Online Catalogue: Current To: 2013-07-30
Online Catalogue: Current To: 2013-07-30
Online Catalogue: Current To: 2013-07-30
Current to: 2013-07-30
microsonic gmbh, hauert 16, d-44227 dortmund, telephone: +49 231 975151-0, fax: +49 231 975151-51, e-mail: info@microsonic.de
pico+ the "little guy" that
can do it all: 4 ranges, 3
output signals, 2
housing variants and 1
IO-Link interface.
Highlights
Variant with 90° angled head ::: for individual installation situations
IO ::: for support of the new industry standard
IO-- L i n k i n t e r f a c ee :::
Automatic synchronisation and multiplex operation ::: for simultaneous operation of up to ten sensors in close quarters
Basics
1 Push-- Pull switching output, pnp or npn basis ::: for all controllers
1 Push
Analogue output 4
Analogue output 4–– 20 mA or 0
20 mA or 0–– 10 V ::: for analogue distance measurements
4 Detection ranges with a measurement range of 20 mm to 1.3 m ::: individually appropriate for the use case
Temperature compensation ::: for exact measurement in temperature fluctuations
10
10–– 30 V operating voltage ::: for use on a variety of voltage networks
LinkControl ::: for configuration of sensors from the PC
The pico+ ultrasonic sensors
are a compact series with M18 threaded sleeves and only 41 mm in housing length. In addition to the variants with an axial
beam direction, there is also a housing variant with a 90° angled head and radial beam direction.
With four detection ranges from 20 mm to 1.3 m and three different output stages, this sensor family covers a wide range of
applications.
Sensors with the Push-Pull output stage support SIO and IO link modes. Sensors with analogue output are optionally
available with 4–20 mA current output or 0–10 V voltage output.
In SIO mode, sensors are configured using the microsonic teach-in procedure on pin 5.
For the pico+ sensor family
there are 2 output stages and 4 detection ranges available:
Sensors with switching output have three operating modes:
Single switching point
Two-way reflective barrier
Window mode
Teach
Teach-- in of a single switching point
Place object to be detected (1) at the desired distance
Apply +UB to pin 5 for about 3 seconds
Then apply +UB to pin 5 again for about 1 seconds
Teach-in of a switching point
Teach
Teach-- in of a two
in of a two-- way reflective barrier
way reflective barrier
with a fixed reflector
Apply +UB to pin 5 for about 3 seconds
Teach-in of a two-way reflective barrier
For configuration of a window
Place object at the near edge of the window (1)
Apply +UB to pin 5 for about 3 seconds
Then move the object to the far edge of the window (2)
Then apply +UB to pin 5 again for about 1 seconds
Teach-in of an analogue characteristic or a window with two switching points
NCC/NOC
and rising/falling analogue characteristic curve can also be set via pin 5.
One green and one yellow LED
indicate the state of the output and support microsonic teach-in.
LinkControl
optionally permits the extensive parameterisation of pico+ sensors. The LCA-2 LinkControl adapter available as an accessory
can be used to connect pico+ sensors to the PC.
Sensor connected to the PC via LCA-2 for programming
Easy to synchronise
A number of pico+ sensors can be run closely packed in applications synchronised to stop them influencing one another. To
this end, the sync mode has to be activated and all the sensors are to be electrically connected one to another with Pin 5.
If more than 10 sensors must be synchronised, this can be carried out with the SyncBox1, available as an accessory.
In instances of where a number of sensors are run at an IO-Link master, then the master's function is to assume
synchronisation (Pin 5 must not be wired under IO-Link operations).
Synchronised sensor cell in glass bottle production
IO
IO-- Link: The new standard at the fieldbus level
The IO-Link interface in the pico+ sensors gives you everything you need to implement continuous communication on all
levels of the system architecture, right down to the sensor. In this way, both machinery and equipment can be run in a more
productive manner. IO-Link can enormously simplify the startup and maintenance of either a machine or appliance.
IO
IO-- Link in detail
Following every switch-on, pico+ is in the SIO mode (Standard I/O mode) and functions just like any normal ultrasonic
proximity switch with push/pull output stage.
With the wake-up signal, an IO-Link enabled controller can transfer the pico+ into the communication or IO-Link modes. The
controller can now exchange both process and service data with the pico+.
An IO-Link master can have one or a number of inputs and outputs. Only one IO-Link device is attached at each input/output.
A standard 3-wire cable joins up the sensors and actuators. This non-shielded line can be up to 20 metres in length.
