HIGH-EFFICIENCY CONDENSING GAS COMBINATION BOILERS

FIRE TUBE COMBI

ENHANCED OPERATING SYSTEM

THREE SIZES:
110,000, 150,000 AND 199,999 BTU/HR

INDUSTRY-LEADING DHW DELIVERY UP TO 4.8 GPM

TRUE INSTANTANEOUS RESPONSE

EASY INSTALLATION AND SERVICEABILITY

USER-FRIENDLY INTERFACE 95%


AFUE Efficiency

heat exch
ar a
ye

ng

/5
ten

er
nt y
f ive

ra

ar r
ye

pa rts w a

FIRE TUBE COMBI

A Game-Changer In Combi Water Heating


Lochinvar has long been the innovation leader in commercial boilers—and now it’s bringing that engineering excellence to residential combi boilers.
Lochinvar’s legendary reliability and performance are now available for apartments and homes, where the combi boiler’s next-generation fire tube
design can provide hot water supply and space heating faster and more efficiently than ever before.

The NOBLE™ combi boiler provides a space-saving choice for builders and specifiers, lowering installation costs by reducing the mechanical equipment
needed to provide rapid, reliable hot water supply and efficient space heating. It also gives plumbing contractors a money-saving alternative for single-
family housing with 1 or 2 bathrooms.

Advanced Electronic Control


The backlit, user-friendly LCD display provides diagnostic
information and system status in real words, not codes. The Set-Up
Wizard display makes it simple to set system parameters in just
minutes, including:
Space Heat Set Point (Coldest Day) Domestic Hot Water Set Point

Maximum Space Heat Set Point Space Heat Rate Limiting

Auto Reset High Limit Outdoor Temperature/Warm


Weather Shutdown

What Makes NOBLE The Best Combi Boiler?


DELIVERS MORE HOT WATER BETTER TECHNICAL SUPPORT AND TRAINING
It’s sized large enough to quickly meet domestic hot water (DHW) Answers are accessible whether online or on-campus. LochinvarU.com
load. Provides DHW from 2.6 (NKC110) to 4.8 gpm (NKC199) at a 77°F is always on, 24/7 for technical support. And Lochinvar University is
temperature rise. the industry’s best-equipped training center.

FASTER DHW RESPONSE TIME 10:1 TURNDOWN RATIO


With many combi boilers when you turn on a hot water faucet, you Operates as low as 10% of the maximum firing rate, preventing on/off
initially get hot water and then a brief burst of cold water before the hot short cycling at the lowest DHW demands or small heating demands.
water resumes. Thanks to its patent-pending control technology, this
combi boiler eliminates this cold water “sandwich.” AIR HANDLER INTERLOCK
Prevents cool air circulation in Hydro-Air installations when the
QUIET OPERATION appliance is making DHW.
Operates so silently that you often have to look at the user-friendly
interface to see if it’s running.
CONSUMER FINANCING AVAILABLE
Check with your local Sales Representative for additional information.
EASIER TO INSTALL AND PROGRAM
With our Set-Up Wizard, you can program the boiler in less than two
minutes. The user-friendly interface uses real words—not confusing
codes—to guide the installer in setting up vital system parameters.
Raising the Bar in Combi Boiler Design
Removing the front panel provides convenient access to
the combustion system, control panel and key components.
This simple-to-install-and-service combi boiler is making an impact on
the industry. 1

The unique fire tube heat exchanger design is what enables NOBLE to 2
produce the results users deserve and have come to expect
from Lochinvar.

1 ADAPTER-FREE FLUE CONNECTION


M
 ulti-material connector allows either PVC,
CPVC, polypropylene or stainless steel
connection directly to the appliance without
adapters. NOBLE also has a built-in combustion
analyzer port. 3

2 DIRECT VENTING UP TO 100 FEET


Offers five venting options for tremendous
installation flexibility. It permits direct-vent air
intake and exhaust runs up to 100 equivalent
feet using either PVC, CPVC, polypropylene or
AL29-4C stainless steel vent pipe.

3 ADVANCED NEGATIVE
REGULATION TECHNOLOGY
Safely and reliably operates with supply
g
 as pressure as low as 4 inches water
column. Its negative regulation (neg/reg)
technology eliminates mechanical dampers as
it automatically adjusts fan speed to ensure
the correct volume and mix of fuel and air
throughout the firing range.

4 INNOVATIVE FIRE-TUBE
HEAT EXCHANGER
T he fire tube design can produce a higher heat
transfer coefficient than traditional fire tubes. 4

5 BRAZED PLATE HEAT EXCHANGER


Stainless Steel Heat Exchanger that quickly
transfers heat from the boiler system to the
domestic water satisfying DHW load.

