................ 47
3
1 Introduction
The concept of "Metal structures" include their structural form, fabrication and
erection processes technology. On the one hand, the level of development of
metal structures is determined by the requirements for their national economy,
and on the other - by the possibility of a technical basis for the development of
metallurgy, metal-working, construction science and technology.
Metal structures are widely used in the construction of various buildings and
structures, because the quality that they acquire in the manufacturing process
directly affects the longevity and reliability of the final product.
Installation of metal structures - is a very important and crucial step in the con-
struction of buildings. And combination of these components is the most time-
consuming process, specifically selects for each design, depending on its char-
acteristics.
4
2 The history of metal construction
The metal used for a long time from the XII century, in the unique for that time
buildings (palaces, churches, and so on) in the form of fasteners and braces for
masonry. The first such structure are fasteners of the Assumption Cathedral in
Vladimir (1158). Pokrovsky Cathedral in Moscow - the first construction consist-
ing of rods, the tensile, bending and compression. There fastening supporting
floor and ceiling, strengthened to facilitate the work of bending braces. At that
time designers already knew that for fastener working on a bend, it is necessary
to apply the strip supplied to the edge and for the struts working in compression,
it is better to do a square cross-section (Figure 1).
Since the beginning of the XVII century the metal used in spatial dome structures
of the church leaders. The rods are made of forged constructions and bars con-
nected to the castle and the mountain buckles welding. Such designs can be
seen today in the refectory of the Trinity-Sergius Lavra in Sergiev
Posad (1696-1698), the building of the Grand Kremlin Palace in Moscow (1640),
the bell tower dome framework of Ivan the Great (1603), the framework of the
Kazan Cathedral dome in St. Petersburg with a span of 15 m (1805) and
others (1).
5
2.2 Cast iron construction
With the beginning of the XVIII began to master the founding process of cast iron
rods and parts. Bridges are constructed of cast iron. Connections are made of
cast-iron elements on the locks and bolts.
The first cast-iron construction in Russia is considered to cover the porch of the
Nevyansk tower in the Ural (1725). In 1784 the first iron bridge is built in St. Pe-
tersburg. Unique cast iron design on the 40-s of the ХIХ century is the dome of
St. Isaac's Cathedral, assembled from the individual stocks in the form of a con-
tinuous membrane (Figure 2).
The cast-iron arch span of 30 meters was used in the ceiling of the Alexandrinsky
Theatre in St. Petersburg (1827-1832).
In the 50-s years of the ХIХ century in St. Petersburg the Nicholas bridge with
eight arched spans from 33 to 47 m was built, it is the largest cast-iron bridge in
the world (1).
6
2.3 The metal profile and sheet rolling technology
From the 30-s of the ХIХ century to the 20-s of the ХХ century - is rapid techno-
logical advances in metallurgy and metalworking, the riveted joints are appeared.
In the 40-s of the ХIХ century is mastered the process of obtaining the metal
profile and sheet rolling. Steel is almost completely displaced the cast iron build-
ing structures. All steel construction for the next hundred years performed riveted.
Cast iron structure in the second half of the ХIХ century were only used in the
columns of high-rise buildings, railway stations ceilings landing stages, and so
on. That is, where the resistance to compression of cast iron are better than steel.
By the end of the ХIХ century in Russian industrial and civil buildings were built
mainly with brick walls and small spans, used to overlap the triangular metal
farms (Figure 3). First, the farms did not have diagonal braces, they appeared at
the end of the period under review.
In the second half of the XIX century, the metal bridge building has received a
significant development, where they began to apply the trusses with a triangular
lattice truss, the metal assortment of rolled sections appeared.
7
In the beginning of the XX century industrial buildings were built with a metal
frame that supports both the building envelope and the ways of overhead cranes.
Bearing element of the frame was the transverse frame consisting of columns
and beams (roof trusses). All steel structures are manufactured mostly riveted.
Steel began to oust cast iron. By the end of the century form of farms being im-
proved, there are diagonals, the connections instead of bolted on eyelets began
to perform riveted with the gussets (1).
At the end of the XIX century the lattice frame and arch designs for buildings of
significant overlap spans began to apply. For example, the Kiev railway station in
Moscow on the project of Shukhov (1913–1914) (Figure 4). Metal bridge con-
struction is developed (a bridge with lattice trusses through the Luga River, 1853).
