Moment Connections, Type 2, Weld
Moment Connections, Type 2, Weld
DATA OF BEAM AND COLUMN TO BE CONNECTED: BEAM IPE 330, COLUMN HEA 240
Weldements: E70
Bending Moment (M),(k-m)= 6040.55 Fv (k/cm2)= 1480.00
Is a load comb. with earthquake or wind? (YES=1,NO=0): 0
l weld = 33.55 cm
t weld= 0.56 cm
USE WELD. THICNESS MIN. w,(cm)= 0.70
e)Beam web-head plate weldement (it must support max. tension due to bending in beam web 0.6Fy):
l weld = 61.40 cm
t weld= 0.54 cm
USE WELD. THICNESS MIN. w,(cm)= 0.60
Pbf: compression force in flange. Value shall be multiplied by 4/3 if earthquake or wind loads act
or by 5/3 if includes only live and dead loads.
Pbf (kg)= 30630.55
g)Stiffeners dimensions:
twc>=2,67.M/(Abc*Fy)
Abc=(dc col-tfc)*(db beam-tfb) Abc= 694.33 cm2
2,67.M/(Abc.Fy)= 0.93 cm Reinforce column web
10 533.4 -9954.768 -9954.768 -16508.73
229543.929 229543.929 180187.381
219376.425
OK!
No cumple
OK!
No cumple. Aumentar espesor plancha o numero de pernos
OK!
Stiffener Required
No stiffener required
OK!
Increase stiffener thickness