Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ds150 - Error Code Table

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

DS150 - ERROR CODE TABLE

Error Code Error Cause Elimination


E01 Fallen below radius • Fallen below the minimum • Luff down the boom to a
range or angle radius or gone past the radius or angle specified in
range exceeded maximum angle specified the load chart.
in the respective load
chart due to luffing up the
boom too far
E02 Radius range • Gone past the maximum • Luff up the boom to a radius
exceeded or fallen radius or fallen below the or angle specified in the load
below angle range minimum angle specified chart.
in the respective load
chart due to luffing down
the boom too far
E03 Non-permitted • The slewing zone with • Slew to permitted area
slewing zone (no load is not permitted
load area)
E04 Operating mode • A non existing operating • Set the correct operating
not acknowledged mode has been selected mode for the operating state
or non permitted in question
slewing zone
• The boom is in a non- • Slew the boom to a
permitted slewing zone permitted area.
E05 Prohibited length • Boom has been extended • Extend/retract boom to the
range either too far or not far correct length
enough, e.g. if it is
prohibited to go beyond a
certain maximum boom
length or with load curves
for jibs where the main
boom has to be extended
to a certain length
• Length sensor adjustment • Retract boom. Check the
has changed, e.g. the pre-stress of the cable reel
cable slid off the length (cable must be taut). Open
sensor reel. the length sensor and
carefully turn the length
sensor pot counter
clockwise until loosened by
using a screw driver
Error Code Error Cause Elimination
• Clutch between length • Replace the complete clutch
sensor pot and drive is including drive wheel and
defective adjust length sensor pot as
described above
• Failure of +5V supply of • Check +5 V supply.
analog part of analog Exchange main board in
board case of voltage failure or
breakdown when loaded
with 50 ohms approx.
• Cable between central • Check cable and plugs,
unit and length sensor is replace, if need be.
defective or disconnected.
• Defective length • Replace length
potentiometer potentiometer.
E06 Radius range • Maximum radius as • Luff the jib to a radius or
exceeded or fallen specified in the load chart angle specified in the load
below angle range exceeded or fallen below chart.
with luffing jib minimum angle due to
operation luffing down the luffing jib
too far
E07 Faulty • Overload relay or main • Replace main board
acknowledgment of board are defective
the overload relay
on the main board. • Processor board defective
The relay should be • Replace processor board.
energized, the 2nd
contact however is
indicated to be off,
or the 2nd contact
is indicated to be
on while the relay
should be de-
energized.
E08 No acknowledge- • Refer to E07 • Refer to E07
ment from the anti-
two-block relay
Error Code Error Cause Elimination
E11 Fallen below lower • Cable between central • Check cable as well as
limit value for unit and length sensor is plugs, replace, if need be.
measuring channel defective or disconnected.
"length main boom" Water inside the plug of
the length/angle sensor
• Length potentiometer is • Replace length
defective potentiometer
• Electronic component in • Replace LMI main board or
the measuring channel is processor board.
defective
E12 Fallen below the • Cable between the central • Check cable as well as
lower limit value in unit and pressure plugs, replace, if need be.
the measuring transducers defective or
channel "pressure water inside the plugs
piston side"

