Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Nym Sni Iec

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

NYM

NYM 22xx(1.5
(1.5- -35)
35)mm²
mm² 300/500
300/500 V V
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI 04-6629.4 : 2006

Construction Data
APPLICATION :
Nom. Overall Cable
For building wire installed in conduit in dry Copper Conductor
Cross Diameter Weight location and interwiring in switch board and
Section control panel, inherently flame retardant in PVC Insulation
Area approx. approx. compliance with IEC 60332-1.
PVC Innersheath
mm² mm kg/km
Special Features on Request
1.5 9.5 116 • Tinned Coated Copper Conductor PVC Sheath

2.5 10.5 157 • Fire Resistance


• Oil Resistance
4 11.5 203 • Flame Retardant Cat. A, B, C
6 12.5 262 • Heat Resistance
• Nylon Coated
10 16.0 426
16 19.0 638
25 23.0 962
35 26.0 1,270
Note :
Conductor Shaped
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 - 35 sqmm supplied in non compacted circular stranded (rm) conductor shape

Tinned Coated Copper Conductor


Electrical properties for tinned coated copper conductor will be submitted upon request

Standard Packing
1.5 - 4 sqmm supplied in coil @ 100 m or in wooden drum @ 1000/2000 m
6 - 35 sqmm supplied in wooden drum @ 1000 m
Length tolerance per drum ±2%.

Electrical Data
Conductor Insulation Inductance Current-Carrying Short
Nom. DC AC Insulation Capacity circuit current
Cross Resistance Resistance Resistance at 30° C * at
Sect. at 20° C at 70° C at 70° C in air 1 sec
Max. Max. Min. Max. Max.
(mm²) (Ω/km) (Ω/km) (M.Ω.km) (mH/km) (A) (kA)
1.5 12.1 14.478 0.010 0.329 19 0.17
2.5 7.41 8.866 0.009 0.318 25 0.29
4 4.61 5.516 0.0077 0.297 34 0.46
6 3.08 3.685 0.0065 0.281 44 0.69
10 1.83 2.190 0.0065 0.278 61 1.15
16 1.15 1.376 0.0052 0.255 82 1.84
25 0.727 0.870 0.0050 0.252 108 2.88
35 0.524 0.627 0.0044 0.244 134 4.03
12201-02 Rev. 1.0 / 2013

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYM
NYM 33xx(1.5
(1.5- -35)
35)mm²
mm² 300/500
300/500 V V
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI 04-6629.4 : 2006

Construction Data
APPLICATION :
Nom. Overall Cable
For building wire installed in conduit in dry Copper Conductor
Cross Diameter Weight location and interwiring in switch board and
Section control panel, inherently flame retardant in PVC Insulation
Area approx. approx. compliance with IEC 60332-1.
PVC Innersheath
mm² mm kg/km
Special Features on Request
1.5 10.0 136 • Tinned Coated Copper Conductor PVC Sheath

2.5 11.0 186 • Fire Resistance


• Oil Resistance
4 12.0 246 • Flame Retardant Cat. A, B, C
6 13.5 335 • Heat Resistance
• Nylon Coated
10 17.0 527
16 20.5 816
25 24.5 1,229
35 27.5 1,601

Note :
Conductor Shaped
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 - 35 sqmm supplied in non compacted circular stranded (rm) conductor shape

Tinned Coated Copper Conductor


Electrical properties for tinned coated copper conductor will be submitted upon request

Standard Packing
1.5 - 4 sqmm supplied in coil @ 100 m or in wooden drum @ 1000/2000 m
6 - 35 sqmm supplied in wooden drum @ 1000 m
Length tolerance per drum ±2%.

Electrical Data
Conductor Insulation Inductance Current-Carrying Short
Nom. DC AC Insulation Capacity circuit current
Cross Resistance Resistance Resistance at 30° C * at
Sect. at 20° C at 70° C at 70° C in air 1 sec
Max. Max. Min. Max. Max.
(mm²) (Ω/km) (Ω/km) (M.Ω.km) (mH/km) (A) (kA)
1.5 12.1 14.478 0.010 0.329 19 0.17
2.5 7.41 8.866 0.009 0.318 25 0.29
4 4.61 5.516 0.0077 0.297 34 0.46
6 3.08 3.685 0.0065 0.281 44 0.69
10 1.83 2.190 0.0065 0.278 61 1.15
16 1.15 1.376 0.0052 0.255 82 1.84
25 0.727 0.870 0.0050 0.252 108 2.88
35 0.524 0.627 0.0044 0.244 134 4.03
12201-03 Rev. 1.0 / 2013