Professor L. D. Proskuryanov introduced in the bridge trusses triangular and truss
bar lattice (across the Yenisei River Bridge).
8
Further development of metallurgy, mechanical engineering and other industries
requiring equipment of buildings with overhead cranes. First, they installed on the
platforms, but with the increase in carrying capacity it was better to build a build-
ing with a metal frame that supports the ways of overhead cranes. Transverse
frame became the main carrier element frame (Figure 5).
9
The structures he built sold the idea of pre-stressing structures and the construc-
tion of a suspension coating systems. Thus, he foresaw the future directions in
the development of metal structures (1). Its significant work in the area of the
reservoir structures, he developed new forms of reservoirs, their calculation and
methods for finding optimal parameters (Figure 7).
10
2.5 Typification, unification and standardization
By the end of 40-s of the XX century riveted construction is almost entirely re-
placed by welded, more economical. There are low-alloy and high-strength steel.
Besides steel, the aluminum alloys have begun to use, the density of which is
almost three times less.
It expands the range of metal structures. Large and diverse tasks for the devel-
opment of metal structures solved the efforts of design, research and production
teams – “Proektstalkonstruktsiya” (ProjectSteelStructures), “Promstroiproekt” (In-
dustrialConstructionProject) and “TSNIPS” (CSRIIB - Central Scientific and Re-
search Institute of Industrial Buildings), renamed later in “CNIISK” (CSRIBS -
Central Scientific and Research Institute of Building Structures) and high school
teams.
In this regard, first three-meter module bays introduced, which in the 50-s was
replaced by a six-meter. Typification also cover the spans of bridges, reservoirs,
gasholders, radio tower, radio mast.
Along with the improvement of structures forms and methods of calculation were
developed. Until 1950 the calculation was based on the method of allowable
stresses. This calculation is not fully reflected the actual construction work under
load, resulting in a metal-expenditure, therefore was designed limit state method.
There are computers that allows the designer to quickly find the optimum design
solutions.
11
initiators of the transition from the calculation of allowable stresses for the calcu-
lation of the ultimate limit state. In the field of electric welding large contribution
made by Professor E. O. Paton (1).
Metal structures are used in all major engineering structures with the significant
spans, heights and loads. Depending on the structural form and function metal
structures can be divided into eight types:
In the metal structures, different types of connections are used. In general, the
choice of a particular type of connection depends primarily on existing efforts and
constructive scheme of the junction elements.
12
In addition, the connection determined by the types of sections of elements that
converge in it, the technological and economic needs, as well as their architec-
tural expressiveness.
Figure 9. Dependence on the bending moment from the sectional rotation angle
13
In modern construction methods, structural elements that connected with each
other, account for two basic types:
• welded connections;
• bolting connections.
Other types of connections - rivets, glue, etc. - currently used in the industry is
very limited in special cases when it is justified.
There are two types of joints beams: the factory and the assembly (consolidated).
In the mounting joints, it is convenient to connect all the elements of the beam in
one section. This is called a universal joint.
14
Joints of rolling beams, factory and assembly, performed, as a rule, welded. Pos-
sible constructive solutions of are shown in the Figure 10.
The most simple and convenient is the direct connection of beams with the butt
joint (Figure 10, a). The joint must be welded faster to reduce shrinkage welding
stresses, so that cooling was going more evenly. Welding must be started with
less rigid element - wall. However, manual welding of the junction with the use of
conventional control methods of welding of the stretched beam chord in the junc-
tion will have a lower strength than the joint is, as the design resistance of the
weld butt joint to the stretching 𝑅𝑤𝑦 is less than the calculated resistance of the
base metal 𝑅𝑦 :
𝑅𝑤𝑦
𝑀𝑏𝑗 = 𝑀 ∗ ( 𝑅 ) = 0.85 ∗ 𝑀. (4.1)
𝑦
If necessary to make the joint in the section, which has a larger bending moment,
a straight butt joint of beams is making and enhancing the shelf with the overlays
(Figure 10, b). The bending moment in that junction is perceived by the butt
seams and overlays:
15
ℎ𝑜𝑙 - the distance between the overlays axes.
𝑀−𝑊∗𝑅𝑤𝑦
𝑁𝑜𝑙 = . (4.3)
ℎ𝑜𝑙
𝑁
𝐴𝑜𝑙 = 𝑅 𝑜𝑙 . (4.4)
𝑤𝑦
The corner seams that attach the overlay to the beam should be calculated on
the force in the overlay. To reduce welding stresses, these joints do not lead to
the joint axis by 25 mm on each side.
