NI cRIO-9038: Processor
NI cRIO-9038: Processor
NI cRIO-9038: Processor
NI cRIO-9038
Embedded CompactRIO Controller with Real-Time Processor and
Reconfigurable FPGA
This document lists the specifications for the National Instruments cRIO-9038. The following
specifications are typical for the -40 °C to 70 °C operating temperature range unless otherwise
noted.
Caution Do not operate the cRIO-9038 in a manner not specified in this document.
Product misuse can result in a hazard. You can compromise the safety protection
built into the product if the product is damaged in any way. If the product is
damaged, return it to NI for repair.
Processor
CPU
............................................................................ Intel Atom E3825
Number of cores
............................................................................ 2
CPU frequency
............................................................................ 1.33 GHz
On-die L2 cache
............................................................................ 1 MB (shared)
Operating System
Note For minimum software support information, visit ni.com/info and enter the
Info Code swsupport.
Supported
............................................................................
operating system NI Linux Real-Time (64-bit)
Software requirements
Application software
LabVIEW
............................................................ LabVIEW 2014 or later,
LabVIEW Real-Time Module 2014 or later,
LabVIEW FPGA Module 2014 or later1,
C/C++
............................................................
Development Tools Eclipse Edition 2014 or later
for NI Linux Real-Time2
....................................................................
Driver software NI-RIO Device Drivers August 2014 or later
Network/Ethernet Port
Number of ports
............................................................................ 2
Network interface
............................................................................ 10Base-T, 100Base-TX, and
1000Base-T Ethernet
Compatibility
............................................................................ IEEE 802.3
Communication rates
............................................................................ 10 Mbps, 100 Mbps,
1000 Mbps auto-negotiated
Maximum cabling distance
............................................................................ 100 m/segment
1 LabVIEW FPGA Module is not required when using Scan Interface mode. To program the user-
accessible FPGA on the cRIO-9038, LabVIEW FPGA Module is required.
2 C/C++ Development Tools for NI Linux Real-Time is an optional interface for C/C++
programming of the cRIO-9038 processor. Visit ni.com/info and enter Info Code
RIOCdev for more information about the C/C++ Development Tools for NI Linux Real-
Time.
Note The RS-485 serial port ground and shield are not connected to chassis
ground. This isolation is intended to prevent ground loops and does not meet UL
ratings for safety isolation.
............................................................................
Cable requirement Unshielded, 30 m maximum length (limited by
EMC/surge)
Note RS-485 is capable of 1.2 km (4,000 ft) length without surge limitation.
USB Ports
Number of ports
....................................................................
Device ports 1 standard B connector
Host ports
.................................................................... 2 standard A connectors
Note The USB device port is intended for use in device configuration, application
deployment, debugging, and maintenance.
............................................................................
USB interface USB 2.0, Hi-Speed
Maximum data rate
............................................................................ 480 Mb/s per port
Maximum current (USB host ports)
............................................................................ 1 A (aggregate)
Mini DisplayPort
Maximum
............................................................................
resolution 2560 × 1600 at 60 Hz
Memory
Nonvolatile3
....................................................................
SD removable (user supplied) Up to 32 GB
Solid-state drive
.................................................................... 8 GB
Note Visit ni.com/info and enter the Info Code ssdbp for information about the
life span of the nonvolatile memory and about best practices for using nonvolatile
memory.
Volatile
Processor memory
............................................................
Density 2 GB
Type
............................................................ DDR3L
Maximum theoretical data
............................................................ 8.533 GB/s
rate
Data throughput
System memory to SD
.................................................................... 10 MB/s
removable storage4
Module
....................................................................
slots to system memory 20 MB/s, application- and system-dependent
Reconfigurable FPGA
............................................................................
FPGA type Xilinx Kintex-7 7K160T
Number of flip-flops
............................................................................ 202,800
Number of 6-input LUTs
............................................................................ 101,400
Number
............................................................................
of DSP slices 600
(18 x 25 multipliers)
Available block RAM
............................................................................ 11,700 kbits
3 1 MB is equal to 1 million bytes. 1 GB is equal to 1 billion bytes. The actual formatted capacity
might be less.
4 Consult the manufacturer specifications of your SD removable storage.
CMOS Battery
............................................................................
Typical battery life with power 10 years
applied to power connector
............................................................................
Typical battery life when stored at 7.8 years
temperatures up to 25 °C
............................................................................
Typical battery life when stored at 5.4 years
temperatures up to 85 °C
Power Requirements
Note Some C Series modules have additional power requirements. For more
information about C Series module power requirements, refer to the C Series
module(s) documentation.
............................................................................
