CWT5011 Commands
CWT5011 Commands
CONTENTS
Setup control server phone .........................................................................................................................6
CS Setup Control server phone ..................................................................................................................6
Basic parameters .........................................................................................................................................7
UB Setup RTU com port0 BPS..................................................................................................................7
UP Setup RTU com port0 Parity ................................................................................................................7
SIGNALA Enable or Disable low signal Alarm ..........................................................................................7
RSILOW Setup the thread hold value of Signal Low Alarm.........................................................................7
CWT5011 COMMANDS
DAS Enable or Disable Daily Report SMS at 10.pm everyday.....................................................................8
V3.2 PRTCS Send proof time request SMS to first valid CS number when power up.............................................8
PRTSP Send proof time request SMS to SP when power up .........................................................................8
SP Setup the SP phone number ..................................................................................................................8
RPLSUC Reply SMS for successfully executed SMS command ..................................................................8
RPLERR Reply SMS for incorrect executed SMS command .......................................................................9
PW Setup RTU login Password .................................................................................................................9
ID Setup RTU Device ID ..........................................................................................................................9
PIN Setup RTU PIN code..........................................................................................................................9
PUK Setup RTU PUK code.......................................................................................................................9
SMSC Setup the SMS message center service number ..............................................................................10
DESC Setup the RTU description information ..........................................................................................10
Alarm parameters ...................................................................................................................................... 11
ARING Enable or Disable Alarm RING call function................................................................................ 11
ASC Enable or Disable Auto Answer Voice call from CS phones ............................................................... 11
AWB Enable or Disable description in Alarm SMS ................................................................................... 11
UARTEVENT Enable or Disable Export events from UART ..................................................................... 11
IOAT Setup alert sms resend times...........................................................................................................12
DRPTID Enable or Disable ID information in daily report SMS ................................................................12
DRPDEF Enable or Disable ARM/DISARM information in daily report SMS ............................................12
DRPBAT Enable or Disable Power Supply information in daily report SMS...............................................12
DRPMEM Enable or Disable description information in daily report SMS .................................................13
DRPRSI Enable or Disable GSM Signal information in daily report SMS ..................................................13
DRPDIN Enable or Disable Alarm Wired Inputs information in daily report SMS .......................................13
DRPTMP Enable or Disable build in temperature information in daily report SMS .....................................13
Input and output parameters ....................................................................................................................14
IOTP Setup all inputs and outputs type.....................................................................................................14
IOIP Disable inputs alarm .......................................................................................................................14
IOIC Enable inputs alarm........................................................................................................................14
DINURG Enable or Disable inputs “24 hours” option .................................................................................15
DINSND Enable or Disable inputs “sound alarm” option ............................................................................15
IOAS Setup alarm sms limit interval........................................................................................................15
IOLS Setup sms resend interval when input is in alarm state......................................................................15
DINDLY Setup timer for ensuring inputs alarm ........................................................................................16
S Setup digital inputs alarm sms content ..................................................................................................16
S Setup digital inputs recover sms content................................................................................................16
I Setup inputs name ................................................................................................................................16
O Setup outputs name .............................................................................................................................17
IOIS Read inputs status...........................................................................................................................17
IOOS Read outputs status .......................................................................................................................17
IOOR Setup remember outputs status.........................................................................................................17
IOHT Setup Persist timespan of siren.........................................................................................................17
Control outputs commands........................................................................................................................18
IOOH Control outputs on........................................................................................................................18
IOOL Control outputs off........................................................................................................................18
CS<n>
ID=<id>
Read ID is used in GPRS CWT_IO protocol
Command
ID=?
PIN=<code>
Read
Command
PIN=?
PUK=<code>
Read
Command
PUK=?
IOIC=?
DINURG Enable or Disable inputs “24 hours” option DINDLY Setup timer for ensuring inputs alarm
Write Parameters Example: Write Parameters Example:
Command <n>: DINURG0,1 Command <n>: DINDLY0,5
0~7 (input index) 0~7 (Inputs index)
<En>: Enable input0 “24 DINDLY<n>,<time> <time>:
DINURG<n>,<En> 0: Disable (default) hours” option 0~65535 (sec)
1: Enable
Read Default is 0
Read
Command
Command
DINDLY<n>?