Almost all of the bending moment at this junction is transmitted through the
chords covers, and shear force is transmitted through a pair of covers on the wall.
Therefore, conventionally and more in to safety margin an effort in the patch and
the area of its cross-sectional area are defined by the formulas:
𝑀
𝑁𝑜𝑙 = ℎ . (4.5)
𝑜𝑙
𝑁𝑜𝑙
𝐴𝑜𝑙 = . (4.6)
𝑅𝑦
16
length at each end equal to at least three-quarters of the width of the narrower
plate concerned (Figure 11).
In the Russian and Finnish standards, such welding is carried out by the same
rules. Fillet welds along the perimeter of holes or slits may be used in the lap
welds joints in the cases provided to transmit forces in the plane of overlap, to
prevent buckling of the elements of the overlapping or structural compounds of
the elements.
The use of combined compounds in which part of the perceived frictional shear
connection, and part shear welds is allowed providing that the welding must be
17
performed after the final tightening of the bolts. The distribution of effort between
the friction and welded joints may be taken in proportion to their load-bearing
capacity or accept that the frictional connection receives a force from the constant
load, and weld receives a force from temporary load. The use of other compounds
in the combination of bolted connections is not allowed (Figure 12, Table 1) (6).
The difference between the Russian and Finnish standards is generally consists
in difference between the reduction coefficients β, that in the Russian norms is
varied from 0.7 to 1.9, while in the Finnish standards is varied from 0.8 to 1.0. In
Finland, welding is not used when mounting structures. The priority is the use of
bolting. One of the Finnish I-beam connection is shown in the
Figure 13.
18
Table 1: The results of verification
Internal forces
Percentage My, Mz,
Parameter Properties Value Qz, Qy,
of use, % N, kN kN kN
kN kN
m m
The cathe- 6.0
Seam S1 45.7 200.0* 0.0 80.0* 0.0 0.0
tus mm
The cathe- 7.0
Seam S2 81.3 200.0* 0.0 80.0* 0.0 0.0
tus mm
The
6.0
thickness
t1 mm
Plate 1 375.0 90.8 200.0* 0.0 80.0* 0.0 0.0
The size B
mm
110.0
The size H
mm
The
10.0
thickness
t2
mm
Plate 2 205.0 99.7 200.0* 0.0 80.0* 0.0 0.0
The size B
mm
155.0
The size H
mm
The quan-
6
tity
Bolts The num- 92,3 200.0* 0.0 80.0* 0.0 0.0
ber of ver- 2
tical rows
The size 10.0
- - - - - - -
L1 mm
The size 0.0
- - - - - - -
L2 mm
The size 40.0
- - - - - - -
L3 mm
*the efforts involved in the selection or checking of the appropriate parameters
19
5.1 Joints of the composite welded beams
Factory joints chords and walls of the composite welded beams connects sheets
to build them in the beam (Figure 14, a). The main type of welds sheets is a
splice. Splice compressed zones made using welding materials with full penetra-
tion of connected elements (which are displayed on the ends of the seams special
technological strips), are considered to have equal strength to the base metal,
they cannot count.
Figure 14. The factory (a) and the assembly (b) joints of composite beams
Joints stretched chords can also be considered as full-strength to the base metal
only if the above requirements and additional testing of physical methods of con-
trol. In the absence of physical quality control of stretched seam, it can be con-
sidered equal strength to the base metal, but lengthening it and making an
oblique at an angle of about 60° to the axis of the beam.
This complexity often makes production more appropriate the transfer of the di-
rect factory stretched butt weld in place of the beam, where the tension in the
chord does not exceed the calculated weld tensile strength. Factory joints com-
pressed zone and beam web is always doing direct.
On assembling the compressed zone and the wall always connect straight seam
butt joint and stretched chord oblique seam at an angle of 60°, as the installation
of physical methods of control are difficult. Such joint full-strength to the main
beam section and cannot be calculated.
20
Some overpotential of the wall, calculated against near the beam waist stretched,
usually neglected since this portion is located between the two beams elastically
working zones and it is impossible to ductile failure.
Each chord of the beam is desirable to overlap with the three overlays on the both
sides, and the wall of two vertical overlays, cross-sectional area of which should
not be less than the cross-sectional area of the overlapped element.