A mixed operation is possible thanks to complete compatibility to the SIO mode (Standard-IO mode): at a master a number of
sensors and actuators can be run in the IO-Link and others in the SIO mode.
Continuous communication permits process/service data to be transmitted between sensors/actuators and the controller.
Filling systems equipped with IO-Link
An IO-Link system consists of IO-Link devices – mainly sensors, actuators or combinations of them – a standard 3-wire
sensor/actuator cable and an IO-Link master.
More information on the IO-Link can be found in www.io-link.com
In the IO-Link mode the distances measured are cyclically transmitted to the master; thus the IO-Link mode can replace an
analogue output at no significant expense!
Following a sensor failure, the controller can automatically re-load all the settings into the new sensor.
Reduction in planning outlay achieved from a standardised integration of devices into the controller via a manufacturer-
independent IODD description file
Reduced startup times thanks to a centralized provision of data and parameters in the controller
Greater equipment availability levels coming from maximum transparency and system-wide diagnosis all the way down
into the device itself
Push-Pull output stage permits switching from SIO mode to IO-Link mode
Example of the system architecture
Product name pico+
Baud rate COM 2 (38,400 Bd)
Format of process 16 Bit, R, UNI16
data
Content of Bit 0: Q1 switch status; bits 1-15: Distance value with a resolution of 0.1 mm
process data
ISDU parameter Switch point 1, return detect point 1, switch point 2, return detect point 2, foreground suppression, (NC/NO) operation,
filter, filter strength, switching delay, interference noise suppression,
System commands activation/deactivation of teach-in on pin 5 teaching a switch point, teaching switch point + 8%, teaching a reflective barrier,
loading factory settings
Common IO-Link-specific data
Download IO-Link IODD library
scale drawing detection zone
1 x Push
1 x Push-- Pull 350 mm
operating range 30 - 250 mm
design cylindrical M18
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 320 kHz
blind zone 30 mm
operating range 250 mm
maximum range 350 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 3 mm
switching frequency 25 Hz
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+25/WK/F
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 350 mm
operating range 30 - 250 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities 90°-Winkelkopf
IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 320 kHz
blind zone 30 mm
operating range 250 mm
maximum range 350 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 3 mm
switching frequency 25 Hz
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities 90°-Winkelkopf
IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 600 mm
operating range 65 - 350 mm
design cylindrical M18
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 400 kHz
blind zone 65 mm
operating range 350 mm
maximum range 600 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 5 mm
switching frequency 8 Hz
response time 64 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+35/WK/F
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 600 mm
operating range 65 - 350 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities 90°-Winkelkopf
IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 400 kHz
blind zone 65 mm
operating range 350 mm
maximum range 600 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 5 mm
switching frequency 8 Hz
response time 64 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities 90°-Winkelkopf
IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 1,300 mm
operating range 120 - 1,000 mm
design cylindrical M18
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 200 kHz
blind zone 120 mm
operating range 1,000 mm
maximum range 1,300 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 20 mm
switching frequency 10 Hz
response time 80 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+100/WK/F
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 1,300 mm
operating range 120 - 1,000 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities 90°-Winkelkopf
IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 200 kHz
blind zone 120 mm
operating range 1,000 mm
maximum range 1,300 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 20 mm
switching frequency 10 Hz
response time 80 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities 90°-Winkelkopf
IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 350 mm
operating range 30 - 250 mm
design cylindrical M18
operating mode analogue distance measurements
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 320 kHz
blind zone 30 mm
operating range 250 mm
maximum range 350 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.10 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
current: 4-20 mA
switchable rising/falling
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+25/WK/I
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 350 mm
operating range 30 - 250 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode analogue distance measurements
particularities 90° angular head
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 320 kHz
blind zone 30 mm
operating range 250 mm
maximum range 350 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.10 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
current: 4-20 mA
switchable rising/falling
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
particularities 90° angular head
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 350 mm
operating range 30 - 250 mm
design cylindrical M18
operating mode analogue distance measurements
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 320 kHz
blind zone 30 mm
operating range 250 mm
maximum range 350 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.10 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+25/WK/U
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 350 mm
operating range 30 - 250 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode analogue distance measurements
particularities 90° angular head
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 320 kHz
blind zone 30 mm
operating range 250 mm
maximum range 350 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.10 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
particularities 90° angular head
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 600 mm
operating range 65 - 350 mm
design cylindrical M18
operating mode analogue distance measurements
