E-Link Eagle User Interface Manual - 05212014 - B

Download as pdf or txt
Download as pdf or txt
You are on page 1of 57

E-Band Communications, LLC

E-Link Eagle
User Interface
Manual

E-Band Communications, LLC


May 22, 2014
2014

1 of 56
Copyright Notice and Disclaimer
©2014, E-Band Communications, LLC. All Rights Reserved.

No portion of this publication may be reproduced, copied or distributed


without the written consent of E-Band Communications, LLC (E-Band).
E-Band reserves the right to update or change the material of this
publication at any time without notice. E-Band has made every effort to
ensure that the information and the instructions contained in the
publication are correct and is not responsible for any errors or
omissions due to typing, printing or editing of this document.
Purchasers of E-Band products should make their own evaluation to
determine the suitability of each product for their specific application.
E-Band obligations regarding the use or application of its products shall
be limited to those commitments to the purchaser set forth in its
Standard Terms and Conditions of Sale for a delivered product.
This publication has been prepared for professional and properly trained
personnel, and the customer assumes full responsibility when using the
information herein.
The software provided and described in this guide is furnished under
and is subject to a license and nondisclosure agreement.
The E-Band logo is a trademark of E-Band Communications, LLC and
other specific product names mentioned herein are trademarks of their
respective companies.

E-Band Communications, LLC.


10095 Scripps Ranch Ct., Suite A
San Diego, CA 92131
Tel: +1-858-408-0660
Fax: +1-858-408-0655
e-mail: support@e-band.com
www.e-band.com

2 of 56
Table of Contents

Contents
1 General Information ................................................................................ 5
1.1 Introduction ...................................................................... 5
1.2 Product Compatibility .......................................................... 5
1.3 Safety and Regulatory ........................................................ 6
1.4 RF Compatibility and Regulatory Information ......................... 8
2 Warranty ............................................................................................... 10
3 Product Description and overview ......................................................... 11
3.1 E-Link Eagle Description ..................................................... 11
4 Local Management Access ..................................................................... 13
4.1 Tools and equipment needed to access and manage the radio. 13
4.2 Accessing the Web GUI ...................................................... 13
4.3 Connection to E-Link Eagle ................................................. 14
4.4 Radio Setup ...................................................................... 17
4.5 Setting the Radio’s IP Address ............................................ 18
4.6 Detailed Status Page ......................................................... 20
4.7 Configuration Page ............................................................ 22
4.8 Installation Page ............................................................... 27
4.9 Diagnostics Page ............................................................... 28
4.10 Security Page ................................................................. 29
4.11 Factory Page .................................................................. 30
4.12 Logs Page ...................................................................... 31
5 Eagle - VLAN Management Configuration .............................................. 33
5.1 Configuration Steps ........................................................... 33
6 QoS ........................................................................................................ 38
6.1 Configuring QoS no VLAN ................................................... 39
6.2 Configured QoS with VLAN tag only ..................................... 41
6.3 Configuring Quality of Service using DSCP ............................ 46
7 Software Update Procedures ................................................................. 49
7.1 Tools and Methods ............................................................ 49
7.2 Update Using Web GUI ...................................................... 49
7.3 Update Using Command Line Interface ................................ 52
7.4 Update FPGA/Modem Firmware ........................................... 54

3 of 56
Table of Figures
Figure 1: E-Link Eagle Point to Point System ..............................................5
Figure 2: E-Link Eagle Power and Data Connection .................................. 14
Figure 3: E-Link User ID/Password Screen .............................................. 15
Figure 4: Opening Screen Details .......................................................... 16
Figure 5: Accessing Radio Management Using HTTP Session ..................... 33
Figure 6: Opening Screen after Login ...................................................... 34
Figure 7: VLAN Port Configuration ......................................................... 36
Figure 8: VLAN ID 10 Port Setting Example ............................................ 36
Figure 9: IP Configuration Settings ........................................................ 37
Figure 10: Port State Overview Page ....................................................... 37
Figure 11: VLAN Port Membership Example ............................................. 38
Figure 12: QoS Control List Configuration ............................................... 39
Figure 13: QoS Control List Configuration ............................................... 39
Figure 14: Create QCE Configuration...................................................... 40
Figure 15: QoS Control List Configuration ............................................... 40
Figure 16: Select VLAN Membership....................................................... 41
Figure 17: Ports Configured to Aware and Tagged Only Traffic .................. 42
Figure 18: QoS Control List, Class Setting .............................................. 43
Figure 19: QoS Sample Control List ....................................................... 43
Figure 20: Port Scheduler ..................................................................... 44
Figure 21: QoS Egress Port Scheduler .................................................... 45
Figure 22: QoS Egress Port Schedulers................................................... 45
Figure 23: QCE with Queue Redirection .................................................. 47
Figure 24: QCE with Port 8 (250MHz Channel Bandwidth) ......................... 48
Figure 25: PC File Upload Selection Screen ............................................. 51
Figure 26: Firmware/Modem Update Progress Indication .......................... 52
Figure 27: CLI Periodic Status Message .................................................. 53

4 of 56
1 General Information
1.1 Introduction
This manual provides an overview and general introduction to the user
interface options of the E-Link Eagle millimeter wave radio. It contains
the information necessary to set up, operate, and maintain a link.
E-Band’s E-Link product family provides network designers with a
point-to-point broadband radio that delivers broadband wireless
Ethernet IP-based services.
Requiring no server room installation, the all-outdoor ready E-Link
Eagle installs quickly and delivers the lowest cost per gigabit wireless
solution in the industry. E-Link is the ideal choice wherever rapid
deployment of Carrier-grade Ethernet service is required.
The E-Link system consists of a radio unit and antenna.
Figure 1 illustrates the E-Link Eagle system.

