Dme-1 Couplings: S B K K B
Dme-1 Couplings: S B K K B
Dme-1 Couplings: S B K K B
Given data
Power P=15KW
=15*1000=15000W
𝝉f =30MPa
𝝉s=𝝉k=𝝉b=75MPa
𝝈𝒄 =150MPa
9550∗𝑃 9550∗15000
Torque,T= = = 119375Nmm (EQN
𝑛 1200
19.3 c)
T=Tmax=119375Nmm
2.Diameter of shaft
𝜋
T= ×𝒅³×Ƞ× 𝝉S eqn 19.2
16
Assume Ƞ =75%=0.75
𝜋
119375= ×𝒅³×0.75× 75
16
119375*16=𝝅 *d3*0.75*75
𝟏𝟏𝟗𝟑𝟕𝟓∗𝟏𝟔
d3 = =10813.87
𝝅∗𝟎.𝟕𝟓∗𝟕𝟓
d =22.11mm
From DDHAB PAGE NO 14.19,TABLE 14.6
Standard diameter of shaft d=25 mm
3.Bolt circle diameter,D1=2d+0.05 in m (Eqn 19.12 a)
=2d+50 in mm
=2*25 +50=100 mm
4.Design of Hub
Diameter of hub= D2=1.5 d+25( eqn 19.13 a)
D2=1.5*25+25=62.5mm
Length of hub= l=1.25d+18.75 = ( eqn 19.14 a)
l=1.25*25+18.75 =50 mm
5.Design of flange
Outside diameter of flange =D=2.5d +75
D=2.5*25 +75=137.5mm
Thickness of flange t=0.5d=0.5*25=12.5mm
Check for flange
𝐷2
Tmax =t×𝝅×D2×𝝉f × EQN 19.6
2
62.5
119375=12.5×𝝅×62.5×𝝉f ×
2
119375*2 =12.5×𝝅×62.5×𝝉f ×62.5
𝟏𝟏𝟗𝟑𝟕𝟓∗𝟐
𝝉 f= =1.55 MPa
12.5∗𝜋∗62.5∗62.5
d1 =3.19mm
Standard pitch Diameter of bolt from table 18.7 d1=3.54mm
Hence selected bolt size is M4
𝝈𝒄=30.4MPa
INDUCED crushing STRESS OF bolt ie 30.4MPa IS LESS THAN
ALLOWABLE crushing stress ie 150MPa
7.Design of Key
Page No 17.6,table 17.3
According standard diameter of shaft d=25,which comes between 65-70mm
dia..
Width of key B =8mm
Height of keyH=7mm
Length of key= more than length of hub=50 =55mm
Check for key
2∗Tmax
Width of key b= eqn 19.50
τk∗l∗d
2∗𝟏𝟏𝟗𝟑𝟕𝟓x
8=
τk∗55∗25
2∗𝟏𝟏𝟗𝟑𝟕𝟓
τk = =21.7MPa
8∗55∗25
4∗Tmax
Height of key h= eqn 19.51
σk∗l∗d
4∗𝟏𝟏𝟗𝟑𝟕𝟓
7=
σk∗55∗25
4∗𝟏𝟏𝟗𝟑𝟕𝟓
σk = =49.6 MPa
7∗55∗25
INDUCED crushing and shear stress of bolt ie 49.6 MPa & 21 MPa are
LESS THAN ALLOWABLE crushing and shear stress ie 150MPa and 75MPa.
Given P=90kw=90*1000=90000w
Speed n=250rpm
𝝉s =40MPa
𝜃= 1°
L=20d
𝝉b=30MPa
Since crushing of bolt is not given in the question. Consider crushing stress
is twice the shear stress of bolt.
