Notes 1. All Dimensions Are in Millimetres. 2. No Dimension Shall Be Scaled Off, Only Written Dimension To Be Followed
Notes 1. All Dimensions Are in Millimetres. 2. No Dimension Shall Be Scaled Off, Only Written Dimension To Be Followed
Notes 1. All Dimensions Are in Millimetres. 2. No Dimension Shall Be Scaled Off, Only Written Dimension To Be Followed
WP3-4805/2010 Dtd.16.10.2020
Discharge :
5. Basic Dimensions:
7. The structure is designed based on IS 456: 2000 and IS 3370 (Part II): 2009
9.
on the assumption that field particulars received from execution team is fully compliant including
underlying
strata.
10. 15cm thick levelling course in cement concrete 1:4:8 shall be provided below the covered flume.
13. Use of standard cement and steel should be in full abeyance as per Circular No. 8/2016/ Fin dated
04/02/2016
15. The design mix should be approved by competent authority and quality check of relevant materials
should be
17. Lap, anchorage, bending , tying and placing in position of reinforcement shall be done as per
relevant IS codes.
18. Expansion joints and construction joints shall be provided at suitable intervals and shall be in
accordance with
19. Form work and its stripping time shall be as per IS 456-2000.
20. The top of the covered flume shall be loaded only after three months of completion of the last
segment.
21. Wherever applicable clauses in IS 456-2000 shall be closely followed unless otherwise specified.
22. Various provisions made in the drawing shall be verified with respect to the present site condition
and the
feasibility of the proposal as a whole shall be verified by Chief Engineer, Projects I, before execution.
23. Any change in the design shall be made only with the concurrence of this office; otherwise this
drawing should
be strictly followed. IDRB will not be responsible for any structural failure due to nonconformity of
drawings,
24. The mix design should be verified and approved by the agreement authority prior to use in this work.
25. Quality control should be followed as per relevant guidelines and the periodic check reports should
be
26. IDRB will not be responsible for any types of failure due to:
a) Non conformance of quality of materials including water quality used for work as per relevant clauses,
IS codes
d) Non abeyance of the drawings including any changes executed at site without IDRB approval on these
drawings issued.
e) Variation with the investigation field data issued from site to IDRB for evolving this design and with
actual prevailing at site which may be visible/ identified during the course of execution.