Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

V CT 2.2D: Eddy Current Automated Inspection Instrument

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ethernde.

com

ViCTor 2.2D
EDDY CURRENT AUTOMATED INSPECTION INSTRUMENT

ETher NDE is introduces the ViCTor 2.2D, the user- ADVANTAGES


friendly automated eddy current inspection system,
• Capable of using two probes simultaneously
designed with the Automation Engineer in mind.
for more efficient inspection.
Based on the ETher NDE AeroCheck+ Hardware, NDT • Separate dual alarms.
Inspectors will become quickly familiar with its user
• Large bright LCD screen and external VGA for
interface and with a variety of case configurations
monitor output.
available, the ViCTor 2.2D offers maximum flexibility
for each individual application. • Includes rotary drive and conductivity.
• Configurable I/O capability using voltage free
contacts.
• USB or RS-232 remote control.
APPLICATIONS • Dual analogue outputs giving simple recording.
• Surface breaking defects. • Powered by 24V DC for easy integration in an
industrial control system.
• Sub-surface defects in non-ferrous materials.
• RS-232 and USB remote control for easy Control
• Heat Treatment / material property verification. System Integration.
• Sensing applications for verifying geometry such • Ability to stream real time data over USB.
as the presence of threads, butt-weld detection. • A DLL is available to permit software integration
by the end user.
ethernde.com

Eddy Current is ideally suited to inspection automation particularly of so called rotationally symmetric
components for the following reasons:
Non-contacting, High Speed (potentially up to 200ms-1), no couplant required or effluent produced, good for
surface defect detection, instant coupling, wide variety and geometry of probes available, cost effective and
ideal for rotationally symmetrical components e.g. bearings, gudgeon pins, cylinder liners etc.

Specification
Probe Connectors 2 off 12 Way Lemo 2b (Absolute, Bridge and Reflection) and Lemo 00 (for single element absolute probes)
Rotary Probe 1 only. 600-3000 rpm - ETher Mercury Drive (ARD002), Hocking 33A100 / 40A100, Rohmann MR3, SR1 and SR2
Drive (special adapter needed)
Conductivity Probe 1 only. Option becomes active with use of AeroCheck+ conductivity probe and cable
Frequency Dual Frequency 10 Hz to 12.8 MHz
Gain Overall -18 to + 104 dB
Main Gain -18 to + 82dB, 0.1, 1 and 6dB steps
Input 0dB or 12dB
Drive 0dB, 6dB and 1odB (0dB reference 1mW into 50 ohm)
Max X/Y Ratio -18dB to +82dB independent
Phase Range 0.0-359.9°, 0.1° steps
Filters Normal High Pass DC to 2kHz or Low Pass Filter, which ever is the lower in 1 Hz steps. Plus variable adaptive balance drift compensation 0.01 - 0.5 Hz
(6 steps)
Normal Low Pass 1Hz to 2kHz or a quarter of the lowest test frequency whichever is lower in 1Hz steps
Balance Manual 14 internal balance loads; 2.2µH, 5.0µH, 6.0µH, 6.5µH, 7.0µH, 7.5µH, 8.2µH, 12µH, 15µH, 18µH, 22µH, 30µH, 47µH, 82µH
Automatic Optimised balance load selection
Mix Channel Frequency Full frequency range available on both channels
Probe Mode Simultaneous reflection / bridge and absolute including simultaneous two probe Differential and Absolute
Mix Gain X/Y -18 to +18dB
Mix Phase 0.0-359.9°, 0.1° steps
Alarm Gates Number 2 Independent Alarm Gates may be configured on Pane 1, Pane 2 or Both Panes (logical or)
Box Fully configurable, Freeze, Tone or Visual
Sector Fully configurable, Freeze, Tone or Visual
Display Type 5.7” (145mm), 18 bit Colour, daylight readable
Viewable Area 115.2mm (Horizontal) x 86.4mm (Vertical)
Resolution 640 x 480 pixels
Colour Schemes User configurable Dark, Bright and Black & White
Config. Screen Full Screen, Single, Dual Spot or Dual Pane with variable size and location and function e.g. XY, Timebase, Waterfall and Meter.
Display Modes Spot, Time base (0.1-20 seconds x 1-200 sweeps and up to 55 seconds), Waterfall and Meter with peak hold and % readout.
Graticules None, Grid (4 sizes 5, 10,15 and 20% FSH), Polar (4 sizes 5, 10,15 and 20% FSH)
Offset Spot Position: Y =-50 to +50, X =-65 to +65%
Spot Readout Display in X,Y or R,θ
Summary Display of all settings in Legacy Format
Removable Setup Storage micro SD up to 32GB, holding over 10,000 settings
Data Storage Stored Screen Shots micro SD up to 32GB, holding over 10,000 screen shots
Recorded Data micro SD up to 32GB, holding over 500 2.5 minute long data recordings
Guides micro SD up to 32GB, holding 10,000 Slides
Advanced Data logging Real-time recording of signal data and replay on instruments and desktop PC up to 164 seconds
Features Guides Create and display a slide show containing instructions, tutorials and procedures using Microsoft PowerPoint.
Attachments Screenshots and Data Recordings are saved in a folder with the name of the Settings.
Loop Capture a live repetitive signal and then optimise the instrument settings (Phase, Gain, Filters) to simplify optimising the
parameters
Trace Allows a calibration reference signal to be stored on the screen and then compared with the live signal
Auto Phase Allows phase angle to be automatically set to a pre set angle
Inputs/Outputs PC Connectivity USB (Full PC remote control plus Real Time data) and RS-232 May be set Off, 9600, 19200, 38400, 57600, 115200, 230400,
460800, 921600 baud
Analogue 2 outputs 2 Volts swing
Digital volt free Alarm On Lemo 12 way Open collector transistor (36v dc at 10mA max)
VGA Full 15 way VGA output (EC screens only)
I/O Two configurable
Alarm Out 2 off Opto Isolated 2mA 50v max
External Alarm Inhibit 2 TTL Inputs
Languages English, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese, Turkish, Czech
Verification The system includes on delivery a 2 year validity Verification Level 2 detailed functional check and calibration as as per
ISO 15548-1:2013
Power on The system performs a self test on start up of external RAM, SD RAM, accelerometer, Micro SD card, LCD screen buffer
Self Test
Power External 100-240 v 50-60Hz 30 Watts
Physical Weight 3.3 kg, 7.25 lbs.
Size (w x h x d) 246 x 152 x 250 mm / 9.7 x 6.0 x 9.9 inches
Operating Temp -20 to +60 °C
Storage Temp Storage for up to 12 months -20 to +35 °C Nominal +20 °C
IP Rating 54 (front panel only)

Document number 5028: Issue 1


ETher NDE, Endeavour House, Unit 18 Brick Knoll Park, Ashley Road, St. Albans, Hertfordshire, UK
Tel: +44 (0)1582 767912 Email: sales@ethernde.com www.ethernde.com

You might also like