𝜎𝑏 =𝝉b× 2 =30× 2 = 60𝑀𝑃𝑎
Here shear (𝝉K )and crushing stress (𝜎𝑘 )of the bolt is not given. Hence
consider bolt and key material is same
𝝉K=30MPa,
𝜎𝑘=60MPa
Assume efficiency Ƞ=75%
1.Torque transmitted by the coupling
9550∗𝑃 9550∗90000
1. Torque,T= = = 3438000Nmm
𝑛 250
(EQN 19.3 c)
2. 2.Diameter of shaft
𝜋
T= ×𝒅³×Ƞ× 𝝉S eqn 19.2
16
Assume Ƞ =75%=0.75
𝜋
3438000= ×𝒅³×0.75× 40
16
3438000*16=𝝅 *d3*0.75*40
𝟑𝟒𝟑𝟖𝟎𝟎𝟎∗𝟏𝟔
d3 = =
𝝅∗𝟎.𝟕𝟓∗𝟒𝟎
𝟑 𝟑𝟒𝟑𝟖𝟎𝟎𝟎∗𝟏𝟔
d =√ =83.5mm
𝝅∗𝟎.𝟕𝟓∗𝟒𝟎
𝟏
𝟓𝟖𝟒×𝑻𝒎𝒂𝒙×𝑳 𝟒
Based on rigidity 𝒅= ( ) page 14.4 eqn 14.17
𝑮𝜽
𝟏
𝟓𝟖𝟒×𝟑𝟒𝟑𝟖𝟎𝟎𝟎×𝟐𝟎𝒅 𝟒
𝒅=( )
𝟖𝟎𝟎𝟎𝟎∗𝟏
𝟓𝟖𝟒×𝟑𝟒𝟑𝟖𝟎𝟎𝟎×𝟐𝟎𝒅
d4 =
𝟖𝟎𝟎𝟎𝟎∗𝟏
𝟓𝟖𝟒×𝟑𝟒𝟑𝟖𝟎𝟎𝟎×𝟐𝟎
d3 =
𝟖𝟎𝟎𝟎𝟎∗𝟏
𝟑 𝟓𝟖𝟒×𝟑𝟒𝟑𝟖𝟎𝟎𝟎×𝟐𝟎
d= √ =79.47 mm
𝟖𝟎𝟎𝟎𝟎∗𝟏
6.Design of bolt
Number of bolt,i=20d+3 d in m=85mm=85/1000=0.085
20*0.085 +3 =4.7 = 6 consider even number for number of bolts
Diameter of Bolts
Torque transmitted through the bolts
πd1² D1
Tmax = i * 𝝉b*
4 2
πd1² 220
𝟑𝟒𝟑𝟖𝟎𝟎𝟎= 6 * 30*
4 2
3𝟒𝟑𝟖𝟎𝟎𝟎 × 𝟒 × 𝟐 = 6× 𝝅 × d1² ×30× 𝟐𝟐𝟎
𝟑𝟒𝟑𝟖𝟎𝟎𝟎×𝟒×𝟐
d12 = 𝟔×𝝅×𝟑𝟎×𝟐𝟐𝟎
d1=√𝟑𝟒𝟑𝟖𝟎𝟎𝟎×𝟒×𝟐
𝟔×𝝅×𝟑𝟎×𝟐𝟐𝟎
=14.868 mm
Induced crushing stress of the bolt ie 8.16 MPa < 60 MPa ..Hence
Design of bolt is safe.
7.Design of Key
Page No 17.6,table 17.3
According standard diameter of shaft d=85,which comes between 75-85mm
dia..
Width of key b =22mm
Height of keyh=14mm
Length of key= more than length of hub(125mm),=130mm
Check for key
2∗Tmax
Width of key b= eqn 19.50
τk∗l∗d
2∗𝟑𝟒𝟑𝟖𝟎𝟎𝟎
22=
τk∗130∗85
2∗𝟑𝟒𝟑𝟖𝟎𝟎𝟎𝟎
τk = = 28.28MPa
22∗130∗85
4∗Tmax
Height of key h= eqn 19.51
σk∗l∗d
2∗𝟑𝟒𝟑𝟖𝟎𝟎𝟎
14=
σk∗130∗85
2∗𝟑𝟒𝟑𝟖𝟎𝟎𝟎
σk = =44.47 MPa
14∗130∗85
Given P=100kw=100*1000=100000w
Speed n=250rpm
𝝉s =4ON/mm2
𝜃= 1°
L=20d
𝝉b=13N/mm2
𝝉f=14 N/mm2
𝝉k= 𝝉b=-40 N/mm2
𝜎k = 𝜎b=80 N/mm2 (crushing stress=bearing stress=compressive stress)
9550∗𝑃 9550∗100000
1. Torque,T= = = 3820000Nmm
𝑛 250
(EQN 19.3 c)
2.Diameter of shaft
𝜋
T= ×𝒅³×Ƞ× 𝝉S eqn 19.2
16
Assume Ƞ =75%=0.75
𝜋
3820000= ×𝒅³×0.75× 40
16
3820000*16=𝝅 *d3*0.75*40
𝟑𝟖𝟐𝟎𝟎𝟎𝟎∗𝟏𝟔
d3 =
𝝅∗𝟎.𝟕𝟓∗𝟒𝟎
𝟑 𝟑𝟖𝟐𝟎𝟎𝟎𝟎∗𝟏𝟔
d =√ =86.56mm
𝝅∗𝟎.𝟕𝟓∗𝟒𝟎
𝟏
𝟓𝟖𝟒×𝑻𝒎𝒂𝒙×𝑳 𝟒
Based on rigidity 𝒅= ( ) page 14.4 eqn 14.17
𝑮𝜽
𝟏
𝟓𝟖𝟒×𝟑𝟖𝟐𝟎𝟎𝟎𝟎×𝟐𝟎𝒅 𝟒
𝒅=( )
𝟖𝟎𝟎𝟎𝟎∗𝟏
𝟓𝟖𝟒×𝟑𝟖𝟐𝟎𝟎𝟎𝟎×𝟐𝟎𝒅
d4 =
𝟖𝟎𝟎𝟎𝟎∗𝟏
𝟓𝟖𝟒×𝟑𝟖𝟐𝟎𝟎𝟎𝟎×𝟐𝟎
d3 =
𝟖𝟎𝟎𝟎𝟎∗𝟏
𝟑 𝟓𝟖𝟒×𝟑𝟖𝟐𝟎𝟎𝟎𝟎×𝟐𝟎
d= √ =82.31 mm
𝟖𝟎𝟎𝟎𝟎∗𝟏
Considering highest value of shaft diameter,d=86.56mm
From DDHAB PAGE NO 14.19,TABLE 14.6
Standard diameter of shaft d=90mm
6.Design of bolt