Figure 15. Assembly butt of the welded beams on the high-strength bolts
The weakening of the cross section of the beam zone accounted for as follows:
static load, if the net section area 𝐴𝑛 is less than 85% of the gross area,
𝐴𝑛 ≤ 0.85 ∗ 𝐴, then the conditional cross-sectional area is taken as
𝐴𝑐 = 1.18 ∗ 𝐴𝑛 . When the dynamic loads 𝐴𝑛 is accepted regardless of the amount
21
of attenuation. The weakening of the cross section can be adjusted with the cor-
responding arrangement of the bolts.
The bolts in the joint should be placed at a minimum distance from each other -
2.5 - 3 diameter of the holes for the bolts to reduce the size and weight of the
cover plates. Calculation of the joint of each element of the beam are separated,
and the bending moment is distributed between the belts and the wall in propor-
tion to their rigidity. Then the design effort in the zone can be determined by the
formulas:
The number the bolts to attach the cover plates to the chord of the beam:
22
where 𝑄𝑏ℎ - design shear force that can be perceived by a high-strength bolt.
Friction compounds in which the loads are transmitted through friction that occurs
at the contacting surfaces of connected components due to high-tension bolts
used:
𝛾ℎ - reliability coefficient.
The yield strength 𝑓𝑦𝑏 and the ultimate tensile strength 𝑓𝑢𝑏 for bolt classes 3,6 –
12,9 are given in Table 3. These values should be adopted as characteristic val-
ues in design calculations.
23
Table 3: Nominal values of the yield strength 𝑓𝑦𝑏 and the ultimate tensile
strength 𝑓𝑢𝑏 for bolts in Finland and in Russia (3,4,5)
Bolt class 3,6 4,6 4,8 5,6 5,8
Russian Finnish
R F R F R F R F R F
(R) (F)
𝑓𝑦𝑏 (N/mm2) 180 - 240 240 320 320 300 300 400 400
𝑓𝑢𝑏 (N/mm2) 300 - 400 400 400 400 500 500 500 500
Bolt class 6,8 8,8 9,8 10,9 12,9
Russian Finnish
R F R F R F R F R F
(R) (F)
𝑓𝑦𝑏 (N/mm2) 480 480 640 640 720 - 900 900 1080 -
𝑓𝑢𝑏 (N/mm2) 600 600 800 800 900 - 1000 1000 1200 -
The widespread use of high-strength bolts in the mounting connections led to the
flanges in bending elements, especially in light metal structures and rigid connec-
tion of the beams to the columns. Flange connections have a number of ad-
vantages over offset-stable compounds. In the flange joints are reduced con-
sumption of metal on the compound, the number of bolts and the complexity of
the connection.
The flange joint construction is shown in Figure 17, 18. To the ends of the con-
nected beams flanges are welded - thick sheets having holes for bolts. In the
interconnected flanges, these holes are inserted in the installation of high-
strength bolts and nuts are tightened, after which the joint is ready. Thus, the
installation process is extremely simple and not time consuming.
24
The operation of this connection is determined by the fact that the compressed
force in the junction zone beams are transmitted by direct contact of the flange
with each other, and the force zone stretched beams transmitted through the
flanges on the bolts, stretching them.
In accordance with the specifics of the joint the majority of the bolts are concen-
trated in the stretched beam chord, sometimes being located in two or three rows,
and in the area of compressed beams bolts are put on the maximum distance to
save the connection density. The distribution of tensile forces between the bolts
is very uneven and depends on the placing bolts and bending stiffness of the
flange. Thus, the ratio of effort per one bolt of the inner and outer connection
zones ranges from 1.1 at the thick flanges to 2.6 with thin flanges.
25
6 Supporting and connection of the beams
Connection beams with steel columns are the top bearing beams or beams abut-
ting laterally applied to the column. Such an adjunction can be a swivel, transmit-
ting only the support reaction of the beam, or rigid, transmitting to a column ex-
cept the support of the reaction is also the moment of pinching beams in the
column.
Swivel bearing is widely used in the majority of beam structures (Figure 19, Table
4) (6). Rigid connection is used in multi-storey buildings frameworks. Examples
of the bearing beams on the top and side of the column are shown in Figures 20
and 21. End of the beam in its bearing spot on the support is bearing with the
reinforcing ribs, while considering that all the supporting response is transmitted
to the support beams through the stiffening ribs. Transversing of the compression
on an unstiffened column is shown in Figure 23. In welded joints, the transverse
stiffeners should be aligned with the corresponding beam flange. In bolted joints,
the stiffener in the compression zone should be aligned with the centre of com-
pression (3).