Figure 1: E-Link Eagle Point to Point System

1.2 Product Compatibility


While every effort has been made to verify operation of this product
with an array of different communications products and networks, E-
Band makes no claim of compatibility between its products and other
vendors’ equipment. Carefully evaluate this product’s applicability and

5 of 56
projected performance characteristics in the communications
environment in which it will be used.

1.3 Safety and Regulatory


1.3.1 United States of America
The following general safety precautions must be observed during all
phases of operation and service of the products covered in this manual.
Failure to comply with these precautions or with specific warnings
elsewhere in this manual can void the warranty.

CAUTION
 Do not stand directly in front of an energized antenna.
 Do not install or operate the equipment in the presence of or
close to flammable fumes or gases. Operating any electrical
instrument in such an environment is a safety hazard.
 E-Band radios meet all applicable U.S.A. FCC safety requirements
for general population exposure to radio frequency emissions;
however, it is best to avoid prolonged, unnecessary exposure to
the waveguide opening while it is operating.
 Please refer to Articles 810 and 830 of the National Electrical
Code, ANSI/NFPA No. 70, for installations in the U.S.A for
information regarding proper grounding and applicable lightning
protection for DC cables.
 Outdoor equipment must be properly grounded to provide
protection against voltage surges and built-up static charges. In
the event of a short circuit, grounding reduces (but does not
eliminate) the risk of electrical shock.
 Changes or modifications not expressly approved (in writing) by
E-Band’s Engineering and/or Product Management personnel can
void the warranty. For installations in all other countries,
implement protection in accordance with the safety standards
and regulatory requirements of the country where the equipment
is to be installed.

CAUTION Protection from Lightning


Article 810 of the US National Electric Department of Energy Handbook
1996 specifies that radio and television lead-in cables must have
adequate surge protection at or near the point of entry to the building.

6 of 56
The code specifies that any shielded cable from an external antenna
must have the shield directly connected to a 10 AWG wire that
connects to the building ground electrode.
Protection from RF Emissions
CAUTION
It is hazardous to look into or stand in front of an active antenna
aperture. Do not stand in front of or look into an antenna without first
ensuring the associated transmitter or transmitters are switched off. Do
not look into the waveguide port of an ODU when the radio is active.
LASER SAFETY NOTICE
CAUTION
This product complies with CFR 1040.10, 1040.11 and EN (IEC) 60825-
1 regulations and safety standards. The product may include a Class 1
laser utilized as a fiber optic driver. Class 1 lasers do not emit radiation
at known hazardous levels.
However, it is recommended that maintenance or service personnel
should never look at an open fiber end or connector that is carrying a
live signal. During use, this optical fiber communications system is
completely enclosed except if an accidental break occurs in the system
cable, or if the patch cable becomes accidentally disconnected from the
demarcation box.
There are no controls or adjustments other than power ON/OFF that
may be accessed by the user.
 Risk of Personal Injury from Fiber Optics
 DANGER: Invisible laser radiation. Avoid direct eye exposure to
the end of a fiber, fiber cord, or fiber pigtail. The infrared light
used in fiber optics systems is invisible, but can cause serious
injury to the eye.
 WARNING: Never touch exposed fiber with any part of your body.
Fiber fragments can enter the skin and are difficult to detect and
remove.

CAUTION CAUTION: Use of controls or adjustments or performance of procedure


other than those specified in this Manual may result in hazardous
radiation exposure.

7 of 56
CAUTION CONSTRUCTION SAFETY NOTICE
Note that each locality has its own codes of safety and construction.
Equipment installations must comply with these codes. It is the
installer/user’s responsibility to understand what codes apply and to
ensure that the installation conforms to these codes.

Input Power Requirements


Do not turn on the power before reading E-Band’s product
documentation. This device has a -48 VDC direct current input at less
than 100VA.

NOTE
NOTE: The power requirements for the E-Link Eagle is-48VDC at 45 W.

1.4 RF Compatibility and Regulatory Information


This device, in accordance with FCC Part 15B and Part2, complies with
Part 15 Subpart J, and Part 101 Subpart Q, of the U.S.A. Federal
Communication Commission rules.
In the U.S.A., millimeter wave radio transmission equipment operating
in the 71-76 and 81-86 GHz frequency ranges must be registered with
the FCC as provided for in Part 101 of the FCC regulations.
Proper operating licenses must be obtained to operate radios in the 71-
86 GHz frequency band in the U.S.A. and most other countries.
Check with your country’s wireless regulatory body for licensing in your
area. Do not install the E-Link without an approved license.
For additional information on licensing or regulatory information, please
contact E-Band at support@e-band.com .

1.4.1 European Union

This product has been designed to comply with CE markings in


accordance with the requirements of European Directive 1995/5/EC.
This product has been designed to comply with the requirements of
European Directives.

8 of 56
This equipment must be permanently earthed for protection and
functional purposes. To make a protective earth connection, use the
grounding point located on the System ODU using a minimum amount
of 16AWG grounding cable or according to local electrical code.

This apparatus is intended to be accessible only to authorized


personnel. Failure to prevent access by unauthorized personnel will
invalidate any approval given to this apparatus.

