4.9-3 Bar Code - Set Position
4.9-3 Bar Code - Set Position
4.9-3 Bar Code - Set Position
9 Bar code
1 Screw
2.2B2951D09.en
Package Distance A
355B 569 1 mm
375S 628 1 mm
400B 546 1 mm
500B 698 1mm
500S 525 1 mm
750B 536 1 mm
750S 612 1 mm
1000B 611 1mm
1000S 641 1 mm
1000Sq 658 1 mm
1000 HiFin 612 1 mm
1055B 612 1 mm
(Cont'd)
(Cont'd)
c) Set the photocells so that the light spots are centred on the photocell
trigger marks on the tube by means of the screws (2). Tighten the screws.
d) Loosen the screws (3) on both photocells and set distance B by moving
the photocells. Tighten the screws.
B B = 9 1 mm
2
2 Screw
3 3 Screw
2.2B2951D09.en
e) Set the potentiometer (4) to 0.
f) Step up the machine to Production and perform a Short stop.
g) Check that the bottom creases are correctly positioned on the packages.
If they are not, adjust by shifting the photocell unit. Make sure that the
photocells are level.
h) Fine set during Production by means of the potentiometer (4).
4 Potentiometer
3 1 LED
2 Selector
3 Setting knob