Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Lancnc-Maz: Supplemental Manual For The

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6
At a glance
Powered by AI
The manual provides instructions for sending and receiving files between the Mazatrol CNC control and the LANCNC data server unit. It describes the steps to transfer programs on different Mazatrol models.

On the Mazatrol, press Menu Select, then the Data IN/OUT soft key, then the Data OUT soft key. Select the program and press Input to send it to the LANCNC unit. On the LANCNC unit, select the CNC to File option and press Start.

On the LANCNC unit, select the File to CNC option and choose the file. On the Mazatrol, press Menu Select, then the Data IN/OUT soft key, then the Data IN soft key. Press Input to receive the program into the Mazatrol.

Supplemental Manual for the

LANCNC-MAZ
FTP LAN network data server for Mazak CNC Controls
T-1, M-1, M Plus, T Plus, M-2, T-2, M32, T32, Fusion

2008-2014 Calmotion LLC, All rights reserved

Calmotion LLC
21720 Marilla St
Chatsworth, CA 91311
www.calmotion.com
Mazatrol T-1 or M-1

Figure 2: Data output options


Figure 1: Mazatrol T-1 Control

Figure 3: DATA IN and DATA OUT soft keys, INPUT hard key
and the display showing END indicating the completion of
DATA IN

Refer to the figures above when following the instructions to send or receive files from
the Mazatrol on a M-1 or T-1 control.

To Send CMT programs out to the LANCNC:

On the LANCNC unit:


1. Choose the CNC to File option on the LANCNC unit
2. Press the key under Start on the LANCNC unit (press DIR to choose a different
file name to save to).
On the Mazatrol:

2
©2008-2014 Calmotion LLC, all rights reserved
3. Press Menu Select on Mazatrol
4. Press soft key Data IN OUT on Mazatrol
5. Press soft key Data OUT on Mazatrol
6. The prompt “DATA OUT (INPUT)?” is displayed
7. Press the 1 key to send programs out to LANCNC
8. Press soft key Data OUT
9. Press the Input button
10. When it shows “END” on screen it is complete
On the LANCNC unit:
11. Select Done on the LANCNC unit

To receive CMT programs into the Mazatrol from LANCNC:

On the LANCNC unit:


1. Choose the File to CNC option on the LANCNC unit
2. Choose the file to be sent to the CNC
3. Press button under Start on the LANCNC unit
On the Mazatrol:
4. Press the key under Start on the LANCNC unit (press DIR to choose a different
file name to save to). Press Menu Select on Mazatrol
5. Press soft key Data IN OUT on Mazatrol
6. Press soft key Data IN on Mazatrol
7. Press the 1 key to receive programs into LANCNC
8. Press the Input button
On the LANCNC unit:
12. Select Done on the LANCNC unit

3
©2008-2014 Calmotion LLC, all rights reserved
Mazatrol T-2, M-2, M Plus or M32

Figure 5: LANCNC on Mazatrol M Plus

Figure 4: Mazatrol M Plus

Figure 6: Save or Load programs on a Mazatrol M Plus Figure 7: Parameters on M Plus control
control

Figure 8: Input button the M Plus


control

4
©2008-2014 Calmotion LLC, all rights reserved
Figure 9: Mazatrol will probably have two DB25
female connectors, the one labeled Cassette must be
used to save and load Mazatrol conversational
Figure 10: M-2 control screen programs. Sometimes the port is label with a picture
of a cassette tape. The other DB25 is used only for
EIA G code programs.

Refer to the figures above when following the instructions to send or receive files from
the Mazatrol on a M-2, T-2, M Plus, T Plus, M32 or T32 control.

To Send programs out to the LANCNC:

On the LANCNC unit:


1. Choose the CNC to File option on the LANCNC unit
2. Press the key under Start on the LANCNC unit
On the Mazatrol:
3. Press DATA I/O button on Mazatrol
4. Press soft key CMT I/O on Mazatrol
5. press SAVE NC->CMT button
6. Select Program File on Mazatrol to show existing programs in memory
7. Press the 1 key then Input key on the Mazatrol
8. Shows 1 on the NC side
9. Press soft key START on the Mazatrol
On the LANCNC unit:
10. Select Done

To receive programs into the Mazatrol from LANCNC:

On the LANCNC unit:


1. Choose the File to CNC option on the LANCNC unit
2. Choose the file to be sent to the CNC
3. Press button under Start on the LANCNC unit
On the Mazatrol:
4. Press DATA I/O button on Mazatrol

5
©2008-2014 Calmotion LLC, all rights reserved
5. Press soft key CMT I/O on Mazatrol
6. Press soft key LOAD NC->CMT on Mazatrol
7. Enter program number(s) that are to be loaded on the CMT side of the screen
8. Press Start on the Mazatrol
9. If completed properly Mazatrol will show the program numbers on the NC side of
the screen as loaded.
On the LANCNC unit:
10. Select Done

For Mazak machines that use the CMT protocol, the parameters should be set to:

Baud Rate: 4800


Data/Parity/Stop: 8, N, 2
Flow Control: CMT16 (for M1 and T1 controls)
CMT Ver 1 (Typically for the older controls, if doesn't verify use Ver 2)
CMT Ver 2 (Typically for the newer controls, if doesn't verify use Ver 1)
End of Block Delay: No delay
End of Block Char: none/binary
Start of Tx: none
End of Tx: none
Start Rx: Automatic

6
©2008-2014 Calmotion LLC, all rights reserved