This product is in full compliance with the following standards:

 RF EN 302 217-3 1.3.1


 EMC EN 301 489-4
 Safety IEC 60950-1, -22
 Operation EN 300 019-1-4 Class 4.1E
 Storage EN 300 019-1-1 Class 1.2
 Transportation EN 300 019-1-2 Class 2.2

9 of 56
2 Warranty
LIMITED WARRANTY

E-Band Communications, LLC warrants to BUYER ONLY that the products will
be substantially free from defects in material or workmanship for 12 months
after date of shipment to Buyer. Products purchased from Seller which do not
comply with the warranty and are returned to the Seller during such period
will be repaired or replaced at Seller's option. Buyer may return the products,
or components thereof, only with prior written authorization and assignment
of a Return Material Authorization (RMA) number by Seller. Buyer will bear
the cost of freight and insurance for return of goods to Seller; provided,
however, that all products not eligible for repair, replacement or credit will be
returned to Buyer, transportation collect. Buyer must return any such
products in the original container/packing, which shall conspicuously bear the
RMA number Buyer obtains from Seller prior to return. SELLER MAKES NO
OTHER WARRANTIES WITH RESPECT TO THE PRODUCTS OR ANY SERVICES
AND DISCLAIMS ALL OTHER WARRANTIES, INCLUDING WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
NONINFRINGEMENT. The above warranty does not extend to any Product that
is modified or altered, is not maintained to Seller's maintenance
recommendations, is operated in a manner other than that specified by Seller,
or is subject to abuse, misuse, accident, disaster, alterations, neglect or other
improper treatment. Seller will make the final determination as to the
existence of any cause of any alleged defect. Buyer's sole remedy with
respect to any warranty or defect is as stated above. Seller neither assumes
nor authorizes any other person to assume for Seller any other liability in
connection with the sale of products under this contract.

LIMITATION OF LIABILITY.NOTWITHSTANDING ANYTHING ELSE IN THIS


AGREEMENT OR OTHERWISE, SELLER WILL NOT BE LIABLE UNDER ANY
PROVISION OF THIS AGREEMENT OR UNDER ANY CONTRACT, NEGLIGENCE,
STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY (A) FOR ANY
AMOUNTS IN EXCESS IN THE AGGREGATE OF THE AMOUNTS PAID TO SELLER
HEREUNDER DURING THE TWELVE MONTH PERIOD PRIOR TO DATE THE
CAUSE OF ACTION AROSE, OR (B) FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES, OR (C) FOR COST OF PROCUREMENT OF
SUBSTITUTE GOODS, TECHNOLOGY OR SERVICES.

10 of 56
3 Product Description and overview
The E-Link Eagle product is designed to provide the network operator
the flexibility of providing first mile access, as well as backhaul, for
gigabit Ethernet networks.
 “Plug & Play” simple installation and alignment
 Outdoor only capability/no Indoor unit
 Optical and Copper interface for Gigabit Ethernet tributary
 Local Management Interface based on HTML
 Remote management using SNMP v1,2 &3
 -48 VDC Input (via either POE or direct using a two wire
connection)
 Direct slip-fit Antenna Mount
 Low latency
 Frequency agile

3.1 E-Link Eagle Description


The E-Link Eagle millimeter wave radio is a point-to-point fixed
wireless, ultra high capacity broadband access product operating in the
upper millimeter wave spectrum from 71-76 GHz and 81-86 GHz. The
E-Link Eagle carries Gigabit Ethernet payloads (full duplex). The E-Link
Eagle deploys quickly and inexpensively. In most locations, the E-Link
Eagle model will have 99.995% availability at approximately 1 mile.
Actual path performance is dependent upon local climate conditions.
Please contact E-Band or your authorized representative for additional
information.

11 of 56
The E-Link Eagle is available in two models:

Model Data Rate Application


E-Link Eagle EP 83 - 1,000Mbps
Long Range Gigabit Ethernet
transport with an over-the-
air composite data of from
83 to 1,000 Mbps. This model
provides 5x10/100/1000Base
Ethernet ports plus 2 SFP
ports for either fiber
connectivity.
Optional
83 - 2000 Mbps Optional software upgrades
Or to 2000 and 3000 Mbps
throughputs are available.
83 - 3000 Mbps
E-Link Eagle SP 83 - 1,000Mbps Long Range Gigabit Ethernet
transport with an over-the-
air composite data from 83 -
1,000 Mbps including an in-
band management channel.
Only 1 10/100/1000Base
Ethernet port with PoE is
provided.
Table 1: E-Link Eagle Models

12 of 56
4 Local Management Access
There are two methods of accessing local management features.
The first method is through the Web Graphical User Interface, and
is the primary subject of this document.
The second method is through a Command Line Interface, (CLI).
The command line allows access to some features that are not
available through the Web GUI.
This document will explain how to access the radio through both
methods, but will only include command line details that are used in
the initial configuration and basic operation of the radio.

4.1 Tools and equipment needed to access and manage the


radio.
4.1.1 A PC or laptop with a web browser and with telnet enabled

4.1.2 Use an Ethernet cable, TIA 568B pin out, to connect the PC to the
radio

4.2 Accessing the Web GUI

13 of 56
4.3 Connection to E-Link Eagle
4.3.1 Connect the PC to any Ethernet port on the radio as shown in Figure 1
below

110-240VAC

PoE injector

Cat 5e Ethernet
cables

Figure 2: E-Link Eagle Power and Data Connection

4.3.2 Open a browser on the PC and enter the default address of the radio in
the location bar. The default address for a Low Band Radio is
10.100.7.247, and for a High Band Radio it’s 10.100.7.248. Then press
“enter”, and the screen below will appear.

14 of 56
Figure 3: E-Link User ID/Password Screen

4.3.3 Enter the username “admin”. There is no password required. Just hit
“enter”, and the following screen will open.

15 of 56
1

6
Figure 4: Opening Screen Details

1 Banner – This area Contains basic information about the radio and the
link. The first panel contains the serial number, Common Language
Location Indicator, and the Controller version. The second panel
contains the Receive Signal Level, the Bit Error Rate, and the Test
Indication. The third panel contains the Channel Bandwidth, and the
Channel Frequency.

