PLD-25/CBS CBS EMERGENCY LED ILLUMINATION SIGN

TECHNICAL CHARACTERISTICS (for LED MODULE specifications see page 3)


Mains voltage 45-250V DC / 80-250V AC/50-60Hz
Maximum power consumption 1.6W / 1.8VA
Light source intensity 100lm
Viewing distance 26m
Degrees of cover protection IP44
Produced in accordance with EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3, EN 1838
Operation temperature range -30 to 50 o C
Relative humidity up to 95%
Construction materials Fire retardant ABS, plexiglas
External dimensions (LxWxH) 280x49x209mm
Typical weight 715gr.
Guarantee 3 years

Thank you for your trust in our products. Olympia Electronics - European manufacturer
GENERAL testing must be done by authorized personnel only.
This luminaire is used indoors (ta 50oC) in places 2. The luminaire must be connected to the mains
where emergency luminaires (CBS) are needed. power supply through a fuse dependent on the total
Each luminaire must be permanently connected to amount of the line’s power load.
mains power supply. INSTALLATION
ΑΤΤΕΝΤΙΟΝ!!! To install the luminaire follow the installation
1. Operations for installation, maintainance or instructions bellow and on pages 2,3.

INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTIONS
1 Dismantle the luminaire by pushing the lock/unlock hooks 1
on each side and pull it down.
2 Installation advice:
Use a flat screwdriver at the indication point in order to
open the luminaire.
3 Pass through the cables from the entry hole and
connect them as shown in the picture. N for neutral L for
live wire and PE for ground (optional).
4 Place upwards the luminaire until the plastic hooks are 2
securely locked and power on the device.
SURFACE MOUNTING ON A WALL (single sided)
Dismantle the luminaire, install the plastic bracket on the
wall (page 2) and perform the respective steps of the
electrical connections. 3
CEILING INSTALLATION L
N
Dismantle the luminaire, install the plastic bracket on the PE

ceiling (page 2) and perform the respective steps of the


electrical connections. 4
HANGING INSTALLATION (Optional)
Install the mounting base (tube) on the ceiling (page 2)
and perform the respective steps of the electrical
connections.
FLAG MOUNTING INSTALLATION (Optional)
Install the flag mounting base on the wall (page 3) and
perform the respective steps of the electrical connections.

Page 1 from 3 922502504_09_003


SUGGESTED MOUNTING METHODS SUSPENDED CEILING INSTALLATION
Suspended ceiling
SURFACE MOUNTING ON A WALL (single side luminaire)

A-2510/PL NOTE!! The installation instructions


(OPTIONAL AFTER REQUEST) are included in the package of the
suspended ceiling base.

FLAG MOUNTED ON A WALL


A-2133 SET
(OPTIONAL AFTER REQUEST)

If necessary place the included


spacers to mount the base.

CEILING MOUNTED

LED MODULE CHARACTERISTICS


PLD-25/CBS
Manufacturer Olympia Electronics S.A.
Model Number 0409153
Voltage Range 11.6-14.4V DC
Nominal Power 780mW
Connections Non reversible connection between main pcb and led module
Temperature (tc) 40 °C max. across the board

NOTE: LED= Light Emitting Diode The light source contained in this luminaire
If necessary place the included LABELING EXPLANATION: shall only be replaced by the manufacturer, or
spacers to mount the base. Z: Central supply his agent, or a similar qualified person.
1: Maintained (*)
HANGING INSTALLATION G: Internally illuminated safety sign NOTE! The light source is non-user replaceable.

WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of
A-2130, A-2131, A-2132 SET warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet,
(OPTIONAL AFTER REQUEST) which accompanies each product. This warranty ceases to exist if the buyer does not follow the
Α technical instructions included in official documents given by Olympia Electronics or if the buyer
modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia
Tube Electronics has fully agreed to them in writing. Products that have been damaged can be returned to
Α-2130 Α=1m the premises of our company for repair or replacement, as long as the warranty period is valid.
GENERAL!! Α-2131 Α=0.5m Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge
Measure the distance of the the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or
mounting holes and after the drilling Α-2132 Α=0.25m not the buyer the transportation cost.
place on these spots the mounting HEAD OFFICE
plugs and fasten the base with the 72nd km. O.N.R. Thessaloniki-Katerini
mounting screws. P.C. 60300 P.O. Box 06 Εginio Pierias Greece