Hvac 09
Hvac 09
Hvac 09
Technical Report
LATS program for load calculation and VRF system model selection
Not only LG has been taking lead in product sales, but it provides a One-
Innku Hur LG Electronics Vice President
Stop sales operation with its design proposals during the early stage of
construction, installed product quality guarantee and through after service.
As the head of LG Electronics VRF, I would like to say that LG will always
try to listen to our customers and we will be systematically at service when
needed. With our leading technology and our years of experience, we will take
the lead in the commercial air-conditioner business and become your best
partner.
CONTENTS
Special Edition
Introduction of VRF system
On this issue, VRF system will be introduced with an article extracted and
02
summarized from ASHRAE Journal.
07
that can control refrigerant with inverter compressor and control technology.
Technical Report
LATS program for load calculation and VRF system model selection
LATS program and user manual can be updated with ease at any time through
17
online.
Special Edition │ Introduction of VRF system
Variable refrigerant flow On this issue, VRF system will be introduced with an artic
(VRF)systems, which le extracted and summarized from ASHRAE Journal.
were introduced more
than 20 years ago, are What is VRF?
Variable refrigerant flow(VRF) systems, which were introduced in Japan
relatively unknown in more than 20 years ago, have become popular in many countries, yet they
the United states, but are are relatively unknown in the U.S. The technology has gradually expanded
its market presence, reaching European markets in 1987, and steadily
expected to expand its
gaining marketshare throughout the world. In Japan, VRF systems are used
market presence. in approximately 50% of medium sized commercial buildings (up to 6,500
㎡) and one-third of large commercial buildings (more than 6,500㎡).
Heat
Recovery
Unit
Suction Gas
Liquid
Discharge Gas
� Design Flexibility
A single condensing unit can be connected to many indoor units of
varying capacity (e.g., 0.5 to 4 tons [1.75 to 14kW]) and configurations
(e.g., ceiling recessed, wall-mounted, floor console). Current products
enable up to 20 indoor units to be supplied by a single condensing unit.
Modularity also makes it easy to adapt the HVAC system to expansion or
reconfiguration of the space, which may require additional capacity or
different terminal units.
� Comfort
Many zones are possible, each with individual setpoint control,
because VRF systems use variable speed compressors with wide capacity
modulation capabilities. They can maintain precise temperature control,
generally within ±1℉(±0.6℃)
� Application
VRF systems are generally best suited to buildings with diverse,
multiple zones requiring individual control, such as office buildings,
hospitals, or hotels.
� Future Directions
To spread VRF system in the U.S., the following challenges has to be
targeted.
Advanced technology for cooling, heating and simultaneous cooling and heating
VRF is short for Variable Refrigerant Flow and generally, it means system that can control
refrigerant with inverter compressor and control technology. This will give useful information
of products for educational/commercial facilities and high-story buildings.
Indoor Unit
Outdoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Indoor Unit
<Picture 2> New concept VRF system for residential complex buildings
1,300
2.57e+01
2.35e+01
2.14e+01
1.92e+01
1.71e+01
3,500
3,000
1.50e+01
1.28e+01
1.07e+01
8.56e+00
3,500
6.43e+00
4.29e+00
2.15e+00
1.55e-02
10m/s
<Picture 6> Strong wind around building influence when using conventional air-conditioners in high-
story buildings
3000
40℃
2500 45℃
Cooling capacity(W)
50℃
2200 55℃
2000
ure
rat
pe
1500 tem
d
se
en
ond
C
1000
500
0 2 4 6 8 10 12
evaporating temperature(℃)
<Picture 8> Discharge air influence for conventional air-conditioner and outdoor units
Conventional
Electric Consumption (W)
40 6000
5000
High Temperature
4000
38
3000
2000
36 1000
0
0 5000 10000 15000
34
No Wind Up Wind � Down Wind � Load (W)
<Picture 9> Outdoor unit room temperature influence depending on <Picture 10> energy consumption change depending on
‘building wind’ type for conventional air-conditioner and load
outdoor units
Bedroom 1
Living room
Noise measured area ●
Bedroom 2
●
Indoor unit
operation area
● ●
20,000
supplied by using the cooling and heating device. <Picture 1> is graph
10,000
made with date from Daejun’s meteorological date showing calculated
Load[RT]
0
1 2 3 4 5 6 7 8 9 10 11 12
-10,000
amount of load to be handled to keep an optimal indoor condition. VRF
-20,000
System is not operated with maximum load, but usually is operated with -30,000
less than 60% load condition. In Korea, the highest heat load is -40,000
-50,000
concentrated in December and January. Heating has to run smoothly. It
<Picture 1> 2006 year meteorological data of
has to run efficiently during 60% load (low load), and has to run with Daejun
System capacity(%)
Comp
<Picture 4> Capacity variation, constant-speed control type VS. High-efficiency inverter control
Maker LG S T D M H F
100% Outdoor
Unit
Efficiency
Non-inverter
45
Maker LG T D M H F
Discharge Temp.(℃)
40
Outdoor
35 Unit
30
25
Com-
20 presser
-20℃ -15℃ -10℃ -5℃ 7℃
Outdoor Temp.(℃)
Discharge Heating
Discharge Max. COP
Cooling (COP) 5.68
5
4.5
4.0 3.9 3.7
4
Cooling Heat
Cooling 3.14
Recovery
3
Conventional VRF 1
<Picture 1> Comparison between conventional VRF system and simultaneous cooling and heating
All zone Cooling 20% Cooling 40% Cooling 60% Cooling 80% All zone
function VRF system cooling Heating 80% Heating 60% Heating 40% Heating 20% Heating
� Air-conditioner with the highest efficiency in Korea with <Picture 2> Reaching high energy efficiency
30%, and is called a heat recovery VRF. Such heat recovery VRF can
have the highest efficiency when cooling is at 40% and heating is at 60% Fuzzy Control
-Comp, FAN
operation condition. Like in <Picture 3>, energy efficiency was
maximized optimal refrigerant volume and subcooling control through the Fuzzy Combination of a variety of
Inoor units(Max. 16EA)
Fuzzy algorithm. Fuzzy algorithm is stabilizing the cycle’s stability speed
15% fast than the conventional PID and maximizing efficiency through
<Picture 3> Energy maximization through Fuzzy
active control of subcooling degree among indoor units. algorithm
HR Unit
<Picture 5> Simultaneous cooling and heating VRF system design method
World's unique
<Picture 1> LATS Load : Load calculation program <Picture 2> LATS : model selection and drawing
supporting program
<Picture 6> Tree Mode vs CAD Mode <Picture 8> Selection of outdoor/indoor unit and branch pipe in Tree Mode
<Picture 9> Entering pipe length <Picture 10> Auto Piping (automatic selection of pipe diameter and branch pipe)
<Picture 13> LATS - Table of Content and Load Summary <Picture 14> LATS - Product list and Design condition
<Picture 15> LATS - Piping Diagram and Electricity Connection Diagram <Picture 16> LATS - Cost and Estimate
For those willing to use the website, visit www.lgeaircon.com and click on “Membership” on the upper right side. Select the appropriate membership
step that matches you. After registering for membership, acceptance process is completed in 1day, and you can be a member right away.
• Academy News
• Guide and Textbook
Trainers After checking company security number, certificated
• Communication function for trainers
• Sample management (Admin. Function)