26
Table 4: The results of verification
Internal forces
Percent-
My, Mz,
Parameter Properties Value age of Qy,
N, kN kN Qz, kN kN
use, % kN
m m
20.0 1000.0
Seam S1 Cathetus 86.7 0.0 -250.0* 0.0 0.0*
mm *
8.0 1000.0
Seam S2 Cathetus 98.7 0.0 -250.0* 0.0 0.0*
mm *
Thickness 25.0
t1 mm
130.0 1000.0
Plate 1 Size B1 98.5 0.0 -250.0* 0.0 0.0*
mm *
330.0
Size H1
mm
Thickness 40.0
t2 mm
-
260.0 1000.0 0.00 0.00 0.00
Plate 2 Size B2 95.3 250.00
mm 00* 0 0 0*
0*
245.0
Size H2
mm
Quantity 12 -
Number of 1000.0 0.00 0.00 0.00
Bolts 92.9 250.00
vertical 2 00* 0 0 0*
rows
0*
30.0
Size L1 - - - - - - -
mm
125.0
Size L2 - - - - - - -
mm
*the efforts involved in the selection or checking of the appropriate parameters
27
Figure 20. Supporting the beams on top of the column
28
In place of the transmission of the tangential stresses from the wall of the beam
to the supporting rib, stress distribution law of Zhuravsky on height is broken,
stresses are concentrated in the bottom wall, the degree of concentration de-
pends on the ratio of wall thickness and the cross-sectional area of the rib. With
relatively strong ribs and approval of local plastic deformation transfer of shear
stresses to the supporting rib can be assumed uniform throughout the height of
the wall. Stiffening rib for transmission support reaction is securely attached to
the wall of the welds and end stiffeners tight-fit to the lower chord of the beam.
𝐹
𝜎𝑝 = 𝐴 ≤ 𝑅𝑝 ∗ 𝛾𝑐 , (5.1)
𝑝
𝐴𝑝 - pressure area of the support ribs, in welded beams shall be equal to the
whole part of the rib area;
In addition to checking for crushing end support rib also checked the reference
section of the beam on the stability of the plane of the beam as the conditional
support rod, which includes the area of its section of the support ribs and part of
the beam wall with the width about 0.65 ∗ 𝑡𝑤 ∗ √𝐸/𝑅𝑦 in each direction and a
length equal to the height of the beam walls:
𝑁/(𝜑 ∗ 𝐴𝑤 ) ≤ 𝑅𝑦 ∗ 𝛾𝑐 , (5.2)
Attaching the supporting rib to the wall beam weld seams must be designed for
full support reaction of the beams with the maximum working length of the weld.
The hinge side abutment of beams in their constructive design, the work and the
calculation is not different from the bearing top of beams.
29
In the rigid beam to a column connection, support reaction of the beam is trans-
mitted to a column in the bolted version across the table or in a welded version -
through a special edge welded to the column wall and beam and the reference
point of the beam is passed through a similarly flanged joints and bolts stress on
the lower column of the beam chord or horizontal plates connecting beams chord
with a column (Figure 22, Table 5) (6).
30
Perce Internal forces
ntage
Paramete
Properties Value of My, Qz, Mz, Qy,
r
use, N, kN kNm kN kNm kN
%
The 30.0
thickness t4 mm
195.0 800.0
Plate 3 The size B 78.5 200.0* 80.0 0.0* 0.0*
mm *
330.0
The size H
mm
The wall 6.2
Beam 47.2 800.0 200.0 80.0* 0.0 0.0
thickness mm
The
number - 2 - - - - - -
of bolts
20.0
Size L1 - - - - - - -
mm
*the efforts involved in the selection or checking of the appropriate parameters
31
6.1 Supporting of the beams on the walls and reinforced concrete lining
When leaning of beams on the stone walls and reinforced concrete lining is usu-
ally used special steel bearings, which are used for evenly pressure distribution
of the beam over a larger area less durable than steel, bearing material (stone,
concrete).
In addition, the support part needs to ensure freedom of deformation of the ends
of the beam - rotating at the bending of the beam, the longitudinal displacement
from temperature and strain of power; otherwise in the support arises undesired
additional stresses.
