Multi Bio700 User Manual
Multi Bio700 User Manual
Multi Bio700 User Manual
User Manual
Version: 1.1
Date: Nov. 2010
Multi-Biometric Access Control Terminal User Manual
II
Table of Contents
Table of Contents
I
Multi-Biometric Access Control Terminal User Manual
4. User Management.......................................................................34
II
Table of Contents
9. Auto Test......................................................................................80
Note: During enrollment and verification, try to have a relaxed unstrained face
1
MultiBio700 User Manual ZKTechnologyEU
During the enrollment, position your head such way that your face appears in the
center of the device display window. The device will prompt you how to move your
head.
Follow the voice prompts by first gently turning your head left, then right. Then
your head gently down, then up, and so on. The slight variations of the head angles
will help the device to better recognize your face when you attempt to verify.
2
MultiBio700 User Manual ZKTechnologyEU
Recommended fingers: The index finger, middle finger or the ring finger is
recommended; the thumb and little finger are not recommended (because they are
usually clumsy when pressing on the fingerprint collection screen).
Slanting Off-center
Please enroll and verify your fingerprint by using the proper finger placement
mode. We shall not be held accountable for any consequences arising out of the
degradation in verification performance due to improper user operations. We shall
reserve the right of final interpretation and revision of this document.
3
MultiBio700 User Manual ZKTechnologyEU
Touch the screen with one of your fingertips or the edge of a fingernail, as shown in
the following figure. A broad point of contact may lead to inaccurate pointing.
When the touch screen is less sensitive to the touch, you can perform a screen
calibration through the following menu operations. Press [Menu] -> [Auto Test] ->
[Calibration] on the screen and a cross icon will be displayed. After you touch the
center of the cross at five locations on the screen correctly, the system will
automatically returns to the main menu. Press [Exit] to return to the initial interface.
For details, see the description in 9. Auto Test.
Smear or dust on the touch screen may affect the performance of the touch screen.
Therefore, try to keep the screen clean and dust-free.
4
MultiBio700 User Manual ZKTechnologyEU
1. Enter numbers: Press the [User ID] key. The system will automatically display
the number input interface. After entering the user ID, press [OK] to save or press [X]
to cancel and return to the previous interface.
2. Enter Text: Press the [Name] key. The system will automatically display the text
input interface. After entering the user name, press [X] to save and return to the
previous interface.
5
MultiBio700 User Manual ZKTechnologyEU
3. Modify parameters: Press the default value of a parameter and the system will
automatically switch to another value of this parameter.
6
MultiBio700 User Manual ZKTechnologyEU
1. Front View
LED Indicator
Touch Screen
Touch keys
Camera
Push Buttons
Fingerprint Sensor
Reset Button
USB Port
7
MultiBio700 User Manual ZKTechnologyEU
Date
Screen Shortcut
Time
Attendance Status
Face Image
8
MultiBio700 User Manual ZKTechnologyEU
9
MultiBio700 User Manual ZKTechnologyEU
1. 1: N fingerprint verification
In this fingerprint verification mode, the device
compares current fingerprint collected by the fingerprint
sensor with all fingerprint data on the device.
1. The default main interface is the fingerprint
verification mode. See the figure on the right.
2. Press your finger on the fingerprint sensor by adopting
the proper finger placement. For details, see 1.3 Finger
Placement.
3. If the verification is successful, the device will prompt
“Verified”.
4. If the verification is not successful, the device will
prompt “Please try again”.
10
MultiBio700 User Manual ZKTechnologyEU
11
MultiBio700 User Manual ZKTechnologyEU
12
MultiBio700 User Manual ZKTechnologyEU
13
MultiBio700 User Manual ZKTechnologyEU
14
MultiBio700 User Manual ZKTechnologyEU
Note: RF means ID card verification. Only the products with the built-in ID
card module support the ID card verification.
15
MultiBio700 User Manual ZKTechnologyEU
mode. Compare the face in a proper way. For details, see 1.1 Standing Position,
Posture and Face Expression.
(4) If the verification is successful, the device will prompt “Verified”. The system
will return to the main interface if the verification is not passed within 20 seconds.
Otherwise, the FACE&FP combination verification can perform such as FACE (1: N)
+ FP, PIN + FACE (1:1) + FP, PIN + FP (1:1) + FACE etc. The operation is similar
to the procedure introduced before.
16
MultiBio700 User Manual ZKTechnologyEU
2. Main Menu
There are two types of rights respectively granted to two types of users: the
Ordinary users and administrators. Ordinary users are only granted the rights of
face, fingerprint, password or card verification, while administrators are granted
access to the main menu for various operations apart from having all the privileges
granted to ordinary users.
Press [Menu] on the initial interface to access the main menu, as shown in the
following figure:
17
Multi-Biometric Access Control Terminal User Manual
information.
