The document provides an error code table for a DS150 crane. It lists various error codes from E01 to E25, describes the causes of each error, and recommendations for how to eliminate the error. The errors generally relate to exceeding limits in parameters like boom length, pressure, or angle. The causes involve issues like sensor or component failures, and the eliminations describe checking cables/plugs and replacing faulty components.
The document provides an error code table for a DS150 crane. It lists various error codes from E01 to E25, describes the causes of each error, and recommendations for how to eliminate the error. The errors generally relate to exceeding limits in parameters like boom length, pressure, or angle. The causes involve issues like sensor or component failures, and the eliminations describe checking cables/plugs and replacing faulty components.
The document provides an error code table for a DS150 crane. It lists various error codes from E01 to E25, describes the causes of each error, and recommendations for how to eliminate the error. The errors generally relate to exceeding limits in parameters like boom length, pressure, or angle. The causes involve issues like sensor or component failures, and the eliminations describe checking cables/plugs and replacing faulty components.
The document provides an error code table for a DS150 crane. It lists various error codes from E01 to E25, describes the causes of each error, and recommendations for how to eliminate the error. The errors generally relate to exceeding limits in parameters like boom length, pressure, or angle. The causes involve issues like sensor or component failures, and the eliminations describe checking cables/plugs and replacing faulty components.
E01 Fallen below radius • Fallen below the minimum • Luff down the boom to a range or angle radius or gone past the radius or angle specified in range exceeded maximum angle specified the load chart. in the respective load chart due to luffing up the boom too far E02 Radius range • Gone past the maximum • Luff up the boom to a radius exceeded or fallen radius or fallen below the or angle specified in the load below angle range minimum angle specified chart. in the respective load chart due to luffing down the boom too far E03 Non-permitted • The slewing zone with • Slew to permitted area slewing zone (no load is not permitted load area) E04 Operating mode • A non existing operating • Set the correct operating not acknowledged mode has been selected mode for the operating state or non permitted in question slewing zone • The boom is in a non- • Slew the boom to a permitted slewing zone permitted area. E05 Prohibited length • Boom has been extended • Extend/retract boom to the range either too far or not far correct length enough, e.g. if it is prohibited to go beyond a certain maximum boom length or with load curves for jibs where the main boom has to be extended to a certain length • Length sensor adjustment • Retract boom. Check the has changed, e.g. the pre-stress of the cable reel cable slid off the length (cable must be taut). Open sensor reel. the length sensor and carefully turn the length sensor pot counter clockwise until loosened by using a screw driver Error Code Error Cause Elimination • Clutch between length • Replace the complete clutch sensor pot and drive is including drive wheel and defective adjust length sensor pot as described above • Failure of +5V supply of • Check +5 V supply. analog part of analog Exchange main board in board case of voltage failure or breakdown when loaded with 50 ohms approx. • Cable between central • Check cable and plugs, unit and length sensor is replace, if need be. defective or disconnected. • Defective length • Replace length potentiometer potentiometer. E06 Radius range • Maximum radius as • Luff the jib to a radius or exceeded or fallen specified in the load chart angle specified in the load below angle range exceeded or fallen below chart. with luffing jib minimum angle due to operation luffing down the luffing jib too far E07 Faulty • Overload relay or main • Replace main board acknowledgment of board are defective the overload relay on the main board. • Processor board defective The relay should be • Replace processor board. energized, the 2nd contact however is indicated to be off, or the 2nd contact is indicated to be on while the relay should be de- energized. E08 No acknowledge- • Refer to E07 • Refer to E07 ment from the anti- two-block relay Error Code Error Cause Elimination E11 Fallen below lower • Cable between central • Check cable as well as limit value for unit and length sensor is plugs, replace, if need be. measuring channel defective or disconnected. "length main boom" Water inside the plug of the length/angle sensor • Length potentiometer is • Replace length defective potentiometer • Electronic component in • Replace LMI main board or the measuring channel is processor board. defective E12 Fallen below the • Cable between the central • Check cable as well as lower limit value in unit and pressure plugs, replace, if need be. the measuring transducers defective or channel "pressure water inside the plugs piston side"
• Pressure transducer is • Replace pressure transducer