In accordance with these requirements fixed and movable bearing parts are used
with the following types (Figure 24): With the spans, up to 20 m - flat base plates
(Figure 24, a and b.); up to 40 m - tangential support plates (. Figure 24, c); more
than 40 m - rollers, bearing parts (Figure 24, d.). Bearing parts are made of cast
or thick sheet steel.
To ensure the correct location of the rink in the supporting parts to the sides at-
tach anti-shift, and in the middle doing a flange that prevents the rink to move
across.
Calculated bending moment in the middle section of the slab:
32
𝐹 𝑎 𝐹𝑎
𝑀= ∗ = , (5.3)
2 4 8
2
𝑡𝑠𝑙
𝑊𝑠𝑙 = 𝑏 ∗ = 𝑀/(𝑅𝑦 ∗ 𝛾𝑐 ). (5.4)
6
To reduce rolling friction, roller diameter appoints approximate to the formula (not
less), mm:
𝑑 = 2 ∗ 𝑟 ≥ 130 + 𝑙/1000, (5.5)
where 𝑙 - span of the beam, checking on local collapse (pressure), according to:
𝐹
𝑟= , (5.6)
2∗𝑙∗𝑅𝑐𝑑 ∗𝛾𝑐
where 𝑙 - contact length of the cylindrical surface of the roller or tangential base
plate from the top plate;
𝑅𝑐𝑑 = 0.025 ∗ 𝑅𝑢 - calculated resistance ”diametrical compression of the rollers”
with free touch (4).
Connection of major and minor beams with each other are storey, in the same
level of the upper chords and with the lower position of the upper chords of sec-
ondary beams (Figure 25). Storey connection (Figure 25, a) is the simplest, but
because of the possible bending of the main beam belt it can only transfer small
support reactions.
Connection in one level and in the decreased level are able to transfer large bear-
ing reaction. The disadvantage of connection in the same level (Figure 25, b) is
the need to notch the top part and the wall part of the auxiliary beam.
These inconveniences can be avoided by welding at the factory to the end of the
auxiliary beam a short corner, and match it in the installation with bolts or welding
to the rib of the main beam (Figure 25, c).
33
Figure 25. Hinged connection of beams:
a) per floor; b) in the same level; c) with the decreased level
All of the connection beams worked as hinged. If necessary of the rigid connec-
tion of beams (Figure 26) are introduced “fishes” (at the same height of beams)
or “fishes" and a table (at a different height of beams).
In this connection arises not only the lateral force, transmitted to the screws that
attach the wall of the auxiliary beam to the edge of the main beam, or directly on
the table, but also the support moment that is transmitted through a special
lining - fishes or the fish and table.
34
Figure 27. Connection of the beams in Finland
At the hinge connection, base, for random moments, should be able to rotate
relative to a foundation, if the connection is rigid it is necessary to provide base
connection with the foundation is not permitting rotation.
With a relatively small computational effort in columns (4000 - 5000 kN) base with
traverses is applied. Traverse bears the load on the rod of the column and trans-
mits it to the base plate.
At the hinged of the column connection with foundation anchor bolts are placed
only for fixing the design position of the column and secure it in the installation
process. In this case the anchors are attached directly to the base support plate
(Figure 29, a and b). At rigid anchors connections are attached to the rod of the
column via remote console and tightened with a voltage close to the calculated
resistance, eliminating the possibility of turning of the column (Figure 29, c; Figure
30).
a) with the traverses; b) with the gussets; c) with a rigid support of the column to
the foundation; 1) traverse; 2) the console rib; 3) the diaphragm; 4) the anchor
washer
36
Figure 30. Connection of the pillar and the foundation in Finland
37
An example of the welded beam to the column connection is shown in Figure 31.
The results of verification are shown at Table 6 (6).
38
7.1 The bases with the traverses and cantilever ribs
The slab works as a plate on an elastic foundation, receives the pressure from
the branches, traverses and ribs. Experiments have shown that the pressure on
the foundation is unevenly distributed, with peaks at locations of the load trans-
mission. However, for simplicity, the pressure under the plate is taken a uniformly
distributed. The slab is calculated as a plate, loaded with uniformly distributed
pressure from below and simply supported on the foundation section of the rod
elements and the base of the column (branches, traverses, diaphragms, ribs,
etc.).