Comm.: Through this submenu, you can set related parameters for communication
between the device and PC, including the IP address, gateway, subnet mask, baud
rate, device No. and communication password.
System: Through this submenu, you can set system-related parameters, including
the basic parameters, interface parameters, fingerprint, face and attendance
parameters, Keyboard definitions, Access settings, firmware update etc. to enable
the device to meet the user’s requirements to the greatest extent in terms of
functionality and display.
Data Mgt.: Through this submenu, you can perform management of data stored on
the device, for example, deleting the attendance records, all data, clear administrator,
restore to factory settings and query records.
Date/Time: Through this submenu, you can set the alarm time and duration, or set
the Bell.
Auto Test: This submenu enables the system to automatically test whether functions
of various modules are normal, including the screen, sensor, voice, face, keyboard,
clock tests and screen calibration.
Dn/Upload: Through this submenu, you can download user information and
attendance data stored in the device through a USB disk to related software or other
fingerprint recognition equipment.
Sys Info.: Through this submenu, you can browse the records and device
information.
Any user can access the main menu by pressing the [Menu] key if the system
does not have an administrator. After administrators are configured on the device, the
device needs to verify the administrators’ identity before granting them access to the
main menu. To ensure device security, it is recommended to set an administrator
when using the terminal initially. For detailed operations, see 3.7 Modify User Rights .
18
MultiBio700 User Manual ZKTechnologyEU
3. Add User
19
Multi-Biometric Access Control Terminal User Manual
20
MultiBio700 User Manual ZKTechnologyEU
21
Multi-Biometric Access Control Terminal User Manual
3. 3 Enrolling a Fingerprint
22
MultiBio700 User Manual ZKTechnologyEU
23
Multi-Biometric Access Control Terminal User Manual
3. 4 Enrolling a Password
24
MultiBio700 User Manual ZKTechnologyEU
3. 5 Enrolling a Face
25
Multi-Biometric Access Control Terminal User Manual
Tip: A valid group No. contains 1 to 24 digits. Please remember your own
group No.
26
MultiBio700 User Manual ZKTechnologyEU
27
Multi-Biometric Access Control Terminal User Manual
Note: There are two types of rights respectively granted to two types of users:
the ordinary users and administrators. Ordinary users are only granted the rights
of face, fingerprint, or password verification, while administrators are granted the
access to the main menu for various operations apart from having all the privileges
granted to ordinary users.
1. On the [Add User] interface, press [Role: User] to change the user to an
administrator.
2. After the modification is done, the interface is as shown below. Press [Save] to
save the current information and return to the previous interface; press [Exit] to
return to the previous interface without saving the current information.
28
MultiBio700 User Manual ZKTechnologyEU
29
Multi-Biometric Access Control Terminal User Manual
Press [User Access] on the [Add User] interface to display the user access settings
interface.
User Access settings are to set the user’s rights to verify and open the door, such as
the Verify Type, Time Zone and Duress FP management.
1. Verify Type:
(1) Group Verify Mode: If the user uses the group verify mode that he belong to.
(2) Individual verify mode: Select the verification mode for this user instead of the
group verify mode. That will not affect other users in this group.
Note:
(1) Only the products with the built-in ID card module support the ID card
verification.
(2) For the verify type, please refer to Appendix 4 Multi-combination Authentication
Mode. Only some types of devices support Multi-combination authentication mode.
30
MultiBio700 User Manual ZKTechnologyEU
2. Time Zone:
(1) Group Time Zone: If the user uses the group time zone that he belong to.
(2) Individual time zone: Select the time zone of this user instead of the group time
zone. That will not affect other users in the group.
3. Duress FP:
Enroll a new duress fingerprint or cancel an existing one.
In any situation, only if the enrolled duress fingerprint is
verified, it will trigger the duress alarm.
Duress FP management:
(1) Register Duress FP:
Press [Reg. Duress FP] on the [User Access] interface to
display the [Enroll Fingerprint] interface. On the
displayed [Enroll Fingerprint] interface, place your
finger on the fingerprint sensor properly according to the
system prompt. For details, see 1.3 Finger Placement.
31
Multi-Biometric Access Control Terminal User Manual
32
MultiBio700 User Manual ZKTechnologyEU
33
MultiBio700 User Manual ZKTechnologyEU
4. User Management
34
MultiBio700 User Manual ZKTechnologyEU
Press a user name from the list to enter the [User Info] interface.
The User ID cannot be modified, and the other operations are similar to those
performed in add a user. You can re-enroll your fingerprint and face image, change
your password, modify the management rights and group number.
For example: Change the user rights from Administrator to ordinary user. As shown
below.
35
Multi-Biometric Access Control Terminal User Manual
On the [User Info] interface, you can delete all or partial user information.
1. Press [Delete] to delete a user.
2. On the displayed interface, click [YES] to delete the current user or [NO] to return
to the previous interface.