6 WATER CONNECTIONS FOR


EASY INSTALLATION
N
 PT water connections make installation easy,
especially with our optional isolation valves.
5

6
6

The product images shown are for illustration purposes only


and may not be an exact representation of the product.
H

NOBLE Dimensions and Specifications I C RELIEF VALVE


Q
R GAS
AIR INTAKE
FRONT FLUE
B D NKC 150-199 R
S
J
E I
G TOP D
D E
G D
E I
E
F F
G
F F K
G MN
MT U
A
H C
O
P
H L
H
NKC110 PQ
NKC110 H I N
O C RELIEF VAL
NKC110 TOP AIR INTAKE
I C RELIEF VALVE FLUE
BOTTOM
HIGH VOLTAGE B AIR INTAKE
CONNECTIONS FLUE
B
R
NOBLE Combi GAS
Boiler CONDENSATE Dimensions and Specifications
S WATER
J Heating Net AHRI
INLET/OUTLET
Model Input (MBH) Capacity Rating
Number Max. Min. AFUE% MBH MBH A B C D E F G

K NKC110N 110 11 95.0 102 89 32-1/2" 17-1/4" 18" 14-3/4" 2-3/4" 6-1/2" 2-3/4"
MNTU A
NKC150N 150 15 95.0 139 121 32-1/2" 18-3/4" 18" A 6-3/4" 2-3/4" 6-3/4" 11-3/4"
P
NKC199N 199 19.9
L 95.0 185 161 32-1/2" 18-3/4" 18" 5-1/2" 2-3/4" 6-3/4" 11-1/2"
Q
O

Dimensions and Specifications



HIGH VOLTA
HIGH VOLTAGE
H I J K L M N O P Q R Gas Water Air Ship CONNECTIO
Vent CONNECTIONS
Conn. Conn. Inlet
GAS
Size Wt. CONDENSATE
R
2" 3-1/2" 8-3/4" 13-1/2" 2-3/4" 9" 10-1/2" 5" 14-1/2"
R 12-3/4" 5" S
1/2" GAS 1" 3" 3"CONDENSATE
139 WATER
J 2000534158 S WATER
2-1/2" 6-1/4" 2-3/4" 13-1/2" 3" 9" 11-1/2" J 5" 6-1/4" 13-3/4" 6" 1/2" 1" 3" 3"INLET/OUTLET
142 INLET/OUTLET

2-1/4" 5-1/2" 2-3/4" 13-1/2" 2-3/4" 9-1/2" 10-1/2" 2-3/4" 5-1/2" 13" 5-1/4" 1/2" 1" 3" 3" 159
Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. *The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.
K
K
MNTU
MNTU

DHW Delivery > Low Voltage Terminal Strip > Condensate Trap
Model (GPM)* Air Handler Interlock P > Other
P Features
L L
Flow Switch Contacts
Q
Q Automatic Reset High Limit
NKC110N 2.6 Low-Water Cutoff Connection O Adjustable High Limit w/Manual Reset
O
System Sensor Contacts Built-in Circulating Pump
NKC150N 3.6 Outdoor Air Sensor Contacts Wall-Mount Bracket
Cascade Contacts Zero Clearances to Combustible Materials
NKC199N 4.8
> Time Clock for Data Logging 10-Year Warranty
* 77°F Temperature Rise Last 10 Lockouts (See Warranty for Details)
> Low-Water Flow Safety Control & Indication 5-Year Parts Warranty
> Password Security Optional Equipment
Smart Control Features ™
> Built-in Cascading Sequencer for Low-Water Cutoff w/Manual Reset & Test
up to 8 units Concentric Vent Kit
> SMART CONTROL Digital Operating Control
Condensate Neutralization Kit
LCD Display with words not codes Standard Features Sidewall Vent Termination
> Outdoor Reset Control with Outdoor
> ENERGY STAR Most Efficient Recognition Floor Stand
Air Sensor
> 95% DOE AFUE Efficiency Wireless Outdoor Sensor
> Programmable System Efficiency Optimizers
> Modulating Burner with 10:1 Turndown Nat to LP Gas Conversion Kit
DHW Response Time
Direct-Spark Ignition Isolation/Flush Valves
DHW Pre Heat
Low-NOx Operation
Outdoor Air Reset Curve
> ASME Stainless Steel Heat Exchanger Firing Codes
> Two Pump Control > M9 Standard Construction/California Code
50 psi Working Pressure w/ASME Relief Valve
System Pump
> Vertical & Horizontal Direct-Vent
Boiler Pump *Lochinvar should be consulted before selecting a boiler for
PVC, CPVC, Polypropylene or SS Venting
> High-Voltage Junction Box installations having unusual piping and pickup requirements, such
up to 100 feet
120 VAC / 60 Hertz / 1 Phase Power Supply as intermittent system operation, extensive piping systems, etc.
*The ratings have been determined under the provisions governing
forced draft burners.

Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon, Tennessee 37090
P: 615.889.8900 / F: 615.547.1000
Lochinvar.com

NKC-01(Reprint 7/17) Patent Pending ASB-10M-10/17-Printed in U.S.A.