2 Navigation Panel – This is the area where the various programmable


parameters can be selected. The parameters are divided into two main
categories, Radio and Switch. To view the parameters for each
category, click on the word, not the arrow next to it.

3 Port State Overview – This item will appear when you first log into the
radio, and can also be accessed at any time by clicking on
Switch>Monitor>Port State. All other features in this section will appear
on every page.

16 of 56
4.3.4 Hover the mouse cursor over a port reveals its current state, and
clicking on a port will open another screen showing detailed port
statistics.

4 Log Out Button – Clicking on this will log you out of the radio and open
the login page.

5 Help Button – Clicking on this will open up a help window with help
categories for the page from which it is opened.

6 Refresh Button –Clinking on this button on this will refresh the current
page. Clicking on the Auto refresh box causes the current page to be
automatically refreshed at approximately one second intervals. Clicking
on it again stops Auto-refresh.

4.4 Radio Setup


4.4.1 Click on Radio Functions>Setup in the Navigation Panel. The following
screen appears.

Figure 4: Radio Setup Page

17 of 56
4.4.2 This page contains the panel where radio configuration changes can be
made, as well as another panel showing the current status of the link.

Please be aware that any changes that are entered are only made to
the radio, to which you are currently connected, and any changes
made to Frequency, Bandwidth, Mute, CW, or Data Rate will take down
an operating link until the same changes are made at the other end of
the link.

4.4.3 Channel Bandwidth: Drop down allow the user to select the
operating channel bandwidth, if licensed, from the pull down menu.

4.4.4 Channel Frequency: Input the Transmit Frequency in MHz for which
this radio is assigned. Valid frequencies must be divisibly by 125MHz.

4.4.5 ATPC or Alignment: Select “ATPC” or “Alignment” from the next pull
down menu. “Alignment” should only be selected for use during the
alignment procedure as it will fix the transmit power per the value set
in the Alignment TX Power box. The radio must be set to ATPC after
the link is properly aligned.

4.4.6 Min TX Power and Max TX Power: Enter the Minimum and
Maximum Transmit ATPC power levels. Allowable range is from -5 dBm
to +22 dBm. This feature only works with ATPC is selected.

4.4.7 Mute: Enable Transmitter Mute for a specific period of time which is
selected on the Configuration Page.

4.4.8 CW: Disables transmitter modulation and sends a constant carrier out
the antenna port for tests requiring an unmodulated signal.

4.4.9 Minimum and Maximum Bit Rate: Selects the allowable minimum
and maximum bit rates from the pull down menus. This must be done
in order for Adaptive Coding and Modulation to operate. The maximum
bit rate is controlled by the license key installed on the Licensing page.

4.5 Setting the Radio’s IP Address


4.5.1 Radio IP Address can be changed my selecting the link from the
Navigation pane:

Switch>Configuration>System>IP in the Navigation Panel.

This will open the following screen.

18 of 56
Figure 5: IP Configuration Page

4.5.2 Located on this page, there are two columns; the first titled
“Configured” is where the new configuration will be entered. The
second, titled Current” is the present configuration, and will be updated
when the new entries are completed and the “Save” button is clicked.

4.5.3 Step 1 – If the radio is to be a DHCP client, and get its address from a
DHCP server on the network, click on the box next to “DHCP Client”.

4.5.4 Step 2 – If the radio is not to be a DHCP Client, enter the desired IP
address in the IP Address section.

4.5.5 Step 3 – Enter the desired subnet mask in the “IP Mask Section.

4.5.6 Step 4 –IP Router: Required if radio is managed outside of the subnet

4.5.7 Step 5 – If applicable, enter the VLAN ID number, in the “VLAN ID


section. Refer to Section 5 prior to entering the VLAN ID number for

19 of 56
additional information prior to setting this value otherwise it is possible
to loose management access.

4.5.8 Step 6 – If the radio is to be connected to a particular DNS server,


enter its address in the “DNS Server” section.

4.5.9 Step 7 – If the additional security of DNS Proxy is desired, click on the
box next to “DNS Proxy”

4.5.10Step 8 – After all entries have been made, click the “Save” button.
After a few seconds, the “Current” column will display the new entries,
and the IP configuration is complete.

4.6 Detailed Status Page

4.6.1 Select from the navigation pane Radio Functions>Detailed Status in


opens the following screen.

Figure 6: Detailed Status Page

20 of 56
4.6.2 This is an information only page, and no data can be entered here. The
page contains a refresh button that refreshes the page, or Auto-refresh
can be selected which refreshes the page at one second intervals.

4.6.3 The System Quality Panel displays the current TX and RX data rates as
well as the current Bit Error Rate and Receive Signal Level. If the link
is not yet aligned, or the far end transmitter is disabled, the RSL will
read below -70 dBm. Also displayed are the Local Unit Uptime, the
current Tx and Rx status and temperatures of the RF Transmitter,
baseband board and internal power supply board.

4.6.4 The IF Modem section displays information as to whether the


transmitter is muted, Data or CW has been selected, and the Local
Oscillator is locked. If the Local Oscillator is Unlocked indicates an
transmitter failure and the ODU will require replacement

4.6.5 The RF Transceiver Status displays the current Tx power level, the Tx
Monitor voltage, the setting of the Tx Attenuator, (Enabled or
Disabled), and the Tx channel setting. The Tx Monitor voltage range is
between 0v and 1v. This value changes the Tx Output power. 0v
indicates a possible failure in the transmitter.

4.6.6 The Power Supply panel displays the various specified internal
operating voltages in bold print and the actual voltage in normal print.