3. On the [User Info] interface, press [Name], [Fingerprint], [Face] or [Password] to
delete the related user information and to re-enroll the new information follow the
device prompt.
36
MultiBio700 User Manual ZKTechnologyEU
37
MultiBio700 User Manual ZKTechnologyEU
5. Communication Settings
You can set related parameters for the communication between the device and PC,
including the IP address, gateway, communication mode, subnet mask, baud rate,
device ID, and communication key.
38
MultiBio700 User Manual ZKTechnologyEU
When the device communicates with the PC over Ethernet, you need to check the
following settings:
IP Address: The IP address is 192.168.1.201 by default and can be changed as
required; the IP address of the device and that of the PC cannot be duplicated.
Subnet Mask: The subnet mask is 255.255.255.0 by default and can be changed as
required.
Gateway: The gateway is 0.0.0.0 by default. If the device and the PC are not located
in the same network segment, you need to set the gateway.
When the device communicates with the PC over serial ports (RS232/RS485), you
need to check the following settings:
RS232: This parameter is used to enable or disable the RS232 communication. If the
RS232 communication cables are used, set this parameter to “ON”.
RS485: This parameter is used to enable or disable the RS485 communication. If the
RS485 communication cables are used, set this parameter to “ON”.
Baud Rate: This parameter is used to set the baud rate for the communication
between the device and the PC. It includes five options: 9600, 19200, 38400, 57600,
and 115200. The higher baud rate is recommended for the RS232 communication to
achieve high speed communication, while the lower baud rate is recommended for
the RS485 communication to achieve stable low-speed communication.
Device ID: This parameter is used to set the ID of device from 1 to 254. If the
RS232/RS485 communication is adopted, you need to enter the device ID on the
software communication interface.
Comm. Key: To enhance the security of attendance data, you can set a password for
the connection between the device and PC. Once the password is set, you can
connect the PC with the device to access the attendance data only after entering the
correct password. The default password is 0 (that is, no password). Once a password
is set, you need to enter this password before connecting the PC software with the
device; otherwise, the connection is unsuccessful. 1 to 6 digits passwords are
supported.
39
Multi-Biometric Access Control Terminal User Manual
Considering the massive data including the fingerprint and face templates
stored in the device, it is recommended to transfer the data between the device
and PC over network to enhance the transfer speed.
40
MultiBio700 User Manual ZKTechnologyEU
41
Multi-Biometric Access Control Terminal User Manual
The system has a built-in Wiegand 26-bits format. Press [Wiegand Format], and
select “Standard Wiegand 26-bits”.
The composition of the Wiegand 26-bits format contains 2 parity bits and 24 bits for
output contents (“User ID” or “Card Number”). The binary code of 24-bits represent
up to 16,777,216 (0–16,777,215) different values.
1 2 25 26
Even parity User ID/Card Number Odd parity bit
Definition of Fields:
Field Meaning
Even parity bit Judged from bit 2 to bit 13. The even parity bit is 1 if the
character has an even number of 1 bit; otherwise, the even
parity bit is 0.
User ID/ Card User ID/Card Number (Card Code, 0–16777215)
Number (bit 2-bit Bit 2 is the Most Significant Bit (MSB).
25)
Odd parity bit Judged from bit 14 to bit 25. The odd parity bit is 1 if the
character has an even number of 1 bit; otherwise, the odd
parity bit is 0.
For example, for a user with the user ID of 12345, the enrolled card number is
0013378512 and the failed ID is set to 1.
1. When the output is set to “User ID”, the Wiegand output is as follows upon
successful verification:
00000000000110000001110011
Even parity bit User ID = Binary code of 12345 Odd parity bit
42
MultiBio700 User Manual ZKTechnologyEU
2. When the output is set to “Card Number”, the Wiegand output is as follows upon
successful verification:
11100110000100011110100000
Even parity bit User ID = Binary code of 0013378512 Odd parity bit
3. The Wiegand output is as follows upon verification failure:
00000000000000000000000010
Note: If the output contents exceed the scope allowed for the Wiegand format,
the last several bits will be adopted and first several bits are automatically discarded.
For example, the user ID 888 888 888 is 110 100 111 110 110 101 111 000 111 000
in binary format. Wiegand26 only supports 24 bits, that is, it only outputs the last 24
bits, and first 6 bits “110 100” are automatically discarded.
43
Multi-Biometric Access Control Terminal User Manual
The system has a built-in Wiegand 34-bits format. Press [Wiegand Format], and
select “Standard Wiegand 34-bits”.
The composition of the Wiegand 34-bits format contains 2 parity bits and 32 bits for
output contents (“User ID” or “Card Number”). The binary code of 32-bits represent
up to 4,294,967,296 (0–4,294,967,295) different values.
1 2 33 34
EvenParit User ID/Card Number Odd parity bit
yBit
For example, for a user with the user ID of 123456789, the enrolled card number is
0013378512 and the failed ID is set to 1.