Number of bolt,i=20d+3 ,d in m=90mm=90/1000=0.09
20*0.09 +3 =4.8 = 6 consider even number for number of bolts
Diameter of Bolts
Torque transmitted through the bolts
πd1² D1
Tmax = i * 𝝉b* eqn 19.4
4 2
πd1² 230
𝟑𝟖𝟐𝟎𝟎𝟎𝟎= 6 * 13*
4 2
3𝟖𝟐𝟎𝟎𝟎𝟎 × 𝟒 × 𝟐 = 6× 𝝅 × d1² ×13× 𝟐𝟑𝟎
𝟑𝟖𝟐𝟎𝟎𝟎𝟎×𝟒×𝟐
d12 = 𝟔×𝝅×𝟏𝟑×𝟐𝟑𝟎
d1=√𝟑𝟖𝟐𝟎𝟎𝟎𝟎×𝟒×𝟐
𝟔×𝝅×𝟏𝟑×𝟐𝟑𝟎
=23.286 mm
Induced crushing stress of the bolt ie 5.34 < 80 MPa ..Hence Design
of bolt is safe.
7.Design of Key
Page No 17.6,table 17.3
According standard diameter of shaft d=90,which comes between 85-95mm
dia..
Width of key b =25mm
Height of keyh=14mm
Length of key= more than length of hub(131.25mm),=135mm
Check for key
2∗Tmax
Width of key b= eqn 19.50
τk∗l∗d
2∗𝟑𝟖𝟐𝟎𝟎𝟎𝟎
25=
τk∗135∗90
2∗𝟑𝟒𝟑𝟖𝟎𝟎𝟎𝟎
τk = = 26.12MPa
25∗135∗90
2Tmax
Height of key h= eqn 19.51
σk∗l∗d
2∗𝟑𝟖𝟐𝟎𝟎𝟎𝟎
14=
σk∗135∗90
2∗𝟑𝟖𝟐𝟎𝟎𝟎𝟎
σk = =44.91MPa
14∗130∗85
Given data
Power P=15KW
=15*1000=15000W
Speed n=900rpm
𝝉f =8MPa
𝝉s=𝝉k=𝝉b=40MPa
𝝈b= 𝝈k =80MPa
Service factor 1.35
9550∗𝑃 9550∗15000
Torque,T= = = 159166.67Nmm (EQN 19.3 c)
𝑛 900
Tmax= T × Service factor=159166.67× 1.35 =214875.0045 Nmm
2.Diameter of shaft
𝜋
T max= ×𝒅³×Ƞ× 𝝉S eqn 19.2
16
Assume Ƞ =75%=0.75
𝜋
214875.0045= ×𝒅³×0.75× 40
16
214875.0045*16=𝝅 *d3*0.75*40
𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓∗𝟏𝟔
d3 =
𝝅∗𝟎.𝟕𝟓∗𝟒𝟎
𝟑 𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓∗𝟏𝟔
d=√
𝝅∗𝟎.𝟕𝟓∗𝟒𝟎
d =33.16
From DDHAB PAGE NO 14.19,TABLE 14.6
Standard diameter of shaft d=35 mm
πd1² 120
𝟐𝟏𝟒𝟖𝟕𝟓. 𝟎𝟎𝟒𝟓 = 4 * 40*
4 2
𝟐𝟏𝟒𝟖𝟕𝟓. 𝟎𝟎𝟒𝟓 × 𝟒 × 𝟐 = 4× 𝝅 × d1² ×40× 𝟏𝟐𝟎
𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓×𝟒×𝟐
d12 = 𝟒×𝝅×𝟒𝟎×𝟏𝟐𝟎
d1=√𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓×𝟒×𝟐
𝟒×𝝅×𝟒𝟎×𝟏𝟐𝟎
=5.34 mm
Induced crushing stress of the bolt ie 9.56 < 80 MPa ..Hence Design
of bolt is safe.
7.Design of Key
Page No 17.6,table 17.3
According standard diameter of shaft d=35,which comes between dia..
Width of key b =10mm
Height of key h=8mm
Length of key= more than length of hub(62.5mm),=65mm
Check for key
2∗Tmax
Width of key b= eqn 19.50
τk∗l∗d
2∗𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓
10=
τk∗65∗35
2∗𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓
τk = = 18.89 MPa
10∗65∗35
2Tmax
Height of key h= eqn 19.51
σk∗l∗d
2∗ 𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓
8=
σk∗65∗35
2∗𝟐𝟏𝟒𝟖𝟕𝟓.𝟎𝟎𝟒𝟓
σk = =23.61MPa
8∗65∗35