21 of 56
4.7 Configuration Page
4.7.1 Selecting from the navigation pane

Radio Functions>Configuration opens the following screen.

Figure 7: Configuration Page

22 of 56
4.7.2 This page is used for configuration of the Receive Signal Level and Bit
Error Rate Measurement alarm thresholds, and the Tx Mute Auto
Timeout function.

4.7.3 RSL Alarm Threshold Red: RSL value in this box causes RSSI
indicator to change from Green to Red. This level is entered manually
and saved by clicking on the Save button.

4.7.4 RSL Alarm Threshold Green: RSL level at which, as the signal level
increases, the radio will display change a Red indication to Green. This
level is entered manually, and saved by clicking on the Save button.

4.7.5 BERM Alarm Threshold: Bit Error Rate value at which the radio
BERM alarm, both through the User Interface and SNMP. This value is
set using the pull down menu. This feature only changed when the
Save button is clicked.

4.7.6 TX Mute Auto Timeout: Sets the time interval which the Tx Mute or
CW feature will automatically be disabled. This feature must be first
enabled using the pull down menu and then entering the time in
minutes manually. The maximum that can be set is 120 minutes. This
feature will not be set until the Save button is clicked.

4.7.7 Reset Button will reset all values to their previous settings.

4.7.8 The hyperlinks below Save and Reset buttons are providing quick
access to the “System Information Configuration” and “SNMP”
configuration pages.

4.7.8.1 Clicking on “System Information Configuration” on the Configuration


Page will open the following screen.

23 of 56
Figure 8: System Information Configuration Page

4.7.9 This page is where System Contact, System Name, and System
Location are entered. These entries are optional and for information
only and do not affect the operation of the radio. Enter the information
as appropriate to the local network, and click on the Save Button.

24 of 56
4.7.9.1 Clicking on “SNMP” on the Configuration page will open the following
screen.

Figure 9: SNMP Page

4.7.9.2 This page is where all of the SNMP information as it applies to the
local network is entered.

4.7.9.3 Under SNMP System Configuration, the following items can be


configured.
 Mode – This is a pull down menu and the options are Enabled or Disabled. This applies to
the entire SNMP feature.
 Version – This is a pull down menu and the options are V1, V2c, and V3. Select the one
that is compatible with the SNMP Management program on the local network.
 Read Community – Manually entered, Typically Public
 Write Community – Manually entered, typically Private
 Engine ID -

25 of 56
4.7.9.4 Under SNMP Trap Configuration, the following items can be
configured.
 Trap Mode – This is a pull down menu that will Enable or Disable Trap Mode
 Trap Version – This is a pull down menu and the options are V1, V2c, and V3. Select the
one that is compatible with the SNMP Management program on the local network.
 Trap Community – The name of the trap community is manually entered here, typically
Public
 Trap Destination Address – If the desired trap destination address is an IPV4 address,
enter it here.
 Trap Destination IPV6 Address - If the desired trap destination address is an IPV4 address,
enter it here.
 Trap Authentication Failure – This is a pull down menu that enables or disables this
feature.
 Trap Link-up and Link-down - – This is a pull down menu that enables or disables this
feature.
 Trap inform mode
 Trap Inform Timeout (seconds)
 Trap Inform Retry Times

4.7.9.5 The Save button at the bottom of the page must be clicked to activate
the selections. The Reset button returns all items to their previous
settings.

26 of 56
4.8 Installation Page
4.8.1 Clicking on Radio>Installation in the navigation Panel will open the
following screen.

Figure 10: Installation Page

4.8.2 This page is for information only and does not affect the operation of
the radio. There is a column for information on the local radio, and a
second column for the same type information on the remote radio.
Both columns require the information to be manually inputted.

4.8.3 The information to be entered here is as follows:

 CLLI – Common Language Location Indicator


 Local City – City where radio is installed
 Latitude of site where radio is located
 Longitude of site where radio is located
 Asset tag of radio if one is assigned
 Customer assigned serial number if required

27 of 56
4.9 Diagnostics Page
4.9.1 Clicking on Radio>Diagnostics in the Navigation Panel will open the
following screen.

Figure 11: Diagnostics Page

4.9.2 The purpose of this page is to restart the radio as may be required for
fault recovery. Select Local ODU from the pull down menu to restart
the RF portion of the radio, or Local Modem to restart the modem
portion of the radio.

28 of 56
4.10 Security Page
4.10.1Clicking on Radio>Security>Licensing in the Navigation Panel will open
the following screen.

Figure 12: Security-Licensing Page

4.10.2 This page is where Rate Licensing codes are entered. If the link is
purchased with less than the maximum capacity, a license for
additional capacity can be purchased from your E-Band
Communications Sales representative. Licenses are available for the
following throughputs:

License License Description


EAG-SUP-83-333 QPSK, 83 Mbps to 333Mbps
EAG-SUP-333-500 Adaptive Modulation and Rate License adding 8PSK to
basic license, 333 Mbps to 500Mbps
EAG-SUP-500-1000 Adaptive Modulation & Rate License from 16QAM - 64QAM,
500 Mbps to 1000Mbps
EAG-SUP-1000-2000 Adaptive Modulation and Rate License from 1000 Mbps to
2000Mbps
EAG-SUP-2000-3000 Adaptive Modulation and Rate from 2000 Mbps to

29 of 56
3000Mbps

Table 2: Available Eagle Adaptive Rate Licenses

4.10.3To increase the capacity after purchasing a new license, enter the key
supplied with the license in the first blank row in the Key column, and
click on Submit. The new maximum throughput rate will be displayed in
the Info column.