• Pressure transducer is • Replace pressure transducer


defective.
• Electronic component in • Replace LMI main board or
the measuring channel is processor board.
defective.
E13 Fallen below lower • Refer to E12 • Refer to E12
limit value in the
measuring channel
"pressure rod side"
E15 Fallen below lower • Cable between central • Check cable as well as
limit value in unit and the length/angle plugs, replace, if need be.
measuring channel sensor defective or loose.
"angle main boom" Water inside the plug of
the length/angle sensor.
• Angle potentiometer • Replace angle sensor
defective
• Electronic component in • Replace LMI main board or
the measuring channel processor board.
defective.
E16 Fallen below lower • Cable between the central • Check cable as well as
limit value in unit and the angle sensor plugs, replace, if need be.
measuring channel defective or loose. Water
"angle 2" inside the plug of the
angle sensor.
• Angle potentiometer • Replace angle sensor
defective
• Electronic component in • Replace LMI main board or
the measuring channel processor board.
defective.
Error Code Error Cause Elimination
E19 Reference and/or • The supply voltage is • Check the voltages on the
supply voltage falsified by one of the LMI main board. Check
defective sensors (DAV, LWG) sensors, plugs and cable,
replace, if need be.
• Electronic component is • Replace LMI main board
defective
E20 Analog and/or • The analog voltage is • Check the voltages on the
supply voltage falsified by one of the LMI main board. Check
defective sensors sensors, plugs and cable,
replace, if need be.
• Electronic component is • Replace LMI main board
defective
E21 Upper limit value in • Refer to E11 • Refer to E11
measuring channel
"main boom length"
has been
exceeded.
E22 Upper limit value in • Refer to E12 • Refer to E12
measuring channel
"pressure piston
side" has been
exceeded
E23 Upper limit value in • Refer to E12 • Refer to E12
measuring channel
"pressure rod side"
has been
exceeded.
E25 Upper limit value in • Refer to E15 • Refer to E15
measuring channel
"main boom angle"
has been
exceeded.
E26 Upper limit value in • Refer to E16 • Refer to E16
measuring channel
"angle 2" has been
exceeded.
E29 Reference and/or • Refer to E19 • Refer to E19
supply voltage
defective.
E31 Error in the system • The system program • Replace system program
E37 program PROM is defective. PROM (PROM No. 0)
E38 System program • The system program in • Replace the system program
and data EPROM the LMI does not match to PROM or the data EPROM
do not match. the programming in the (PROM No. 1)
data EPROM
Error Code Error Cause Elimination
E41 Error in the internal • Computer component • Replace computer
write/read memory 80C537 defective component 80C537.
(RAM) of the
computer • CPU module defective • Replace CPU module.
component 80C537
• Processor board • Replace processor board
defective. with CPU module.
E42 Error in the external • Write/read memory • Replace processor board
write/read memory, (CMOS RAM) or with CPU module.
1st part (RAM) processor board
defective.
E43 Error in the external • Refer to E42 • Refer to E42
write/read memory,
2nd part (RAM)
E45 Redundancy error • The A/D converter on the • Replace processor board.
in the A/D processing board and the
conversion redundant A/D converter
in the CPU 80C537
provide different results.
E46 Error in the A/D • No acknowledgment of • Replace processor board.
converter uPD the A/D converter uPD
7004 of the 7004
processor board.
E48 Cyclic RAM test: • Computer component • Replace computer
E49 error in the internal 80C537 defective component 80C537.
write/read memory
(RAM) of the • CPU module defective • Replace CPU module
computer
component 80C537 • Processor board • Replace processor board
defective. with CPU module.
E51 Error in the crane • No valid data in the crane • Load crane data EEPROM
data EPROM or data EEPROM. containing valid data.
EEPROM.
• Memory module wrongly • Bridge memory module acc.
bridged. to memory type

• Crane data EPROM • Replace crane data EPROM


defective
E80 Short circuit in the • Short circuit in the A2B • Replace A2B switch
Anti-two Block switch
(A2B) switch.
• Short circuit in the cable to • Replace cable to the A2B
the A2B switch switch
Error Code Error Cause Elimination
E91 No data trans- • 24 V supply of the console • Check 24 V at terminal X1 of
mission form the is interrupted the console electronics
console to the
central unit
• Interruption or accidental • Check the main console
ground in the line between electronics - central unit. In
console electronics and case of an accidental
central unit ground, the transmitter
module of the console
electronics might be
damaged. Therefore,
replaces the console
electronics.
• Transmitter/receiver • Exchange console
module is defective electronics or LMI main
board
E92 Error in the data • Loose connection in the • Check the connection
transmission from line between console between console electronics
console to central electronics and central and central unit
unit unit • Exchange console
• Transmitter/receiver electronics or LMI main
module is defective board
E93 Error in the data • Refer to E92 • Refer to E92
transmission from
the central unit to
the console
E94 No data trans- • Interruption or accidental • Check line to the console (in
mission from the ground in the line central case of accidental ground,
central unit to the unit - console replace console electronics,
console too).
• 5 V supply of the • Check connection to the
computer in the central power unit
unit is missing
• 5 V supply is too low • Exchange the LMI main
board
• Transmitter/receiver • Replace console electronics
module is defective or LMI main board
• Computer module is • Replace processor board.
defective
• Electro-magnetic • Eliminate the source of
interferences (e.g. when interference by inverse
switching contacts or diodes or varistors.
valves)

Note: If an error message is displayed which is not contained in above list, please contact PAT
America, Inc. service department.