1. When the output is set to “User ID”, the Wiegand output is as follows upon
successful verification:
0000001110101101111001101000101011
44
MultiBio700 User Manual ZKTechnologyEU
Even parity bit User ID = Binary code of 123456789 Odd parity bit
2. When the output is set to “Card Number”, the Wiegand output is as follows upon
successful verification:
0000000001100110000100011110100001
Even parity bit User ID = Binary code of 0013378512 Odd parity bit
3. The Wiegand output is as follows upon verification failure:
0000000000000000000000000000000010
45
Multi-Biometric Access Control Terminal User Manual
Apart from the two built-in formats Wiegand 26-bits and Wiegand 34-bits, the
system also supports the format customization function to meet individualized
requirements.
The customized format consists of two character strings: the data bits and parity
bits. These two character strings need to be defined separately. Data bits define the
number of binary bits output by Wiegand as well as the meaning of each bit. The
data bits output by Wiegand can be a card number (C), site code (s), facility code (f),
manufacturer code (m) and parity bits (p). Parity bits define the check mode of each
bit in data bits and ensure the correctness of data bits during transfer through the
parity check. The parity bits can be set to odd check (o), even check (e) and both odd
check and even check (b). There is a one-to-one correspondence relationship
between the data bits and parity bits.
For example, the Wiegand26 can be customized as follows:
Definition of data bits: pssssssssccccccccccccccccp
Definition of parity bits: eeeeeeeeeeeeeooooooooooooo
46
MultiBio700 User Manual ZKTechnologyEU
Display Input
Backspace
Confirm Input
Clear Input
47
Multi-Biometric Access Control Terminal User Manual
Wiegand37a
Data bits: pmmmmsssssssssssscccccccccccccccccccp
Parity bits: oeobeobeobeobeobeobeobeobeobeobeobeoe
Note: Wiegand37a consists of 37 bits. The first bit is the odd parity bit of bits 3, 4, 6,
7, 9, 10, 12, 13, 15, 16, 18, 19, 21, 22, 24, 25, 27, 28, 30, 31, 33, 34 and 36; the 37th
bit is the odd parity bit of bits 2, 4, 5, 7, 8, 10, 11, 13, 14, 16, 17, 19, 20, 22, 23, 25,
26, 28, 29, 31, 32, 34 and 35; bits 4, 7, 10, 13, 16, 19, 22, 25, 28, 31 and 34
participate in both odd and even parity check. Bits 2 to 5 are manufacturer code; bits
6 to 17 are the site code; bits 18 to 36 are the card number.
48
MultiBio700 User Manual ZKTechnologyEU
Wiegand37
Data bits:
pmmmffffffffffssssssccccccccccccccccp
Parity bits:
eeeeeeeeeeeeeeeeeeooooooooooooooooooo
Note: Wiegand37 consists of 37 bits. The first bit is the even parity bit of bits 2 to 18;
the 34th bit is the odd parity bit of bits 19 to 36; the second to the fourth bits are the
manufacturer code; the 5th to the 14th bits are facilitate code; the 15th to the 20th bits
are the site code; the 21st to the 36th bits are the card number.
Wiegand50
Data bits: pssssssssssssssssccccccccccccccccccccccccccccccccp
Parity bits:
eeeeeeeeeeeeeeeeeeeeeeeeeooooooooooooooooooooooooo
Note: Wiegand50 consists of 50 bits. The first bit is the even parity bit of bits 2 to 25;
the 50th bit is the odd parity bit of bits 26 to 49; the second to the 16th bits are the site
code; the 17th to the 49th bits are the card number.
49
Multi-Biometric Access Control Terminal User Manual
50
MultiBio700 User Manual ZKTechnologyEU
6. System Configuration
Through the [System] menu, you can set system-related parameters, including the
General, Display, Fingerprint, Face, Log settings, Shortcut Def, Access Control Set,
and Firmware Update, to enable the device to meet user requirements to the greatest
extent in terms of functionality and display.
51
Multi-Biometric Access Control Terminal User Manual
52
MultiBio700 User Manual ZKTechnologyEU
53
Multi-Biometric Access Control Terminal User Manual
54
MultiBio700 User Manual ZKTechnologyEU
Always Show: Display the fingerprint on the screen in enrolling and verifying
process.
Never Show: Never display the fingerprint on the screen in any case.
55
Multi-Biometric Access Control Terminal User Manual
56
MultiBio700 User Manual ZKTechnologyEU
face algorithm when their quality is higher than the threshold; otherwise, it filters
these face images.
Note: Improper adjustment of the Exposure, Gain and Quality parameters may
severely affect the performance of the device. Please adjust the Exposure parameter
only under the guidance of the after-sales service personnel from our company.