In accordance with the base structure, the plate may have areas, simply sup-
ported on four edges - contour 1, on three edges - contour 3, and console - con-
tour 2 (Figure 32).
Figure 32. Calculation schemes of the column base (figures in circles – the con-
tour number): 1) the traverses; 2) the slab base
39
7.2 The bases with the milled end of the column rod
At milled end of the column rod (Figure 33) a square plate is usually taken. As
the slab overhangs are not strengthened, the slab sometimes turns of consider-
able thickness, thicker than a conventional rolled sheet (40- 50 mm). In this re-
gard, perhaps the use of cast slabs.
After adjustment of the slab and filling it to the top edge of concrete, the rod of
the column is set on it. The slab milled at the end of the column rod, works like a
plate on an elastic foundation, perceiving pressure, concentrated in the area
bounded by the rod (Figure 33, b).
The exact calculation that takes into account the actual spatial flexure of the slab
for rectangular plate is very complicated, but it can be simplified by replacing the
rectangular slab and the section of the column equal of them in the area of circles
(Figure 33, c).
40
It possible to determine the bending moment in the plate on the column edge,
considering the trapezoidal section of the console plate with the width 𝑏 (at the
connection with the column):
𝑀 = 𝜎𝑓 ∗ 𝐴 ∗ 𝑐, (6.1)
where 𝜎𝑓 - tension in the basement under the base plate; 𝐴 - trapezoid area,
shaded in Figure 33, b; 𝑐 - the distance from the center of gravity of the trapezium
to the edge of the column.
The farm with the rods of the two parts, made up of T-profile, the connections on
the gussets design, which is placed between the corners. The rods are attached
to the lattice gusset flag seams (Figure 34). The force in the element distributed
between the seams on the butt and corner of feather is inversely proportional to
their distance from the axis of the rod.
41
The design of the support units depends on the type of supports (metal or con-
crete columns, brick walls, etc.) and the method of connection (hinged or rigid).
When free support farms on the underlying structure, a possible solution for the
support unit is shown in Figure 35. The farm pressure FR through the plate is
transferred to the support. The area of the slab Asl defined by the bearing capacity
of the support material.
The pressure from the farm to the support slab is transmitted through the gusset
and support column, forming a rigid support of cross-section.
Figure 35. Supporting farm connections of the paired parts: a) bearing on the
level of the lower chord; b) the same as the upper chord
Truss rigid support, typical for Finland is shown in Figure 36.
42
Figure 36. Truss rigid support
In the columns of constant height section crane beams and other structures are
based on the special console (Figure 37). When light-duty cranes are used con-
sole with one wall, welded to the rod of the column at the factory (if the dimen-
sions allow transportation). Console and seams of its fastening to the column
count on the bending moment M.
When transferring a great effort arrange a two-tier console (Figure 37, c).
43
Figure 37. Crane consoles:
a) with the continuous columns; b) with the lattice columns; c) a two-tier console
In the stepped columns crane beams supported by the ledge of the column. To
transfer the forces from the top of the column and of crane beams on the lower
part in place of the ledge traverse is arranged (Figure 39). When transferring of
force through the milled surface, the wall traverse is working to crumple.
Rail beam cantilever crane, typical for Finland is shown in Figure 38.
45
10 Conclusion
Farm connections and bearing joints of crane beams and columns should be ex-
amined in more detail, but overall analysis indicated that the connections are al-
most identical. The main differences consists in the difference between the coef-
ficients used in the calculations, as well as the classification of different ranges of
auxiliary members. Another important difference is that in Finland welding and
painting on-site is not applied, while it is very often used in Russia.
46
References
1. Y.I. Kudishin, E.I. Belenya, V.S. Ignateva and others. "Metal structures", 2007.
688 pp.
2. Mark Lawson, Artem Bilyk. “Steel structures in architecture”, 2015. 140 pp.
3. EN 1993 “Design of steel structures” Part 1-8: “Design of joints”
4. SP 16.13330.2011 “Steel structures”
5. SNiP 2-23-81 “Steel structures”
6. Lira soft - http://www.lira.com.ua/service/knots.php
7. EN 1990 “Basis of structural design”
8. http://gostrf.com/normadata/1/4293846/4293846982.pdf
9. http://eurocodes.jrc.ec.europa.eu/doc/2014_07_WS_Steel/presenta-
tions/07_Eurocodes_Steel_Workshop_WEYNAND.pdf
47