4.11 Factory Page


4.11.1This page is for factory use only. Technical Bulletins will be issued with
specific instructions for applicable features on this page. It is
recommended not to change any values listed on this page.

30 of 56
4.12 Logs Page
4.12.1Access to the internal performance and event logs may be accessed by
selecting Radio>Logs located in the Navigation Panel. The following
page opens.

Figure 13: Log Link Page

4.12.2Clicking on the System Log Information hyper opens the following


screen.

31 of 56
Figure 14: Log Page

4.12.3 This page displays the event and performance history log. Under
System Log Information there are two pull down menus. The first,
labeled “Level”, allows selection of the level or levels of logs to be
displayed. The choices are Info, Warning, Error, and All, in order of
severity. Once selected, the alarms will be displayed automatically

4.12.4The Clear Level pull down menu displays the same options as the Level
menu, but once the level is selected, the Clear button in the upper right
hand corner must be clicked before the alarms will be cleared.

4.12.5At the top of the alarm display, the number of alarm entries per page
and the start ID number on the present page can be selected. These
choices must be entered manually, and the Refresh button in the upper
right hand corner of the page must be clicked.

4.12.6In the upper right hand corner of the page, next to the Refresh and
clear buttons, there are four buttons for navigation through the display.
They operate as follows.
 |<< Back to the first item displayed.
 << Back one page
 >> Forward one page

32 of 56
 >>| Forward to last item

5 Eagle - VLAN Management Configuration


5.1 Configuration Steps
5.1.1 Configuration of the Eagle’s management port can be achieved via the
use of a web browser session:
MS Internet Explorer
Google Chrome
Mozilla Firefox

Follow these steps to properly configure the management interface to


be access via a secure Virtual LAN or VLAN

Caution – Not following these steps exactly can cause loss of


communication with the radio which can only be recovered at the
factory.

5.1.2 The following example is based on Factory default IP addresses and the
PC used must be capable of VLAN tag functionality to complete the
configuration.

5.1.3 Access the Eagle radio using a web browser either using HTTP or HTTPs
session. The PC has to be configured to match the radio’s IP address
and subnet: 10.100.7.xxx, 255.255.255.0. (Do not use 10.100.7.247
or .248 as these addresses are used by the radio.)

Figure 5: Accessing Radio Management Using HTTP Session

5.1.4 A login prompt will be displayed by the browser.

33 of 56
Enter username: admin

Default password: [blank], No


password

Click to Log in.

5.1.5 To access the unit, use the admin user, default credentials.
User Name: admin
Password:
(Note, there is no password)

5.1.6 Once inside, the Port State Overview page is displayed.

Figure 6: Opening Screen after Login

5.1.7 Configure VLAN Membership by navigating to Switch>VLANs>VLAN


Membership.

34 of 56
Select VLAN Membership

5.1.7.1 Configure the VLAN ID.

Select Add New VLAN button. Under VLAN ID insert ID number.


In this example 10 is used and under VLAN Name provide a
name for the VLAN. In this example Mgmt is used.

In this example, ports 1 and 4 are added for local access. Port 8
is also added for remote or access from the wireless. Selection
is accomplished by clicking on each of the boxes under Port
Members.

Complete configuration by click on the “Save” button

Do Not remove Port 1 from VLAN ID 1 membership. This will result in


losing communication with the radio’s management interface.

35 of 56
5.1.7.2 Configure VLAN Port type. Navigate to Switch>VLANs>Ports. The
VLAN Port Configuration is displayed.

Figure 7: VLAN Port Configuration

5.1.7.3 Configure Ports 1 and 4 as C-Port (VLAN aware).

5.1.7.4 Configure Port 8 to S-port. This port will work like a tunnel and allow
VLAN tag traffic as well as non-VLAN tag traffic to pass through the
wireless link.

5.1.7.5 Click the “Save” button to complete configuration.

Figure 8: VLAN ID 10 Port Setting Example

36 of 56
5.1.7.6 Configure the radio’s management port with VLAN ID 10. Navigate to
Switch>Configurations>System>IP. The IP Configuration is
displayed.

Figure 9: IP Configuration Settings

5.1.7.7 Access to the radio will be lost as the PC will not be on the same VLAN
as the radio. Verifying the VLAN ID change is operational a PC with a
network card capable of tagging frames with VLAN ID 10 is required.
Or a managed Ethernet switch capable of add VLAN tags to the traffic.
Once, the PC has been configured with the correct VLAN ID and/or
connected to the managed switch’s tagged port, just type in the new
IP address on the URL bar of the browser. Either the login prompt will
display or the “Port State Overview” page will display, confirming that
the changes were successful.

Figure 10: Port State Overview Page

37 of 56
5.1.7.8 Continue with the following setup procedure if Port 1 is only used for
management or access to VLAN ID 10.
Navigate to Switch>VLANs>VLAN Membership. The VLAN
Membership Configuration page opens:

Port 1 and 4 are removed from VLAN 1 membership

Figure 11: VLAN Port Membership Example

This step cannot be performed at the beginning of this procedure.


Once Port 1 is removed from VLAN ID 1 Membership, access to the
Eagle’s management port is lost. Therefore, this step is performed
after the management port of the Eagle is reconfigured to the new
VLAN ID and access to the management port is restored.

5.1.8 Repeat this process for all radios in the network using this VLAN ID or
tag.

6 QoS
This section describes how to set up Quality of Service parameters. Setting
QoS is important when using the E-Link Eagle’s ARM feature. Properly setting
QoS will keep vital services connected when the radios throughput is reduced
due weather events along the path. The following setup examples can be
used or any of the user accessible ports not just the port listed in the
example.