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 400 kHz
blind zone 65 mm
operating range 350 mm
maximum range 600 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.17 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
current: 4-20 mA
switchable rising/falling
response time 70 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+35/WK/I
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 600 mm
operating range 65 - 350 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode analogue distance measurements
particularities 90° angular head
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 400 kHz
blind zone 65 mm
operating range 350 mm
maximum range 600 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.17 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
current: 4-20 mA
switchable rising/falling
response time 70 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
particularities 90° angular head
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 600 mm
operating range 65 - 350 mm
design cylindrical M18
operating mode analogue distance measurements
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 400 kHz
blind zone 65 mm
operating range 350 mm
maximum range 600 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.17 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
response time 70 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+35/WK/U
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 600 mm
operating range 65 - 350 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode analogue distance measurements
particularities 90° angular head
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 400 kHz
blind zone 65 mm
operating range 350 mm
maximum range 600 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.17 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
response time 70 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
particularities 90° angular head
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 1,300 mm
operating range 120 - 1,000 mm
design cylindrical M18
operating mode analogue distance measurements
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 200 kHz
blind zone 120 mm
operating range 1,000 mm
maximum range 1,300 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.38 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
current: 4-20 mA
switchable rising/falling
response time 100 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+100/WK/I
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 1,300 mm
operating range 120 - 1,000 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode analogue distance measurements
particularities 90° angular head
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 200 kHz
blind zone 120 mm
operating range 1,000 mm
maximum range 1,300 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.38 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
current: 4-20 mA
switchable rising/falling
response time 100 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
particularities 90° angular head
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 1,300 mm
operating range 120 - 1,000 mm
design cylindrical M18
operating mode analogue distance measurements
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 200 kHz
blind zone 120 mm
operating range 1,000 mm
maximum range 1,300 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.38 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
response time 100 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+100/WK/U
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
documentation (download)
pin assignment
scale drawing detection zone
1 x analogue 1,300 mm
operating range 120 - 1,000 mm
design cylindrical M18 with radially-arranged ultrasonic transducer (90°
angular head)
operating mode analogue distance measurements
particularities 90° angular head
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 200 kHz
blind zone 120 mm
operating range 1,000 mm
maximum range 1,300 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm to 0.38 mm, depending on the analogue window
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
response time 100 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: object in the window
particularities 90° angular head
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 250 mm
operating range 20 - 150 mm
design cylindrical M18
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities narrow sound field
IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 380 kHz
blind zone 21 mm
operating range 150 mm
maximum range 250 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 2.0 mm
switching frequency 25 Hz
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 30 g
further versions 90° angular head
further versions pico+15/WK/F
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities narrow sound field
IO-Link
documentation (download)
pin assignment
scale drawing detection zone
1 x Push
1 x Push-- Pull 250 mm
operating range 20 - 150 mm
design cylindrical M18
operating mode proximity switch/reflective mode
reflective barrier
window mode
particularities 90° angular head
narrow sound field
IO-Link
ultrasonic
ultrasonic -- s p e c i f i c
means of measurement echo propagation time measurement
transducer frequency 380 kHz
blind zone 21 mm
operating range 150 mm
maximum range 250 mm
angle of beam spread please see graphics detection zone
resolution/sampling rate 0.069 mm
reproducibility ± 0.15 %
accuracy ± 1 % (temperature drift internally compensated)
e l e c t r i c a l d a t a
operating voltage UB 10 - 30 V d.c., reverse polarity protection
voltage ripple ± 10 %
no-load current consumption ≤ 40 mA
type of connection 5-pin M12 initiator plug
outputs
output 1 switching output
Push-Pull: Imax = 100 mA (UB-3V)
switching hysteresis 2.0 mm
switching frequency 25 Hz
response time 32 ms
delay prior to availability < 300 ms
inputs
input 1 com input
synchronisation input
teach-in input
housing
material brass sleeve, nickel-plated, plastic parts, PBT
ultrasonic transducer polyurethane foam, epoxy resin with glass contents
max. tightening torque of nuts 15 Nm
class of protection to EN 60529 IP 67
operating temperature -25°C to +70°C
storage temperature -40°C to +85°C
weight 35 g
t e c h n i c a l f e a t u r e s / c h a r a c t e r i s t i c s
temperature compensation yes
controls com input
scope for settings Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
synchronization yes
multiplex yes
indicators 1 x LED green: working, 1 x LED yellow: switch status
particularities 90° angular head
narrow sound field
IO-Link
documentation (download)
pin assignment