57
Multi-Biometric Access Control Terminal User Manual
58
MultiBio700 User Manual ZKTechnologyEU
2. If you want to cancel the shortcut key, press [Status] to enter the edit interface,
select the value to “Undefined”.
3. Edit the item [Code], select [Label] (Six attendance state option). Select the state
of [Auto Switch], the interface as shown above.
4. Press [Save] to save the modification and exit.
59
Multi-Biometric Access Control Terminal User Manual
60
MultiBio700 User Manual ZKTechnologyEU
Notice: System default time zone 1 as whole day open (namely, the new
61
Multi-Biometric Access Control Terminal User Manual
62
MultiBio700 User Manual ZKTechnologyEU
2. Edit holiday
Select the holiday to be edited and enter the edit
interface. The edit operation is similar to add holiday.
After editing, press [Save] to save and return to the
previous interface.
3. Delete holiday
Select the holiday to be deleted. Press [Delete] to popup
the confirm interface as follows. Select [Yes] to delete
this holiday, otherwise select [No] to cancel the
operation.
63
Multi-Biometric Access Control Terminal User Manual
Note:
(1) RF means ID card verification. Only the products with the built-in ID card
module support the ID card verification.
(2) For Multi-combination verification, please refer to Appendix 4
64
MultiBio700 User Manual ZKTechnologyEU
Notice:
1. If the holiday is valid, only when there is an intersection between group zone and
holiday time zone, can the group member open the door.
2. If the holiday is invalid, the access control time of group member won’t be
affected by holiday.
2. Edit group time zone
Press the line to be edited, and enter the edit interface.
After editing, press [Save] to save the current
information and return to the previous interface; press
[Exit] directly to return to the previous interface without
saving the current information.
65
Multi-Biometric Access Control Terminal User Manual
66
MultiBio700 User Manual ZKTechnologyEU
Make various groups into different access controls to achieve multi-verification and
improve security. An access control can be made up of 5 groups at most.
1. Add Unlock Combination
(1) Enter holiday add Combination Setting interface,
press the key to edit the items.
(2) Press the touch screen number key to set the value,
after setting, press [OK] to save, and press [X] for exit
and return to the previous interface.
(3) Press [Save] to save the current information and
return to the previous interface; press [Exit] directly to
return to the previous interface without saving the
current information.
67
Multi-Biometric Access Control Terminal User Manual
68
MultiBio700 User Manual ZKTechnologyEU
69
Multi-Biometric Access Control Terminal User Manual
Notice:
1. If the Time Zone of normally open or normally closed has been set, please switch
door sensor to no, otherwise it will produce alarm signal during Normal close Time
Zone or Normal open Time Zone.
2. If the normally open or normally closed Time Zone is not defined yet by the time,
the equipment will prompt that you to define the Time Zone, and transfer you to the
Time Zone interface to add.
70
MultiBio700 User Manual ZKTechnologyEU
71
Multi-Biometric Access Control Terminal User Manual
72
MultiBio700 User Manual ZKTechnologyEU
6.8 Update
If you need the firmware upgrade file, please contact our technical
support personnel. Generally the firmware upgrade is not recommended.
73
MultiBio700 User Manual ZKTechnologyEU
7. Data Management
Notice: The employee information and attendance records will not be deleted
during restoration to factory settings.
5. Query Record: After check-in successfully, the employee’s attendance records
are saved in the device. You can easily query these attendance records.
User ID: Enter the user ID of the employee to query. If this field is left blank, you
can query the attendance records of all the employees. If you enter a user ID, you
can query the attendance records of this employee.
Query Time Period: Select a time period to query, including the customized time
74
MultiBio700 User Manual ZKTechnologyEU
period, yesterday, this week, last week, this month, last month, and all time periods.
Start and End: When you select a customized time period, you need to input a start
time and an end time. When you select other options for the time period, the start
and end time will be automatically adjusted to the related time.
After setting the query conditions, press [Query] and the records that meet the
specified query conditions will be displayed on screen.
Select the row where the desired record is located, you can query the detailed
information of this record.
For example, press User ID and enter the edit interface, input the ID number and
press [Query], the query result will display as below.
75
Multi-Biometric Access Control Terminal User Manual
76
MultiBio700 User Manual ZKTechnologyEU
8. Date/Time Setting
77
Multi-Biometric Access Control Terminal User Manual
Lots of companies need to ring their bells to signal the start and end of work shifts,
and they usually manually ring their bells or use electric bells. To lower costs and
facilitate management, we integrated the time bell function into the device. You can
set the alarm time and duration for ringing the bell based on your requirements, so
that the device will automatically play the selected ring tone and triggers the relay at
the alarm time, and stop playing the ring tone after the set duration.
Press [Bell] on the [Date/Time] menu to display the bell setting interface, as shown
in figure below.
1. Add a bell
1) The displayed bell setting interface lists all the bells. Click [Add] to display the
[Add] interface.
