that provides basic diagnostic § Plant operators and maintenance capability at a very low cost. It's technicians cannow alert predictive maintenance personnel of impending easy to use; designed for plant problems. mechanics and machinery § Monitor machinery traditionally too small or operators. in-frequently run to be included in a predictive maintenance program. The ST-101 will extend the capability of your § Small facilities can now implement a low operations and maintenance departments by cost predictive maintenance program. providing clear, on the spot insight of your machine condition. Without specialized Specifications vibration analysis training, your personnel can § Hand-held instrument for vibration assess your equipment condition and identify monitoring and screening sources of potential machine problems. § Designed for monitoring simple machinery, including fans and air handlers, centrifugal, The ST-101 goes beyond the idiot light screw and rotary pumps, and other approach of traditional hand-held vibration nonreciprocating machinery meters. Green, yellow and red bar graph § For use by plant mechanics and machinery segments show acceptable/unacceptable operators with limited vibration analysis representations of machine vibration. The bar experience graph displays indicate vibration levels based § Bar graphs use proprietary methods to on Acceleration, Velocity and Displacement indicate faults and diagnostic information measurements. Simple patterns on the bar § Mechanical defects indicated by easy-to- graph displays aid in the identification of understand bar graph patterns underlying machine problems. In addition, a § Provides pass/fail results, and additional numerical display allows the user to log these information for condition analysis readings for the purpose of historical data and § 4 digit readout reads acceleration, velocity & machine condition trending. displacement vibration levels, and information for trending The user simply attaches the magnetic mount § High-impact plastic case, water resistant accelerometer to the machine, selects the § Powered by 4 AA alkaline batteries operating speed of the machine and reads the A DLI ENGINEERING INNOVATION
display. Problems such as imbalance,
misalignment and rolling contact bearing wear have never before been so quick and easy to detect and identify.
253 Winslow Way West
Bainbridge Island WA 98110 206-842-7656 / 800-654-2844 Bar Graph Displays and Accessories Included Associated Machine • 100 mV/g single axis accelerometer • Magnetic accelerometer mount Conditions • 10' coiled accelerometer cable • Four AA alkaline batteries
Smooth running machine. All indicators green.
Mid bar graph higher than low or high bar graph
indicates high vibration level between 2-9 times rotation rate. Usually caused by high vane or blade rate, indicating flow or wear problems.
Equal low and mid bar graphs indicate high rotational
rate vibration level. Indicates balance or misalignment problem depending on orientation.
High frequency bar graph has much greater levels
than the mid bar graph. This is usually caused by failing rolling element bearings.
Call DLI Engineering today to find out how your
plant can benefit from the new DLI Watchman ST-101 Vibration Screening Tool.
Mid bar graph 2 segments higher than low bar graph
indicates high twice-rotational rate vibration level. This indicates misalignment. www.DLIengineering.com (800) 654-2844 • (206) 842-7656
253 Winslow Way West
Bainbridge Island WA 98110 206-842-7656 / 800-654-2844