38 of 56
6.1 Configuring QoS no VLAN
6.1.1 Configured a QoS control list. Navigate to
Select the “+” to add a configuration
Switch>Configuration>QoS>QoS Control List

Figure 12: QoS Control List Configuration

6.1.2 Create a Control Entry or a QCE. Once the QCE page displays,
configured port 4 to screen traffic base on Priority 7

Figure 12: QCE page for PCP 7. Select save before proceeding
Once the QCE is save, add a new entry by selecting the “+” again
Figure 14: QCE list with priority 7 configured

Figure 13: QoS Control List Configuration


39 of 56
6.1.3 Create a QCE for PCP 4.

Figure 14: Create QCE Configuration

6.1.4 Once both entries have been configured, the list will displayed the
entries

Figure 15: QoS Control List Configuration

40 of 56
6.2 Configured QoS with VLAN tag only
6.2.1 Configured VLAN ID 1000

Figure 16: Select VLAN Membership

6.2.2 Add a new VLAN ID, entered a name and select ports as members.
Ports 4 and 8 are added to new VLAN ID 1000 (QoSPort)

Figure 16: VLAN Membership

41 of 56
6.2.3 Configure the ports to VLAN aware. Navigate to Switch>
Configuration>VLANs>Ports. Port 4 is configured to Aware and filter
tagged only traffic. Port 8 to Aware and allow all traffic

Figure 17: Ports Configured to Aware and Tagged Only Traffic

Configured a QCE for filtering on Port 4, for VLAN ID 1000 and PCP or Priority
4

42 of 56
Figure 18: QoS Control List, Class Setting

6.2.4 Once all the priorities or PCP have been configured, the QoS Control
can be edited by selecting the “e” on each QCE#.

Figure 19: QoS Sample Control List

43 of 56
6.2.5 Adding a Port Scheduler for further control by navigating to
Switch>Configuration>QoS>Port Scheduler

Figure 20: Port Scheduler

6.2.6 Configure Port 4 with “Weighted” mode and 5% for Q0, 80% for Q1,
1% for Q2, 1% for Q3, 15% for Q4 and 1% for Q5. Note, weighting
values for each Q used must add up to 100% for the port.

44 of 56
Figure 21: QoS Egress Port Scheduler

Once the Scheduler for Port 4 is configured, the page updates and
displays the new configuration:

Figure 22: QoS Egress Port Schedulers

45 of 56
6.3 Configuring Quality of Service using DSCP
6.3.1 Configuring QoS Control List with DSCP. In this example, Port 4 is
configured to screen for VLAN ID 1000 tag only traffic, with a frame
type IPv4 with DSCP specific of class 3 or 24 and placed under Class 3
or Queue 3 priority.

Figure 22: QCE with DSCP Screening

VLAN ID 1000 and port 4 must be configured before creating a


QCE for this ID and port. See section 6.2.2 and 6.2.3 for
information on how to properly configure VLANs.

46 of 56
6.3.2 Configure QoS with Priority change based on DSCP. In this example,
Port 4 will be configured to screen for VLAN ID 1000 tag only traffic, of
frame type IPv4 with DSCP specific to class 3 or 24 and it will be
redirected to higher priority queue of 5.

Figure 23: QCE with Queue Redirection

If your system will be handling other untagged traffic thru other ports,
it is recommended that Port 8 (or the wireless ports) should be added
to each QCE for better results.

47 of 56
6.3.3 QCE configured with a 250MHz RF Channel bandwidth connection.

Figure 24: QCE with Port 8 (250MHz Channel Bandwidth)

48 of 56
7 Software Update Procedures
7.1 Tools and Methods
7.1.1 Tools and equipment needed for software update
PC or laptop with a web browser, with telnet enabled
Ethernet cable to connect to the radio
UI Software Update Package

7.1.2 UI Update Methods


Two methods are available for updating the E-Link Eagle UI software:
1. Web GUI
2. Command Line

7.1.3 The UI software package is provided in two formats, a binary image


and a compressed image. The binary image is used when updating
through the Web UI. The compressed image is used when updating
through the Command Link Interface (CLI). Both images are provided
in the release package. Which method used for updating is left up to
the user.
The Web GUI update procedure immediately reboots the software when
the installation in complete and makes this the operating image.

The CLI update procedure loads the new UI into the standby memory
slot and the user determines when to activate the new UI.

7.2 Update Using Web GUI


7.2.1 Updating through the Web Interface
Updating the UI through the Web Interface requires an Ethernet
connection between the host PC and the E-Link Eagle requiring
an update. The UI software update package use the file
extension of “.dat”.

7.2.2 Procedure

7.2.2.1 An IP connection between the host PC and the target E-Link Eagle
radio. It is recommended but not necessary the host PC’s IP address
reside in the same IP subnet as the target radio for updating.

49 of 56
The factory default IP addresses for the E-Link Eagle are:
Low Band: 10.100.7.247
High Band: 10.100.7.248
If the IP address of the target radio was previously changed, use
that address along with user ID and password where required.

7.2.2.2 Copy the new UI software package file to a known location on the host
PC. For example, copy the file to the PC’s desktop where the

7.2.2.3 Open a web browser on the host PC. Enter the IP address of the target
radio in the address bar of the browser.

7.2.2.4 A pop up dialog box will open after the connection requesting the user
name and password.
User Name: admin
Password: <none>

50 of 56
7.2.2.5 The UI web page will open.

7.2.2.6 On the left side of the web page, navigate to


Switch>Maintenance>Software>Upload.

7.2.2.7 A screen will open next to the navigation bar, labeled File Upload.

7.2.2.8 Click on the Browse button. A new dialog box will open labeled File
Upload. Navigate to the directory or folder containing the new UI
software package. Note, file name extension is “.dat” Click on the
package. The file name will appear in the File name box at the
bottom of the dialog box. Click on Open.