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYM
NYM 44xx(1.5
(1.5- -35)
35)mm²
mm² 300/500
300/500 V V
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI 04-6629.4 : 2006

Construction Data
APPLICATION :
Nom. Overall Cable
For building wire installed in conduit in dry
Cross Diameter Weight location and interwiring in switch board and
Copper Conductor

Section control panel, inherently flame retardant in PVC Insulation


Area approx. approx. compliance with IEC 60332-1.
PVC Innersheath
mm² mm kg/km
Special Features on Request
1.5 10.5 161 • Tinned Coated Copper Conductor PVC Sheath

2.5 12.0 224 • Fire Resistance


• Oil Resistance
4 13.5 311 • Flame Retardant Cat. A, B, C
6 15.5 424 • Heat Resistance
• Nylon Coated
10 18.5 648
16 22.5 1,027
25 27.5 1,579
35 30.0 2,026

Note :
Conductor Shaped
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 - 35 sqmm supplied in non compacted circular stranded (rm) conductor shape

Tinned Coated Copper Conductor


Electrical properties for tinned coated copper conductor will be submitted upon request

Standard Packing
1.5 - 2.5 sqmm supplied in coil @ 100 m or in wooden drum @ 1000/2000 m
4 - 35 sqmm supplied in wooden drum @ 1000 m
Length tolerance per drum ±2%.

Electrical Data
Conductor Insulation Inductance Current-Carrying Short
Nom. DC AC Insulation Capacity circuit current
Cross Resistance Resistance Resistance at 30° C * at
Sect. at 20° C at 70° C at 70° C in air 1 sec
Max. Max. Min. Max. Max.
(mm²) (Ω/km) (Ω/km) (M.Ω.km) (mH/km) (A) (kA)
1.5 12.1 14.478 0.010 0.329 19 0.17
2.5 7.41 8.866 0.009 0.318 25 0.29
4 4.61 5.516 0.0077 0.297 34 0.46
6 3.08 3.685 0.0065 0.281 44 0.69
10 1.83 2.190 0.0065 0.278 61 1.15
16 1.15 1.376 0.0052 0.255 82 1.84
25 0.727 0.870 0.0050 0.252 108 2.88
35 0.524 0.627 0.0044 0.244 134 4.03
12201-04 Rev. 1.0 / 2013

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYM
NYM 55xx(1.5
(1.5- -35)
35)mm²
mm² 300/500
300/500 V V
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI 04-6629.4 : 2006

Construction Data
APPLICATION :
Nom. Overall Cable PVC Filler
For building wire installed in conduit in dry
Cross Diameter Weight location and interwiring in switch board and
Copper Conductor

Section control panel, inherently flame retardant in PVC Insulation


Area approx. approx. compliance with IEC 60332-1.
PVC Innersheath
mm² mm kg/km
Special Features on Request
1.5 11.5 198 • Tinned Coated Copper Conductor PVC Sheath
2.5 13.0 278 • Fire Resistance
• Oil Resistance
4 15.0 400 • Flame Retardant Cat. A, B, C
6 16.5 524 • Heat Resistance
• Nylon Coated
10 20.0 805
16 25.0 1,274
25 30.0 1,927
35 33.5 2,514

Note :
Conductor Shaped
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 - 35 sqmm supplied in non compacted circular stranded (rm) conductor shape

Tinned Coated Copper Conductor


Electrical properties for tinned coated copper conductor will be submitted upon request

Standard Packing
1.5 - 2.5 sqmm supplied in coil @ 100 m or in wooden drum @ 1000/2000 m
4 - 35 sqmm supplied in wooden drum @ 1000 m
Length tolerance per drum ±2%.

Electrical Data
Conductor Insulation Inductance Current-Carrying Short
Nom. DC AC Insulation Capacity circuit current
Cross Resistance Resistance Resistance at 30° C * at
Sect. at 20° C at 70° C at 70° C in air 1 sec
Max. Max. Min. Max. Max.
(mm²) (Ω/km) (Ω/km) (M.Ω.km) (mH/km) (A) (kA)
1.5 12.1 14.478 0.010 0.329 19 0.17
2.5 7.41 8.866 0.009 0.318 25 0.29
4 4.61 5.516 0.0077 0.297 34 0.46
6 3.08 3.685 0.0065 0.281 44 0.69
10 1.83 2.190 0.0065 0.278 61 1.15
16 1.15 1.376 0.0052 0.255 82 1.84
25 0.727 0.870 0.0050 0.252 108 2.88
35 0.524 0.627 0.0044 0.244 134 4.03
12201-05 Rev. 1.0 / 2013

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

You might also like