KV440C2 - Apm403 - en
KV440C2 - Apm403 - en
KV440C2 - Apm403 - en
Standard Feature:
• KOHLER Co., provides one-source responsibility for the
generating system and accessories
Rating Range
• The generator set and it’s components are prototype-
KV440C2
50Hz tested, factory-built and production-tested
Generator Rating
Standby Prime
Alternator V Phs Hz kW/kVA Amps kW/kVA Amps
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
Preliminary Version
Alternator Specification
• IEC60034, NEMA MG1.22, ISO8528, CSA, UL,
ISO9001,ISO14001, CE standard Specification Alternator
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
Preliminary Version
Specification Controller
Cooling
Radiator System
Radiator system capacity , L (gal) 44 (11.6)
Heat rejected to cooling water at rated, kW
155 (8815)
(Btu/min)
Water pump type Centrifugal The APM403 is a versatile control unit which allows
Fan loss, kW (HP) 10 (14) operation in manual or automatic mode
Max,restriction of cooling air, intake and ⚫ Measurements: voltage and current
NA
discharge of radiator, kPA (in 𝐻2 𝑂) ⚫ kW/kWh/kVA power meters
⚫ J1939 CAN ECU engine control
Air requirement ⚫ Alarms and faults: Oil pressure, Coolant temperature,
Radiator-cooled cooling air 𝑚3 /𝑚𝑖𝑛 (scfm) 402 (14196) ⚫ Overspeed, Start-up failure, alternator min/max,
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
Preliminary Version
KOHLER CO., KOHLER Power Systems
Kohler, Wisconsin 53044 USA 400 1808 900
Phone +1 (920)-565-3381 Power@kohler.com
Kohler Power.com
Option
Canopy Others
• Canopy M229, 50Hz, 78 dB(A)@1m
• ________________________________
Standard
• Critical muffler, 40dB(A) • ________________________________
• Hospital muffler, 29dB(A) • ________________________________
• Connector, 40cm (16in)
• Bellow • ________________________________
• Protection Guard • ________________________________
• ________________________________
Cooling system
• Block heater (recommend to use when below 0℃ (32℉)
• Radiator protection cover Dimension and weight
Decision-Marker 4000 Controller Open Model
• Alternator protection
• Audible alarm module
• 5 expandable modules with 4 inputs/6 outputs
• Network modules (RTC and GSM modems and Ethernet
router)
• NFPA 100 module
• Remote annunciator Dimension, LxWxH mm: 3160 x 1805 x 1340
• Voltage/speed adjustment module Dry weight, kg: 3110
• Win Telys Software Wet weight,kg: 3570
Fuel system Canopy Model
• Automatic fuel tank fil kit
• Fuel tank with secondary containment basin
• Subbase fuel tank leak alarm
• Water separator fuel filter
Electrical System
• Battery charger, equalize/float type
• Battery isolator switch Dimension, LxWxH mm: 4475 x 2430 x 1410
Engine and alternator Dry weight, kg: 4080
• Alternator strip heater Wet weight,kg: 4170
• Air cleaner, heavy duty (with air restriction indicator)
• Droop kit with 3-function voltage regulator
• Electronic governor
• Lube oil drain pump
• PMG alternator and voltage regulator
• Tropical heavy-duty alternator insulation
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
Preliminary Version