Figure 25: PC File Upload Selection Screen

7.2.2.9 The file name will appear next to the Browse button. Click on the
Upload button.
Several dialog boxes will open during the upload and memory flash
operation. The upload and memory processing will take 3 to 5
minutes. After the update process is complete, the radio will reboot
with the new UI operating the radio. Do not power cycle the radio
during this process.

51 of 56
Figure 26: Firmware/Modem Update Progress Indication

7.3 Update Using Command Line Interface


7.3.1 This method requires a Telnet connection from the host PC to the radio.
In addition, a TFTP server is required to host the new UI package.

7.3.1.1 Copy the Eagle UI upgrade file to a known location on the host PC.
The upgrade file extension ends with “.gz”

7.3.1.2 Start a TFTP server (NBTFTP.exe) on the host PC.

7.3.1.3 Set the search directory of the TFTP server to the directory where the
upgrade software is located.

7.3.1.4 Open a Command window on the host PC.

7.3.2 Telnet to the target E-Link Eagle radio by typing at the system prompt:
C:\>telnet <ip_addr>

7.3.3 Connection should establish and the radio will respond with a request
for the Username. Enter “admin”. A request for password will follow.
The default password is <enter> or return on the PC keyboard.

7.3.4 The Eagle will send a message with the number of error entries in the
syslog and then display a prompt.

52 of 56
Periodic Status
Message

Figure 27: CLI Periodic Status Message

7.3.4.1 In addition, the Eagle sends a periodic status message when


connected. This message is sent every minute. A sample message is
shown above. This message display can be disabled using the
following CLI commands. Disabling the periodic message reduces the
possibility of mistyping.

>debug trace module level eband_radi default none


>debug trace module level eband_fpga default none

7.3.4.2 The syntax for uploading the UI image uses the follow CLI command.
>debug firmware managed.bk <ip_addr of TFTP server> <file name:
Eaglexxx.gz>

For example:

>debug firmware load managed.bk 10.100.7.3 Eagle0004.gz

The command tells the radio software to load into the backup image memory
location the UI image available from the TFTP server located at 10.100.7.3
with the file name of Eagle0004.exe.

7.3.4.3 The radio will return the following message when the command is
executed:
Download “<filename>”, x,xxx,xxx bytes
Erasing image...
Programming image...
Programmed xxxxxxx bytes (checksum 0xxxxxx) to managed.bk – OK

53 of 56
The time for this process is 3-5 minutes to complete.

7.3.4.4 After the software image upload is completed. Use a web browser
and log into the target radio using the IP address of the radio in the
URL bar. Navigate to Maintenance>Software>Image select and click
on Activate Alternate Image select. This command actives the
alternate image and places the active image in standby.

7.4 Update FPGA/Modem Firmware


7.4.1 Upgrading FPGA/CPU modem firmware uses requires the following:
 PC with Telnet services
 TFTP server on a PC that the Eagle radio has access
 FPGA/CPU modem firmware package

7.4.1.1 Start the TFTP server on a PC that the Eagle radio has access.

7.4.1.2 Copy new FPGA/CPU modem code to the TFTP server directory.

7.4.1.3 Start up a telnet session to the target Eagle radio.


>telnet [ip_addr]
Enter user name, (admin), and password, (enter or return), at the
prompts

7.4.1.4 Determine which of the three available memory locations will be used
to store the new code. Use the following command sequence to
determine which memory location is operational:
>upgrade cpu page

The Eagle radio will return one of the following string messages for
example:

>Upgrade cmd [x] succeeded with status 0x0

The value after the word status defines the operational firmware
Factory 0x0 = memory factory default
APP 1 0x4 = memory slot 1
APP 2 0x8 = memory slot 2
APP 3 0xc = memory slot 3

Value Description
0 no command
1 load app from DDR to flash

54 of 56
2 reconfigure FPGA
3 status = startup reason
4 load app from flash to DDR
5 status = 1 if running app, 0 if factory
6 status = app start page
7 calculate CRCs of flash apps
8 last entry, number of commands
Table 3: CMD Parameters

7.4.1.5 Upload the new modem firmware using the following command
>upgrade tftp xfer [tftp_server ip_addr] [modem file name] [file
size] [file checksum]

If the command sequence is inputted correctly, the TFTP server will


upload the firmware to the radio.

After uploading the following message will be displayed at the system


prompt is displayed.

TFTP get from [ip_addr] [file name] passed length: [modem file
size] CRC correct [file size in hex]. Sending image..

7.4.1.6 Commit the upload to flash memory type the following command
sequence
>upgrade cpu burn [x]

Where [x] = flash memory slot, x=1, 2, or 3.

Do not attempt to load into the operational memory slot as


determined in 7.4.1.4. If this slot is selected, upload will not commit
to flash memory.

The commit to flash memory will take 1 to 2 minutes. After the


commit is complete the radio will return the following sequence

Upgrade cmd [x] succeeded with status 0x0

cmd [x] is defined in Table 3: CMD Parameters

55 of 56
7.4.1.7 Confirm the new FPGA/CPU modem code is operational by checking
the Radio Modem Status by returning to the top level prompt by
inputting the necessary up command at the prompt and then typing
the CLI command for Status.

>radio modem status

The radio will return a modem status listing. At the end of the listing
look the following string.

SELECTED FPGA REV: [xx]

Where value [xx] is the operating FPGA code revision. Refer to


Release Notes accompanying the release for this value.

7.4.1.8 If necessary the radio can be rebooted using the following CLI
command.
>system reboot

7.4.1.9 End of Procedure.

56 of 56