DINURG=?
DINSND=?
S Setup digital inputs recover sms content
Write Parameters Example:
IOAS Setup alarm sms limit interval
Command <nn>: S08=alarm recover
Write Parameters Example:
08~15 (inputs recover sms index)
Command <n>: IOAS0,2
S<nn>=<string> <string>:
0~7 (Inputs index)
Recover sms
IOAS<n>,<time> <time>:
Read
0~255 (min)
Command
Read Default is 0
Command
S<nn>=?
IOAS<n>?
I Setup inputs name
Write Parameters Example:
IOLS Setup sms resend interval when input is in alarm state
Command <nn>: I02=sensor
Write Parameters Example:
00~07 (inputs name index)
Command <n>: IOLS0,2
I<nn>=<string> <string>:
0~7 (Inputs index)
Name
IOLS<n>,<time> <time>:
Read
0~255 (min)
Command
Read Default is 0
Command
I<nn>=?
IOLS<n>?
AIN<n>H=?
AIN<n>L=?
AIN<n>SC=?
AIN<n>ZE=?
AIN*OS Setup AIN normal range1’s lag value AINON Enable AIN
Write Parameters Example: Write Parameters Example:
Command <n>: AIN0OS=2.00 Command <n>: Enable AIN0
0~3 (AIN index) 0~3 (AIN index) AINON=0
AIN<n>OS=<lag> <lag>: a float value AINON=<n>
Default is 0 Read
Read Command
Command
AINON=?
AIN<n>OS=?
When AIN value goes out of normal rang1, RTU will alarm. AINOFF Disable AIN
Reference But will not return to normal state before AIN return into range Write Parameters Example:
AINH-lag and AINL+lag Command <n>: Disable AIN1
0~3 (AIN index) AINOFF=1
AIN*ST Setup AIN upload step value AINOFF=<n>
Read
Write Parameters Example:
AIN0ST=5.00 Command
Command <n>:
0~3 (AIN index)
AINOFF=?
AIN<n>ST=<val> <lag>: a float value
Default is 0
AINURG Setup AIN Urgency
Read
Write Parameters Example:
Command Command <n>: Enable AIN0 as urgent
0~3 (AIN index) alarm
AIN<n>ST=? AINURG=<n>,<En> <En>:
0: Disable (default) AINURG=0,1
AIN*R Query AIN Normal range 1 1: Enable
Execution Parameters Read
Command <n>: Command
0~3 (AIN index)
AINURG=?
AIN<n>R
AINDRP=?
AINAS=?
AINLS=?
BUZEN Enable or disable buzzer sound alarm TMPH Setup high point of interior temperature normal range
Write Parameters Example: Write Parameters Example:
Command <En>: BUZEN=1 Command <Val>: -127~128 TMPH=30
0: Disable
TMPH=<Val>
BUZEN=<En> 1: Enable (default)
Read
Read The sound alarm include interior buzzer and
Command
Command any output used as Siren or Buzzer
TMPH=?
BUZEN=?
TMPB=?
TMPAS=?
TMPLS Setup timespan of resend alarm sms TMPURG Setup temperature sensor alarm is urgency 24 hours
Write Parameters Example: Write Parameters Example:
Command <min>: TMPLS=2 Command <En>: TMPURG=1
0~255 (min), default is 0 0: Disable
TMPURG=<En> 1: Enable
TMPLS=<min> 0 means disable the function
Read
Read
Command
Command
TMPURG=?
TMPLS=?
TMPIL=?
TMPOFF Disable temperature sensor alarm
Execution
TMPR Query temperature normal range
Command
Execution
Command
TMPOFF
TMPR
BATEN=?
POWDLY=?
POW
Action index:
U<nn>=?
Y<nn>=?
PW=<pad>
Read
Command
PW=?
DAYRP
ARM
DISARM
RST
LOADF