Typical standby power consumption 3.4 W at 24 VDC input
Recommended power supply
............................................................................ 100 W, 24 VDC
Physical Characteristics
If you need to clean the cRIO-9038, wipe it with a dry towel.
............................................................................
Weight (unloaded) 2,250 g (4 lbs, 15 oz)
Dimensions (unloaded)
............................................................................ 328.8 mm × 88.1 mm × 109.2 mm
(12.94 in. × 3.47 in. × 4.30 in.)
Screw-terminal wiring
Gauge
.................................................................... 0.5 mm 2 to 2.1 mm2 (20 AWG to 14 AWG)
copper conductor wire
....................................................................
Wire strip length 6 mm (0.24 in.) of insulation stripped from the
end
Temperature
....................................................................
rating 85 °C
Torque for screw terminals
.................................................................... 0.20 N · m to 0.25 N · m (1.8 lb · in. to
2.2 lb · in.)
Wires
....................................................................
per screw terminal One wire per screw terminal
Safety Voltages
Connect only voltages that are below these limits.
V1
............................................................................
terminal to C terminal 30 VDC maximum, Measurement Category I
V2 terminal to C terminal
............................................................................ 30 VDC maximum, Measurement Category I
Chassis ground to C terminal
............................................................................ 30 VDC maximum, Measurement Category I
Caution Do not connect the cRIO-9038 to signals or use for measurements within
Measurement Categories II, III, or IV.
Note Measurement Categories CAT I and CAT O are equivalent. These test and
measurement circuits are not intended for direct connection to the MAINS building
installations of Measurement Categories CAT II, CAT III, or CAT IV.
Environmental
Temperature (IEC-60068-2-1 and IEC-60068-2-2)
....................................................................
Operating -40 °C to 70 °C
Storage
.................................................................... -40 °C to 85 °C
Caution Failure to follow the mounting instructions in the user manual can cause
temperature derating. Visit ni.com/info and enter Info Code criomounting for
more information about mounting configurations and temperature derating.
Ingress
............................................................................
protection IP20
............................................................................
Operating humidity 10% RH to 90% RH, noncondensing
(IEC 60068-2-56)
Storage
............................................................................
humidity (IEC 60068-2-56) 5% RH to 95% RH, noncondensing
Hazardous Locations
U.S.
............................................................................
(UL) Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, AEx nA IIC T4
Canada (C-UL)
............................................................................ Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, Ex nA IIC T4
............................................................................
Europe (ATEX) and Ex nA IIC T4 Gc
International (IECEx)
Operating vibration
....................................................................
Random (IEC 60068-2-64) 5 grms, 10 Hz to 500 Hz
Sinusoidal (IEC 60068-2-6)
.................................................................... 5 g, 10 Hz to 500 Hz
Operating shock (IEC 60068-2-27)
............................................................................ 30 g, 11 ms half sine; 50 g, 3 ms half sine;
18 shocks at 6 orientations
Note For UL and other safety certifications, refer to the product label or the Online
Product Certification section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:
• EN 61326-1 (IEC 61326-1): Class A emissions; Industrial immunity
• EN 61000-6-2: Immunity
• EN 55011 (CISPR 11): Group 1, Class A emissions
• EN 55022 (CISPR 22): Class A emissions
• EN 55024 (CISPR 24): Immunity
• AS/NZS CISPR 11: Group 1, Class A emissions
• AS/NZS CISPR 22: Class A emissions
• FCC 47 CFR Part 15B: Class A emissions
• ICES-001: Class A emissions
Note In the United States (per FCC 47 CFR), Class A equipment is intended for
use in commercial, light-industrial, and heavy-industrial locations. In Europe,
Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended
for use only in heavy-industrial locations.
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical
equipment that does not intentionally generate radio frequency energy for the
treatment of material or inspection/analysis purposes.
Note For EMC declarations and certifications, and additional information, refer to
the Online Product Certification section.
CE Compliance
This product meets the essential requirements of applicable European Directives, as follows:
• 2014/35/EU; Low-Voltage Directive (safety)
• 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
• 94/9/EC; Potentially Explosive Atmospheres (ATEX)
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.
For additional environmental information, refer to the Minimize Our Environmental Impact
web page at ni.com/environment. This page contains the environmental regulations and
directives with which NI complies, as well as other environmental information not included in
this document.
电子信息产品污染控制管理办法(中国 RoHS)
中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物
质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录
ni.com/environment/rohs_china。(For information about China RoHS
compliance, go to ni.com/environment/rohs_china.)
Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and
other services.
A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting ni.com/certification. If your product supports
calibration, you can obtain the calibration certificate for your product at ni.com/calibration.
375696B-02 Apr15