defective. • Electronic component in • Replace LMI main board or the measuring channel is processor board. defective. E13 Fallen below lower • Refer to E12 • Refer to E12 limit value in the measuring channel "pressure rod side" E15 Fallen below lower • Cable between central • Check cable as well as limit value in unit and the length/angle plugs, replace, if need be. measuring channel sensor defective or loose. "angle main boom" Water inside the plug of the length/angle sensor. • Angle potentiometer • Replace angle sensor defective • Electronic component in • Replace LMI main board or the measuring channel processor board. defective. E16 Fallen below lower • Cable between the central • Check cable as well as limit value in unit and the angle sensor plugs, replace, if need be. measuring channel defective or loose. Water "angle 2" inside the plug of the angle sensor. • Angle potentiometer • Replace angle sensor defective • Electronic component in • Replace LMI main board or the measuring channel processor board. defective. Error Code Error Cause Elimination E19 Reference and/or • The supply voltage is • Check the voltages on the supply voltage falsified by one of the LMI main board. Check defective sensors (DAV, LWG) sensors, plugs and cable, replace, if need be. • Electronic component is • Replace LMI main board defective E20 Analog and/or • The analog voltage is • Check the voltages on the supply voltage falsified by one of the LMI main board. Check defective sensors sensors, plugs and cable, replace, if need be. • Electronic component is • Replace LMI main board defective E21 Upper limit value in • Refer to E11 • Refer to E11 measuring channel "main boom length" has been exceeded. E22 Upper limit value in • Refer to E12 • Refer to E12 measuring channel "pressure piston side" has been exceeded E23 Upper limit value in • Refer to E12 • Refer to E12 measuring channel "pressure rod side" has been exceeded. E25 Upper limit value in • Refer to E15 • Refer to E15 measuring channel "main boom angle" has been exceeded. E26 Upper limit value in • Refer to E16 • Refer to E16 measuring channel "angle 2" has been exceeded. E29 Reference and/or • Refer to E19 • Refer to E19 supply voltage defective. E31 Error in the system • The system program • Replace system program E37 program PROM is defective. PROM (PROM No. 0) E38 System program • The system program in • Replace the system program and data EPROM the LMI does not match to PROM or the data EPROM do not match. the programming in the (PROM No. 1) data EPROM Error Code Error Cause Elimination E41 Error in the internal • Computer component • Replace computer write/read memory 80C537 defective component 80C537. (RAM) of the computer • CPU module defective • Replace CPU module. component 80C537 • Processor board • Replace processor board defective. with CPU module. E42 Error in the external • Write/read memory • Replace processor board write/read memory, (CMOS RAM) or with CPU module. 1st part (RAM) processor board defective. E43 Error in the external • Refer to E42 • Refer to E42 write/read memory, 2nd part (RAM) E45 Redundancy error • The A/D converter on the • Replace processor board. in the A/D processing board and the conversion redundant A/D converter in the CPU 80C537 provide different results. E46 Error in the A/D • No acknowledgment of • Replace processor board. converter uPD the A/D converter uPD 7004 of the 7004 processor board. E48 Cyclic RAM test: • Computer component • Replace computer E49 error in the internal 80C537 defective component 80C537. write/read memory (RAM) of the • CPU module defective • Replace CPU module computer component 80C537 • Processor board • Replace processor board defective. with CPU module. E51 Error in the crane • No valid data in the crane • Load crane data EEPROM data EPROM or data EEPROM. containing valid data. EEPROM. • Memory module wrongly • Bridge memory module acc. bridged. to memory type
• Crane data EPROM • Replace crane data EPROM
defective E80 Short circuit in the • Short circuit in the A2B • Replace A2B switch Anti-two Block switch (A2B) switch. • Short circuit in the cable to • Replace cable to the A2B the A2B switch switch Error Code Error Cause Elimination E91 No data trans- • 24 V supply of the console • Check 24 V at terminal X1 of mission form the is interrupted the console electronics console to the central unit • Interruption or accidental • Check the main console ground in the line between electronics - central unit. In console electronics and case of an accidental central unit ground, the transmitter module of the console electronics might be damaged. Therefore, replaces the console electronics. • Transmitter/receiver • Exchange console module is defective electronics or LMI main board E92 Error in the data • Loose connection in the • Check the connection transmission from line between console between console electronics console to central electronics and central and central unit unit unit • Exchange console • Transmitter/receiver electronics or LMI main module is defective board E93 Error in the data • Refer to E92 • Refer to E92 transmission from the central unit to the console E94 No data trans- • Interruption or accidental • Check line to the console (in mission from the ground in the line central case of accidental ground, central unit to the unit - console replace console electronics, console too). • 5 V supply of the • Check connection to the computer in the central power unit unit is missing • 5 V supply is too low • Exchange the LMI main board • Transmitter/receiver • Replace console electronics module is defective or LMI main board • Computer module is • Replace processor board. defective • Electro-magnetic • Eliminate the source of interferences (e.g. when interference by inverse switching contacts or diodes or varistors. valves)
Note: If an error message is displayed which is not contained in above list, please contact PAT America, Inc. service department.