2) On the [Add] interface, set the following parameters:
Bell Time: This parameter is used to set a time point when the device automatically
plays a bell ring tone every day.
Bell Date: This parameter is used to set which day the device automatically plays a
bell ring tone.
78
MultiBio700 User Manual ZKTechnologyEU
Ring Tone: This parameter is used to set the bell ring tone.
Volume: This parameter is used to set the volume of ring tone.
Repeat: This parameter is used to set the alarm times.
State: This parameter is used to set whether to enable the bell.
Bell Type: You can select between internal ringing and external ringing. For internal
ringing, the ring tone is played by the loudspeaker of the device. For external ringing,
the ring tone is played by an external electric bell that is connected with the device.
Notice: Only some models have this function. If you need it, please contact our
business representative or technician.
79
MultiBio700 User Manual ZKTechnologyEU
9. Auto Test
The auto test enables the system to automatically test whether functions of various
modules are normal, including the screen, sensor, voice, face, keyboard and clock
tests.
1. Test Screen: The device automatically tests the display effect of the color TFT
display by displaying full color, pure white and pure black and checks whether the
screen displays properly. You can continue the test by touching the screen or exit it
by pressing [Exit].
2. Test Fingerprint: The device automatically tests whether the fingerprint sensor
works properly by checking whether the fingerprint images are clear and acceptable.
When the user places his/her finger on the sensor, the collected fingerprint image is
displayed on the screen in real-time. Press [Exit] to exit the test.
3. Test Voice: The device automatically tests whether the voice files are complete
and the voice quality is good by playing the voice files stored in the device. You can
continue the test by touching the screen or exit it by pressing [Exit].
4. Test Face: The device automatically tests whether the camera works properly by
80
MultiBio700 User Manual ZKTechnologyEU
checking whether the collected face images are clear and acceptable. Press [Exit] to
exit the test.
5. Test Keyboard: The device tests whether every key on the keyboard works
normally. Press any key on the [Keyboard Test] interface to check whether the
pressed key matches the key displayed on screen. The keys are dark-gray before
pressed, and turn blue after pressed. Press [Exit] to exit the test.
6. Test Time: The device tests whether its clock works properly by checking the
stopwatch of the clock. Touch the screen to start counting, and touch it again to stop
to check whether the counting is accurate. Press [Exit] to exit the test.
7. Screen Calibration:
You can perform all the menu operations by touching the screen with one of your
fingers or a touch pen. When the touch screen is less sensitive to the touch, you can
perform a screen calibration through menu operations.
The Screen Calibration Operation:
(1) Press [Menu] on the initial interface to display the
main menu interface.
(2) Press [Calibration] on the [Auto Test] interface to
display the screen calibration interface.
(3) Touch the center of the cross “+”.
(4) Repeat Step 3 following the move of the “+” icon to
different locations on the screen.
(5) Touch the center of the cross at five locations on the
screen correctly. When the message “Calibrating screen,
pls wait……” is displayed on screen, the calibration
succeeds and the system automatically returns to the
main menu. If the calibration fails, the system recalibration will start from Step 3.
81
MultiBio700 User Manual ZKTechnologyEU
Through the [Dn/Upload] menu, you can download user information and attendance
data stored in a USB disk to related software or other fingerprint recognition
equipment.
1. Download Transactions: Download all the attendance data from the device to a
USB disk.
2. Download User: Download all the user information, fingerprints and face images
from the device to a USB disk.
3. Download user photos: Download the employees’ photos from the device to a
USB disk.
4. Upload User: Upload the user information, fingerprints and face images stored in
a USB disk to the device.
5. Upload User Photo: Upload the JPG documents that are named after the user IDs
and stored in a USB disk to the device, so that user photos can be displayed after the
employee passes the verification. See Appendix 3 Photo ID Function.
82
MultiBio700 User Manual ZKTechnologyEU
83
MultiBio700 User Manual ZKTechnologyEU
12. Appendix
①Keyboard Area
②Text Display Area
③Text List Area
④Exit
⑤Delete
⑥Enter
⑦Space
⑨Character/English
⑩Upper/Lower Case
84
MultiBio700 User Manual ZKTechnologyEU
85
Multi-Biometric Access Control Terminal User Manual
Wiegand26 defines the interface between the card reader and controller used in the
access control, security and other related industrial fields. Wiegand26 helps
standardize the work of the card reader designers and controller manufacturers. The
access control products manufactured by our company are also designed by
following this protocol.
Digital Signals
The figure below is a sequence diagram in which the card reader sends digital
signals in bit format to the access controller. In this sequence diagram, Wiegand
follows the SIA’s access control standard protocol for the 26-bit Wiegand card
reader (one pulse time ranges between 20 us and 100 us, and the pulse jump time
ranges between 200us and 20ms). Data1 and Data0 are high level (larger than Vol)
signals till the card reader prepares to send a data stream. The asynchronous
low-level pulse (smaller than Vol) generated by the card reader is sent to the access
control panel (The saw-tooth wave as shown in Figure below) through Data1 or
Data0. Data1 and Data0 pulses will neither overlap nor be generated synchronously.
