Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

RE2YY

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

INSTRUMENT CABLES

RE2YY (1-50) Pairs


RE2YY (1-50) Pairsxx1.5
1.5mm²
mm²&&
(1-50) Pairs xx2.5
(1-50) Pairs 2.5mm²
mm²300/500
300/500V V
CU / PE / OS / PVC
(Copper Conductor, PE Insulated, Collective Screen, PVC Sheathed)
Standard Specification : BS 5308-1 & IEC 60502

Construction Data
Size Application :
Copper Conductor
Instrumentation cables are suitable for
1.5 mm2 2.5 mm2
No. industrial control system as needed in
of Overall Cable Overall Cable PE Insulation
measurement, control, signalling and
pairs Diameter Weight Diameter Weight
data system technology.
approx. approx. approx. approx.
Tinned Copper -
mm kg/km mm kg/km Drain Wires
1 7.7 89 10.5 157 Special Features on Request
Collective Screen
• Fire Resistance
2 10.4 137 14.0 234
• Oil Resistance
3 12.9 186 16.0 289 PVC Sheath
• UV Resistance
4 14.5 233 18.0 363 • Flame Retardant Cat. A, B, C
5 15.8 298 19.5 464 • Flame Retardant Non Category
6 17.2 340 21.0 520 • Heat Resistance
7 18.4 374 22.5 576 • Anti Termite
9 20.5 462 25.5 725 • Anti Rodent
• Low Smoke Zero Halogen
10 21.5 506 26.5 806
• Nylon Coated
12 24.0 612 29.0 945
14 25.5 699 31.0 1,095
15 26.0 761 32.0 1,192
Note :
16 27.0 803 33.0 1,260
Conductor Shape
18 28.5 870 35.0 1,380 All construction supplied in solid (re) or non compacted circular
19 29.0 913 35.5 1,448 stranded (rm)
20 29.5 974 36.5 1,561
Standard Packing
24 32.5 1,151 40.0 1,829 Size 1.5 mm² :
30 36.0 1,402 44.5 2,250 All conductor supplied in wooden drum @ 1000 m
Size 2.5 mm² :
36 39.5 1,714 48.5 2,692
1 - 36 pairs supplied in wooden drum @ 1000 m
40 41.5 1,882 51.0 2,981 40 - 50 pairs supplied in wooden drum on available length
48 45.0 2,214 56.0 3,561 Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²
50 46.0 2,296 57.0 3,694

Electrical Data
Conductor Insulation
AC
Nominal Mutual
Voltage
Cross Resistance Resistance Capacitance
Test
Section at 20°C at 20°C
max. min. max. -
mm 2
ohm/km G.ohm.km pF/m volt/1 min
1 Pair 2 Pair 2 Pair 3 Pair
1.5 12.1 12.3 5 120 85 1000
2.5 7.41 7.56 5 120 85 1000
1HVos Rev. 2.0 / 2009

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
INSTRUMENT CABLES
RE2YY (2-50) Pairs
RE2YY (2-50) Pairsxx1.5
1.5mm
mm2 2&&
(2-50) Pairs xx2.5
(2-50) Pairs 2.5mm 300/500V V
mm2 2300/500
CU / PE / IS / PVC
(Copper Conductor, PE Insulated, Individual Screen, PVC Sheathed)
Standard Specification : BS 5308-1 & IEC 60502

Construction Data
Size Application : Copper Conductor
Instrumentation cables are suitable for PE Insulation
1.5 mm2 2.5 mm2
No. industrial control system as needed in Tinned Copper -
of Overall Cable Overall Cable Drain Wires
measurement, control, signalling and
pairs Diameter Weight Diameter Weight
data system technology.
approx. approx. approx. approx. Individual Screen

mm kg/km mm kg/km
Tinned Copper -
2 12.6 244 15.4 362 Special Features on Request
Drain Wires
• Fire Resistance
3 13.6 287 16.4 419 Collective Screen
• Oil Resistance
4 14.9 339 17.9 496
• UV Resistance PVC Sheath
5 16.3 345 19.6 506 • Flame Retardant Cat. A, B, C
6 19.1 442 23.0 624 • Flame Retardant Non Category
7 19.1 457 23.0 646 • Heat Resistance
9 23.0 576 27.5 830 • Anti Termite
10 24.5 633 29.5 927 • Anti Rodent
• Low Smoke Zero Halogen
12 27.5 767 32.5 1,092
• Nylon Coated
14 28.5 869 34.0 1,258
15 30.0 946 36.0 1,370
16 31.5 1,008 38.0 1,459
Note :
18 33.5 1,095 40.0 1,606 Conductor Shape
19 33.5 1,141 40.0 1,675 All construction supplied in solid or non compacted circular stranded
20 35.0 1,271 42.5 1,886
Standard Packing
24 41.5 1,492 50.0 2,168 Size 1.5 mm² :
30 44.0 1,792 53.5 2,640 2 - 36 pairs supplied in wooden drum @ 1000 m
36 48.5 2,161 58.0 3,158 40 - 50 pairs supplied in wooden drum on available length
Size 2.5 mm² :
40 50.0 2,366 61.0 3,490 2 - 20 pairs supplied in wooden drum @ 1000 m
48 55.5 2,795 68.0 4,189 24 - 50 pairs supplied in wooden drum on available length
50 57.0 2,900 69.5 4,347 Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²

Electrical Data
Conductor Insulation
AC
Nominal Mutual
Voltage
Cross Resistance Resistance Capacitance
Test
Section at 20°C at 20°C
max. min. max. -
mm 2
ohm/km G.ohm.km pF/m volt/1 min
1.5 12.3 5 120 1000
2.5 7.56 5 120 1000
1HVis Rev. 2.0 / 2009

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

You might also like