The table below lists the maximum and minimum pulse width (a consecutive pulse)
and pulse jump time (time between pulses) allowed by the F series fingerprint access
control device.
86
MultiBio700 User Manual ZKTechnologyEU
87
Multi-Biometric Access Control Terminal User Manual
Note:
1) The length of a user name cannot exceed 24 digits.
2) The recommended size of a user photo is less than 30 kbit.
3) The uploaded new user photo will overwrite the existing photo in related to the
user ID.
4) To download user photos, select USB Disk Management -> Download ->
Download User Photos. A folder with the name of “photo” will be automatically
created on the USB disk, and all downloaded user photos are stored under this
folder.
88
MultiBio700 User Manual ZKTechnologyEU
Besides this function only is owned by the fingerprint access control machine that
has been appointed, most of the fingerprint machines only have two ways to verify
by fingerprint and password, we provide a personal or group Multi-combination
Authentication Mode for high security Access control area, verification type main
include five elements that are User Number (PIN), Fingerprint (FP), Face (FACE),
Password (PW) and RF card (RF), which can combine into multi-combination.
Note: The RF card is used for ID card verification, the function of ID card
verification only is validity in the machine which ID card function is provided with.
1) PIN++FACE(1:1)
2) FP(1:N)
3) PIN+PW+“OK”
4) RF(1:N)
FP&PW FP + PW are verified
1) FP(1:N)+PW+“OK”
89
Multi-Biometric Access Control Terminal User Manual
2) PIN+FP(1:1)+PW+“OK”
3) PIN+PW+“OK”+FP
FP&RF FP + RF are verified
1) RF+FP(1:1)
2) FP(1:N)+RF
3) PIN+FP(1:1)+RF
FACE&FP FACE + FP are verified
1) FP(1:N)+FACE
2) FACE(1:N)+FP
3) PIN+FACE(1:1)+FP
4) PIN+FP(1:1)+FACE
FACE&PW FACE + PW are verified
1) FACE(1:N)+PW+“OK”
2) PIN+FACE(1:1)+PW
3) PIN+PW+FACE
FACE&RF FACE + RF are verified
1) FACE(1:N)+RF
2) PIN+FACE(1:1)+RF
3) RF(1:N)+FACE
FP Only FP is verified.
1) PIN+FP(1:1)
2) FP(1:N)
PW Only PW is verified
PIN+PW+“OK”
RF Only RF is verified
RF(1:N)
FACE&PIN FACE + PIN are verified
PIN+FACE(1:1)
90
MultiBio700 User Manual ZKTechnologyEU
FP/RF FP or RF is verified
1) PIN+FP(1:1)
2) RF(1:N)
3) FP(1:N)
PW/RF FP or RF is verified
1) PIN+PW+“OK”
2) RF(1:N)
FP/PW FP or PW is verified
1) PIN+FP(1:1)
2) FP(1:N)
3) PIN+PW+“OK”
PIN&FP PIN + FP are verified
PIN+FP(1:1)
FP&PW&RF FP + PW + RF are verified
1) FP(1:N)+PW+“OK”+RF
2) PIN+FP(1:1)+PW+“OK”+RF
3) RF(1:N)+PW+“OK”+FP
4) PIN+ PW+“OK”+FP(1:1)+RF
PIN&FP& PW PIN + FP + PW are verified
1) PIN+PW+“OK”+FP(1:1)
2) PIN+FP(1:1)+PW+“OK”
FP & RF/PIN FP + PIN, or FP + RF are verified
1) RF+FP(1:1)
2) FP(1:N)+RF
3) PIN+FP(1:1)
FACE&FP&RF FACE + FP + RF are verified
1) FACE(1:N)+FP+RF
2) FP+FACE(1:1)+RF
91
Multi-Biometric Access Control Terminal User Manual
3) RF(1:N)+FACE+FP
4) PIN+FP(1:1)+FACE+RF
5) PIN+FACE(1:1)+FP+RF
FACE&FP&PW FACE + FP + PW are verified
1) FACE(1:N) +PW+“OK”+FP
2) FP+PW+“OK”+FACE(1:1)
3) PIN+FP(1:1) +PW+“OK”+FACE
4) PIN+FACE(1:1) +PW+“OK”+FP
5) PIN+PW+“OK”+FP+FACE
Note: For combined verification, it is better to enroll all the elements in need
for using verification mode, or verification will fail.
For example: User “A” use fingerprint for enrollment, while password is used for
verification, then the user cannot pass the verification.
92
MultiBio700 User Manual ZKTechnologyEU
【overview】
Sometimes, some illegal people follow the other one into the gate, which will cause
the security problems. To prevent such risks, this function is enabled. The In record
must match the Out record, or the gate won’t open.
This function needs two machines to work together. One is installed inside of the
door (master machine hereinafter), the other is installed outside of the door (slave
machine hereinafter). Wiegand signal communication is adopted between the two
machines.
【Working principle】
The master machine has Wiegand In and slave machine has Wiegand Out functions.
Connect Wigand Out of slave machine to Wiegand In of master machine. Wiegand
output from slave machine must not own machine ID. The number sent to master
machine from slave machine must be found in the master machine.
【Function】
Judge whether it is anti-pass back according to user’s recent in-out record. In record
and out record must be matched. This machine supports out, in, or out-in anti-pass
back.
93
Multi-Biometric Access Control Terminal User Manual
When the master machine is set as “out anti-pass back”, if user wants to come in and
go out normally, his recent record must be “in”, or he cannot go out. Any “out”
attempt will be refused by “anti-pass back” function. For example, a user’s recent
record is “in”, his second record can be “out” or “in”. His third record is based on
his second record. Out record and in record must match.(Notice: If customer has no
record before, then he can come in but cannot go out. )
When the master machine is set as “in anti-pass back”, if the user wants to come in
and go out normally, his recent record must be “out”, or he cannot go out. Any out
record will be “anti-pass back refused” by the system. (Notice: If the customer has
no former record, then he can go out, but cannot come in).
When the master machine is set as “out-in anti-pass back”, if the user wants to come
in and go out normally, if his recent record is “out” and “in”, then his next record
must be “in” and “out”.
【operation】
1. Select model
Master machine: The machine with Wiegand in function, except for F10 reader.
Slave machine: The machine with Wiegand Out function.
2. Menu setting
Anti-pass back
There are four options: in/out anti-pass back, out anti-pass back, in anti-pass back,
and none.
Out anti-pass back: Only user’s last record is in-record, can the door be open.
In anti-pass back: Only user’s last record is out-record, can the door be open.
Device status: There are three options: Control-in, control-out and none
Control-in: When it is set, the verified records on the device are in-records.
Control-out: When it is set, the verified records on the device are out-records.
None: When it is set, close the device’s anti-pass back function.
3. Modify device’s Wiegand output format
When the two devices are communicating, only the Wiegand signals without device
94
MultiBio700 User Manual ZKTechnologyEU
95
Multi-Biometric Access Control Terminal User Manual
Dear Customers:
Thank you for choosing the hybrid biometric products designed and manufactured
by us. As a world-renowned provider of biometric technologies and services, we pay
much attention to the compliance with the laws related to human rights and privacy
in every country while constantly performing research and development.
We hereby make the following statements:
1. All of our fingerprint recognition devices for civil use only collect the
characteristic points of fingerprints instead of the fingerprint images, and
therefore no privacy issues are involved.
2. The characteristic points of fingerprints collected by our products cannot be
used to restore the original fingerprint images, and therefore no privacy issues
are involved.
3. We, as the equipment provider, shall not be held legally accountable, directly or
indirectly, for any consequences arising due to the use of our products.
4. For any dispute involving the human rights or privacy when using our products,
please contact your employer directly.
Our fingerprint products for police use, or development tools support the collection
of the original fingerprint images. As for whether such a type of fingerprint
collection constitutes an infringement of your privacy, please contact the
government or the final equipment provider. We, as the original equipment
manufacturer, shall not be held legally accountable for any infringement arising
thereof.
The law of the People’s Republic of China has the following regulations regarding
the personal freedom:
1. Unlawful arrest, detention or search of citizens of the People's Republic of
China is prohibited; infringement of individual privacy is prohibited.
96
MultiBio700 User Manual ZKTechnologyEU
97
MultiBio700 User Manual ZKTechnologyEU
The Environment Friendly Use Period (EFUP) marked on this product refers to the safety
period of time in which the product is used under the conditions specified in the product
instructions without leakage of noxious and harmful substances.
The EFUP of this product does not cover the consumable parts that need to be replaced on
a regular basis such as batteries and so on. The EFUP of batteries is 5 years.
Chip resistor × ○ ○ ○ ○ ○
Chip capacitor × ○ ○ ○ ○ ○
Chip inductor × ○ ○ ○ ○ ○
Chip diode × ○ ○ ○ ○ ○
ESD components × ○ ○ ○ ○ ○
Buzzer × ○ ○ ○ ○ ○
Adapter × ○ ○ ○ ○ ○
Screws ○ ○ ○ × ○ ○
○: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for
this part is below the limit requirement in SJ/T11363-2006.
×: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous
materials for this part is above the limit requirement in SJ/T11363-2006.
Note: 80% of the parts in this product are manufactured with non-hazardous environment-friendly
materials. The hazardous substances or elements contained cannot be replaced with
environment-friendly materials at present due to technical or economical constraints.
98